BA282 VISHAY

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(free datasheet download site)
  • PDF pages: 3

Technical content

Features

/C0068Low differential forward resistance /C0068Low diode capacitance /C0068High reverse impedance

Applications

Band switching in VHF–tuners 94 9367 Absolute Maximum Ratings Tj = 25/C0095C Parameter Test Conditions Type Symbol Value Unit Reverse voltage VR 35 V Forward current IF 100 mA Junction temperature Tj 150 /C0176C Storage temperature range Tstg –55...+150 /C0176C Maximum Thermal Resistance Tj = 25/C0095C Parameter Test Conditions Symbol Value Unit Junction ambient l=4mm, TL=constant R thJA 350 K/W

BA282.BA283 Vishay Telefunken Rev. 2, 01-Apr-992 (3) www.vishay.de • FaxBack +1-408-970-5600 Document Number 85526

Electrical Characteristics

Tj = 25/C0095C Parameter Test Conditions Type Symbol Min Typ Max Unit Forward voltage IF=100mA VF 1 V Reverse current VR =20 V IR 50 nA Diode capacitance f=100MHz, VR =1V C D 1.5 pF f=100MHz, VR =3V BA282 C D 1.25 pFR BA283 C D 1.2 pF Differential forwardf=200MHz, IF=3mA BA282 rf 0.7 /C0087 resistance F BA283 rf 1.2 /C0087 f=200MHz, IF=10mA BA282 rf 0.5 /C0087F BA283 rf 0.9 /C0087 Reverse impedance f=100MHz, VR =1V zr 100 k/C0087 Characteristics (Tj = 25/C0095C unless otherwise specified) 0.1 1 10 0.1 100 r – Differential Forward Resistance ( )f IF – Forward Current ( mA ) 100 94 9072 /C0087 BA 282 BA 283 f = 200 MHz Tj=2 5°C Figure 1. Differential Forward Resistance vs. Figure 2. Diode Capacitance vs. Reverse Voltage

54 A 2 DIN 41880

BA282.BA283 Vishay Telefunken Rev. 2, 01-Apr-99 3 (3) www.vishay.de • FaxBack +1-408-970-5600Document Number 85526 Ozone Depleting Substances Policy Statement It is the policy of Vishay Semiconductor GmbH to 1. Meet all present and future national and international statutory requirements. 2. Regularly and continuously improve the performance of our products, processes, distribution and operating systems with respect to their impact on the health and safety of our employees and the public, as well as their impact on the environment. It is particular concern to control or eliminate releases of those substances into the atmosphere which are known as ozone depleting substances (ODSs). The Montreal Protocol (1987) and its London Amendments (1990) intend to severely restrict the use of ODSs and forbid their use within the next ten years. Various national and international initiatives are pressing for an earlier ban on these substances. Vishay Semiconductor GmbH has been able to use its policy of continuous improvements to eliminate the use of ODSs listed in the following documents. 1. Annex A, B and list of transitional substances of the Montreal Protocol and the London Amendments respectively 2. Class I and II ozone depleting substances in the Clean Air Act Amendments of 1990 by the Environmental Protection Agency (EPA) in the USA 3. Council Decision 88/540/EEC and 91/690/EEC Annex A, B and C (transitional substances) respectively. Vishay Semiconductor GmbH can certify that our semiconductors are not manufactured with ozone depleting substances and do not contain such substances. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All operating parameters must be validated for each customer application by the customer. Should the buyer use Vishay-Telefunken products for any unintended or unauthorized application, the buyer shall indemnify Vishay-Telefunken against all claims, costs, damages, and expenses, arising out of, directly or indirectly, any claim of personal damage, injury or death associated with such unintended or unauthorized use. Vishay Semiconductor GmbH, P.O.B. 3535, D-74025 Heilbronn, Germany Telephone: 49 (0)7131 67 2831, Fax number: 49 (0)7131 67 2423