www.ZETTLER-group.com page 1 of 4 2023-01-11

40 AMP 2 POLES POWER RELAY WITH MONITORING

2PST-NO (2 Form A) SPST-NC (1 Form B) coupled to load contacts Ratings (max.) load contacts switched power switched current continuous current switched voltage contact load category monitor contact switched current minimum load (resistive load) 19200 VA 40 A 40 A

480 VAC

10 mA, 5 VDC, 50 mW (gold plated contact) Approved ratings load contacts monitor contact (TÜV, UL/CUR, CQC)

40 A at 480 VAC, resistive, 85°C, 6k cycles

35 A at 400 VAC, resistive, 85°C, 50k cycles

32 A at 400 VAC, resistive, 95°C, 50k cycles

10 A make, 40 A carry, 10 A break

at 480 VAC, 85°C, resistive, 50k cycles 10 mA at 12 VDC, 85°C, 50k cycles Contact material load contacts monitor contact AgSnO2 (silver tin oxide) AgNi + Au (silver nickel, gold plated) Contact gap load contacts monitor contact (clearance of open contacts) ≥ 3.42 mm ≥ 0.7 mm (≥ 0.5 mm if load contacts are welded) Contact resistance load contacts monitor contact ≤ 10 mΩ initial max. (20 A) < 2 mΩ typ. (32 A) ≤ 100 mΩ CONTACTS Life Expectancy mechanical electrical (minimum operations) 1 x 105 see rated loads Operate Time ≤ 30 ms (at nominal coil voltage) Release Time ≤ 10 ms (at nominal coil voltage, without coil suppression) Dielectric Strength open load contacts between load contact sets coil to load contacts load to monitor contacts open monitor contacts coil to monitor contacts (at sea level for 1 min.) 2 kVRMS 2 kVRMS 5 kVRMS 5 kVRMS 1 kVRMS 1 kVRMS Surge Voltage open load contacts coil to load contacts load to monitor contacts (1.2/50 µs pulses) 6 kV 10 kV 8 kV Insulation Distances load contact sets coil to load contacts load to monitor contacts coil to monitor contact (clearance / creepage) Insulation Resistance ≥ 1000 MΩ (23°C, 500 VDC, 50% rh) Short circuit capacity referring to IEC 62955 referring to IEC 62752 referring to IEC 62052-11 Ip = 1.85 kA; I²t = 4.5 kA²s Ip = 1.50 kA; I²t = 6.0 kA²s Ip = 1.36 kA; I²t = 9.25 kA²s Temperature Range operating (at coil holding voltage) Vibration resistance 0.062” (1.5 mm) DA at 10–55 Hz Shock 10 g Enclosure protection category material group flammability PBT polyester RT II, flux proof IIIa UL94 V-0 Terminals Tinned copper alloy, THT PCB mounting Soldering preheating soldering (referring IEC 61760-1 wave soldering) Dimensions (L/W/H) 36.5 mm / 33.8 mm / 41.5 mm Weight 85 grams (approx.) Compliance UL 508, IEC 61810-1, GB/T 21711.1-2008, RoHS, REACH Agency Approvals TÜV UL / CUR CQC B 088793 0020 E365652 CQC22002356459 Packing (pcs.) 10 per plastic tube 150 per carton box GENERAL DATA

FEATURES

  • Designed for IEC 61851 Mode 2 and Mode 3 charging applications
  • Dual NO load contacts plus NC mirror contact acc. EN 60947-4-1 for welding monitoring
  • 40 Amp / 480 VAC switching capability
  • Meets IEC 62955, IEC 62752 and IEC 62052-11 short circuit requirements
  • Load contact gap ≥ 3.42 mm
  • Dielectric strength 5 kVRMS, surge withstand voltage 10 kV
  • TÜV, UL / CUR and CQC approvals Nominal coil voltages 6, 9, 12, 24, 48 (DC) Dropout voltage > 5% of nominal coil voltage Holding voltage 35 - 80% of nominal coil voltage (@23°C) 40 - 65% of nominal coil voltage (@85°C) Power nominal holding power (at 23°C) 2.6 W 420 mW Release energy < 7 mJ Thermal resistance 35 K/W (typ. at 40 - 80% nom. coil voltage) Temperature rise 70 K (126°F) Insulation system class F, max. temperature 155°C (311°F) COIL

www.ZETTLER-group.com page 2 of 4 2023-01-11 ORDERING DATA Example ordering data AZEV200-2AE1B-12D 1 Form B monitor contact, 12 VDC coil voltage AZEV200-2AE-24D version without monitor contact, 24 VDC coil AZEV200-2AE1B-12D(001) special version with non gold plated 1 Form B monitor contact. Nominal coil voltage see coil voltage specifications table Monitor contact nil: without monitor contact 1B: equipped with 1 Form B monitor contact Option nil: standard version (xxx): special version PCB FOOTPRINT / WIRING DIAGRAM Layout and footprint recommendation. Dimensions in mm. Viewed towards terminals. Resistance [Ω] ±10% Inductance (ref.) [mH] Current (ref.) [mA] Power (ref.) [W] Voltage [VDC] nominal must operate min. holding max. de-energized excited nominal min. holding nominal min. holding 6 4.5 2.4 6.6 13.9 130 165 432 173 2.6 0.42 9 6.7 3.6 9.9 31.2 290 370 288 116 12 9.0 4.8 13.2 55.4 520 660 216 87 24 18.0 9.6 26.4 221.5 2050 2640 108 44 48 36.0 19.2 52.8 886.2 8200 10560 54 22 COIL VOLTAGE SPECIFICATIONS Notes: 1. All values at 23°C, upright position, terminals downward. 2. Voltage max. is the voltage the coil can endure for a short period of time. 3. Values for coil inductance, coil current and coil power for reference only. 4. To avoid overheating at elevated ambient temperatures, operate the coil at 40 - 65% of nominal coil voltage after applying the full nominal coil voltage for ≥200 milliseconds. MECHANICAL DATA Dimensions in mm. Tolerance: ±0.3mm. Pin dimensions for reference only and given without tin coating. CAD data in attachment of the datasheet. TIMING DIAGRAM Coil energization NO load contact (1 - 2) NO load contact (3 - 4) NC monitor contact (11 -12) t tarct6 t8t7 t3 tarc full hold off open closed open closed open closed release condition operate release release conditionoperate condition Description Notes Timing [ms] Item min. typ. max. t1 Full energization time recommended value for reference 200 - - t2 NO operate time at nominal coil voltage - 18 30 t3 NO bounce time at nominal coil voltage - 3.5 - t4 NO sync time at nominal coil voltage - ±0.1 - t5 NC operate time at nominal coil voltage - 10 - t6 NO release time without coil suppression - - 10 with suppression: UBR/Unom = 2 - 3.5 - t7 NC release time with suppression: UBR/Unom = 2 - 5.7 - t8 NC bounce time - 10.5 - tarc arcing duration if released under load, dependent on actual load Notes: 1. Unom is the specified nominal coil voltage. 2. UBR is the coil suppression circuit breakdown voltage.

www.ZETTLER-group.com page 3 of 4 2023-01-11 CHARACTERISTICS 0 1 2 3 4 5 6 Ratio UBR / Unom. Release time [ms] Release time vs. suppressor breakdown voltage (typ.) make NC contact (11-12) break NO contacts (1-2, 3-4) 8 75 100 125 150 % Energization ratio Ucoil / Unom. Operate time [ms] Operate timing vs. coil energization @23°C (typ.) 175 200 stable close NO contacts make NO contacts (1-2, 3-4) break NC contact (11-12) Coil temperature rise vs. energization @23°C (typ.) 30 50 70 90 % Energization ratio Ucoil / Unom. Temperature rise [K] 100 100 0.5 Coil power [W] 1.5 2.5 coil power consumption coil temperature rise NOTES General 1. All values in this datasheet are at reference temperature of 23°C (73°F) unless stated otherwise. 2. Evaluate the component’s performance and operating conditions under the worst-case conditions of the actual application. 3. The datasheet and the component’s specifications are subject to change without notice. Storage, handling, and environmental guidelines 4. Relays are electromechanical components that are sensitive to shock. The relay ’s adjustment can be affected if the relay is subjected to excessive shock or excessive pressure is applied to the relay case. Relays which have been dropped must no longer be used. 5. Substances containing silicone or phosphorus must be avoided in the vicinity to the relay. Outgassing from these substances c an penetrate the relay and adhere on the contacts. Deposits of these substances may act as insulators and adversely affect the contact resistance. Silicone can be found e.g. in gaskets, lubricants or filling materials, phosphorus can be found e.g. as a flame retardant in plastics. 6. Prevent relays from atmospheres containing corrosive gases. Corrosion of internal structures and contacts leads to malfunctio n a nd shortens the component’s service life. 7. Prevent non-sealed relays from atmospheres subject to dust. Dust particles may enter the case and get stuck between the contacts, causing the contact circuits to fail. 8. Do not use these relays in environments with explosive or flammable gases. Electrical arcing at the contacts could ignite these gases and cause fire. 9. For automated dual wave soldering process we recommend preheating with 120°C (248°F) for max. 120 seconds and a soldering tem perature of 260 ±5°C (500 ±9°F) for max. 10 seconds soldering time (max. 5 seconds per wave). For manual soldering we recommend 350°C (662°F ) max. temperature for max. 5 seconds. During the soldering process, no force may be exerted on the relay terminals. 10. This relay is designed according to RTII relay technology (flux -proof). It must not be washed, immersion cleaned or conformal co ated as substances may enter the case and cause corrosion or seizure of mechanical parts. 11. Avoid high frequency or ultrasonic vibrations on the relays as these can cause contact welding and misalignment or destruction of internal structures. 12. During operation, storage and transport, ambient temperature should be within the specified operating temperature range. Humi dity should be in the range of 5% to 85% RH. Icing and condensation must be avoided. Relays stored for an extended period of time may show initiall y increased contact resistance values due to chemical effects such as oxidation. Design guidelines 13. The relay may pull in and operate with less than the specified must operate voltage value. 14. The coil’s must operate and min. holding voltages and the coil’s resistance value depend on the temperature of the coil. The specified values are given for a coil temperature of 23°C and increase by approx. 0.39% per Kelvin of temperature rise. This circumstance must be consid ered, especially during operation with high load currents and elevated ambient temperature. 15. Coil suppression circuits such as diodes, etc. in parallel to the coil will lengthen the release time. We recommend using sup pression circuits with a breakdown voltage of approx. 2 times the nominal coil voltage in order to achieve a quick release time. 16. At elevated ambient temperatures, after applying the rated nominal coil voltage for ≥ 200 milliseconds, the coil energization must be reduced to a holding level in order to reduce thermal stress and prevent the coil from overheating. 17. For PWM coil control use a fast -switching bypass diode in parallel with the coil to allow the coil current to flow during pulse pauses. Note that this bypass diode increases the release time of the relay. We recommend ≥ 20 kHz as a PWM frequency in order to avoid audible noise from magnetostriction. 18. Contact resistance is a function of load current, dwell time and wear level of the contacts. Immediately after closing the co ntacts, or if tested with low current only, the contact resistance will show a relatively high value. A low level steady state contact resistance is reache d at higher current after a certain time in thermal equilibrium. 19. The relay dissipates heat form power losses through its load terminals. Provide sufficient cross section and area of the PCB traces so that they can act as heat spreader. 20. For PCBs with multiple relays, do not place the components directly next to each other. We suggest providing a mounting dista nce of minimum 10 mm to allow for better cooling. 21. A minimum load of 10 mA / 5 V / 50 mW is recommended for gold plated contacts to ensure a reliable and stable connection.

www.ZETTLER-group.com page 4 of 4 2023-01-11 DISCLAIMER This product specification is to be used in conjunction with the application notes which can be downloaded from the regional ZETTLER relay websites. The specification provides an overview of the most significant part features. Any individual applications and operating conditions are not taken into consideration. It is recommended to test the product under application conditions. Responsibility for the application remains with the custo mer. Proper operation and service life cannot be guaranteed if the part is operated outside the specified limits. ZETTLER GROUP Building on a foundation of more than a century of expertise in German precision engineering, ZETTLER Group is a world -class enterprise, engaged in the design, manufacturing, sales and distribution of electronic components. Our industry leadership is based on a unique combination of engineering competence and global scale. For more information on other ZETTLER Group companies, please visit zettler-group.com. For support on this product or other ZETTLER relays, please visit one of the group sites below. SITES FOR ZETTLER RELAYS NORTH AMERICA American Zettler, Inc. www.azettler.com sales@azettler.com CHINA Zettler Group, China www.zettlercn.com relay@zettlercn.com EUROPE Zettler Electronics, GmbH www.zettlerelectronics.com office@zettlerelectronics.com Zettler Electronics, Poland www.zettlerelectronics.pl office@zettlerelectronics.pl ASIA PACIFIC Zettler Electronics (HK) Ltd. www.zettlerhk.com sales@zettlerhk.com