PS-AT17LV010 ATMEL
Document overview
- Manufacturer or author: Provided By digicamel.com
- PDF pages: 15
Technical content
MICROCIRCUIT, MEMORY, DIGITAL, CMOS, 1 MEGABIT SERIAL EEPROM, MONOLITHIC SILICON Revision Written by Approved by Date A A. GENTIL / S. JAMES C. FERRE 02/12/05
DOCUMENTATION CHANGE NOTICE Date of update Revision letter modifications
1 GENERAL
1.1 Scope
This specification details the ratings, physical and electrical characteristics, tests and inspection data of the 1 megabit serial EEPROM named AT17LV010. It also defines the specific requirement for space and military applications with high reliability.
1.2 Identification
Part number Description Access Time Case Application AT17LV010-10DP-MQ 1 megabit serial eeprom 60ns Flat pack 400 mils 28 leads Military application AT17LV010-10DP-SV 1 megabit serial eeprom 60ns Flat pack 400 mils 28 leads Space application
1.3 Absolute maximum ratings
Maximum junction temperature (T 1.4 Recommended operating conditions.
1.5 Radiation features
Tested up to a Total Dose of (according to MIL STD 883 Method 1019) : No Single Event Latch-up below a LET Threshold of 80 MeV/mg/cm
1.6 Handling precautions
These components are susceptible to damage by electrostatic discharge. Therefore, suitable precautions shall be employed for protection during all phases of manufacturing, testing, shipment and any handling.
2 APPLICABLE DOCUMENTS
from heavy ion irradiation of semiconductor devices ATMEL Aerospace Products Quality Flows In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence.
3 REQUIREMENTS
3.1 Design, construction, and physical dimensions. The design, construction, and physical dimensi ons shall be as specified in MIL-PRF-38535 and herein. 3.1.1 Package type. The package shall be a flat pack 400 mils, 28 leads (figure1). The case shall be hermetically sealed and have a ceramic body. The leads shall be brazed. 3.1.2 Terminal connections. The terminal connections shall be as specified on figure 2 . 3.1.3 Block diagram. The block diagram shall be as specified on figure 3 . 3.1.4 Timing waveforms. The timing waveforms shall be as specified on figure 4.
3.2 Marking
Each component shall be marked in respect of : (a) Lead Identification (b) Component Number (c) Traceability Information (d) Manufacturer’s Component Number
3.2.1 Lead Identification
An index shall be located at the top of the package in the position defined in Figure 1.
3.2.2 Component Number
Each component shall bear the component number which shall be constituted and marked as follows : AT17LV010-10DP-XX Product identification Speed (10 = 100 ns) Package (DP = flat pack 28) Level (MQ=Military Level B – SV=Space Level B)
3.2.3 Traceability Information
Each component shall be marked in respect of traceability information : lot number and date code.
3.3 Electrical characteristics
The parameters to be measured with respect of electrical characteristics are scheduled in Table 1. The measurements shall be performed at T amb=22 ± 3°C, T high=125 (+0/-5)°C and T low = -55 (+5/-0)°C respectively.
3.4 Burn-in test
3.4.1 Electrical circuit
Circuit for use in performing the power burn-in is shown in figure 5, in accordance with the intent specified in test method 1015 of MIL-STD-883.
3.4.2 Parameters drift value
For space application, the parameter drift values applicable to burn-in are specified in Table 2 of this specification. Unless otherwise stated, measurements shall be performed at + 22 + 3 ° C. The parameter drift values (Δ), applicable to the parameters scheduled, shall not be exceeded. In addition to these drift value requirements, t he appropriate limit value specified for a given parameter in Table 1 shall not be exceeded.
3.5 Environmental and Endurance Tests
3.5.1 Electrical Circuit for Operating LifeTest
The circuit for operating life testing shall be as specified for power burn in (figure 5).
3.5.2 Electrical Measurements at Completion of Environmental and endurance tests
The parameters to be measured are scheduled in Table 1. Unless otherwise stated, the measurements shall be performed at tamb = 22+3°C.
3.5.3 Conditions for Operating LifeTest
The conditions for operating life testing shall be as specified for power burn in.
3.6 Total dose irradiation testing
3.6.1 Bias Conditions
Continuous bias shall be applied during irradiation testing as shown in Figure 6 of this specification.
3.6.2 Electrical Measurements
The parameters to be measured prior to, during and on completion of irradiation texture are scheduled in Table 1 of this specification.
4 QUALITY ASSURANCE PROVISIONS
4.1 Wafer lot acceptance test
Compliant with ATMEL Quality Management System.
For space application, Wafer Lot is accepted by a SEM performed according to PAQC0016 (PAQC0016 referred to MIL-Std-883 method 2018 and 21400 ESCC specification). 4.2 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535. 4.3 Screening. Screening equivalent to MIL-PRF-38535. Screening shall be conducted on all devices prior to qualification and technology conformance inspection
- The burn-in test duration, test condition and test temperature, or approved alternatives shall be as specified in accordance with MIL-PRF-38535.
- Additional screening for space application devices shall be as specified in MIL-PRF-38535, appendix B.
4.4 Quality conformance inspection
Qualification inspection for high reliability and s pace applications devices shall be in accordance with MIL-PRF-38535. Inspections to be performed s hall be those specified in MIL-PRF-38535 and herein for groups A, B, C, D, and E inspections. 4.4.1 Group A inspection.
- Tests shall be as specified in table 1 herein.
- Subgroups 7 and 8 of table I of method 5005 of MIL STD 883 shall include verifying the functionality of the device.
- O/V (latch up) tests shall be measured only for the initial qualification and after any process or design changes which may affect the performance of the device.
- Capacitance measurement shall be measured only for initial qualification and after any process or design changes which may affect input or output c apacitance. Capacitance shall be measured between the designated terminal and GND at a frequency of 1 MHz. Sample size is five devices with no failure, and all input and output terminals tested. 4.4.2 Group C inspection. The group C inspection end-point electrical parameters shall be as specified in table 1 herein. 4.4.3 Group D inspection. The group D inspection end-point electrical parameters shall be as specified in table 1 herein.
4.5 Delta measurements
Delta measurements, as specified in table 2, shall be made and recorded before and after the required burn-in screens to determine delta compliance. The electrical parameters to be measured, with associated delta limits are listed in table 2. The dev ice manufacturer may, at his option, either perform delta measurements or within 24 hours after life test per form final electrical parameter tests, subgroups 1, 7 and 9.
5 PACKAGING
5.1 Packaging requirements
The requirements for packaging shall be in accordance with MIL-PRF-38535.
TABLE I. Electrical performance characteristics. Test method Mil- Std-883 Limits Unit Note Test Sym bol Conditions +3 V ≤ VDD ≤ +3.6 V unless otherwise specified Min Max High level input voltage VIH 3013 V DD = 3.6 V 2 V 4 Low level input voltage VIL 3013 V DD = 3.0 V 0.8 V 4 High level output voltage VOH 3007 V DD =3 V, IOH = -2 mA VSS =0V
2.4 V 3
VOL 3007 V DD =3 V, IOL = 3 mA VSS =0V
0.4 V 3
IIL 3009 V IN =0 VDD = 3.6V VSS =0V -10 μA 3 High level Input current IIH 3009 V IN =VDD = 3.6V VSS =0V 10 μA 3 Supply current Active mode ICCA 3005 V DD = 3.6V VSS =0V 5 mA 3 Supply current Standby mode ICCS 3005 V DD = 3.6V VSS =0V 150 µA 3 Input capacitance C IN 3012 V IN = 0 V VSS =0V TC = 25°C fIN = 1.0 MHz 12 pF 5 Output capacitance C OUT 3012 V OUT = 0 V VSS =0V TC = 25°C fIN = 1.0 MHz 12 pF 5 Maximum clock frequency FMAX 10 MHz CE setup time to CLK (to guarantee proper counting) T SCE 3003 VDD = 3 V &VDD = 3.6 V, FMAX 35 ns CE hold time to CLK (to guarantee proper counting) T HCE 3003 V DD = 3 V &VDD = 3.6 V, FMAX 0 ns 3 CLK low time T LC 3003 V DD = 3 V &VDD = 3.6 V, FMAX 25 ns 4 CLH high time T HC 3003 V DD = 3 V &VDD = 3.6 V, FMAX 25 ns 4 OE high time (to guarantee counter is reset) T HOE 3003 V DD = 3 V &VDD = 3.6 V, FMAX 25 ns OE to data delay (1) TOE 3003 V DD = 3 V &VDD = 3.6 V, FMAX 55 ns CLK to data delay (1) T CAC 3003 V DD = 3 V &VDD = 3.6 V, FMAX 60 ns 3 Data hold from CE , OE or CLK TOH 3003 V DD = 3 V &VDD = 3.6 V, FMAX 0 ns 3, 6 CE or OE to data float delay (2) TDF 3003 V DD = 3 V &VDD = 3.6 V, FMAX 50 ns CE to data delay (1) TCE 3003 V DD = 3 V &VDD = 3.6 V, FMAX 60 ns
TABLE 2. Parameter drift values Note : the above parameter shall be recorded before and after burn-in and life test to determine the delta.
FIGURE 1. Case outline
FIGURE 2. Terminal connections.
1 RESET /OE
3 WP2
5 GND
11 CEO
14 READY
17 EN_SER
19 VCC
24 DATA
25 CLK
26 WP1
28 NC*
Description
RESET /OE Output enable (active high) and reset (active low) when EN_SER is high. The logic polarity of this input is programmable WP1,WP2 Used to protect portions of memory during programming CE Chip enable input CEO Chip enable output READY Open collector reset state indicator EN_SER Serial enable DATA Tri-state data for configuration CLK Clock input VCC GND Power Ground
FIGURE 3. Block diagram
FIGURE 4. Timing waveforms.
FIGURE 5. Electrical circuit for power burn-in and operating life test. S1 to S4 are signals which enable to read continuously the Eeprom 1 Meg memory plan according to the Figure 4a.
FIGURE 6. Electrical circuit for total dose radiation test.