AP12F070045A ETC2

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 11

Technical content

SPE-11-8-094/D/SS | page 1 of 11 AP.12F.07.0045A Specification Part No. AP.12F.07.0045A Product Name 12mm Two Stage 25dB GPS Active Patch Antenna Module with front-end Saw Filter Feature 13.4*13.4*5.7mm (Ground Plane) 45mm Ø1.13 cable IPEX MHFI (U.FL) 28dB LNA Wide Input Voltage 1.8V to 5.5V Low Power Consumption RoHS Compliant

SPE-11-8-094/D/SS | page 2 of 11 The AP.12F has been designed specifically for embedded (inside device) integration with GPS receiver modules where there is a GSM transmitter nearby and risk of interference and saturation. The AP.12F combines a 12*12*3.5mm advanced low profile ceramic patch antenna with a two stage LNA and a front- end SAW filter with ultra thin coaxial cable. Only 5.6mm in height, this Taoglas active antenna module utilises XtremeGainTM technology for the highest industry sensitivity. The AP.12F consists of 2 functional blocks – the LNA and also the patch antenna. The AP.12F has a SAW filter on the front of it. The main use of the AP.12F would be for small devices where the GSM transmitter is close to the GPS antenna, it helps avoid burn-out of the LNA or the module due to interference from the GSM transmitter at out band frequencies. 1. Introduction ANTENNA SAW Filter LNA LNA I-PEX + cable

SPE-11-8-094/D/SS | page 3 of 11 2. Specification

2.1 Patch Antenna

2.2 LNA

Frequency 1575.42 ± 1.023MHz Gain @ Zenith -5dBic Typ. @ Zenith Polarization RHCP Axial Ratio 4.0dB max @ Zenith Patch Dimension 12*12*3.5mm Parameter Specification Frequency 1575.42 ± 1.023MHz Outer Band Attenuation F0=1575.42MHz F0±30MHz 8dB min. F0±50MHz 20dB min. F0±100MHz 25dB min. Output Impedance 50Ω Output VSWR 2.0 Max Pout at 1dB Gain Compression point Typ. 11dBm Min. 5dBm LNA Gain, Power Consumption and Noise Figure Voltage LNA Gain (Typ) Power Consumption(mA) Typ Noise Figure Typ Min. 1.8V 20dB 4mA 2.0dB Typ. 3.0V 28dB 9mA 2.0dB Max. 5.5V 29dB 20mA 2.0dB Parameter Specification RF Cable Coaxial Cable Ø 1.13 ± 0.1mm, length 45 ± 2.5mm Connector IPEX MHFI (U.FL)

2.3 Cable* & Connector

SPE-11-8-094/D/SS | page 4 of 11 3. LNA Gain and Out Band Rejection @3.0V Cg1 Tr1 S21 >1 1.5754200 GHz 28.206 dB Cg1 Tr1 S21 2 1.6054200 GHz 18.456 dB Cg1 Tr1 S21 3 1.5454200 GHz 13.008 dB Cg1 Tr1 S21 4 1.6254200 GHz -15.497 dB Cg1 Tr1 S21 5 1.5254200 GH 7.6131 dB Cg1 Tr1 S21 6 1.6754200 GHz -4.3556 dB Cg1 Tr1 S21 7 1.4754200 GHz 2.6855 dB Tr1 S21 Log Mag 10.00dB/ Ref -40.00dB (F2) 1 Center 1.57542 GHz Span 400 MHz CorIFBW 500 kHz 40.00 30.00 20.00 10.00 0.000 -10.00 -20.00 -30.00 -40.00 -50.00 -60.00 >1 1.5754200 GHz 28.206 dB

SPE-11-8-094/D/SS | page 5 of 11 4. LNA Noise Figure @3.0V 5. Total Specification (through Antenna, LNA, Cable and Connector) Parameter Specification Frequency 1575.42 ± 1.023MHz Gain At 3V: 23 ± 4dBic @ 90° Output Impedance 50Ω Polarization RHCP Output VSWR Max 2.0 Operation Temperature -40°C to + 85°C Storage Temperature -40°C to + 85°C Relative Humidity 40% to 95% Antenna 13.4*13.4*5.7mm 40.00 GAIN Scale/ 5.000 dB -10.00 Mkr1 1.5754 GHz 1.984 dB 28.025 dB Center 1.57542 GHz BW 4 MHz Points 11 Span 3.00 MHz Tcold 296.50 K Avgs Off Att 0/ - - dB Loss Off Corr 9.000 NFIG Scale/ 1.000 dB -1.000

-10 -15 -20 -25 -30 -35 -4090 270 180 SPE-11-8-094/D/SS | page 6 of 11 6. Radiation Patterns

6.1 XZ Plane Radiation

Pattern Model No. Test Mode Freq (MHz) Max Gain(dBi) Min Gain(dBi) Avg. Gain(dBi) Source Polar. Date

-10 -15 -20 -25 -30 -35 -4090 270 180 SPE-11-8-094/D/SS | page 7 of 11

6.2 YZ Plane Radiation

Pattern Model No. Test Mode Freq (MHz) Max Gain(dBi) Min Gain(dBi) Avg. Gain(dBi) Source Polar. Date

-10 -15 -20 -25 -30 -35 -40 SPE-11-8-094/D/SS | page 8 of 11

6.3 XY Plane Radiation

Pattern Model No. Test Mode Freq (MHz) Max Gain(dBi) Min Gain(dBi) Avg. Gain(dBi) Source Polar. Date

SPE-11-8-094/D/SS | page 9 of 11 7. Technical Drawing This drawing and its inherent design concepts are property of Taoglas. Not to be copied or given to third parties without the written consent of Taoglas. TW Design Centre "A" NOTES: 1.Soldered area. 2.Shielding case area. 3.Double Sided Ahesive area. 3.All material must be RoHS compliant. 4.The connector orientation has a fixed position to the antenna as per drawing. Top Side Bottom C E2 Add logo+P/N on the patch Kiwi 2011/11/7 C Name Material Finish QTY AP.12F Patch(12*12*4mm) Ceramic Clear 1 FEP Gray2

3 GoldBrass

1.13 Coaxial Cable

14 Tin PlatedTin (SPTE)Shielding Case

15 GreenFR4 0.5tAP.12F PCB P/N AP.12F OD.113.CM IPEX.MHFI.113

16 White LinerNITTO 5015Double Sided Adhesive

AP.12F IPEX MHF 1 D E3 E4 D1 D5 Amend Patch Placed Direction And Amend Shielding Case Size Sandy 2012/01/17 D D D D E C3 Sandy 2012/02/07Amend Double Sided Adhesive Size E NOTE: 1. Soldered area 2. Shielding case area 3. All material must be RoHS compliant. 4. The connector orientation has a fixed position to the antenna as per drawing. This drawing and its inherent design concepts are property of Taoglas. Not to be copied or given to third parties without the written consent of Taoglas. TW Design Centre IPEX MHF1 "A" Name Material Finish QTY AP.12B Patch(12*12*4mm) Ceramic Clear 1 FEP Gray2

15 White LinerNITTO 5015Double Sided Adhesive

16 GreenFR4 0.5tAP.12B PCB NOTES: 1.Soldered area 2.Shielding case area 3.Double sided adhesive area. 4.All material must be RoHS compliant. 5.The connector orientation has a fixed position to the antenna as per drawing. Top Side Bottom A ALL Initial Design Sandy 2011/11/15 P/N AP.12B OD.113.J IPEX.MHFI.113 B E2 Amend Part Of The Size Sandy 2012/04/11 B Name P/N Material Finish QTY 1 AP.12F Patch(12*12*4mm) AP.12F Ceramic Clear 1 2 1.13 Coaxial Cable OD.113.CM FEP Gray 1 3 IPEX MHF1 IPEX.MHFI.113 Brass Gold 1

4 Shielding Case Tin (SPTE) Tin Plated 1

5 AP.12F PCB FR4 0.5t Green 1

6 Double Sided Adhesive NITTO 5015 White Liner 1

SPE-11-8-094/D/SS | page 10 of 11 8. Plugs Usage Precautions (1) To disconnect connectors, insert the end portion of I-PEX under the connector flanges and pull off vertically, in the direc- tion of the connector mating axis. (2) To mate the connectors, the mating axes of both connectors must be aligned and the connectors can be mated. The “click” will confirm fully mated connection. Do not attempt to insert on an extreme angle. After the connectors are mated, do not apply a load to the cable in excess of the values indicated in the diagram below. 8.I Mating / unmating

8.2 Pull forces on the cable after connectors are mated

P/N : 90192-001 RECEPTACLE PLUG RECE 2N MAX. 2N MAX. 4N MAX. Coaxial Cable

SPE-11-8-094/D/SS | page 11 of 11 9. Packaging Taoglas makes no warranties based on the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications and product descriptions at any time without notice. Taoglas reserves all rights to this document and the information contained herein. Reproduction, use or disclosure to third parties without express permission is strictly prohibited. Copyright © 2012, Taoglas Ltd.