FEATURES
APPLICATIONS
T emperature□Threshold Registers Limit Comparator Local/Remote T emperature□Registers THERM Control OVR Remote Sensing Transistor /c109 P ADC Ref Mux On-Chip□Diode T emperature□Sensor Current□Source (I ;□I )1 0 IN+ IN/c45 VDD GND A0 A1 SMBus/I C Interface
2 SCLK
SMBALERTChip□Registers Control□Logic TACH□Data Signal□Conditioning Fan□Speed□Counter PWM Control Automatic□Fan□Speed Controller +5V TACH PWM□Output PWM-MODE AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Analog Monitor and Control Circuit Notebook PCs Remote Temperature Sensor: C Accuracy, 0.125 C Resolution Network Servers Desktop PCs Local Temperature Sensor: C Accuracy, 0.125 C Resolution Telecommunications Equipment PC-Based Equipment PWM Controller DLP and LCD Projectors Frequency: 10Hz to 40kHz Duty Cycle: to 100%, Bits Automatic Fan Speed Control Loops SMBus Interface Power: to 5.5V Packages (Green): SSOP-16 (4mm 5mm) and QFN-16 (4mm 4mm) US patents pending. Please be aware that an important notice concerning availability, standard warranty, and use in critical sheet. DLP is a trademark of Texas Instruments. Pentium-IV is a trademark of Intel. JMC is a registered trademark of JMC Products. All other trademarks are the property of their respective owners. PRODUCT PREVIEW information concerns products in the Copyright 2006, Texas Instruments Incorporated formative or design phase of development. Characteristic data and other specifications are design goals. Texas Instruments reserves the right to change or discontinue these products without notice.
www.ti.com PRODUCT PREVIEW ABSOLUTE MAXIMUM RATINGS AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications. ORDERING INFORMATION (1) SPECIFIED PACKAGE TEMPERATURE PACKAGE TRANSPORT PRODUCT PACKAGE-LEAD DESIGNATOR RANGE MARKING ORDERING NUMBER MEDIA, QUANTITY AMC6821SDBQ Tubes, AMC6821 SSOP-16 DBQ C to +125 C AMC6821SDBQ AMC6821SDBQR Tape and Reel, 2500 (1) For the most current package and ordering information see the Package Option Addendum at the end of this document, or see the TI website at www.ti.com Over operating free-air temperature range (unless otherwise noted) (1) VALUE UNIT V DD to GND 0.3 to +6.5 V Digital input voltage to GND 0.3 to +6.5 V Analog input voltage to GND 0.3 to V DD 0.3 V Operating temperature range to +125 C Storage temperature range to +150 C Junction temperature J Max) +150 C (1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not implied. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW ELECTRICAL CHARACTERISTICS AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 At T A C to +100 C and V DD +3V or +5V, unless otherwise noted. AMC6821 PARAMETER CONDITIONS MIN TYP MAX UNIT TEMPERATURE MEASUREMENT T A +50 C to +100 C 0.5 2.0 C Local sensor accuracy T A C to +100 C 1.0 3.0 C T R +50 C to +100 C 0.5 1.0 C Remote sensor accuracy (1) T A C to +100 C T R C to +125 C 1.0 3.0 C Sensor resolution Both channels 0.125 C Conversion time Two channels 62.5 ms PWM CONTROLLER PWM frequency range (programmable) 40k Hz PWM frequency accuracy C to +100 C Duty cycle Programmable 100 Duty cycle resolution 8-bit 0.39 %/bit FAN RPM-TO-DIGITAL CONVERTER Accuracy C to +100 C Full-scale count 65535 Nominal input RPM 100 23000 RPM Internal clock frequency 100 kHz DIGITAL INPUT/OUTPUT Sink current mA, V DD +3V 0.4 V V OH Open-drain output low voltage Sink current 6mA, V DD +5V TBD V I OH Open-drain high-level output leakage current 0.1 µ A V IH Input high voltage 2.1 V DD 0.3 V V IL Input low voltage 0.8 V I IH Input high current µ A I IL Input low current µ A Input capacitance pF POWER SUPPLY V DD 2.70 5.25 V Normal operation 1.1 TBD mA Current Standby mode TBD µ A Power dissipation mW Operating temperature +125 C Storage temperature +150 C (1) The remote temperature sensor is optimized for the Pentium-IV thermal diode with diode ideality n MIN 1.0012, n TYP 1.0021, and n MAX 1.0030. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW SDA SCL S Sr SP tF tF tF tHD;ST A tHD;DA T tSU;DA T tSU;ST A tBUF tSU;STO MSC510 tHIGH tLOW tHD;ST A tSP tR TIMING REQUIREMENTS AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Figure Definition of Timing Specification At V DD +3V or +5V, and T A T MIN to T MAX unless otherwise noted. AMC6821 PARAMETER CONDITIONS MIN TYP MAX UNIT f SCLK Clock frequency 100 kHz t BUF Bus free time 4.7 µ s t SU;STA Start setup time 4.7 µ s t HD;STA Start hold time 4.0 µ s t SU;STO Stop condition setup time 4.0 µ s t LOW SCL low time 4.7 µ s t HIGH SCL high time 4.0 µ s t R SCL, SDA rise time 1000 ns t F SCL, SDA fall time 300 ns t SU;DAT Data setup time 250 ns t HD;DAT Data hold time 300 ns t TIMEOUT Detect clock low timeout ms Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW DEVICE INFORMATION SCLK SDA SMBALERT PWM-MODE IN+ IN/c45 PWM-OUT TACH OVR NC GND VDD THERM FAN-FAULT AMC6821 SSOP-16 (body□size:□5mm□x□4mm) TACH OVR NC GND PWM-MODE IN+ AMC6821 (Thermal□pad must□be□connected to□GND.) 5 6 7 8 16 15 14 13 V DD THERM FAN-FAULT IN /c45 PWM-OUTSCLKSDA SMBALERT QFN-16 (body□size:□4mm□x□4mm) AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 TERMINAL FUNCTIONS PIN NO. NAME SSOP QFN
DESCRIPTION
Output, open-drain. PWM output to control fan speed. TACH Input. Fan tachometer input to measure the fan speed. Digital output, open-drain, active low. Goes low when temperature reaches the critical shutdown threshold OVR or remote temperature sensor failed. (See the Interrupt section for details.) NC Not connected. Reserved for manufacturer's testing. GND System ground V DD Power supply, to +5V Digital input/output (open-drain). As an output, an active low output indicates the temperature over the THERM THERM temperature limit. As an input, the pin provides an external fan control. When the pin is pulled low by external signal, the THERM-IN bit is set, and the fan is set to full-speed. FAN-FAULT Open-drain output. Goes low when a fan failure is detected. IN Negative analog differential input. Connected to cathode of external temperature-sensing diode. Positive analog differential input. Connected to anode of external temperature-sensing diode IN+ Pentium-IV substrate transistor or general-purpose 2N3904 type transistor. Digital input, PWM mode selection. When tied low (GND), the high PWM frequency range (1kHz to PWM-MODE 40kHz) is selected. When tied to V DD or floated, the low PWM frequency range (10Hz to 94Hz) is selected. Device slave address selection pin (see the SMB Interface section for details). Device slave address selection pin (see the SMB Interface section for details). SMBALERT Digital output, open-drain, SMBALERT active low. Requires a pull-up resistor (2.2k Ω typical). SDA Bi-directional digital I/O pin, SMBus data, open-drain. Requires a pull-up resistor (2.2k Ω typical). SCLK Digital input, SMBus clock. Requires a pull-up resistor (2.2k Ω typical). Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW SMBUS INTERFACE Communication Protocols AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 The AMC6821 communicates through the serial system management bus (SMBus). The AMC6821 is connected to this bus as a slave device, under the control of a bus master. The AMC6821 has a 7-bit serial bus address, which is programmable by properly connecting the address pins and A1. Table shows the selection of the AMC6821 slave address. Table AMC6821 Address Select ADDRESS GND GND 0011000 NC (1) GND 0011010 V D GND 0011001 GND NC 0101100 NC NC 0101110 V D NC 0101101 GND V D 1001100 NC V D 1001110 V D V D 1001101 (1) NC No connection. The AMC6821 employs four standard SMBus protocols: the send byte, receive byte, write byte, and read byte. All other operations result in undefined results. Send Byte S SLAVE ADDRESS WR ACK COMMAND ACK P 7-bit AMC6821 slave address 8-bit register address S start condition; P stop condition; shaded slave to master; unshaded master to slave; WR write (bit value of 0). Receive Byte S SLAVE ADDRESS RD ACK DATA NACK P 8-bit data from the register selected 7-bit AMC6821 slave address previously S start condition; P stop condition; shaded slave to master; unshaded master to slave; RD read (bit value of 1); NACK not acknowledged. Write Byte S SLAVE ADDRESS WR ACK COMMAND ACK DATA ACK P 7-bit AMC6821 slave address 8-bit register address 8-bit data written to register S start condition; P stop condition; shaded slave to master; unshaded master to slave; WR write (bit value of 0). Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Write Multiple Bytes S SLAVE ADDRESS WR ACK COMMAND ACK DATA ACK DATA ACK 7-bit AMC6821 slave 8-bit register address of First 8-bit data written Second 8-bit data written address first register to be written first register second register DATA ACK ... DATA ACK P Third 8-bit data written third register Last 8-bit data S start condition; P stop condition; shaded slave to master; unshaded master to slave; WR write (bit value of 0). The first register is the one to which the first data byte is written. The next register is the second register. If the bus master continues to transfer data into the AMC6821 after writing the last location, all data are ignored until the operation stops. Read Byte S SLAVE ADDRESS WR ACK COMMAND ACK Sr SLAVE ADDRESS RD ACK DATA NACK P 7-bit AMC6821 slave 7-bit AMC6821 slave 8-bit data from 8-bit register address address address register S start condition; P stop condition; shaded slave to master; unshaded master to slave; WR write (bit value of 0); RD read (bit value of 1); NACK not acknowledged; Sr repeated start condition. Read Multiple Bytes S SLAVE ADDRESS WR ACK COMMAND ACK Sr SLAVE ADDRESS RD ACK DATA ACK 7-bit AMC6821 slave Address of first 7-bit AMC6821 slave 8-bit data from first address register to be read address register DATA ACK ... DATA NACK P 8-bit data from second register Last 8-bit data S start condition; P stop condition; shaded slave to master; unshaded master to slave; WR write (bit value of 0); RD read (bit value of 1); NACK not acknowledged; Sr repeated start condition. The first register is the one from which the first data byte is transmitted. The next register is the second register. If the bus master continues clocking data out after reading the last location (0x3F), the value 0x00 is sent out until the operation stops. The AMC6821 is entirely controlled by the registers. All registers are 8-bit. The AMC6821 has an address pointer register; the value of the address pointer register determines which register. To write data to the device register or read data from it, the address pointer register must be set properly. Data can then be written into or read from that register. The command issued by the bus master always contains the initial value of the address pointer register. The command is constructed as shown in Table Table Command Format (1) Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) ADDR5 ADDR4 ADDR3 ADDR2 ADDR1 ADDR0 (1) ADDR[5:0] is the address of the register that is accessed first. The register address is stored in the address pointer register. In the send byte operation, the bus master writes the address of a specified device register into the address pointer register. In the receive byte operation, the bus master reads the data back from the device register addressed by the address point register. In the write byte operation, the bus master sets the address pointer register to the address of a specified device register, then writes 8-bit data into it. In the read byte operation, the SMBus master sets the address pointer register to the address of a specified device register first, then reads 8-bit data back from it. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW SMBus ALERT RESPONSE ADDRESS (ARA) SMBus TIMEOUT POWER-ON RESET AND START OPERATION AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 In the write multiple bytes operation, the address pointer of the AMC6821 increments by '1' after the data are written, until it reaches the last register address (0x3F). If the host continues to transfer data into the AMC6821 after writing the last location, all data are ignored until the operation stops. When reading multiple bytes, the address pointer of the AMC6821 increments by '1' after transmitting the data until it reaches the last register address (0x3F). If the host continues clocking data out after reading the last location, the value 0x00 is sent out until the operation stops. The alert response address is a feature of SMBus devices that allows an interrupting device to identify itself to the host when multiple devices issue simultaneous interrupts. The SMBALERT pin is an open-drain interrupt output pin. When the AMC6821 issues an interrupt request, the following procedure occurs: SMBALERT is pulled low. The bus master sends an alert response address or ARA (ARA 0001100), and initiates a read operation, as shown in Table The AMC6821 responds to the ARA by sending the slave address back. The 7-bit device slave address is placed in the seven most significant bits of the byte; the last bit is '0'. The master receives the AMC6821 slave address and starts the interrupt service. If more than one device pulls the SMBus low, the highest priority (lowest slave address) device wins the communication right via standard arbitration during the slave address transfer (refer to the SMBus specification version 2.0 for details). To service the interrupt request of the AMC6821, the master must read the status register. Most interrupt source bits in the status registers are cleared after reading the status register, and are reasserted if the error condition still exists on the next monitoring cycle. The SMBALERT only clears if the interrupt has been resolved. Table ARA Operation S ALERT RESPONSE ADDRESS RD ACK DATA NACK P 00001100 7-bit MSB: slave address of AMC6821 LSB S start condition; P stop condition; shaded slave to master; unshaded master to slave; RD read (bit value of 1); NACK not acknowledged. The AMC6821 has a programmable SMBus timeout function. If the timeout function is enabled (when a single clock is held low longer than 30ms 10%), the AMC6821 releases the bus (stops driving the bus and lets SCLK and SDA float high), resets the communication, and is able to receive new START conditions. If the timeout function is disabled (when the clock resumes after being held low for longer than 30ms), the AMC6821 continues the bus communication at the current point. To disable the timeout function, set the bit TODIS (bit of Configuration Register to '1'. To enable this function, clear the bit TODIS to '0'. After power-on or reset, TODIS is cleared and the timeout function is enabled. After power-on, all registers are set to the power-on default values. The device does not perform any monitoring functions until the START bit of Configuration Register is set ('1'). No detections are executed until the first monitoring cycle is completed, and all measurement data registers (such as remote and local temp-data registers and the TACH data register) are updated with the new measured value. No interrupt signals are generated until the first cycle of monitoring and detection is completed. This process avoids any false alarms caused by the power-on default setting. After power-on, the fan spin-up process is performed. At the end of spin-up, the duty cycle of the PWM driver is adjusted to 33%. (Refer to the Fan Spin-Up section for details). Device status after software reset is similar to power-on reset. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW APPLICATION INFORMATION ADC CONVERTER ADCMux Digital Filter LPF□and Signal□Conditioning Data Registers 60kHz TEMPERATURE SENSOR /C0068V BE /C0043KT q /C0032In(N ) (1) ADC□and Signal ProcessingMux Local T emperature Registers LPF□and Signal□Conditioning SW1 SW2 I1 I2 Diode T emperature Sensor AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 The AMC6821 has an 11-bit, on-chip analog-to-digital converter (ADC), as shown in Figure This ADC converts the analog input into digital format. The analog input is passed through front-end signal conditioning circuitry to remove the noise. The resulting signal is then converted by the ADC. To further reduce the effects of noise, digital filtering is performed by averaging the results of measurement cycles. After digital filtering, the newest result is stored in the temperature data register (low byte and high byte) in two s complement format. The ADC stops when the START bit of Configuration Register is cleared ('0') and runs when START Figure On-Chip Analog-to-Digital Converter The AMC6821 has an integrated temperature sensor (shown in Figure to measure the ambient temperature, and one remote diode sensor (such as a Pentium thermal diode) input to measure external (CPU) temperature. The measurement relies on the characteristics of a semiconductor junction operation at a fixed current level. The forward voltage of the diode BE depends on the current through it and the ambient temperature. The change in V BE when the diode is operated at two different currents, I and I is shown in Equation Where: k is Boltzmann s constant, q is the charge of the carrier, T is the absolute temperature in degrees Kelvin, and N is the ratio of the two currents. Figure Integrated Local Temperature Sensor Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW ADC□and Signal ProcessingMux Remote T emperature Registers LPF□and Signal□Conditioning SW1 SW2 I1 I2 Bias□Diode IBIAS IN+ IN/c45 Substrate Sensing Transistor uP READING Temperature Data AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 APPLICATION INFORMATION (continued) The remote sensing transistor can be a substrate transistor built within the microprocessor (as in a Pentium-IV), or a discrete small-signal type transistor. This architecture is shown in Figure The internal bias diode biases the IN terminal above ground to prevent the ground noise from interfering with the measurement. An external capacitor (up to 1000pF) may be placed between IN+ and IN to further reduce the noise from interfering. Figure Remote Temperature Sensor The analog sensing signal is pre-processed by a low-pass filter and signal conditioning circuitry, then digitized by the ADC. The resulting digital signal is further processed by the digital filter and processing unit. The final result is stored in the local temperature data register and remote temperature data register, respectively. The 8MSBs are stored in the corresponding Temp-DATA-HByte register, and the 3LSBs are stored in the Temp-DATA-LByte register. Refer to the Temperature Data Registers section for details. The format of the final result is in two s complement; see Table It should be noted that the device measures the temperature from C to +125 although the code represents temperatures from 128 C to +127 Parasitic resistance (seen in series with the remote diode) to the IN+ and IN inputs to the AMC6821 is caused by a variety of factors, including printed circuit board (PCB) track resistance and track length. This series resistance appears as a temperature offset in the remote sensor temperature measurement, and causes more than 0.5 C error per ohm. The AMC6821 is implemented with a TI-patented technology to automatically cancel out the effect of this series resistance, giving a more accurate result without the need for user-characterization of this resistance. It is important to note that temperature can be read by an 8-bit value (with C of resolution) from the Temp-DATA-HByte register, or as an 11-bit value (with 0.125 C of resolution) from the Temp-DATA-LByte and Temp-DATA-HByte registers. If only C of resolution is required, the temperature readings can be read back at any time and in no particular order. If reading the 11-bit measurement is required, the process involves a two-register read for each measurement. To get an 11-bit result of the remote sensor, the controller must read the Temp-DATA-LByte register (0x06) first, and the Remote-Temp-DATA-HByte register (0x0B) second to complete the reading. However, to get bit of the local sensor only, or to get both local and remote sensors, the controller must read Temp-DATA-LByte first, Local-Temp-DATA-HByte (0x0A) second, and Remote-Temp-DATA-HByte third. This method causes all associated temperature data registers to be frozen until the Remote-Temp-DATA-HByte register has been read. This process also prevents the high byte data from being updated while the three LSBs are being read, and vice-versa. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW Temperature Out-of-Range Detection AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 APPLICATION INFORMATION (continued) Table Temperature Data Format TEMPERATURE BINARY DIGITAL CODE (11 bits) +127 01111111000 +125 01111101000 +100 01100100000 +75 01001011000 +50 00110010000 +25 00011001000 +10 00001010000 00000001000 00000000000 11111111000 11100111000 11001110000 10110101000 100 10011100000 125 10000011000 128 10000000000 The AMC6821 has the following temperature limitation detections: High and Low Temperature Limit: The value of the High-Temp-Limit and Low-Temp-Limit registers specify the remote or local temperature ranges of normal operation. When the local or remote temperatures are equal to or above the value of the corresponding High-Temp-Limit register, the LTH or RTH bits in the status register are set ('1'). Likewise, when the local or remote temperatures are less than or equal to the corresponding Low-Temp-Limit register, the LTL or RTL bits in the status register are set ('1'). When the local temperature is out-of-range (LTH or LTL 1), the local temperature out-of-range event occurs. The LTO bit in the status register is set ('1'), and the LTO interrupt is generated via the SMBALERT pin if it is enabled (the LTOIE bit of Configuration Register is set). Similarly, when the remote temperature is-out-of range (RTH or RTL 1), the remote temperature out-of-range event occurs. The RTO bit in the status register is set ('1'), and the RTO interrupt is generated via the SMBALERT pin if it is enabled (the RTOIE bit of Configuration Register is set). Critical Limit: Critical temperature limit is the highest allowed temperature of remote or local temperature. When the temperature is greater than or equal to the corresponding critical temperature, the LTCT or RTCT bit of the status register is set ('1'), the output of the OVR pin goes low, and a non-maskable interrupt is generated through the SMBALERT pin (low). Passive Cooling Temperature (PSV) Limit: This limit defines the threshold of the passive cooling. In the auto temperature fan control mode, the system enters a passive cooling condition when the active control temperature is equal to or below this limit, and the fan stops. In passive cooling, the LPSV bit of Status Register (0x03) is set ('1'), and a PSV interrupt is generated on the SMBALERT pin if enabled (PSVIE 1). Note that reading the Status Register clears the LPSV bit. After reading, if the active control temperature remains equal to or below the PSV temperature, this bit reasserts on next monitoring cycle. THERM Limit: This limit is an additional fail-safe threshold. When the local or remote temperature is equal to or above this limit, the corresponding L-THERM or R-THERM bit is set ('1'), and the THERM pin is asserted low, which can be used to throttle the CPU clock. Furthermore, the THERM interrupt is generated on the SMBALERT pin if enabled (THERMOVIE 1). Reading the Status Register clears the R-THERM and L-THERM bits. Once cleared, these bits are not reasserted until the temperature falls C below the THERM limit, even if the THERM condition persists. If the THERM-FAN-EN bit of the Configuration Register is set ('1'), L-THERM or R-THERM forces the fan to run at full-speed. When THERM-FAN-EN the status of the L-THERM and R-THERM bits do not affect the fan speed directly. Note that the THERM limit can be lower or higher than other temperature limits. For example, if the THERM limit is lower than the PSV temperature limit, then the CPU clock can be throttled while the cooling fan is off. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW Local-High-T emp-Limit Local□T emperature Local-Low-T emp-Limit Remote-High-T emp-Limit Remote□T emperature Remote-Low-T emp-Limit Loca-Critical-T emp Local□T emperature Remote-Critical-T emp Remote□T emperature Active□Control□T emperature PSV-T empT L-THERM□Limit Local□T emperature R-THERM□Limit Remote□T emperature LTOIE RTOIE PSVIE THERM-FAN-EN THERMOVIE THERM-FAN-EN THERMOVIE LTO□Interrupt Pin□Low SMBALERT RTO□Interrupt Pin□LowSMBALERT OVR Pin□Low SMBALERT Pin□Low OVR Pin□Low SMBALERT Pin□Low PSV□Interrupt Pin□LowSMBALERT Assert Pin□LowTHERM Force□Fan□to□Full-Speed Local□Therm□□Interrupt Pin□Low SMBALERT Assert Pin□LowTHERM Force□Fan□to□Full-Speed Remote□Therm□Interrupt Pin□Low SMBALERT LTH LTL LTO RTH RTL RTO LTC□Bit□in□Status□Register□2 RTC□Bit□in□Status□Register□2 LPSV□Bit□in□Status□Register□2 R-THERM□Bit□in□Status□Register□1 L-THERM□Bit□in□Status□Register□2 AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Figure Temperature Out-of-Range Detection Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW Remote Temperature Sensor Failure Detection PWM Output +5V PWM-Out ON PWM Control AMC6821 PWM-EN PWMINV□=□0□(default)□for□driving□the□PMOS. +5V PWM-Out ON PWM Control AMC6821 PWM-EN PWMINV□=□1□for□driving□the□NMOS. PWM WAVEFORM SETTING RPM□reduces□as□the duty cycle□decreases. Period ON OFF AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 The remote temperature sensor failure detection determines whether the remote sensor diode has an open-circuit condition, short-circuit to ground, or a short-circuit (IN+) to (IN condition. This fault detection is based on the analog input voltage and is not checked until the first monitoring cycle is completed after power-on. Reading the fault sensor returns a value of 128 C (0x80). Since the power-on default value of the temperature data registers is 0x80 128 C), a reading of 0x80 from the temperature data register immediately after power-on does not indicate a diode fault condition. The remote temperature sensor failure can be only checked after the first monitoring cycle has completed after power-on. When a remote sensor failure occurs, the remote sensor failure bit (RTF in the Status Register) is set to '1', the OVR pin is forced low, and an RTF interrupt is generated through the SMBALERT pin if the interrupt is enabled (RTFIE 1). Once this interrupt is generated, the RTF bit remains '1' and the OVR pin stays low until a power-on reset or software reset is issued, whether or not the failure condition persists. The PWM-Out pin is an open-drain output. When PWM-EN of Configuration Register is cleared ('0'), the PWM-Out pin is disabled and goes into a high-impedance status. When PWM-EN is set ('1'), the PWM-Out pin is enabled to drive the fan. When enabled, the status of the PWM-Out pin is determined by the PWM duty cycle and phase bits (PWMINV of Configuration Register When PWMINV (default), the PWM-Out pin goes low for 100% duty cycle (suitable for driving the fan using a PMOS FET). Setting PWMINV to '1' makes the PWM-Out pin go high (with an external pull-up resistor) for a 100% duty cycle. This setting is used to drive an NMOS-power FET. Figure PWM Output PWM frequency and duty cycle are programmable. The value of the DCY Register defines the duty cycle: it has 8-bit resolution, 1LSB corresponding to (0.392%). Writing 0x00 sets the duty cycle to 0%; writing 0xFF sets the duty cycle to 100%. PWM frequency has two ranges: the high range is from 1kHz to 40kHz, and the low range is from 10Hz to 94Hz. The PWM-MODE pin status determines which range is selected. When the PWM-MODE pin is tied to ground, the high range is selected. Otherwise, the low range is selected. Bits [PWM2:PWM0] in the Fan Characteristics Register define the frequency; see Table The resolution of the PWM waveform period is 0.312 µ corresponding to a 3.2MHz clock. The default value after power-on is 30Hz when the low range is selected, or 25kHz when the high range is selected. Figure PWM Waveform (PWMINV Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW FAN SPEED MEASUREMENT AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Table PWM Frequency PWM2 PWM1 PWM0 PWM FREQUENCY When the PWM-MODE Pin is Floating or Tied to V DD 10Hz 15Hz 23Hz 30Hz (default) 38Hz 47Hz 62Hz 94Hz When the PWM-MODE Pin is Tied to GND 1kHz 10kHz 20kHz 25kHz (default) 30kHz 40kHz 40kHz 40kHz The AMC6821 monitors the fan speed (RPM) via the TACH pin Figure illustrates this process). The TACH-EN bit of Configuration Register (bit 0x01) enables the fan speed measurement. When TACH-EN is cleared ('0'), the measurement is disabled. The measurement is enabled when the TACH-EN bit is set to '1'. This section describes the device behavior when TACH-EN is set ('1'). The on-chip fan-speed counter does not count the fan tach output pulses directly because of the low RPM of the fan. Instead, the period of the fan revolution is measured by gating an on-chip clock (100kHz). The result is stored in the TACH-DATA Register that contains two bytes (16 bits total). RPM monitoring is disabled when the START bit of Configuration Register or the TACH-EN bit of Configuration Register is cleared ('0'), and is enabled when START and TACH-EN If the TACH-MODE bit is cleared, RPM monitoring stops and the TACH-DATA register is not updated when the duty cycle is less than 7%. If the TACH mode is equal to '1' the RPM monitoring is always performed, and the TACH data are always updated after each monitoring. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW TACH-DATA Register RPM□= (10000□x□60) (Value□of□TACH-DATA□Register) (2) Clock Measurement□Period□for□4□Pulses□Per□Revolution TACH□Pulse PWM Measurement□Period for□2□Pulses/Revolution TACH□Pulse Measurement Starts Clock Measurement□Period□for□4□Pulses□Per□Revolution Measurement□Period for□2□Pulses/Revolution RPM□Measurement□for□TACH-MODE□=□0 RPM□Measurement□for□TACH-MODE□=□1 b)□Measuring□the□Period□of□TACH□Pulses□to□Determine□the□Fan□Speed Signal□Conditioning FAN□Speed□Counter TACH PWM Control PWM-Out TACH□Data TACH Output +5V +5V START TACH-EN AMC6821 a)□Block□Diagram□of□Fan□Speed□Monitoring AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Two fan tach pulse periods (PSPR or four tach pulse periods (PSPR are measured and the result is stored in the TACH-DATA Register as shown in Figure Counting stops if the counter is over-range; the measurement cycle repeats until monitoring is disabled, and the fan speed (RPM) can be calculated as shown in Equation Reading the TACH Data Register To read the fan speed, both TACH-DATA-LByte and TACH-DATA-HByte must be read. TACH-DATA-LByte must be read first. This reading causes TACH-DATA-HByte to be frozen until both the high and low byte registers have been read from; this method prevents erroneous TACH readings. RPM Measurement Rate The TACH-FAST bit of Configuration Register determines the rate. When TACH-FAST the TACH-DATA Register is updated every 250ms (fast monitoring). When TACH-FAST (default), the reading is updated every second (standard monitoring period). Select Number of Pulses/Revolution The speed sensor of most common fans provides two or four TACH pulses per revolution. The PSPR bit of Configuration Register specifies how many pulses per revolution are generated. PSPR indicates four pulses/revolution and PSPR (default) indicates two pulses/revolution. TACH Mode Selection The TACH-MODE bit of Configuration Register specifies the TACH pulse output mode of the fan. Some fans (such as three- and two-wire) are powered directly by the PWM, and must be PWM-On to provide a TACH pulse output. When the PWM-Out pin switches these fans ON/OFF directly, the PWM-Out must be kept ON to power the fan during the measurement. In this case, the TACH-MODE bit of Configuration Register must be cleared ('0'). When TACH-MODE the PWM-Out pin is kept ON during the measurement period. Clearing the TACH mode ('0') also enables the internal correction circuitry to correct the error caused by the extra duty cycle applied in the measurement period. The power-on default value of the PWM mode is Figure Fan Speed Measurement Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW RPM□Alarm (TACH□is□less□than□the□high□limit) (RPM□out-of-range) FANIE (FAN-TACH□interrupt□enabled) FANS (TACH□is□greater□than□the□low□limit) FAN-ORN□Interrupt AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Some fans (such as the four-wire fan from JMC are powered directly by dc power, instead of being powered by the PWM. In this case, the TACH mode must be set to '1'. When TACH-MODE the PWM-Out pin is not forced ON; instead, the status is controlled completely by the DCY register, just as in normal operation. Setting TACH-MODE to '1' also disables the internal correction circuit because no extra duty cycle is applied. Setting the TACH mode to '1' allows TACH reading continuously, regardless of the status of the PWM-Out pin. The selection of the TACH mode affects the RPM monitoring and control. When the TACH-MODE bit is equal to '1', the duty cycle of the PWM-Out pin is always determined by the calculated value; the TACH data are always updated at every RPM monitoring. However, when the TACH-MODE bit is equal to '0', in the Software-RPM Control mode the PWM-Out pin is forced to 30% if the calculated duty cycle is less than 30%; in other modes, the PWM-Out pin is forced to and the TACH data is not updated if the calculated duty cycle is less than 7%. FAN RPM Out-of-Range Detection The larger value of the TACH data corresponds to a slower speed. When the TACH data are larger than the TACH-Low-Limit, the fan runs at a speed below the predefined minimum RPM, and the FANS bit in Status Register is set to '1'. Note that no FANS (fan-slow) detections are made during spin-up. The FANS bit is cleared ('0') only after reading this register and reasserted ('1') in the next monitoring if a fan-slow is detected. After spin-up, FANS is set ('1') even if the TACH data are less than the TACH-Low-Limit until the register is read. When the TACH data are less than the TACH-High-Limit, the fan runs at a speed above the predefined maximum RPM, and the RPM-ALARM bit in Status Register is set ('1'). Note that the RPM-ALARM bit is cleared when reading the register. Once cleared, this bit is not reasserted in the next monitoring cycle even if the condition persists. This bit may be reasserted only if the RPM drops below the allowed maximum speed. When FANS or RPM-ALARM there is a fan-out-of-range interrupt and FAN-ORN is generated if the FANIE bit in Configuration Register is set ('1'). This interrupt makes the SMBALERT pin go low. Figure RPM Out-of-Range Detection Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW FAN FAILURE DETECTION During□Spin-Up□Process Normal□Operation□of□Fan□Failure Detection□and□Spin-Up Bit□FANS□=□0 Clear□Spin-Up Time□Counter TACH□Data >□Low□Limit Measure□RPM Yes Yes No No No No Yes Yes No□Spin-Up□if□Disabled Bit□FANS□=□1 Spin-Up□Time□Count□+1 Spin-Up□Process Spin-Up□Time□Count 5/c179 Fan□failure, pin goes□low. FAN-FAULT Spin-Up□Disabled? Measure□the□RPM□continuously□once□every□0.25s□(TACH-FAST =□1)□or□1sbit (TACH-FAST□=□0), even□after□a□fan□failure.□However,□there□are□no□FANS□detections□during□spin-up. The pin□is□negated□if□the□fan□returns□to□a□normal□RPM□range. FAN-FAULT AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 When the TACH data are larger than the TACH low limit, the fan runs at a speed below the predefined minimum RPM. When this condition occurs, a spin-up process is applied to start the fan again when spin-up is enabled. Bits [STIME2:STIME0] of the Fan Characteristics Register define this time period. Figure shows the function of the fan failure detection. The fan speed is measured immediately after spin-up and the TACH-FAST bit of Configuration Register determines the monitoring rate. If the fan does not return to a normal range after five consecutive spin-ups, a FAN-FAILURE occurs, the FAN-FAULT pin goes low when it is enabled (the FAN-FAULT-EN bit of Configuration Register is set), and the spin-up process continues. If the fan returns to a normal speed range before the fifth spin-up, the FAN-FAULT pin does not go low even though the FANS bit is still set to '1'. No FANS (fan-slow) detections are performed during spin-up. Figure 10. Fan Failure Detection and Spin-Up Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW PWM_OUT 2s 2s 2s TACH/AIN INT FAN_FAULT Full-Speed Continuing TACH□Failure Status□Register□Read□to□Clear□Interrupt Fourth□TACH□Failure Fifth□TACH FailureThird□TACH□Failure FAN-FAULT PIN FAN-FAULT 10k/c87 AMC6821 Fan□Failure (below□minimum□speed after□fifth□spin-up) Pin□is□Enabled (F AUL -EN□bit□=□1)AN-F T AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 The SMBALERT pin continues to generate interrupts after the assertion of the FAN-FAULT pin because the tach measurement continues even after a fan failure. Should the fan recover from the failure condition, the FAN-FAULT pin signal is negated and the fan returns to normal operating speed. Figure shows the operation of a FANS interrupt. Figure 11. Operation of the FAN-FAULT Pin with a Spin-Up Time Seconds INT is a Fan-Slow (FANS) Interrupt Through the SMBALERT Pin) The FAN-FAULT pin is an open-drain output pin, as shown in Figure When the FAN-FAULT-EN bit of Configuration Register is cleared ('1'), this pin is disabled and is always in a high-impedance status. When FAN-FAULT-EN the pin is enabled and the status indicates a fan-failure. The pin asserts low when a fan failure occurs. FAN-FAULT is negated when the fan returns to normal speed. Figure 12. FAN-FAULT Pin Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW FAN CONTROL THERM Pin and External Hardware Control THERM THERM-FAN-ENDrive□Fan□at Full-Speed (Drive□fan□at□full-speed□when THERM-IN□=□1) THERM-IN□bit Output Latch Set Reset L-THERM□Bit (Set□to ‘1’ when□the□local□temperature□is greater□than□the□Local-THERM-Limit.) R-THERM□Bit (Set□to ‘1’ when□the□remote□temperature□is greater□than□the□Remote-THERM-Limit.) Local□temperature□is□less□than□(Local-THERM-Limit 5 C)/c45 /c176 Output Latch Set ResetRemote□temp (Remote-THERM-Limit 5 C)erature□is□less□than /c45 /c176 AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 The THERM pin is a bi-direction I/O, as shown in Figure THERM Pin As An Output As an open-drain output, the THERM pin is the indicator of temperature over the THERM limit. When the remote temperature exceeds the Remote-THERM-Limit, or when the local temperature is greater than the Local-THERM-Limit, the THERM pin goes low and remains low until the measured temperature falls C below the exceeded THERM limit. Figure 13. Structure of the THERM Pin Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW Status□Register□Read THERM□Limit T emperature THERM INT SMBALERTvia INT SMBALERTvia 5/c176 AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 When the THERM limit is exceeded, the corresponding status flag bit (R-THERM or L-THERM of Status Register or Status Register is set to '1', and the THERM interrupt through the SMBALERT pin is generated if it is enabled (THERMOVIE of bit Configuration Register is set to '1'). This interrupt forces the SMBALERT pin low. Reading the status registers clears the flag bit (R-THERM and L-THERM). Clearing the flag bit makes the SMBALERT pin go back to high, but does not negate the THERM pin. It remains low until the temperature falls C below the exceeded THERM limit. After this bit is cleared, the active flag bit (R-THERM for remote temperature or L-THERM for local temperature) and the THERM interrupt are not re-armed until the temperature falls C below the exceeded THERM limit. This procedure is shown in Figure Figure 14. Operation of the THERM Interrupt and the THERM Pin When working as an output, the status of the THERM pin affects the RPM fan. If the THERM-FAN-EN bit is set ('1'), the fan goes to full-speed (that is, the duty cycle is 100%) when the THERM pin goes low. However, when THERM-FAN-EN the status of the THERM pin does not affect the fan speed. THERM Pin As An Input When this pin works as input, it is the input of the external hardware control signal; the THERM-IN bit of Status Register reflects the input. When the THERM pin is pulled low as an input, THERM-IN is set ('1') and the fan is driven at full speed (that is, the duty cycle is 100%), no matter what THERM-FAN-EN is. The THERM-FAN-EN bit has no effect when the THERM pin works as an input. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW Fan Spin-Up Normal Control DCY 100%
0 T /3 SPIN-UP TSPIN-UP
33.3% AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 The PWM duty cycle controls the cooling fan speed. To spin-up a fan from a stop or under-speed status, the spin-up process is applied to overcome the fan inertia. During the first third of spin-up, the duty cycle of the PWM gradually increases from 33.3% to 100%, and then maintains at 100% through the rest of the process. At the end of the spin-up process, the duty cycle is adjusted to 33.3%. After starting, the fan speed is controlled normally. The spin-up process is shown in Figure The bits [STIME2:STIME0] (bits 2:0 of 0x20) define the spin-up time, from 0.2 seconds to seconds, as shown in Table Fan speed is monitored immediately after the spin-up process. Spin-up is disabled by setting the FSPD bit of the Fan Characteristics Register to '1'. If disabled, the spin-up process is not applied when the fan stops or an RPM is detected below the minimum speed. The TACH low limit register defines the minimum speed. Note that no FANS (fan-slow) detections are performed during spin-up. This bit is cleared ('0') only after reading it, and reasserts '1' in the next monitoring if a fan-slow condition is detected. After spin-up, FANS is set ('1') even if the TACH data are less than the TACH low limit until the flag is read. Figure 15. Spin-Up Process Table Spin-Up Time STIME2 STIME1 STIME0 SPIN-UP TIME (seconds) 0.2 0.4 0.6 0.8 Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW Normal Fan Speed Control TACH□Setting Register DCY Adjustment Fan□Speed Counter +V TACH PWM-Out TACH□Data AMC6821 /c45 PWM Control The□PWM□duty□cycle□increases□if□the ACH□data□is□aboveT the□setting□value,□decreases□if□the□TACH□data□is□below the□setting,□and□does□not□change□if□the□TACH□data□is equal□to□the□setting□(with□a□tolerance□of□0x000A). AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 The fan speed is controlled by four different modes: software DCY control; software RPM control, auto remote temperature fan control; maximum fast-speed calculated control. Bits FDRC1 and FDRC0 in Configuration Register determine the operation mode. Software DCY Control Mode When the bits [FDRC1:FDRC0] [00] the fan works in the software DCY control mode. The host writes the desired duty cycle value corresponding to the required RPM into the DCY register. In this mode, if the TACH measurement is enabled (bit of 0x01 and the TACH-MODE bit (bit of 0x01) is cleared ('0'), the duty cycle from the POW-OUT pin is forced to when the value in the DCY register is less than 7%. However, if the TACH measurement is disabled (bit of 0x01 is cleared) or the TACH mode is set ('1'), the DCY register always keeps the programmed value written by the host and is not forced to '0' even when the programmed value is less than 7%. Software-RPM Control Mode This mode is used to maintain the fan at a fixed target speed. It works only when the TACH measurement is enabled (bit of 0x02 1). When the bits [FDRC1:FDRC0] [01] the fan works in the software RPM control mode, as shown in Figure The host writes the proper value into the TACH Setting Register to set the target fan speed. The actual fan speed is monitored by an on-chip fan speed counter, and the result is stored in the TACH-DATA Register (refer to the Fan Speed Measurement section for more details). The actual speed is compared with the setting value. If there is a difference, the duty cycle is adjusted. Figure 16. Software RPM Control The monitoring and adjustment is made once every second, or once every 250ms, as determined by the TACH-FAST bit of Configuration Register (bit 0x04). Bits [STEP1:STEP0] of the DCY-RAMP Register define the allowed amount of each adjustment. When the difference between the values of the TACH-DATA and TACH Setting Registers are equal to or less than 0x000A, the adjustment finishes. 0x000A corresponds to about 1.8% tolerance for 10000RPMs, or 0.9% for 5000RPMs. This measurement architecture is illustrated in Figure In practice, the selected target speed must be not too low to operate the fan. When the TACH-MODE bit (bit of 0x02) is cleared ('0'), the duty cycle of PWM-Out is forced to 30% when the calculated desired value of duty cycle is less than 30%. Therefore, the TACH setting must be not greater than the value corresponding to the RPM for 30% duty cycle. When TACH mode is equal to '1', the TACH setting must not be greater than the value corresponding to the allowed minimum RPM at which the fan runs properly. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW (TACH-DATA□Register) T/c45 ACH-SETTING□Register) Yes No Yes(T )□>ACH-DATA (TACH-SETTING) Increase□DCY by□one□STEP Decrease□DCY by□one□STEP Measure□RPM□and□adjust□DCY□once□every□second□(TACH-FAST□=□0) or□once□every□250ms□(T =□1).ACH-FAST T emperature-to-DCY Adjustment AMC6821 Actual□T emperature The□DCY -RAMP□Register determines the□speed□of□adjustment. temperature PWM□Control T emperature Channel AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Figure 17. RPM Fan DCY Loop Auto Temperature Fan Mode The AMC6821 has two auto temperature fan control modes. When the bits [FDRC1:FDRC0] [10] (default), the fan is in the auto remote fan temperature control mode. The temperature reading from the remote temperature sensor is the active control temperature that controls the PWM duty cycle. When the bits [FDRC1:FDRC0] [11], the fan is in the maximum fast-speed calculated control mode. The local temperature and the remote temperature have independently-programmed control loops with different parameters. In the maximum fast-speed calculated control mode, the required fan speed is calculated for the remote and local channels, respectively. Whichever control loop calculates the fastest speed based on the measured temperature drives the fan. After start-up, the PWM duty cycle is determined by the actual control temperature. When the temperature is above the low temperature and below the high temperature, the internal control loop automatically adjusts the duty cycle to a proper value according to the measured temperature. When the temperature rises, the duty cycle increases to a higher value; when the temperature drops, the duty cycle reduces. This architecture makes the fan always run at an optimal speed. This adjustment is based on the control-loop parameters defined in the Local TEMP-FAN Control Register Remote TEMP-FAN Control Register and the DCY-RAMP Register Changing the parameters changes the desired value of the duty cycle and the fan speed. Figure 18. Auto Fan Temperature Loop Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW High Temperature/C0043(Low Temperature)/C0041(100 /C0042Value of DCY−LOW−TEMP Register) Slope (3) Normal□Range DCY -LOW-TEMP (DCY□at□Low□T emperature, Default□is□33%) 100% LOW-TEMP□(Low□T emperature) High T emperature RPM□=□0 Actual□□T emperature Critical-T emp PSV-T emp (Passive□Cooling□T emperature) Low-T emp-Limit High-T emp-Limit Out-of-Range Out-of-Range THERM-Limit T emperature-to-DCY□Adjustment□Range DCY□increases□when□the□temperature□rises. DCY□decreases□when□the□temperature□reduces.0% Duty□Cycle AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 The bits [R-TEMP4:R-TEMP0] of the Remote TEMP-FAN Control Register and the bits [L-TEMP4:L-TEMP0] of the Local TEMP-FAN Control Register are the low temperature bits that define the low temperature of the control loops. Bits [SPL2:SPL0] of these registers are the slope bits that define the increment of the duty cycle when the temprature increases The bits [RATE2:RATE0] of the DCY-RAMP Register (bits [4:1], 0x23) specify the updating rate of the duty cycle in the temp-fan control mode, and the bits [STEP1:STEP0] define how much the duty cycle is adjusted by each updating. The high temperature can be calculated by Equation Figure 19. Active Control Temperature PWM Duty Cycle When the active control temperature is equal to or below the corresponding low temperature, the duty cycle is equal to the value of the DCY-LOW-TEMP Register and the fan runs at a predefined minimum speed. When the control temperature is equal to or higher than the corresponding high temperature, the PWM duty cycle is set to 100% and the fan runs at full-speed. When the active control temperature is equal to or below the corresponding value of the PSV-Temp Register (the predefined passive cooling temperature), the fan stops and the PWM duty cycle is set to When the actual duty cycle is different from the desired value, the duty cycle is adjusted automatically. When the RAMPE bit of the DCY-RAMP Register is cleared ('0'), the duty cycle changes to the desired value immediately after being calculated. When the RAMPE bit is '1', the duty cycle changes to the new value gradually. The DCY-RAMP Register specifies how quickly the duty cycle changes. The duty cycle can be checked every 0.0625 of a second to every eight seconds, depending on the bits [RATE2:RATE0] bits. It changes 1/255(0.392%) to (1.57%) each time, depending on the bits [STEP1:STEP0] bits. When the difference between the actual value and the desired value is equal to or less than the adjustment threshold (as defined by the bits [THRE1:THRE0] bits), the adjustment finishes. See the DCY-RAMP Register for details. When the TACH monitoring is enabled (TACH-EN bit, bit of 0x02, is set to '1') and the TACH-MODE bit (bit of 0x02) is cleared ('0'), the duty cycle is forced to when the calculated value is less than 7%. If the TACH monitoring is disabled (TACH-EN or the TACH-MODE bit is set ('1'), the duty cycle is always set to the calculated value even if the value is less than 7%. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW Read□Local T emperature No Yes LTH□=□1, LTO□=□1 Yes No No T emperature/c179 Local-Critical-T emp LTC□=□1, is□LowOVR LTL□=□1, LTO□=□1 Yes RTL□=□1, RTO□=□1 Yes Read□Remote T emperature RTH□=□1, RTO□=□1 Yes No RTC□=□1, OVR is□Low Yes NoNo (Update□DCY□with□the□rate□defined□by□the bits□[RATE2: 0]□of□the□DCY□ramp□register.RATE T emperature/c179 Remote-Critical-T emp T emperature/c179 Remote-High-T emp-Limit T emperature/c163 Local-Low-T emp-Limit T emperature/c179 Local-High-T emp-Limit T emperature/c163 Remote-Low-T emp-Limit Calculate□New□DCY□for□the□Remote Fan□T emperature□Control Yes Calculate□DCY□for□the□remote□fan□temperature□control and□local□fan□temperature□control,□respectively. Use□the□larger□one□as□the□new□DCY . No Remote□Fan□T emperature□Control□Mode Update□DCY (Remote□Fan□T emperature□Control) (Maximum□fast□speed□calculated□control) Update□DCY? Yes No The□temperature□updating□rate□may□be□faster□than□the□DCY□updating□rate. AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Figure 20. Temperature Monitoring Flow Chart Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW INTERRUPT OVR OVREN AMC6821 Output Latch Set Reset LTC□Bit (Local□temperature□reaches□the□critcal□shutdown□threshold.) Local□T emperature□<□(Local-Critical-T emp 5 C)/c45 /c176 Output Latch Set Reset RTC□Bit (Remote□temperature□reaches□the□critcal□shutdown□threshold.) Remote□T emperature□<□(Remote-Critical-T emp 5 C)/c45 /c176 RTF (Remote□T emperature□Sensor□Failure) T emperature□Back□in□Limit (status□bit□stays□set) High□Limit T emperature Status□Bit SMBALERT Cleared□on□Read (T emperature□below□limit) OVR Pin AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 The AMC6821 provides two interrupt output pins, OVR and SMBALERT Figure shows the function of the OVR pin and Figure illustrates the function of the SMBALERT pin. Figure 21. OVR Pin Figure 22. SMBALERT Pin and Status Bits Behavior OVR is an open-drain output pin that works as an over-critical temperature limit (shutdown threshold) indicator and remote sensor failure indicator. Setting the OVREN bit of Configuration Register to '1' enables this pin; clearing OVREN ('0') disables it. When disabled, the OVR pin is in a high-impedance status. When enabled, the status is controlled by the over-critical temperature flag and remote sensor failure flag bits of the Status Registers. When the temperature is over the critical limit (shutdown threshold), the corresponding over-critical limit flag of the Status Register (RTC for the remote channel and LTC for the local channel) is set ('1'). This flag is cleared ('0') when reading the Status Registers. Once cleared, this bit is not reasserted until the temperature falls C below the exceeded critical limit, even if the over-critical limit condition persists. When the temperature is equal to or above the critical temperature limit, the OVR pin is asserted (active low) to indicate this critical condition. As the over-critical temperature limit indicator, the OVR pin remains low once asserted until the measured temperature falls C below the exceeded critical limit. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW SMBALERT Pin SMBALERT Interrupt Behavior T emperature□Back□in□Limit (status□bit□stays□set) High□Limit T emperature Sticky□Status□Bit SMBALERT Interrupt Disabled Interrupt□Enabled ( Rearmed)SMBALERT Cleared□on□Read (temperature□below□limit) HANDLING SMBALERT INTERRUPTS AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 When a remote temperature sensor failure condition is detected (either short-circuit or open-circuit), the remote temperature sensor failure bit (RTF) in Status Register (bit 0x02) is set ('1') and the OVR pin is forced low when the pin is enabled (RTFIE bit of Configuration Register is equal to 1). This value indicates a remote sensor failure condition. Once this condition occurs, the RTF bit remains '1' and the OVR pin stays low until a power-on reset or software reset is issued, regardless if the failure condition continues thereafter. RTF also generates an RTF interrupt through the SMBALERT pin when RTFIE The SMBALERT pin is a standard interrupt output defined by SMBus specification revision 2.0. This pin is an open-drain output pin and is shown in Figure When an out-of-limit event occurs, the proper flag bits in the status registers are set ('1'), and the corresponding interrupts are generated, if enabled. When an interrupt is generated, the SMBALERT pin asserts low. The host can poll the device status registers to get the information, or give a response to the SMBALERT interrupt signal. It is important to note how the SMBALERT output and status bits behave when writing interrupt-handler software. Figure shows how the SMBALERT output and status bits behave. Once a limit is exceeded, the corresponding status bit is set to '1'. The status bit remains set until the error condition subsides and the status register gets read. The status bits are referred to as being sticky because they remain set until read by software. This design ensures that out-of-limit events cannot be missed if the software is polling the device periodically. The SMBALERT output remains low for the entire duration that the reading is out of limits and remains low until the status register has been read. This architecture has implications on how software handles the interrupt. Figure 23. How Masking the Interrupt Source Affects SMBALERT To prevent the system from being tied up while servicing interrupts, it is recommend to handle the SMBALERT interrupt in this manner: Detect the SMBALERT assertion. Enter the interrupt handler. Read the status registers to identify the interrupt source. Disable the interrupt source by clearing the appropriate enable bit in the configuration registers. Take the appropriate action for a given interrupt source. Exit the interrupt handler. Periodically poll the status registers. If the interrupt source bit has cleared, reset the corresponding interrupt enable bit to This makes the SMBALERT output and status bits behave as shown in Figure Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW LTL (Local□T emperature Local-Low-T emp-Limit)/c163Bit LTH (Local□T emperature Local-High-T emp-Limit)/c179Bit (local□temperature□out-of-range) LTOIE□Bit (local□temperature□interrupt□enabled) (Local□T emperature□Out-of-Range□Interrupt) RTL (Remote□T emperature Remote-Low-T emp-Limit)/c163Bit RTH (Remote□T emperature Remote-High-T emp-Limit)/c179Bit RTOIE□Bit (remote□temperature□interrupt□enabled) (Remote□T emperature□Out-of-Range□Interrupt) LPSV□Bit□(PSV□interrupt) PSVIE□Bit RTF□=□1□(remote□sensor□failure) LTC□Bit□(local□temperature□reaches□critical□temperature) RTC□Bit□(remote□temperature□reaches□critical□temperature) INT -EN R-THERM□Bit□(over□remote□THERM□interrupt) THERMOVIE□Bit L-THERM□Bit□(over□local□THERM□□interrupt) THERMOVIE□Bit RTFIE□Bit (remote□temperature□out-of-range) RPM-ALARM□Bit□(TACH□<□TACH-High-Limit) (RPM□out-of-range) FANIE□Bit (FAN- ACH□interrupt□enabled)T FANS□Bit□(TACH□>□TACH-Low-Limit) (FAN-ORN□interrupt) AMC6821 SMBALERT AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Individual interrupts can be masked by clearing the corresponding interrupt enable bit in the configuration registers to prevent SMBALERT interrupts. Note that masking an interrupt source only prevents the SMBALERT pin output from being asserted; the appropriate status bit gets set as normal. Figure 24. SMBALERT Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW REGISTER MAP AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 All registers are 8-bit. Table shows the memory map. Locations that are marked Reserved read back 0x0000 if they are read by the host. Writing to these locations has no effect. Table Memory Map ADDR NAME R/W DEFAULT BIT BIT BIT BIT BIT BIT BIT BIT IDENTIFICATION REGISTERS 0x3D Device ID Register R 0x21 Device identification number. Always read '0x21'. 0x3E Company ID Register R 0x49 Company identification number. CONFIGURATION REGISTERS FAN-Fault- THERMOVIE FDRC1 FDRC0 PWMINV FANIE INT-EN START EN 0x00 Configuration Register R/W 0xD4 THERM INT FAN-Fault Global Int Fan Control Mode PWM Invert RPM Int EN Start Monitor Enable Pin EN EN TACH- RST PSVIE RTOIE LTOIE RTFIE TACH-EN PWM-EN MODE 0x01 Configuration Register R/W 0x3D Remote PWM-Out Reset LPSV Int EN RT Int EN LT Int EN Failure Int TACH EN TACH Mode EN EN THERM-FAN- EN 0x3F Configuration Register R/W 0x82 THERM-Fan Part Revision Number Control TODIS PSPR TACH-FAST OVREN TACH 0x04 Configuration Register R/W 0x08 Pulse Time-Out Reading OVR Pin EN Reserved Number Fast RPM- LTL LTH RTF R-THERM RTL RTH FANS ALARM 0x02 Status Register R 0x00 RT Over LT Low LT High RT Failure RT Low RT High Fan Slow Fan Fast Therm THERM-IN L-THERM LPSV LTC RTC 0x03 Status Register R 0x00 LT Over LT Below LT Over RT Over Therm Input Reserved Therm Therm Critical Critical TEMPERATURE MONITORING LT2 LT1 LT0 RT2 RT1 RT0 0x06 Temp-DATA-LByte R 0x00 LSBs of Local Reading Reserved LSBs of Remote Reading LT10 (MSB) LT9 LT8 LT7 LT6 LT5 LT4 LT3 0x0A Local-Temp-DATA-HByte R 0x80 The MSBs of newest reading of local temperature sensor. Default 128 RT10 (MSB) RT9 RT8 RT7 RT6 RT5 RT4 RT3 0x0B Remote-Temp-DATA-HByte R 0x80 The MSBs of newest reading of remote temperature sensor. Default 128 LT-H10 LT-H9 LT-H8 LT-H7 LT-H6 LT-H5 LT-H4 LT-H3 0x14 Local-High-Temp-Limit R/W 0x3C MSBs of upper-bound threshold of out-of-range detection of Local-Temp. LSBs are '0'. Default +60 LT-L10 LT-L9 LT-L8 LT-L7 LT-L6 LT-L5 LT-L4 LT-L3 0x15 Local-Low-Temp-Limit R/W 0x00 MSBs of lower-bound threshold of the out-of-range detection of Local-Temp. LSBs are '0'. Default LT-T10 LT-T9 LT-T8 LT-T7 LT-T6 LT-T5 LT-T4 LT-T3 0x16 Local-THERM-Limit R/W 0x46 MSBs of local THERM temperature limit. LSBs are '0'. When local temperature is equal to or above this limit, L-THERM is detected. Default +70 RT-H10 RT-H9 RT-H8 RT-H7 RT-H6 RT-H5 RT-H4 RT-H3 0x18 Remote-High-Temp-Limit R/W 0x50 The MSBs of the upper-bound threshold of the out-of-range detection of Remote-Temp. LSBs are '0'. Default +80 RT-L10 RT-L9 RT-L8 RT-L7 RT-L6 RT-L5 RT-L4 RT-L3 0x19 Remote-Low-Temp-Limit R/W 0x00 The MSBs of the lower-bound threshold of the out-of-range detection of Remote-Temp. LSBs are '0'. Default RT-T10 RT-T9 RT-T8 RT-T7 RT-T6 RT-T5 RT-T4 RT-T3 0x1A Remote-THERM-Limit R/W 0x64 MSBs of Remote THERM temperature limit. LSBs are '0'. When remote temperature is equal to or above this limit, R-THERM is detected. Default +100 LT-C10 LT-C9 LT-C8 LT-C7 LT-C6 LT-C5 LT-C4 LT-C3 0x1B Local-Critical-Temp R/W 0x50 The MSBs of Local Critical temperature shutdown threshold. LSBs are '0'. When the Local-Temp is equal to or above this limit, the LTC interrupt occurs and OVR goes low. Default +80 PSV8 PSV7 PSV6 PSV5 PSV4 PSV3 0x1C PSV-Temp R/W 0x00 Passive Cooling Temperature threshold. LSBs and two MSBs are '0'. When the active control-temperature is equal to or below this threshold in Auto Temp-Fan Control, the PWM duty cycle is and the Fan stops. Default Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 REGISTER MAP (continued) Table Memory Map (continued) ADDR NAME R/W DEFAULT BIT BIT BIT BIT BIT BIT BIT BIT TEMPERATURE MONITORING (continued) RT-C10 RT-C9 RT-C8 RT-C7 RT-C6 RT-C5 RT-C4 RT-C3 0x1D Remote-Critical-Temp R/W 0x69 The MSBs of Remote Critical temperature shutdown threshold. LSBs are '0'. When the Remote-Temp is equal to or above this limit, an RCRT interrupt occurs and OVR goes low. Default +105 PWM CONTROLLER FSPD PWM2 PWM1 PWM0 STIME2 STIME1 STIME0 0x20 FAN-Characteristics R/W 0x1D Spin Dis PWM Frequency Setting Spin-Up Time Setting L-DCY7 L-DCY6 L-DCY5 L-DCY4 L-DCY3 L-DCY2 L-DCY1 L-DCY0 0x21 DCY-Low-Temp R/W 0x55 The duty cycle of PWM when the temperature is equal to or below Low-Temp in Auto Temp-Fan Control mode. Default 0x55, 33.2%. DCY7 (MSB) DCY6 DCY5 DCY4 DCY3 DCY2 DCY1 DCY0 Actual Duty cycle of PWM output. The duty cycle changes immediately after new data is written into this register. 8-bit, 0.39%/bit, range 0%-100%. Default 33%. 0x22 DCY (Duty Cycle) R/W 0x55 In read operation, the returned data is the actual DCY value driving the PWM-Out pin. In write operation, the data written is the actual DCY driving the PWM-Out pin in Software-DCY control mode. In all other control modes, the data is not used to drive the PWM. Instead, it is stored in a temporary register, and is used to control the PWM immediately after the control mode is changed to software-DCY control. RAMPE STEP1 STEP0 RATE2 RATE1 RATE0 THRE1 THRE0 0x23 DCY-RAMP R/W 0x52 Ramp Enable DCY Adjustment Step in DCY Update Rate in Auto Temp-Fan Adjustment Threshold in Auto Fan Control Control Auto Temp-Fan Control L-TEMP4 L-TEMP3 L-TEMP2 L-TEMP1 L-TEMP0 L-SLP2 L-SLP1 L-SLP0 0x24 Local Temp-Fan Control R/W 0x41 Low Temperature in Auto Local Temp-Fan control. Slope in Auto Local Temp-Fan control. R-TEMP4 R-TEMP3 R-TEMP2 R-TEMP1 R-TEMP0 R-SLP2 R-SLP1 R-SLP0 0x25 Remote Temp-Fan Control R/W 0x61 Low Temperature in Auto Remote Temp-Fan control. Slope in Auto Remote Temp-Fan control. TACH (RPM) MEASUREMENT TACH- TACH- TACH- TACH- TACH- TACH- TACH- TACH-DATA7 DATA6 DATA5 DATA4 DATA3 DATA2 DATA1 DATA0 0x08 TACH-DATA-LByte R 0x00 Low byte of TACH measurement. TACH- TACH- TACH- TACH- TACH- TACH- TACH- TACH- DATA15 DATA14 DATA13 DATA12 DATA11 DATA10 DATA9 DATA8 0x09 TACH-DATA-HByte R 0x00 High byte of TACH measurement. TACH-Low- TACH-Low- TACH-Low- TACH-Low- TACH-Low- TACH-Low- TACH-Low- TACH-Low- Limit7 Limit6 Limit5 Limit4 Limit3 Limit2 Limit1 Limit0 0x10 TACH-Low-Limit-LByte R/W 0xFF Low byte of TACH count limit corresponding to minimum allowed RPM. Since the TACH circuit counts between TACH pulses, a slow fan results in a larger measured value. When the measured value is larger than TACH-Low-Limit, the fan runs below the allowed minimum speed limit. TACH-Low- TACH-Low- TACH-Low- TACH-Low- TACH-Low- TACH-Low- TACH-Low- TACH-Low- Limit15 Limit14 Limit13 Limit12 Limit11 Limit10 Limit9 Limit8 0x11 TACH-Low-Limit-HByte R/W 0xFF High byte of TACH Limit corresponding to minimum allowed RPM. TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- Limit7 Limit6 Limit5 Limit4 Limit3 Limit2 Limit1 Limit0 0x12 TACH-High-Limit-LByte R/W 0x00 Low byte of TACH count Limit corresponding to maximum allowed RPM. Since the TACH circuit counts between TACH pulses, a fast fan results in a small measured value. When the measurement is less than this limit, the fan runs above the allowed maximum speed limit. TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- Limit15 Limit14 Limit13 Limit12 Limit11 Limit10 Limit9 Limit8 0x13 TACH-High-Limit-HByte R/W 0x00 High byte of TACH limit corresponding to maximum allowed RPM. TACH- TACH- TACH- TACH- TACH- TACH- TACH- TACH- SETTING7 SETTING6 SETTING5 SETTING4 SETTING3 SETTING2 SETTING1 SETTING0 0x1E TACH-SETTING-LByte R/W 0xFF Low byte of TACH value corresponding to the predetermined target fan speed. TACH-SETTING must be not greater than the value corresponding to the RPM for 30% duty cycle when the TACH-MODE bit is cleared ('0'). TACH- TACH- TACH- TACH- TACH- TACH- TACH- TACH- SETTING15 SETTING14 SETTING13 SETTING12 SETTING11 SETTING10 SETTING9 SETTING8 0x1F TACH-SETTING-HByte R/W 0xFF High byte of TACH value corresponding to the predetermined fan speed. TACH-SETTING must be not greater than the value corresponding to the RPM for 30% duty cycle when the TACH-MODE bit is cleared ('0'). 0x3A Reserved R 0x00 Always read '0'. 0x3B Reserved R 0x00 Always read '0'. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW REGISTER section, all interrupts are the interrupt signal through the SMBALERT pin, unless otherwise noted. Configuration Register (Address 0x00, Value After Power-On Reset 0xD4) BIT NAME R/W DEFAULT enable. When this bit is set, the THERM interrupt is enabled. L-THERM or R-THERM causes an interrupt. When this bit is cleared ('0'), the THERMOVIE R/W THERM interrupt is disabled. When disabled, L-THERM or R-THERM does not assert the SMBALERT pin, but forces the THERM pin low. Power-on default FDRC1 R/W Fan driver control bit Power-on default Refer to Table FDRC0 R/W Fan driver control bit Power-on default Refer to Table Setting this pin to '1' enables the FAN-FAULT pin. Clearing this pin ('0') disables the FAN-Fault-EN R/W FAN-FAULT pin (always in Hi-Z). Power-on default PWM invert bit. When PWMINV (default), the PWM-Out pin goes low for 100% duty cycle (suitable for driving the fan using a PMOS device). Setting PWMINV to '1' makes PWMINV R/W the PWM-Out pin go high (with an external pull-up resistor) for 100% duty cycle (suitable for driving the fan using a NMOS device). Power-on default Fan RPM interrupt enable bit. Power-on default When FANIE the FAN-RPM interrupt is enabled. FANS or RPM-ALARM generates a FANORN interrupt, FANIE R/W making the SMBALERT pin go low. When FANIE a FAN-RPM interrupt is disabled. FANORN does not generate an interrupt. Setting this bit to '1' enables the interrupt from the SMBALERT pin. Clearing this bit ('0') INT-EN R/W disables the interrupt. Power-on default '1' enables monitoring (temperatures and RPM) and PWM outputs. '0' disables START R/W monitoring and PWM output. All registers should be programmed by BIOS before setting this bit to Power-on default Table Fan Driver Control Bits FDRC1 FDRC0 FUNCTION Maximum fast speed calculated by the local temperature-fan control and the remote temperature-fan control. Auto remote-temperature-fan control. The PWM duty cycle is controlled by the remote temperature. Power-on default mode. Software DCY control. Host writes DCY register to set the PWM duty cycle. Software RPM control. Host writes the TACH setting register with the value corresponding to the desired RPM. The device measures the actual RPM and adjusts the PWM duty cycle to maintain the fan speed to the desired value. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Configuration Register (Address 0x01, Value After Power-On Reset 0x3D) BIT NAME R/W DEFAULT bits. RST resets the device. Self-clears after reset. Always read '0'. Power-on RST R/W default LPSV enable bit. Power-on default When LPSVIE the LPSV interrupt is PSVIE R/W enabled and an interrupt is generated when LPSV When LPSVIE LPSV is disabled and LPSV does not cause an interrupt. Remote temperature interrupt enable bit. When RTIE the remote temperature interrupt is enabled and RTO causes an interrupt. When RTIE the remote RTOIE R/W temperature interrupt is disabled and RTO does not generate an interrupt. Power-on default except when a remote sensor failure is detected at power-on. Local temperature interrupt enable bit. Power-on default When LTIE the local LTOIE R/W temperature interrupt is enabled and LTO causes an interrupt. When LTIE the local temperature interrupt is disabled and LTO does not generate an interrupt. Remote sensor failure interrupt enable bit. Power-on default When RTFIE the remote sensor failure interrupt is enabled and RTF causes an interrupt through the RTFIE R/W SMBALERT pin. When RTFIE the remote sensor failure interrupt is disabled and RTF does not generate an interrupt. Setting this bit to '1' enables the TACH input. Clearing ('0') disables the TACH input. TACH-EN R/W Power-on default When the TACH-MODE bit is cleared ('0'), the PWM-Out pin is forced ON during RPM measurement, and internal correction circuitry is enabled to correct the error caused by this extra duty cycle. Making TACH-MODE for the fans that are switched ON/OFF directly by the PWM requires PWM ON to provide TACH pulses. In the software RPM mode, the PWM-Out is forced to 30% duty cycle if the calculated duty cycle is less than 30% when TACH-MODE In all other modes the PWM-Out is forced to if the TACH-MODE R/W calculated duty cycle is less than 7%. When the TACH mode is set ('1'), the internal correction circuit is disabled and PWM-Out is not forced ON Instead, the PWM-Out pin is completely controlled by the value of the DCY register, just as in normal operation. Setting the TACH-MODE bit ('1') when the fans can provide TACH pulses output regardless the status of the PWM-Out pin. The TACH mode must be '1' for any fan which is powered directly by dc power, such as a four-wire fan. Power-on default (See the TACH-DATA Register section for details.) Setting this bit to '1' enables the PWM-Out pin. Clearing ('0') disables the PWM-Out pin PWM-EN R/W (H-Z). Power-on default Configuration Register (Address 0x3F, Value After Power-On Reset 0x82) BIT NAME R/W DEFAULT (as an output) is asserted low. This configuration allows the system to be run in performance mode. Clearing this bit to '0' disables the fan from running at THERM-FAN-EN R/W full-speed whenever the THERM pin (as an output) is asserted low. This configuration allows the system to run in silent mode. Note that this bit has no effect whenever THERM is pulled low as an input. The fan always runs at full speed when the THERM pin is pulled low as an input. Power-on default Reserved R Read-back '0'. Reserved R Read-back '0'. Reserved R Read-back '0'. Part Revision Number R bit (MSB) of 4-bit revision number. Part Revision Number R bit of revision number. Part Revision Number R bit of revision number. Part Revision Number R bit (LSB) of revision number. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Configuration Register (Address 0x04, Value After Power-On Reset 0x08) BIT NAME R/W DEFAULT (default); TODIS SMBus timeout disabled. The AMC6821 includes an SMBus timeout feature. Timeout is enabled (TODIS if a single clock is held low longer than 30ms 10%). When this timeout occurs, the TODIS R/W AMC6821 releases the bus (stops driving the bus and lets SCLK and SDA float high), resets the communication, and is able to receive new START conditions. When TODIS timeout is disabled. In this case, when the clock resumes after being held low for longer than 30ms, the AMC6821 continues the bus communication at the current point. Number of pulses per revolution of the fan. Power-on default PLSPR for two PSPR R/W pulses/revolution (default), PLSPR for four pulses per revolution. When TACH-FAST the TACH data reading is updated every 250ms. This monitor is TACH-FAST R/W the fast RPM monitor. When TACH-FAST the TACH data reading is updated every second. Default power-on default Setting this bit to '1' enables the OVR pin. Clearing this bit ('0') disables the OVR pin OVREN R/W (high-impedance). Default Reserved R Read back '1'. Reading this bit returns not Reserved R Read-back '0'. Reserved R Read-back '0'. Reserved R Read-back '0'. Writing the reserved bit has no effect. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW DEVICE STATUS REGISTERS AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Reading the status registers clears the appropriate status bit. Status register bits are sticky (except the RTF bit). Whenever a status bit is set, indicating an out-of-limit condition, it remains set until the event that caused it is resolved and the status register is read. The status bit can only be cleared by reading the status register after the event is resolved. All bits are cleared when reading the register, and all bits are reasserted if the out-of limit condition still exists on the next monitoring cycle, unless otherwise noted. Status Register (Address 0x02, Value After Power-On or Reset 0x00) BIT NAME R/W DEFAULT R Local-Low-Temp-Limit register. Otherwise, LTL If the local temperature is still outside the local temperature low limit, this bit reasserts on the next monitoring cycle. LTH when the local temperature is greater than or equal to the value of the LTH R Local-High-Temp-Limit register. Otherwise, LTH If the local temperature is still outside the local temperature high limit, this bit reasserts on the next monitoring cycle. Remote sensor-failure interrupt. RTF when the remote temperature sensor fails (short- or open-circuit). RTF when the remote sensor is in normal condition. When RTF the OVR.RTF pin is asserted and the remote temperature data register is set to 0x800 128 C). RTF R RTF also generates an interrupt through the SMBALERT pin if an interrupt is enabled (RTFIE 1). Once RTF is set ('1'), it always remains ('1') until power-on reset or software reset occurs, whether or not the failure condition continues. Reading the status register does not clear the RTF bit. Remote temperature over the remote THERM limit flag. R-THERM when the temperature is greater than the value of the Remote-THERM-Limit register. Otherwise, R-THERM When R-THERM the THERM pin goes low. It also generates a R-THERM R THERM interrupt if THERMOVIE This bit is cleared on a read of Status Register Once cleared, this bit is not reasserted until the remote temperature falls C below this THERM limit, even if the THERM condition persists. Refer to the THERM Pin and External Hardware Control section. RTL when the remote temperature is less than or equal to the value of the RTL R Remote-Low-Temp-Limit register. Otherwise, RTL If the remote temperature is still beyond the remote temperature low limit, this bit reasserts on the next monitoring cycle. RTH when the remote temperature is greater than or equal to the value of RTH R Remote-High-Temp-Limit register. Otherwise, RTH If the remote temperature is still beyond the remote temperature high limit, this bit reasserts on the next monitoring cycle. Fan-slow flag. FANS if the TACH data are greater than or equal to the value of the TACH-Low-Limit register. This bit indicates if the fan becomes stuck or goes under the minimum speed. FANS if the TACH data are smaller than the TACH low limit. This bit is cleared ('0') only after reading this register, and reasserts '1' in the next monitoring if a fan-slow is detected. After spin-up, FANS is set ('1') even if the TACH data are less FANS R than the TACH low limit until the register is read. FANS generates a FAN-ORN interrupt through the SMBALERT pin if FANORN is enabled (FANIE 1). Five consecutive fan-slow returns results in a FAN FAILURE status; which asserts the FAN-FAULT pin low. This interrupt is a non-maskable interrupt (see the FAN-FAULT PIN section for details). Note that a no-FANS (fan-slow) detection is made during spin-up. RPM-ALARM when the TACH data are less than or equal to the value of the TACH-High-Limit register. This means the RPM is over the maximum limit defined by the TACH high limit. Otherwise, RPM-ALARM This bit is cleared when reading this register. Once cleared, this bit is not reasserted on the next monitoring cycle even if the RPM-ALARM R condition still persists. This bit may be reasserted only if the RPM drops below the allowed maximum speed. RPM-ALARM generates a FANORN (fan-out-of-range) interrupt through the SMBALERT pin if FANORN is enabled (FANIE 1), but does not cause an interrupt through the FAN-FAULT pin. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW FAN CONTROLLER REGISTERS AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Status Register (Address 0x03, Value After Power-On or Reset 0x00) BIT NAME R/W DEFAULT input. When this input is pulled low, THERM-IN and THERM-IN R the fan is driven at full speed. This bit is cleared when reading this register. Local temperature over the local THERM limit flag. L-THERM when the local temperature is greater than the value of the Local-THERM-Limit register. Otherwise, L-THERM When L-THERM the THERM pin goes low. It also generates a L-THERM R THERM interrupt through the SMBALERT pin, if enabled (THERMOVIE 1). This bit is cleared on a read of Status Register Once cleared, this bit is not reasserted until the temperature falls C below the THERM limit, even if the THERM condition persists. Refer to the THERM Pin and External Hardware Control section. Active control temperature below the PSV (passive cooling) temperature flag. This bit is set to '1' when the active control temperature is equal to or below the PSV temperature. Otherwise, this bit is cleared ('0'). LPSV generates a PSV interrupt on the LPSV R SMBALERT pin, if enabled (PSVIE 1). This bit is cleared when reading this register. If the active control temperature remains equal to or below the PSV temperature, this bit reasserts on the next monitoring cycle. Local temperature over the local critical temperature flag. This bit is set ('1') when the local temperature is equal to or above the local critical temperature. LTC if the local critical temperature is below this value. LTC asserts the OVR pin low and generates LTC R an LTC interrupt (non-maskable) though the SMBALERT pin. This bit is cleared when reading this register. If the over-critical limit condition persists, this bit reasserts on the next monitoring cycle. Remote temperature over the remote critical temperature flag. This bit is set to '1' when the remote temperature is equal to or above the remote critical temperature. RTC if the remote critical temperature is below this value. RTC asserts the OVR pin low RTC R and generates an RTC interrupt (non-maskable) though the SMBALERT pin. This bit is cleared when reading this register. If the over-critical limit condition persists, this bit reasserts on next monitoring cycle. Reserved R Reserved. Reading returns '0'. Reserved R Reserved. Reading returns '0'. Reserved R Reserved. Reading returns '0'. DCY (Duty Cycle) Register (Address 0x22, Value After Power-On or Reset 0x55) BIT NAME DEFAULT (MSB) DCY7 (MSB) DCY CODE DUTY CYCLE DCY6 0x00 DCY5 0x01 0.392% DCY4 ... ... ... ... DCY3 0x40 25% DCY2 ... ... ... ... DCY1 0x80 50% DCY0 ... ... ... ... 0xFF 100% The DCY register stores the value of the PWM duty cycle, 0x00 corresponds to 0%, and 0xFF to 100%. 1LSB corresponds to 0.392%. Power-on default 0x55, 33.2%. In reading operation, the returned data are the actual duty cycle (DCY) value driving the PWM-Out pin. In writing operation, the data written is the actual DCY driving the PWM-Out pin in the software DCY control mode. However, in all other control modes, the data being written are not used to drive the PWM. Instead, it is stored in a temporary register, and controls the PWM immediately after the control mode is changed to the software DCY control mode. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Fan Characteristics Register (Address 0x20, Value After Power-On or Reset 0x1D) BIT NAME DEFAULT disabled. When FSPD the fan spin-up process is enabled. Reserved PWM2 PWM Frequency Bits PWM1 PWM2 PWM1 PWM0 PWM Frequency PWM0 When PWM-MODE pin is floating or tied to V DD 10Hz 15Hz 23Hz 30Hz (Default) 38Hz 47Hz 62Hz 94Hz When PWM-MODE pin is tied to GND 1kHz 10kHz 20kHz 25kHz (Default) 30kHz 40kHz 40kHz 40kHz STIME2 Spin-Up Time Bit Spin-Up Time STIME1 STIME2 STIME1 STIME0 (in Seconds) STIME0 0.2 0.4 0.6 0.8 (Default) This register specifies the PWM frequency and the fan spin-up functions. Fan Spin Disable Bit: FSPD This bit enables or disables the spin-up function. PWM Frequency Bits: [PWM2:PWM0] These bits specify the PWM frequency; the high range (1kHz 40kHz) has a default value of 25kHz, and the low range (10Hz 94Hz) has a default value of 30Hz. The clock frequency is 12.8MHz. The PWM-MODE pin determines which range is selected. When the PWM mode is tied to ground, the high range is selected; otherwise, the low range is selected. Spin-Up Time Bits: [STIME2:STIME0] These bits specify a predetermined time period, or spin-up time, during which the 100% duty cycle is applied to start the fan spinning. These bits are ignored when FSPD Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 DCY-LOW-TEMP Register (Address 0x21, Value After Power-On or Reset 0x55, 33.2%) Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) L-DCY L-DCY L-DCY L-DCY L-DCY L-DCY L-DCY L-DCY This register specifies the duty cycle in Auto Temp-Fan Control mode when the control temperature is less than or equal to the value of the Low Temperature bits in the TEMP-FAN Control Regsiter. Local TEMP-FAN Control Register (Address 0x24, Value After Power-On or Reset 0x41) DEFAUL BIT NAME T C L-TEMP1 C L-TEMP0 C C ... ... ... ... ... ... C (Default) ... ... ... ... ... ... 120 C 124 C L-SLP2 Slope Bits of Local Sensor L-SLP1 Slope Temp Range in C L-SLP0 L-SLP2 L-SLP1 L-SLP0 LSB/ C C (DCY 33.3% to 100%) 12.55 10.63 (Default) 6.27 21.25 3.14 42.5 1.57 0.78 This register specifies the parameters of the local Temperature-Fan Control mode. Low Temperature Bits: [L-TEMP4:L-TEMP0] These bits specify the low temperature of the auto local temperature fan control. In this control mode, the duty cycle is equal to the value of the DCY-LOW-TEMP register when the local temperature is less than or equal to the value defined by bits [L-TEMP4:L-TEMP0]. Slope Bits: [L-SLP2:L-SLP0] These bits define the increment of the duty cycle when the local temperature rises every C in the auto local temperature fan control. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Remote TEMP-FAN Control Register (Address 0x25, Value After Power-On or Reset 0x61) DEFAUL BIT NAME T C R-TEMP1 C R-TEMP0 C C ... ... ... ... ... ... C (Default) ... ... ... ... ... ... 120 C 124 C R-SLP2 Slope Bits of Remote Sensor R-SLP1 Slope Temp Range in C R-SLP0 R-SLP2 R-SLP1 R-SLP0 LSB/ C C (DCY 33.3% to 100%) 12.55 10.63 (Default) 6.27 21.25 3.14 42.5 1.57 0.78 This register specifies the parameters of the Remote Temperature-Fan Control mode. Low Temperature Bits: [R-TEMP 4:R-TEMP0] These bits specify the low temperature of the auto remote temperature fan control. In this control mode, the duty cycle is equal to the value of the DCY-LOW-TEMP register when the remote temperature is less than or equal to the value defined by bits [R-TEMP4:R-TEMP0]. Slope Bits: [R-SLP2:R-SLP0] These bits define the increment of the duty cycle when the remote temperature rises every C in the auto remote temperature fan control. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 DCY-RAMP Register (Address 0x23, Value After Power-On or Reset 0x52) BIT NAME DEFAULT Bit. Ignored in software-RPM control. When RAMPE Ramp is enabled. The DCY changes to the desired value gradually according to STEP bits and RATE bits. When RAMPE Ramp is disabled. DCY changes to the desired target value immediately. Default STEP1 Adjustment Step Bits. STEP0 STEP1 STEP0 Max Adjustment (Default) RATE2 DCY Updating Rate Bits in Auto Temp-Fan Control Mode. RATE1 DCY Updates/Sec RATE2 RATE1 RATE0 (Auto Temp-Fan CTR) RATE0 0.0625 0.125 0.25 0.5 (Default) THRE1 Adjustment Threshold Bits in Auto Temp-Fan Control Mode. THRE0 THRE1 THRE0 Threshold (Default) This register is ignored in the software DCY control mode. This register determines how fast the PWM duty cycle is adjusted to the desired value when the temperature changes in the automatic temperature-fan control, or when the fan speed varies from the predetermined value in the software RPM control mode. RAMPE: Ramp Enable bit. This bit is ignored in the software RPM control mode. Adjustment Step Bits: [STEP1:STEP0] In the software RPM control, these bits specify the amount that duty cycle changes each time. In the auto fan temperature control mode, these bits are ignored when RAMPE When RAMPE these bits define the maximum amount that the duty cycle can change each time if the duty cycle needs to be adjusted. For example, if the current value of the duty cycle is 50% and the desired value is 75%, the total required increment is 25%. If the step is (bits [STEP1:STEP0] '00'), then the duty cycle increases by (0.39%) each time the duty cycle is updated, and the duty cycle reaches the desired value (75%) after updates. This takes eight seconds if the update rate is 8/sec (bits [RATE2:RATE0] '111'), and takes seconds if the update rate is 1/sec. (bits [RATE2:RATE0] '100'). However, if the step is 2/256, then the time reduces to half. If the required adjustment is less than the value specified by step bits, the actual required value is used. For example, if the current duty cycle is 50%, the required value is 73%, and the step is 4/256, a total of updates are needed. The duty cycle increases 21.875% after the first updates, and increases 1.125% in the last update. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW TEMPERATURE DATA REGISTERS AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Updating Rate Bits: [RATE2:RATE0] These bits define the rate (time/sec) that the duty cycle is recalculated in the auto temp-fan control mode. The value of [RATE2:RATE0] does not affect the ADC conversion rate. Both external and local temperature readings are updated continuously, even if the DCY is updated slowly. The RPM monitoring rate and DCY updating rate in the software RPM control mode are specified by the TACH-FAST bit of Configuration Register The [RATE2:RATE0] bits are ignored in this mode. Adjustment Threshold Bits: [THRE1:THRE0] These bits determine the threshold of the duty cycle adjustment in the auto temp-fan control mode, and are ignored in all other modes. When the auto fan temperature control loop is active, the duty cycle is not adjusted if the required adjustment is less than or equal to the threshold defined by bits [THRE1:THRE0]. This provides a hysteresis to improve the control stability. For example, if the current duty cycle is 50% and the desired value is 71%, the total required increment is 21%. If the step is and the threshold is (0.78%), the duty cycle reaches 70.31% after updates, 0.6875% less than the desired value. This difference is less than the threshold (0.78%); therefore, the adjustment stops. However, if the threshold is (0.39%), then one more update occurs, and the duty cycle increases by 0.39% (1LSB) because 0.39% (1LSB) 0.6875% 0.78% (2LSB). Finally, the duty cycle reaches 70.7%, 0.3% less than the desired value because of the limitation of 8-bit resolution. Note that bits [THRE1:THRE0] are ignored in the software RPM control. In this mode, the DCY adjustment stops when the difference between the TACH data and TACH setting is less than or equal to 0x000A. Local Temperature Data Register Bits: [LT10:LT0] Bits [LT10:LT0] are the newest local temperature reading. Remote Temperature Register Bits: [RT10:RT0] Bits [RT10:RT0] are the newest remote temperature reading. Temp-DATA-LByte Register (Address 0x06, Value After Power-On or Reset 0x00) Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) LT2 LT1 LT0 (LSB) RT2 RT1 RT0 Bits [LT2:LT0] are the three LSBs of the newest local temperature reading. Bits [RT2:RT0] are the three LSBs of the newest remote temperature reading. Local-Temp-DATA-HByte Register (Address 0x0A, Value After Power-On or Reset 0x80, 128 Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) LT10 (MSB) LT9 LT8 LT7 LT6 LT5 LT4 LT3 Bits [LT10:LT3] are the eight MSBs of the newest local temperature reading. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW TEMPERATURE LIMIT REGISTERS AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Remote-Temp-DATA-HByte Register (Address 0x0B, Value After Power-On or Reset 0x80, 128 Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) RT10 (MSB) RT9 RT8 RT7 RT6 RT5 RT4 RT3 Bits [RT10:RT3] are the eight MSBs of the newest remote temperature reading. It is important to note that temperature can be read as an 8-bit value (with C resolution) from the Temp-DATA-Hbyte register, or as an 11-bit value (with 0.125 C resolution) from the Temp-DATA-LByte and Temp-DATA-HByte registers. If only C resolution is required, the temperature readings can be read back at any time and in no particular order. If the 11-bit measurement is required, this involves a two-register read for each measurement. The Temp-DATA-LByte register (0x06) should be read first. This condition causes all temperature reading registers to be frozen until the Remote-Temp-DATA-HByte Register (0x0B) is read. This architecture also prevents an MSB reading from being updated while the 3LSBs are being read, and vice versa. Local High Temperature Limit Register: [LT-H10:LT-H0] Local Low Temperature Limit Register: [LT-L10:LT-L0] Local-High-Temp-Limit Register (Address 0x14, Value After Power-On or Reset 0x3C, +60 Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) LT-H10 (MSB) LT-H9 LT-H8 LT-H7 LT-H6 LT-H5 LT-H4 LT-H3 These bits are the upper bounds of the local temperature. Bits [LT-H2:LT-H0] are always '0'. Local-Low-Temp-Limit Register (Address 0x15, Value After Power-On or Reset 0x00, Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) LT-L10 (MSB) LT-L9 LT-L8 LT-L7 LT-L6 LT-L5 LT-L4 LT-L3 These bits are the lower bounds of the local temperature. Bits [LT-L2:LT-L0] are always '0'. Local-THERM-Limit Register (Address 0x16, Value After Power-On or Reset 0x46, +70 Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) LT-T10 (MSB) LT-T9 LT-T8 LT-T7 LT-T6 LT-T5 LT-T4 LT-T3 These bits are the thermal threshold of the local temperature. Bits [LT-T2:LT-T0] are always '0'. Remote-High-Temp-Limit Register (Address 0x18, Value After Power-On or Reset 0x50, +80 Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) RT-H10 (MSB) RT-H9 RT-H8 RT-H7 RT-H6 RT-H5 RT-H4 RT-H3 These bits are the upper bounds of the remote temperature. Bits [RT-H2:RT-H0] are always '0'. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 Remote-Low-Temp-Limit Register (Address 0x19, Value After Power-On or Reset 0x00, Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) RT-L10 (MSB) RT-L9 RT-L8 RT-L7 RT-L6 RT-L5 RT-L4 RT-L3 These bits are the lower bounds of the remote temperature. Bits [RT-L2:RT-L0] are always '0'. Remote-THERM-Limit Register (Address 0x1A, Value After Power-On or Reset 0x64, +100 Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) RT-T10 (MSB) RT-T9 RT-T8 RT-T7 RT-T6 RT-T5 RT-T4 RT-T3 These bits are the thermal threshold of the remote temperature. Bits [RT-T2:RT-T0] are always '0'. Local-Critical-Temp Register (Address 0x1B, Value After Power-On or Reset 0x50, +80 Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) LT-C10 LT-C9 LT-C8 LT-C7 LT-C6 LT-C5 LT-C4 LT-C3 These bits are the critical threshold of the local temperature. Bits [LT-C2:LT-C0] are always '0'. PSV-Temp Register (Address 0x1C, Value After Power-On or Reset 0x00, Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) PSV8 PSV7 PSV6 PSV5 PSV4 PSV3 Bits [PSV10:PSV0] are the passive cooling temperature threshold. Bits PSV10, PSV9, and [PSV2:PSV0] are always '0'. The PSV ranges from C to +64 In the auto fan temperature loop, the fan stops and the duty cycle is forced to when the active temperature is equal to or below the PSV temperature. Remote-Critical-Temp Register (Address 0x1D, Value After Power-On or Reset 0x69, +105 Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) RT-C10 RT-C9 RT-C8 RT-C7 RT-C6 RT-C5 RT-C4 RT-C3 Bits [RT-C10:RT-C0] are the critical threshold of the remote temperature. [Bits RT-C2:RT-C0] are always '0'. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 TACH-DATA Register TACH-DATA-LByte Register (Address 0x08, Power-On Default 0x00) Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) TACH-DATA7 TACH-DATA6 TACH-DATA5 TACH-DATA4 TACH-DATA3 TACH-DATA2 TACH-DATA1 TACH-DATA0 TACH-DATA-HByte Register (Address 0x09, Power-On Default 0x00) Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) TACH-DATA15 TACH-DATA14 TACH-DATA13 TACH-DATA12 TACH-DATA11 TACH-DATA10 TACH-DATA9 TACH-DATA8 Bits [TACH-DATA15:TACH-DATA0] are the number of clock pulses counted during one fan revolution and represents the period of the fan revolution (refer to the Fan Speed Measurement section). Reading the TACH data register involves a two-register read. The low byte should be read first. This method causes the high byte to be frozen until both the high and low byte registers have been read from, preventing erroneous TACH readings. TACH Setting Register TACH-SETTING-LByte Register (Address 0x1E, Power-On Default 0xFF) Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) TACH-SETTING7 TACH-SETTING6 TACH-SETTING5 TACH-SETTING4 TACH-SETTING3 TACH-SETTING2 TACH-SETTING1 TACH-SETTING0 TACH-SETTING-HByte Register (Address 0x1F, Power-On Default 0xFF) Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) TACH- TACH- TACH- TACH- TACH- TACH- TACH- TACH- SETTING15 SETTING14 SETTING13 SETTING12 SETTING11 SETTING10 SETTING9 SETTING8 Bits [TACH-SETTING15:TACH-SETTING0] represent the period of the target fan RPM (in the number of clock pulses counted during one fan revolution). Refer to the Fan Speed Measurement section. Software writes this register to set the target RPM in the Software-RPM Control mode. When the TACH-MODE bit (bit 0x02) is cleared ('0'), the TACH setting must be not greater than the value corresponding to the RPM for a 30% duty cycle. When the TACH mode is equal to '1', the TACH setting must be not greater than the value corresponding to the allowed minimum RPM at which the fan properly runs. Submit Documentation Feedback
www.ti.com PRODUCT PREVIEW AMC6821 SBAS386A MAY 2006 REVISED MAY 2006 TACH Low Limit Register TACH-Low-Limit-LByte Register (Address 0x10, Power-On Default 0xFF) Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) TACH-Low-Limit7 TACH-Low-Limit6 TACH-Low-Limit5 TACH-Low-Limit4 TACH-Low-Limit3 TACH-Low-Limit2 TACH-Low-Limit1 TACH-Low-Limit0 TACH-Low-Limit-HByte Register (Address 0x11, Power-On Default 0xFF) Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) TACH-Low- TACH-Low- TACH-Low- TACH-Low- TACH-Low- TACH-Low- TACH-Low- TACH-Low- Limit15 Limit14 Limit13 Limit12 Limit11 Limit10 Limit9 Limit8 Bits [TACH-Low-Limit15:TACH-Low-Limit0] are the value that corresponds to the predetermined minimum allowable fan speed (RPM). If the value of the TACH data register is greater than this bound, the fan speed is below the minimum allowed RPM. TACH High Limit Register TACH-High-Limit-LByte Register (Address 0x12, Power-On Default 0x00) Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- Limit7 Limit6 Limit5 Limit4 Limit3 Limit2 Limit1 Limit0 TACH-High-Limit-HByte Register (Address 0x13, Power-On Default 0x00) Bit (MSB) Bit Bit Bit Bit Bit Bit Bit (LSB) TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- TACH-High- Limit15 Limit14 Limit13 Limit12 Limit11 Limit10 Limit9 Limit8 Bits [TACH-High-Limit15:TACH-High-Limit0] are the value that corresponds to the predetermined maximum allowable fan speed (RPM). If the value of the TACH data register is smaller than this bound, the fan speed is above the maximum allowed RPM. Submit Documentation Feedback
Orderable Device Status(1) Package Type Package Drawing Pins Package Qty Eco Plan(2) Lead/Ball FinishMSL Peak Temp (3) AMC6821SDBQ PREVIEW SSOP/ QSOP DBQ 16 100 TBD Call TI Call TI AMC6821SDBQR PREVIEW SSOP/ QSOP DBQ 16 2500 TBD Call TI Call TI (1)The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2)Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontentfor the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS):TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt):This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br):TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. PACKAGE OPTION ADDENDUM www.ti.com 12-May-2006 Addendum-Page 1
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Amplifiers amplifier.ti.com Audio www.ti.com/audio Data Converters dataconverter.ti.com Automotive www.ti.com/automotive DSP dsp.ti.com Broadband www.ti.com/broadband Interface interface.ti.com Digital Control www.ti.com/digitalcontrol Logic logic.ti.com Military www.ti.com/military Power Mgmt power.ti.com Optical Networking www.ti.com/opticalnetwork Microcontrollers microcontroller.ti.com Security www.ti.com/security Telephony www.ti.com/telephony Video & Imaging www.ti.com/video Wireless www.ti.com/wireless Mailing Address: Texas Instruments Post Office Box 655303 Dallas, Texas 75265 Copyright 2006, Texas Instruments Incorporated