AF0100 LITTELFUSE
Document overview
- PDF pages: 1
Technical content
Page 1
Protection Relays and Controls
Arc-Flash Monitoring
AF0100 SERIES
Arc-Flash Relay

Simplified Circuit Diagram
Digital I/O Connection to other AF0100 or AF0500
Description
The AF0100 Series arc-flash relay is a cost-effective solution that reduces arc-fault damage by detecting the light from an arc flash and rapidly tripping. Two remote light sensors can be connected to one relay and multiple AF0100 and/or AF0500 relays can be connected to monitor additional sensors, providing complete coverage for a wide range of applications. The compact, DIN-rail or surface-mountable body makes this an ideal solution for equipment manufacturers. Two isolated Form-C contacts are provided for applications with multiple devices that must be tripped. This is especially useful for generator applications where the generator and breaker need to be tripped in case of an arc flash.
The AF0100 accepts PGA-LS10 point sensors and PGA-LS20/ PGA-LS30 fiber-optic sensors in any combination. Sensor health is continuously monitored to ensure fail-safe operation. A solid-state redundant trip circuit provides an internal fail-safe mechanism and fast arc-flash response during power up. Front-panel and sensor LEDs indicate sensor health and

fault location.
Features & Benefits
FEATURES
BENEFITS Fits into a wide range of arc-flash applications
Compact
Point sensors or fiber-optic sensors can be used in
Two optical
any combination for coverage flexibility
sensor types
One relay can monitor two arc-flash sensors
Dual sensor inputs
Allows for operation in bright environments and
Adjustable light
maximum sensitivity in dark environments
sensitivity
Multiple AF0100 or AF0500 units can be
Discrete wire
interconnected to form a system
networking
Continuous monitoring of optical sensors and
Fail-safe system
Ordering Information
inputs ensures protection

Specifications
Input Voltage AF0100-00
100-240 VAC/VDC, 24-48 VDC
AF0100-10
24-48 VDC
Dimensions
H 90 mm (3.5”); W 128 mm (5.0”); D 60 mm (2.4”)
Trip, Error Relays
Form C, 250 VAC/30 VDC, 6 A resistive
Trip Time
5 ms (typical)
Sensitivity
10-25 klux programmable
Mounting
Surface, DIN rail
Operating Temperature
-40°C to +70°C (-40°F to 158°F)
Shipping Weight
1.0 kg (2.2 lb)
Certifications
UL Listed (UL 508), CE, RCM, FCC
Warranty
5 years
©2018 Littelfuse Protection Relays & Controls www.littelfuse.com/af0100
Configuration software is easy to use with no
USB interface
drivers or software installation Ensures continuous protection with self diagnostic
Unit health
and remote unit-healthy indication Trip and sensor status indication both on relay
LED Indication
and sensors
Accessories
PGA-LS10 Point Sensor
A
Line-of-sight light sensor detects an arc as small as 3 kA within a 2-m half-sphere. Includes sensor health and trip indication.
B
PGA-LS20/PGA-LS30 Fiber-Optic Sensor 360° light sensor to run along bus bars. Includes sensor health and trip indication.
Rev: 1-B-013118
Based on Manual Rev 0-B-013118