Autocalibrating, 4-Channel, 12-Bit ANALOG-TO-DIGITAL CONVERTER
FEATURES
l TOTAL UNADJUSTED ERROR ≤ 1/2LSB OVER FULL TEMPERATURE RANGE l FOUR-CHANNEL INPUT MULTIPLEXER l LOW POWER: 10mW plus Power Down Mode l SINGLE SUPPLY: +5V l FAST CONVERSION TIME: 8.5 µs Including Acquisition l AUTOCAL: No Offset or Gain Adjust Required l UNIPOLAR INPUTS: 0V to 5V l MICROPROCESSOR-COMPATIBLE INTERFACE l INTERNAL SAMPLE/HOLD
DESCRIPTION
The ADC7802 is a monolithic CMOS 12-bit A/D converter with internal sample/hold and four-channel multiplexer. An autocalibration cycle, occurring auto- matically at power on, guarantees a total unadjusted error within ±1/2LSB over the specified temperature range, eliminating the need for offset or gain adjust- ment. The 5V single-supply requirements and stan- dard CS, RD, and WR control signals make the part very easy to use in microprocessor applications. Con- version results are available in two bytes through an 8- bit three-state output bus. The ADC7802 is available in a 28-pin plastic DIP and 28-lead PLCC, fully specified for operation over the industrial –40°C to +85°C temperature range. Clock Control Logic Calibration Microcontroller and Memory Address Latch and Decoder Analog Multiplexer Capacitor Array Sampling ADC Three-State Input/Output BUSY 8-Bit Data Bus VREF AIN0 AIN1 AIN2 AIN3 CS RD WR SFR VREF+– International Airport Industrial Park • Mailing Address: PO Box 11400 • Tucson, AZ 85734 • Street Address: 6730 S. Tucson Blvd. • Tucson, AZ 85706 Tel: (520) 746-1111 • Twx: 910-952-1111 • Cable: BBRCORP • Telex: 066-6491 • FAX: (520) 889-1510 • Immediate Product Info: (800) 548-6132 © 1990 Burr-Brown Corporation PDS-1050B Printed in U.S.A. June, 1993
At VA = VD = VREF + = 5V ±5%; VA ≥ VD ≥ VREF +; VREF – = AGND = DGND = 0V; CLK = 2MHz external with 50% duty cycle, TA = –40°C to +85°C, after calibration cycle at any temperature, unless otherwise specified. PARAMETER CONDITIONS MIN TYP MAX UNITS RESOLUTION 12 Bits ANALOG INPUT Voltage Input Range V REF + = 5V, VREF – = 0V 0 5 V Input Capacitance 50 pF On State Bias Current 100 nA Off State Bias Current T A = 25°C1 0 n A TA = –40°C to +85°C 100 nA On Resistance Multiplexer 2k Ω Off Resistance Multiplexer 10 M Ω Channel Separation 500Hz 92 dB REFERENCE INPUT For Specified Performance: VREF +V REF + ≤ VA 5V VREF – 0V For Derated Performance: (1) VREF + 4.5 V A V VREF –0 1 V Input Reference Current V REF + = 5V, VREF – = 0V 10 100 µA THROUGHPUT TIMING Conversion Time With External Clock (Including CLK = 2MHz, 50% Duty Cycle 8.5 µs Multiplexer Settling Time and Acquisition Time) CLK = 1MHz, 50% Duty Cycle 17 µs CLK = 500kHz, 50% Duty Cycle 34 µs With Internal Clock Using T A = +25°C1 0 µs Recommended Clock Components T A = –40°C to +85°C1 0 µs Analog Signal Bandwidth (2) 500 Hz Slew Rate (2) 8 mV/ µs Multiplexer Settling Time to 0.01% 460 ns Multiplexer Access Time 20 ns ACCURACY Total Adjusted Error,(3) All Channels ±1/2 LSB Differential Nonlinearity ±1/2 LSB No Missing Codes Guaranteed Gain Error All Channels ±1/4 LSB Gain Error Drift Between Calibration Cycles ±0.2 ppm/ °C Offset Error All Channels ±1/4 LSB Offset Error Drift Between Calibration Cycles ±0.2 ppm/ °C Channel-to-Channel Mismatch ±1/4 LSB Power Supply Sensitivity V A = V D = 4.75V to 5.25V ±1/8 LSB DIGITAL INPUTS All Pins Other Than CLK: VIL 0.8 V VIH 2.4 V Input Current T A = +25°C, VIN = 0 to VD 1 µA TA = –40°C to +85°C, VIN = 0 to VD 10 µA CLK Input: VIL 0.8 V VIH 3.5 V IIL 10 µA IIH 1.5 mA IIH Power Down Mode (D3 in SFR HIGH) 100 nA DIGITAL OUTPUTS VOL ISINK = 1.6mA 0.4 V VOH ISOURCE = 200µA4 V Leakage Current High-Z State, V OUT = 0V to VD ±1 µA Output Capacitance High-Z State 4 15 pF POWER SUPPLIES Supply Voltage for Specified Performance: VA 4.75 5 5.25 V VD VA ≥ VD 4.75 5 5.25 V Supply Current: IA 1 2.5 mA ID Logic Input Pins HIGH or LOW 1 2 mA Power Dissipation WR = RD = CS = BUSY = HIGH 10 mW Power Down Mode See Table III, Page 9 50 µW TEMPERATURE RANGE Specification –40 +85 °C Storage –65 +150 °C NOTES: (1) For (VREF +) – (VREF –) as low as 4.5V, the total error will typically not exceed ±1LSB. (2) Faster signals can be accurately converted by using an external sample/hold in front of the ADC7802. (3) After calibration cycle, without external adjustment. Includes gain (full scale) error, offset error, integral nonlinearity, differential nonlinearity, and drift. ADC7802BP, ADC7802BN
The information provided herein is believed to be reliable; however, BURR-BROWN assumes no responsibility for inaccuracies or omissions. BURR-BROWN assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. BURR-BROWN does not authorize or warrant any BURR-BROWN product for use in life support devices and/or systems. ABSOLUTE MAXIMUM RATINGS
PACKAGE INFORMATION
MODEL PACKAGE NUMBER (1) ADC7802BN 28-Pin PLCC 251 ADC7802BP 28-Pin Plastic DIP 215 NOTE: (1) For detailed drawing and dimension table, please see end of data sheet, or Appendix D of Burr-Brown IC Data Book.
ORDERING INFORMATION
MODEL ERROR, LSB RANGE, °C PACKAGE ADC7802BN ±1/2 –40 to +85 PLCC ADC7802BP ±1/2 –40 to +85 Plastic DIP
PIN # NAME DESCRIPTION 1 SFR Special Function Register. When connected to a microprocessor address pin, allows access to special functions through D0 to D7. See the sections discussing the Special Function Register. If not used, connect to DGND. This pin has an internal pull-down. 2 to 5 AIN0 to AIN3 Analog inputs. Channel 0 to channel 3. 6V REF + Positive voltage reference input. Normally +5V. Must be ≤ VA. 7V REF – Negative voltage reference input. Normally 0V. 8 DGND Digital ground. DGND = 0V. D Logic supply voltage. VD = +5V. Must be ≤ VA and applied after VA. 10 to 17 D0 to D7 Data Bus Input/Output Pins. Normally used to read output data. See section on SFR (Special Function Register) for other uses. When SFR is LOW, these function as follows: 10 D7 Data Bit 7 if HBE is LOW; if HBE is HIGH, acts as converter status pin and is HIGH during conversion or calibration, goes LOW after the conversion is completed. (Acts as an inverted BUSY.) 11 D6 Data Bit 6 if HBE is LOW; LOW if HBE is HIGH. 12 D5 Data Bit 5 if HBE is LOW; LOW if HBE is HIGH. 13 D4 Data Bit 4 if HBE is LOW; LOW if HBE is HIGH. 14 D3 Data Bit 3 if HBE is LOW; Data Bit 11 (MSB) if HBE is HIGH. 15 D2 Data Bit 2 if HBE is LOW; Data Bit 10 if HBE is HIGH. 16 D1 Data Bit 1 if HBE is LOW; Data Bit 9 if HBE is HIGH. 17 D0 Data Bit 0 (LSB) if HBE is LOW; Data Bit 8 if HBE is HIGH. 18 RD Read Input. Active LOW; used to read the data outputs in combination with CS and HBE. 19 CS Chip Select Input. Active LOW. 20 WR Write Input. Active LOW; used to start a new conversion and to select an analog channel via address inputs A0 and A1 in combination with CS. The minimum WR pulse LOW width is 100ns. 21 HBE High Byte Enable. Used to select high or low data output byte in combination with CS and RD, or to select SFR. 22 BUSY BUSY is LOW during conversion or calibration. BUSY goes HIGH after the conversion is completed. 23 CLK Clock Input. For internal/external clock operation. For external clock operation, connect pin 23 to a 74 HC-compatible clock source. For internal clock operation, connect pin 23 per the clock operation description. 24 to 25 A0 to A1 Address Inputs. Used to select one of four analog input channels in combination with CS and WR. The address inputs are latched on the rising edge of WR or CS. A1 A0 Selected Channel LOW LOW AIN0 LOW HIGH AIN1 HIGH LOW AIN2 HIGH HIGH AIN3 26 CAL Calibration Input. A calibration cycle is initiated when CAL is LOW. The minimum pulse width of CAL is 100ns. If not used, connect to V D. In this case calibration is only initiated at power on, or with SFR. This pin has an internal pull-up. 27 AGND Analog Ground. AGND = 0V. 28 V A Analog Supply. VA = +5V. Must be ≥ VD and VREF +. AIN2 AIN1 AIN0 SFR V AGND CAL A CLK BUSY HBE WR CS AIN3 DGND V D RD REF V REF V SFR AIN0 AIN1 AIN2 AIN3 V + V – DGND V V AGND CAL CLK BUSY HBE WR CS RD REF REF D A
TYPICAL PERFORMANCE CURVES At VA = VD = VREF + = 5V, VREF – = AGND = 0V, TA = +25°C, unless otherwise specified. CHANNEL SEPARATION vs FREQUENCY 100 Channel Separation (dB) 1 10 100 1000 Frequency of 5Vp-p Signal on Channel AIN2 (kHz) Channel AIN3 Channel AIN1 Channel AIN0 Conversions Yielding Expected Code (%) Analog Input Voltage – Expected Code Center (LSBs) CODE TRANSITION NOISE 100 0.25 0.5 0.75 1 SIGNAL/(NOISE + DISTORTION) vs INPUT FREQUENCY 0.1 0.2 0.4 1 10 42 Input Frequency (kHz) 0.6 6 Signal/(Noise + Distortion) (dB) POWER SUPPLY REJECTION vs FREQUENCY Full-Scale Error vs Change in Supply Voltage (mV/V) 0.6 0.4 0.2 0.1 Frequency (kHz) 0.1 1 10 100 1000 VA VD INTERNAL CLOCK FREQUENCY vs TEMPERATURE Clock Frequency (MHz) Ambient Temperature (°C) 1.15 1.1 1.05 0.95 0.9 –50 –25 0 25 50 75 100 R CLOCK = 70kΩ INTERNAL CLOCK FREQUENCY vs RCLOCK 0.1 Clock Frequency (MHz) 10 100 1k R CLOCK (kΩ )
VIL, VOH or VOL . (2) The internal RD pulse is performed by a NOR wiring of CS and RD. The internal WR pulse is performed by a NOR wiring of CS and WR. (3) Figures 7 and 8 show the measurement circuits and pulse diagrams for testing transitions to and from Hi-Z states. TABLE I. Timing Specifications (CLK = 1MHz external, TA = –40°C to +85°C). register are latched into the output register as they are made. started, for faster system throughput. +85oC operating range for ease of system design. Register is made by driving SFR HIGH. FIGURE 5. Writing to the SFR. FIGURE 6. Reading the SFR.
calibration, which may happen in very noisy systems. It is reset by starting a calibration, and remains low after a calibration without an overflow is completed. Writing a HIGH to D3 in the FSR puts the ADC7802 in the Power Down Mode. Power consumption is reduced to 50µW and D3 remains HIGH. To exit Power Down Mode, either write a LOW to D3 in the SFR, or initiate a calibration by sending a LOW to the CAL pin or writing a HIGH to D1. During Power Down Mode, a pulse on CS and WR will initiate a single conversion, then the ADC7802 will revert to power down. Table III shows how instructions can be transferred to the Special Function Register by driving HBE HIGH (with SFR HIGH) and initiating a write cycle (driving WR and CS LOW with RD HIGH.) The timing is shown in Figure 3. Note that writing to the SFR also initiates a new conversion. CONTROL LINES Table IV shows the functions of the various control lines on the ADC7802. The use of standard CS, RD and WR control signals simplifies use with most microprocessors. At the same time, flexibility is assured by availability of status information and control functions, both through the SFR and directly on pins. Table II shows the data in the Special Function Register that will be transferred to the output bus by driving HBE HIGH (with SFR HIGH) and initiating a read cycle (driving RD and CS LOW with WR HIGH as shown in Figure 4.) The Power Fail flag in the SFR is set when the power supply falls below about 3V. The flag also means that a new calibration has been started, and any data written to the SFR has been lost. Thus, the ADC7802 will again be in the Transparent Mode. Writing a LOW to D5 in the SFR resets the Power Fail flag. The Cal Error flag in the SFR is set when an overflow occurs during CS RD WR SFR HBE CAL BUSY OPERATION XXXXX 0 ↑1 X Initiates calibration cycle. XXXXXX0 Conversion or calibration in process. Inhibits new conversion from starting. 1XXXX1X None. Outputs in Hi-Z State. 01 0 ↑1 0 X 1 1 Initiates conversion. 001001X Low byte conversion results output on data bus. 001011X High byte conversion results output on data bus. 0101111 Write to SFR and rising edge on WR initiates conversion. 001111X Contents of SFR output on data bus. 010101X Reserved for factory use. 001101X Reserved for factory use. (Unpredictable data on data bus.) TABLE IV. Control Line Functions. PIN FUNCTION DESCRIPTION D0 Mode Status If LOW, Transparent Mode enabled for data latches. If HIGH, Latched Output Mode enabled. D1 CAL Flag If HIGH, calibration cycle in progress. D2 Reserved for factory use. D3 Power Down Status If HIGH, in Power Down Mode. D4 Reserved for factory use. D5 POWER FAIL Flag If HIGH, a power supply failure has occurred. (Supply fell below 3V.) D6 CAL ERROR Flag If HIGH, an overflow occured during calibration. D7 BUSY Flag If HIGH, conversion or calibration in progress. NOTE: These data are transferred to the bus when a read cycle is initiated with SFR and HBE HIGH. Reading the SFR with SFR HIGH and HBE LOW is reserved for factory use at this time, and will yield unpredictable data. TABLE II. Reading the Special Function Register. CS/WR SFR/HBE D0 D1 D3 D5 D7 D2/D4/D6 Enables Transparent Mode for Data Latches. LOW HIGH LOW X LOW X LOW LOW Enables Latched Output Mode for Data Latches. LOW HIGH HIGH X LOW X LOW LOW Initiates Calibration Cycle. LOW HIGH X HIGH LOW X LOW LOW Resets Power Fail flag. LOW HIGH X X LOW LOW LOW LOW Activates Power Down Mode LOW HIGH X X HIGH X LOW LOW NOTES: (1) In Power Down Mode, a pulse on CS and WR will initiate a single conversion, then the ADC7802 will revert to power down. (2) X means it can be either HIGH or LOW without affecting this action. Writing HIGH to D2, D3, D4 or D6, or writing with SFR HIGH and HBE LOW, may result in unpredictable behavior. These modes are reserved for factory use at this time. TABLE III. Writing to the Special Function Register.