AD800-10TO SENSORTECHNICS

Document overview

  • PDF pages: 2

Technical content

Page 1

First Sensor APD Data Sheet

Part Description AD800-10 TO

Order # 501233

Version 09-10-15

PDF page 1 diagram
PDF page 1 diagram

Features

Description

  • ø 800 µm active area

Circular active area APD chip with IR

  • High QE for λ = 850-1064 nm

enhanced sensitivity. Very low dark

  • Low noise

current due to guard ring diode.

  • Low slope multiplication curve

Metal can type hermetic TO5i package with clear glass window.

Application

RoHS

  • Pulsed 1064 nm laser detection

2011/65/EU

  • Laser range finding
  • Fluorescence detection

Spectral response (M = 100; 23 °C)

Absolute maximum ratings

PDF page 1 diagram
Symbol Parameter Min M
T STG Storage temp -55 12
T OP Operating temp -40* 10
M max Gain (I = 1 nA) P0 1000
I PEAK Peak DC current 0.

Max Unit °C 125 °C 100

mA 0.25

Schematic

PDF page 1 diagram

Electro-optical characteristics @ 23 °C

PDF page 1 diagram
Symbol Characteristic Test Condition
Active area
Active area
I D Dark current M = 100
C Capacitance M = 100
Responsivity M = 100; λ = 905 nm
Responsivity M = 100; λ = 1064 nm
t R Rise time M = 100; λ = 1064 nm; R = 50 Ω L
t R Cut-off frequency -3d B
V BR Breakdown voltage I = R 2 µA
Temperature coefficient

\* please note that depending on operation voltage APD operation at temperatures below -15°C may require sophisticated control circuit.

European, International Sales:

First Sensor AG

USA:

Peter-Behrens-Strasse 15 12459 Berlin Germany T +49 30 6399 2399 F +49 30 639923-752 sales.opto@first-sensor.com

First Sensor Inc. 5700 Corsa Avenue #105 Westlake Village CA 91362 USA T +1 818 706 3400 F +1 818 889 7053 sales.us@first-sensor.com

Page 2

First Sensor APD Data Sheet

ta Sheet

Part Description AD800-10 TO

00-10 TO # 501233

Order # 501233

sion 09-10-15

Version 09-10-15

Capacitance as fct of reverse bias (23 °C)

Quantum efficiency (23 °C)

PDF page 2 diagram

Application hints:

PDF page 2 diagram
  • Current should be limited by a protecting resistor or current limiting - IC inside the power supply
  • Guard ring should be connected to ground
  • For low light level applications blocking of ambient light should be used
  • For high gain applications bias voltage should be temperature compensated
  • Please consider basic ESD protection while handling
  • Use low noise read-out - IC
  • For further questions please refer to document "Instructions for handling and processing" and application notes for APDs and APD-Arrays

Package dimension:

Small quantities: Foam pad, boxed (12 cm x 16.5 cm)

Disclaimer: Due to our strive for continuous improvement, specifications are subject to change within our PCN policy according to JESD46C.

European, International Sales:

First Sensor AG

USA:

Peter-Behrens-Strasse 15 12459 Berlin Germany T +49 30 6399 2399 F +49 30 639923-752 sales.opto@first-sensor.com

First Sensor Inc. 5700 Corsa Avenue #105 Westlake Village CA 91362 USA T +1 818 706 3400 F +1 818 889 7053 sales.us@first-sensor.com