AD500-10 SENSORTECHNICS
Document overview
- PDF pages: 2
Technical content
Page 1
First Sensor APD Data Sheet
Part Description AD500-10 TO
Order # 500953
Version 09-10-15


Features
Description
- ø 500 µm active area
Circular active area APD chip with IR
- High QE for λ = 850-1064 nm
enhanced sensitivity. Very low dark
- Low noise
current due to guard ring diode.
- Low slope multiplication curve
Metal can type hermetic TO5i package with clear glass window.
Application
RoHS
- Pulsed 1064 nm laser detection
2011/65/EU
- Laser range finding
- Fluorescence detection
Spectral response (M = 100; 23 °C)
Absolute maximum ratings

| Symbol | Parameter | Min M |
|---|---|---|
| T STG | Storage temp | -55 12 |
| T OP | Operating temp | -40* 10 |
| M max | Gain (I = 1 nA) P0 | 1000 |
| I PEAK | Peak DC current | 0. |
Max Unit °C 125 °C 100
mA 0.25
Schematic

Electro-optical characteristics @ 23 °C

| Symbol | Characteristic | Test Condition |
|---|---|---|
| Active area | ||
| Active area | ||
| I D | Dark current M | = 100 |
| C | Capacitance M | = 100 |
| Responsivity M | = 100; λ = 905 nm | |
| Responsivity M | = 100; λ = 1064 nm | |
| t R | Rise time M | = 100; λ = 1064 nm; R = 50 Ω L |
| t R | Cut-off frequency -3d | B |
| V BR | Breakdown voltage I = R | 2 µA |
| Temperature coefficient |
\* please note that depending on operation voltage APD operation at temperatures below -15°C may require sophisticated control circuit.
European, International Sales:
First Sensor AG
USA:
Peter-Behrens-Strasse 15 12459 Berlin Germany T +49 30 6399 2399 F +49 30 639923-752 sales.opto@first-sensor.com
First Sensor Inc. 5700 Corsa Avenue #105 Westlake Village CA 91362 USA T +1 818 706 3400 F +1 818 889 7053 sales.us@first-sensor.com
Page 2
First Sensor APD Data Sheet
ta Sheet
Part Description AD500-10 TO
00-10 TO # 500953
Order # 500953
sion 09-10-15
Version 09-10-15
Capacitance as fct of reverse bias (23 °C)
Quantum efficiency (23 °C)

Application hints:

- Current should be limited by a protecting resistor or current limiting - IC inside the power supply
- Guard ring should be connected to ground
- For low light level applications blocking of ambient light should be used
- For high gain applications bias voltage should be temperature compensated
- Please consider basic ESD protection while handling
- Use low noise read-out - IC
- For further questions please refer to document "Instructions for handling and processing" and application notes for APDs and APD-Arrays
Package dimension:
Small quantities: Foam pad, boxed (12 cm x 16.5 cm)
Disclaimer: Due to our strive for continuous improvement, specifications are subject to change within our PCN policy according to JESD46C.
European, International Sales:
First Sensor AG
USA:
Peter-Behrens-Strasse 15 12459 Berlin Germany T +49 30 6399 2399 F +49 30 639923-752 sales.opto@first-sensor.com
First Sensor Inc. 5700 Corsa Avenue #105 Westlake Village CA 91362 USA T +1 818 706 3400 F +1 818 889 7053 sales.us@first-sensor.com