Features
- VIN Range: 2.7V to 5.5V
- <1.0µA of Shutdown
- 1MHz Switching Frequency
- Fully Independent Display Lighting
- Dual Mode 1X and 1.5X Charge Pump for Maximum Efficiency
- Drives Low-VF and High-VF Type LEDs
- Up to Six 20mA Outputs
- Multi-Position Brightness Scale with Digital Control
- Low Noise Constant Frequency Operation
- Small Application Circuit
- Regulated Output Current
- Automatic Soft Start
- No Inductors
- 16-Pin QFN44 Package
- -40°C to +85°C Temperature Range
Applications
- Color (RGB) Lighting
- Programmable Current Source
- White LED Backlighting
- White LED Photo Flash for Digital Still Cameras
High Efficiency 1X/1.5X Fractional Charge Pump for White LED Applications Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202138A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 5, 2012 Pin Descriptions Pin # Symbol Function 1 D2 Current source output #2. 2 D5 Current source output #5. 3 D6 Current source output #6. 4 D3 Current source output #3. 5 D4 Current source output #4. 6 C1+ Flying capacitor 1 positive terminal. Connect a 1µF capacitor between C1+ and C1-. 7 C1- Flying capacitor 1 negative terminal. 8, 13 N/C No connection. 9 OUT Charge pump output. Requires 1µF capacitor connected between this pin and ground. 10 C2+ Flying capacitor 2 positive terminal. Connect a 1µF capacitor between C2+ and C2-. 11 C2- Flying capacitor 2 negative terminal. 12 GND Ground. 14 IN Input power supply. Requires 1µF capacitor connected between this pin and ground. 15 EN/SET Control pin. 16 D1 Current source output #1. EP Exposed paddle (bottom); connect to GND directly beneath package. Pin Configuration QFN44-16 (Top View) C1+ C1- N/C OUT C2+ C2- GND N/C IN EN/SET
High Efficiency 1X/1.5X Fractional Charge Pump for White LED Applications Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202138A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 5, 2012 1. Stresses above those listed in Absolute Maximum Ratings may cause permanent damage to the device. Functional operation at conditions other than the operating conditions specified is not implied. Only one Absolute Maximum Rating should be applied at any one time. 2. Based on long-term current density limitation. 3. Mounted on an FR4 board. Absolute Maximum Ratings1 Symbol Description Value Units VIN Input Voltage -0.3 to 6.0 V VOUT Charge Pump Output -0.3 to 6.0 V FB, VEN/SET FB or EN/SET to GND Voltage -0.3 to 6.0 V VEN/SET(MAX) Maximum EN/SET to Input Voltage 0.3 V IOUT2 Maximum DC Output Current 150 mA TJ Operating Junction Temperature Range -40 to 150 °C Thermal Information3 Symbol Description Value Units qJA Thermal Resistance 50 °C/WqJC Thermal Resistance 15 PD Maximum Power Dissipation 2 W
High Efficiency 1X/1.5X Fractional Charge Pump for White LED Applications Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202138A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 5, 2012 1. The AAT3134 is guaranteed to meet performance specifications over the -40°C to +85°C operating temperature range and is assured by design, characterization, and correla - tion with statistical process controls. Electrical Characteristics1 VIN = 3.5V, CIN = COUT = C1 = C2 = 1.0µF; TA = -40°C to +85°C. Unless otherwise noted, typical values are TA = 25°C. Symbol Description Conditions Min Typ Max Units Input Power Supply VIN Operation Range 2.7 5.5 V ICC Operating Current 3.0V ≤ VIN ≤ 5.5V, Active, No Load Current 1.8 3.5 mA ISHDN Shutdown Current EN/SET = 0 1.0 µA IDX(MAX) Maximum Output Current VIN = 3.6, Code = 32 18 20 22 mA I(D-Match) Current Matching Between Any Two Outputs Charge Pump Section TSS Soft-Start Time 200 µs FCLK Clock Frequency 1000 kHz hCP Charge Pump Section Efficiency VIN = 3.5V, IOUT(TOTAL) = 120mA, Measured from IN to OUT 93 % EN/SET VEN(L) Enable Threshold Low 0.5 V VEN(H) Enable Threshold High 1.4 V TEN/SET LO EN/SET Low Time VEN/SET < 0.5 0.3 75 µs TEN/SET HI Minimum EN/SET High Time VEN/SET > 1.4 50 ns TOFF EN/SET Off Timeout VEN/SET < 0.5 500 µs Input Current EN/SET Input Leakage -1.0 1.0 µA
High Efficiency 1X/1.5X Fractional Charge Pump for White LED Applications Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202138A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 5, 2012 Typical Characteristics Unless otherwise noted, VIN = 3.5V, CIN = COUT = C1 = C2 = 1µF, TA = 25°C. Efficiency vs. Input Voltage (4x20mA) 100 Input Voltage (V) Efficiency (%) VDIODE = 3.3V VDIODE = 3.4V VDIODE = 3.5V VDIODE = 3.6V IDIODE vs. Input Voltage (4x20mA) Input Voltage (V) IDIODE (mA) VDIODE = 3.3V VDIODE = 3.4V VDIODE = 3.5V VDIODE = 3.6V Quiescent Current vs. Input Voltage 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 Input Voltage (V) Quiescent Current (mA) VDIODE = 3.3V VDIODE = 3.4V VDIODE = 3.5V VDIODE = 3.6V VIH and VIL vs. VIN 0.600 0.625 0.650 0.675 0.700 0.725 0.750 0.775 0.800 0.825 0.850 Input Voltage (V) VIH VIL
High Efficiency 1X/1.5X Fractional Charge Pump for White LED Applications Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202138A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 5, 2012 Typical Characteristics Unless otherwise noted, VIN = 3.5V, CIN = COUT = C1 = C2 = 1µF, TA = 25°C. Turn-On to Full-Scale Charge Pump Time (50µs/div) ENSET (1V/div) OUT (2V/div) VDIODE (1V/div) IIN (200mA/div) Turn-On to Full-Scale Load Switch Time (50µs/div) ENSET (1V/div) OUT (2V/div) VDIODE (2V/div) IIN (100mA/div) Charge Pump to Load Switch (80mA) Time (50µs/div) VIN (10mV/div) OUT (2V/div) VDIODE (2V/div) IIN (100mA/div) Load Switch to Charge Pump (80mA) Time (50µs/div) VIN (20mV/div) OUT (1V/div) VDIODE (1V/div) IIN (200mV/div) Turn-Off Time (200µs/div) ENSET (1V/div) VDIODE (2V/div) IIN (100mA/div) 80mA Load Characteristics Time (1µs/div) 20mV/div VIN OUT VDIODE
High Efficiency 1X/1.5X Fractional Charge Pump for White LED Applications Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202138A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 5, 2012 Functional Description The AAT3134 is a dual mode load switch (1X) and high efficiency (1.5X) fractional charge pump device intended for white LED backlight applications. The fractional charge pump consists of a low dropout linear voltage regulator followed by a 1.5X charge pump with multiple current source outputs. To maximize power conversion efficiency, an internal feedback control sensing circuit monitors the voltage required on the constant current source outputs. This control circuit then sets the load switch and charge pump functions based upon the input voltage level versus the output voltage level needed. This function significantly enhances overall device effi - ciency when the input voltage level is greater than the voltage required at the constant current source outputs. The 1X load switch/1.5X charge pump mode decision is based on the voltage levels sensed on either the D1 or D5 output, whichever is greater. Switchover between the 1.5X (charge pump) operating mode and the 1X (load switch) mode occurs automatically (as a function of input and output voltages) and does not require user intervention to maintain maximum efficiency. The AAT3134 requires only four external components: two 1µF ceramic capacitors for the charge pump flying capacitors (C1 and C2), one 1µF ceramic input capacitor (CIN), and one 0.33µF to 1µF ceramic output capacitor (COUT). The LDO/1.5X charge pump output is converted into four (D1 to D4) constant current outputs to drive four individual LEDs with a maximum current of 20mA each and two (D5 and D6) constant current outputs with a maximum current of 20mA. The current source output magnitude is controlled by the EN/SET serial data inter - face. The interface records rising edges of the EN/SET pin and decodes them into 32 addresses corresponding to individual current level settings. The 32 addresses are divided up such that outputs D1 to D4 can be controlled independently of outputs D5 to D6. For Addresses 1 to 6, 7 to 12, 13 to 18, 19 to 24, and 25 to 30, outputs D1 Functional Block Diagram 1X/1.5X Charge Pump Soft-Start Control 1MHz Oscillator Voltage Reference Quad Output DAC Dual Output DAC Current Reference S2Cwire Interface 32x16 bit ROM C1+ C1- C2+ C2- OUT GND EN/SET VIN 32x16 bit ROM
High Efficiency 1X/1.5X Fractional Charge Pump for White LED Applications Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202138A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 5, 2012 Output Current Level Settings Address Code Current (mA) Figure 1: Output Current Level Settings. to D4 start at 0mA and increase from 1mA to 20mA in four steps. Outputs D5 and D6 remain constant over these address ranges which provides orthogonal control of the two channels. For Addresses 1 to 6, D5 and D6 are set to 0mA, Addresses 7 to 12 are 1mA; Addresses 13 to 18 are 10mA; Addresses 19 to 24 are 12mA; and Addresses 25 to 30 are 15mA. For maximum brightness control, Addresses 31 and 32 set D5 and D6 to the maximum 20mA level. For design flexibility, D1 to D4 are set to 0mA at Address 31, and 20mA at Address 32. This is summarized in Table 1 and Figure 1. The modulo 32 interface wraps back to State 1 after the 32nd clock. With each EN/SET pulse, the output current changes to the next setting in the address decoding. To change settings to the previous address decoding, 31 EN/SET clock pulses are required. The counter can be clocked at speeds up to 1MHz, so that intermediate states are not visible. The first rising edge of EN/SET enables the IC and initially sets the output LED currents to 0mA. Additional clocks are required to set the desired current level. Once the final clock cycle is input for the desired brightness level, the EN/SET pin is held high to maintain the device output current at the programmed level. The device is disabled 500µs after the EN/SET pin transitions to a logic low state. Applications Information Constant Current Output Level Settings The constant current source output amplitude for output D1 to D4 and D5 to D6 are set via the serial interface according to the scale described in Figure 1 and the pre- vious section. Because the outputs D1 to D6 are true independent constant current sources, the voltage observed on any single given output will be determined by the actual forward voltage (V F) for the LED being driven. Since the output current of the AAT3134 is programma - ble through the S 2Cwire serial interface, no PWM (pulse width modulation) or additional control circuitry are needed to control LED brightness. This feature greatly reduces the burden on a microcontroller or system IC to manage LED or display brightness, allowing the user to “set it and forget it.” Furthermore, with its high-speed serial interface (1MHz data rate), the output current of the AAT3134 can be changed successively to brighten or dim LEDs in smooth transitions (e.g., to fade out) or in abrupt steps, giving the user complete programmability and real-time control of LED brightness.
High Efficiency 1X/1.5X Fractional Charge Pump for White LED Applications Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202138A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 5, 2012 EN/SET Timing Diagram EN/SET Code 1 2 3 OFFOFF tHI tLO tOFF Address Current Level Settings (mA) D1 to D4 D5 to D6 1 0 0 2 1 0 3 10 0 4 12 0 5 15 0 6 20 0 7 0 1 8 1 1 9 10 1 10 12 1 11 15 1 12 20 1 13 0 10 14 1 10 15 10 10 16 12 10 17 15 10 18 20 10 19 0 12 20 1 12 21 10 12 22 12 12 23 15 12 24 20 12 25 0 15 26 1 15 27 10 15 28 12 15 29 15 15 30 20 15 31 0 20 32 20 20 Table 1: Constant Current Source Output Programming Levels. EN/SET Serial Interface The current source output magnitude is controlled by the EN/SET serial interface. The interface records rising edges of the EN/SET pin and decodes them into 32 indi- vidual current level settings, as summarized in Table 1. The modulo 32 interface wraps back to State 1 after the 32nd clock, so that the previous state is achieved by clocking the EN/SET pin 31 times. The counter can be clocked at speeds up to 1MHz, so that intermediate states are not visible. The first rising edge of EN/SET enables the IC and initially sets the output LED current to 0. Once the final clock cycle is input for the desired brightness level, the EN/SET pin is held high to maintain the device output current at the programmed level. The device is disabled 500µs after the EN/SET pin transitions to a logic low state. The EN/SET timing is designed to accommodate a wide range of data rates. After the first rising edge of EN/SET, the charge pump is enabled and reaches full capacity after the soft-start time (T SS). During the soft-start time, multiple clock pulses may be entered on the EN/SET pin to set the final output current level with a single burst of clocks. Alternatively, the EN/ SET clock pulses may be entered one at a time to grad - ually increase the LED brightness over any desired time period. A constant current is sourced as long as EN/SET remains in a logic high state. The current source outputs are switched off after EN/SET has remained in a low state for at least the TOFF timeout period. LED Selection The AAT3134 is specifically intended for driving white LEDs. However, the device design will allow the AAT3134 to drive most types of LEDs with forward voltage speci - fications ranging from 2.0V to 4.3V. LED applications may include main and sub-LCD display backlighting, camera photo-flash applications, color (RGB) LEDs, infrared (IR) diodes for remotes, and other loads bene - fiting from a controlled output current generated from a varying input voltage. Since the D1 to D6 output current sources are matched with negligible voltage depen - dence, the LED brightness will be matched regardless of the specific LED forward voltage (VF) levels. In some instances (e.g., in high luminous output appli - cations such as photo flash), it may be necessary to drive high-VF type LEDs. The low dropout current sourc- es in the AAT3134 make it capable of driving LEDs with forward voltages as high as 4.3V at full current from an input supply as low as 3.0V. Outputs can be paralleled to drive high-current LEDs without complication.
High Efficiency 1X/1.5X Fractional Charge Pump for White LED Applications Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202138A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 5, 2012 Device Switching Noise Performance The AAT3134 operates at a fixed frequency of approxi - mately 1MHz to control noise and limit harmonics that can interfere with the RF operation of cellular telephone handsets or other communication devices. Back-injected noise appearing on the input pin of the charge pump is 20mV peak-to-peak, typically ten times less than induc- tor-based DC/DC boost converter white LED backlight solutions. The AAT3134 soft-start feature prevents noise transient effects associated with inrush currents during start-up of the charge pump circuit. Power Efficiency and Device Evaluation The charge pump efficiency discussion in the following sections only accounts for efficiency of the charge pump section itself. Due to the unique circuit architecture and design of the AAT3134, it is very difficult to measure efficiency in terms of a percent value comparing input power over output power. Since the AAT3134 outputs are pure constant current sources and typically drive individual loads, it is difficult to measure the output voltage for a given output (D1 to D6) to derive an overall output power measurement. For any given application, white LED forward voltage levels can differ, yet the output drive current will be maintained as a constant. This makes quantifying output power a difficult task when taken in the context of comparing to other white LED driver circuit topologies. A better way to quantify total device efficiency is to observe the total input power to the device for a given LED current drive level. The best white LED driver for a given application should be based on trade-offs of size, external components count, reliability, operating range, and total energy usage...not just % efficiency. The AAT3134 efficiency may be quantified under very specific conditions and is dependent upon the input volt- age versus the output voltage seen across the loads applied to outputs D1 through D6 for a given constant current setting. Depending upon V IN being greater than the specific voltage seen across the load on D1 (or D6), the device will operate in load switch mode. If VIN is less than the voltage required on the constant current source, the device will operate in 1.5X charge pump mode. Each of these two modes will yield different efficiency values. One should refer to the following two sections for expla- nations for each operational mode. Load Switch Mode Efficiency The AAT3134 load switch mode is operational at all times and functions alone to enhance device power conversion efficiency when the condition exists where V IN is greater than voltage across the load connected to the constant current source outputs. When in load switch mode, the voltage conversion efficiency is defined as output power divided by input power: η = POUT PIN The expression to define the ideal efficiency ( h) can be rewritten as: η = POUT = VOUT /uni2219 IOUT = VOUT PIN VIN /uni2219 IOUT VIN -or- η(%) = 100 VOUT VIN Charge Pump Section Efficiency The AAT3134 contains a fractional charge pump which will boost the input supply voltage when V IN is less than the voltage required on the constant current source out- puts. The efficiency (h) can be simply defined as a linear voltage regulator with an effective output voltage that is equal to one and one half times the input voltage. Efficiency (h) for an ideal 1.5X charge pump can typi - cally be expressed as the output power divided by the input power: η = POUT PIN In addition, with an ideal 1.5X charge pump, the output current may be expressed as 2/3 of the input current. The expression to define the ideal efficiency ( h) can be rewritten as: η = POUT = VOUT /uni2219 IOUT = VOUT PIN VIN /uni2219 1.5IOUT 1.5VIN -or- η(%) = 100 VOUT 1.5VIN
High Efficiency 1X/1.5X Fractional Charge Pump for White LED Applications Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202138A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 5, 2012 For a charge pump with an output of 5V and a nominal input of 3.5V, the theoretical efficiency is 95%. Due to internal switching losses and IC quiescent current con - sumption, the actual efficiency can be measured at 93%. These figures are in close agreement for output load conditions from 1mA to 100mA. Efficiency will decrease as load current drops below 0.05mA or when the level of V IN approaches V OUT. Refer to the Typical Characteristics section of this document for measured plots of efficiency versus input voltage and output load current for the given charge pump output voltage options. Capacitor Selection Careful selection of the four external capacitors C IN, C1, C2, and COUT is important because they will affect turn-on time, output ripple, and transient performance. Optimum performance will be obtained when low equivalent series resistance (ESR) ceramic capacitors are used. In gen - eral, low ESR may be defined as less than 100m W. A value of 1µF for all four capacitors is a good starting point when choosing capacitors. If the LED current sources are only programmed for light current levels, then the capacitor size may be decreased. Capacitor Characteristics Ceramic composition capacitors are highly recommend - ed over all other types of capacitors for use with the AAT3134. Ceramic capacitors offer many advantages over their tantalum and aluminum electrolytic counter - parts. A ceramic capacitor has very low ESR, is lowest cost, has a smaller PCB footprint, and is non-polarized. Low ESR ceramic capacitors help to maximize charge pump transient response. Since ceramic capacitors are non-polarized, they are not prone to incorrect connec - tion damage. Equivalent Series Resistance ESR is an important characteristic to consider when selecting a capacitor. ESR is a resistance internal to a capacitor that is caused by the leads, internal connec - tions, size or area, material composition, and ambient temperature. Capacitor ESR is typically measured in mil- liohms for ceramic capacitors and can range to more than several ohms for tantalum or aluminum electrolytic capacitors. Ceramic Capacitor Materials Ceramic capacitors less than 0.1µF are typically made from NPO or C0G materials. NPO and C0G materials have tight tolerance and are stable over temperature. Large capacitor values are typically composed of X7R, X5R, Z5U, or Y5V dielectric materials. Large ceramic capacitors, greater than 2.2µF, are often available in low-cost Y5V and Z5U dielectrics, but capacitors greater than 1µF are usually not required for AAT3134 applica - tions. Capacitor area is another contributor to ESR. Capacitors that are physically large will have a lower ESR when compared to an equivalent material smaller capacitor. These larger devices can improve circuit transient response when compared to an equal value capacitor in a smaller package size. Thermal Protection The AAT3134 has a thermal protection circuit that will shut down the internal LDO and charge pump if the die temperature rises above the thermal limit, as is the case during a short-circuit of the OUT pin.
High Efficiency 1X/1.5X Fractional Charge Pump for White LED Applications Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202138A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 5, 2012 C IN 1µF V BATTERY C OUT 1µF EN/SET 1µF 1µF D2 D3 D4 V IN V OUT C1+ C1- C2+ C2- EN/SET GND AAT3134 R B *R B *R B *R B * RR Resistor R is optional Resistor R is optional *In some applications, white LED forward voltages (V F ) can vary significantly. Ballast resistors between the LED cathodes and ground are recommended for balancing the forward voltage differences. The ballast resistor value may be approximated by the following equation: R B = V SOURCE - V F I F Figure 2: AAT3134 Driving Two Groups of Paralleled White LEDs (e.g., main and sub-LCD backlights).
High Efficiency 1X/1.5X Fractional Charge Pump for White LED Applications Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202138A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 5, 2012 Copyright © 2012 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Sky - works may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided here- under, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, IN - CLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or en- vironmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of pub- lished parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. 1. XYY = assembly and date code. 2. Sample stock is generally held on part numbers listed in BOLD. 3. The leadless package family, which includes QFN, TQFN, DFN, TDFN and STDFN, has exposed copper (unplated) at the end of the lead terminals due to the manufacturing process. A solder fillet at the exposed copper edge cannot be guaranteed and is not required to ensure a proper bottom solder connection.
Ordering Information
Package Marking1 Part Number (Tape and Reel)2 QFN44-16 JBXYY AAT3134ISN-T1 Skyworks Green™ products are compliant with all applicable legislation and are halogen-free. For additional information, refer to Skyworks Definition of Green™, document number SQ04-0074.
Package Information
3.000 ± 0.050 Pin 1 Dot By Marking 1.250 ± 0.050 0.400 ± 0.100 1.250 ± 0.0503.000 ± 0.050 0.500 ± 0.050 0.900 ± 0.100 Pin 1 Identification C0.3 0.025 ± 0.025 0.214 ± 0.036 0.230 ± 0.050 Top View Bottom View Side View All dimensions in millimeters.