X10784 UNITEDAUTOMATION

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(free datasheet download site)
  • PDF pages: 3

Technical content

YOU MUST READ THIS BEFORE INSTALLATION ELECTRICAL SAFETY INSTALLATION REQUIREMENTS USER RESTRICTIONS USAGE ENVIRONMENT HOT SURFACE WARNING WARNING: RISK OF ELECTRIC SHOCK Always consult the Installation & Maintenance Instructions before connecting this product to the power supply. WARNING: Disconnect Power Before Servicing Ensure the electrical supply is safely disconnected before connecting to any supply, load, or control terminals. WARNING: Installation by Qualified Personnel Only This product must only be installed or fitted by a competent, qualified installer familiar with the relevant electrical standards and installation practices. WARNING: Not for Use by Vulnerable Individuals This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are supervised or instructed by a person responsible for their safety. WARNING: Industrial Use Only This is an industrial-grade product and is not intended for household use. WARNING: Hot Surfaces On certain models, surfaces marked with this symbol become hot during use. Avoid direct contact and follow all thermal safety precautions. More Info: https://united-automation.com/general-product-safety-regulation-gpsr/

1 July 2025 | Issue: 11 Page 1 of 3

10A, 230V Fan and Pump Speed Controller with Signal Input 0044 (0) 1704-516 501 enquiries@united-automation.com www.united-automation.com CONTACT US: KEY FEATURES: Introducing our variable phase-angle regulator, designed for 230V, 10A single- phase mains driven inductive loads like induction motors, fans, and pumps. Enjoy fully adjustable voltage outputs from zero to maximum, alongside an integrated RC snubber network for precise control of inductive loads and a zero- set speed adjuster to prevent motor sluggishness. Featuring a large triac for handling high inrush currents, this regulator ensures safety in industrial installations. Upgrade your control system with our versatile variable phase-angle regulator, designed for optimal performance and safety in industrial settings.  Standard Din Rail mount for easy installation  Phase angle control for precise regulation  Integral protection for added safety.  Built-in snubber network for enhanced control  Compatible with input signals or Potentiometer (0- 5/0-10VDC 4-20mA)  Adjustable output power span and zero (Min Speed Set)  Power and status LEDs for clear monitoring  Supports loads up to 10A  Equipped with a built-in heatsink for efficient operation.  Integral RFI Filter. TECHNICAL SPECIFICATIONS Mains supply +/- 10% @ 50Hz 230VAC Maximum rms on-state current 10A Minimum operating current 200mA TRIAC limiting rms on state current 25A Peak one cycle surge @ 10mS 250A I²t for fusing 112 A²s Isolation voltage 2500V rms Maximum recommended unit temperature 70°C Minimum Signal Range 0-4V dc Maximum Signal Range 0-25V dc Signal zero offset (Min Speed) +60% and -40% of Span Manual potentiometer 5kΩ Typical Signal input resistance 5kΩ (“V” Signal), 250Ω (“mA” Signal) ±10% Trigger isolation voltage 2500V ac (RMS) Trigger pulse rating 250mA in to 10Ω Storage temperature 0°C to +65°C Max ambient operating temperature 70°C Dimensions (Inc DIN Enclosure) 127mm (D) by 72mm (H) by 94mm (W) Controller Heat Dissipation 1W/A APPLICATIONS:  Suitable for most simple mains-driven motors and fans.

X10784 Fan Speed Controllers FSC230/10 10A, 230V Fan and Pump Speed Controller with Signal Input BMF House - Wight Moss Way, Southport Business Park Southport PR8 4HQ ENGLAND, UNITED KINGDOM Contact Us:  0044 (0) 1704-516 501  enquiries@united-automation.com  www.united-automation.com unitedautomationltd UA_Limited 1 July 2025 | Issue: 11 Page 2 of 3 INSTALLATION - DIMENSIONS & CONNECTIONS SETUP AND OPERATION INPUT SIGNAL TERMINALS (5V, SIG I/P & 0V) The FSC230/10 supports the industry-standard signals inputs of 0-5V/0-10Vdc and 4- 20mA signal or a manual potentiometer. SPAN AND ZERO ADJUSTMENT The Span and Zero cermets (VR2 & VR3) allow the user to set the minimum and maximum output voltage in relation to the input signal range [see Typical Control Options]. LED INDICATORS The FSC230/10 has two LED indicators. The green ’DC ON’ is lit when power is supplied to the FSC230/10 and the red ‘STATUS’ illuminate proportionally in respect to the output.

X10784 Fan Speed Controllers FSC230/10 10A, 230V Fan and Pump Speed Controller with Signal Input BMF House - Wight Moss Way, Southport Business Park Southport PR8 4HQ ENGLAND, UNITED KINGDOM Contact Us:  0044 (0) 1704-516 501  enquiries@united-automation.com  www.united-automation.com unitedautomationltd UA_Limited 1 July 2025 | Issue: 11 Page 3 of 3 RECOMMENDATIONS FUSING It is recommended to use semiconductor (fast acting) type fuses or circuit breakers (Semiconductor - MCB) for unit protection. On initial switch on some loads may need an increased Factor of Safety (F of S) for unit and/or device protection. See SRA datasheet for information. DOCUMENTS Other documents available on request, which may be appropriate for your application: Code Identity Description X10213 ITA Interaction: Uses for phase angle and for burst fire control X10255 SRA Safety Requirements: Addressing the Low Voltage Directive (LVD) including, Thermal Data/Cooling, Live Parts Warning, Earthing Requirements and Fusing Recommendations It is recommended that installation and maintenance of this equipment should be done with reference to the current edition of the I.E.T. regulations (BS7671) by suitably qualified/trained personnel. The regulations contain important requirements regarding the safety of electrical equipment. For International standards refer STANDARDS on D of C. OPTIONAL EXTRAS Product Code Product Description A403001 Manual (5K) Potentiometer Knob and Leads L60018 PR Dial (0-10) PRODUCT CODE AND RELATED PRODUCT CODE 230V 10A Product Code Product Description A72290 FSC230/10 10A - 2.4kW 230v Fan Control Din Rail with RFI Note: FSC230/10 - Custom line voltages are available.