A4900 ALLEGRO

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 17

Technical content

NOTE: For detailed information on purchasing options, contact your local Allegro field applications engineer or sales representative. Allegro MicroSystems, LLC reserves the right to make, from time to time, revisions to the anticipated product life cycle plan for a product to accommodate changes in production capabilities, alternative product availabilities, or market demand. The information included herein is believed to be accurate and reliable. However, Allegro MicroSystems, LLC assumes no respon- sibility for its use; nor for any infringements of patents or other rights of third parties which may result from its use. Recommended Substitutions: no direct replacement High Voltage Three Phase Gate Driver A4900 For existing customer transition, and for new customers or new appli- cations, contact Allegro Sales. Date of status change: September 1, 2016 This device is no longer in production. The device should not be purchased for new design applications. Samples are no longer available. Discontinued Product

Description

The A4900 is a high-voltage, high-speed, power IGBT or MOSFET driver providing three independent half-bridge channels for three-phase applications. A bootstrap capacitor is used to provide the above battery supply voltage required for N-channel MOSFETs or IGBTs used as high current switches. Direct control over all six gate drives in the 3-phase bridge is provided, allowing motors to be driven with block commutation or sinusoidal excitation. The power switches are protected from cross-conduction by integrated crossover control and fixed dead time. Integrated diagnostics provide indication of undervoltage, overtemperature, and power bridge faults. They can be configured to protect the power switches under most short circuit conditions. Detailed diagnostics are available as a serial data word output. The A4900 is provided in a 44-pin QSOP package (suffix LQ) that is lead (Pb) free, with 100% matte tin leadframe plating. A4900-DS, Rev. 7 Features and Benefits

  • High voltage 3 -phase gate drive Floating high-s ide gate drive to 550 VDC supply T olerant to high voltage slew rates Cross-conduction protection w ith fixed dead time V gate drive supply voltage TTL compatible logic inputs Undervoltage d etection Overcurrent de tection with integrated fault blanking Overtemperatu re shutdown Matched propa gation delays Detailed fault r eporting High Voltage Three Phase Gate Driver Package: 44-pin QSOP (suffix LQ) Typical Application Diagram Not to scale A4900 3-Phase MotorA4900 VM Control Diagnostics VCC December 5, 2016

High Voltage Three Phase Gate DriverA4900 Allegro MicroSystems, LLC

115 Northeast Cutoff

Worcester, Massachusetts 01615-0036 U.S.A. Absolute Maximum Ratings with respect to GND Characteristic Symbol Notes Rating Unit Drive Supply Voltage VCC –0.3 to 20 V Logic Input and Output Voltage Pins AHI, ALO, BHI, BLO, CHI, CLO, COASTn, RESETn, ESF, FF1, and FF2 –0.3 to 6.5 V Other Pins Input and Output Voltage Pins BCA, BCB, BCC –0.3 to Sx+20 V Pins GHA, GHB, GHC Sx – 0.3 to BCx + 0.3 V Pins SA, SB, SC –VCC to 600 V Pins GLA, GLB, GLC –0.3 to VCC + 0.3 V Clamp Current IDCL Pins DHA, DHB, DHC, DLA, DLB, DLC 1 mA Maximum Voltage Slew Rate on Sx dv Sx/dt 50 V/ns Ambient Operating Temperature Range T A Temperature Range K –40 to 125 °C Maximum Continuous Junction Temperature T J(max) 150 °C Transient Junction Temperature TtJ Overtemperature event not exceeding s, lifetime duration not exceeding 10 characterized by design 175 °C Storage Temperature Range Tstg –55 to 150 °C Thermal Characteristics may require derating at maximum conditions, see application information Characteristic Symbol Test Conditions* Value Unit Package Thermal Resistance RθJA On 4-layer PCB based on JEDEC standard 35 ºC/W *Additional thermal information available on the Allegro website. Selection Guide Part Number Operating Ambient Temperature Range TA, (°C) Package Packing A4900KLQTR-T –40 to 125 44-pin QSOP 1000 pieces per 13-in. reel Table of Contents Pin-Out Diagram 3 T erminal List Table Functional Block Diagram T iming Diagrams Phase Control and Fault Tables Functional Description Terminal Functions 10 Power Supply 10 Gate Drive 11 High-side gate drive 11 Bootstrap capacitors 11 Low-side gate drive 11 Logic Control Inputs 11 Phase control 11 Sleep mode and reset 12 Diagnostics 12 Fault States 12 Overtemperature 12 VCC undervoltage 13 Bootstrap undervoltage 13 VDD undervoltage 13 VDS overvoltage 13 Fault Register Serial Access 14 Serial access method 14 Package Outline Drawing

High Voltage Three Phase Gate DriverA4900 Allegro MicroSystems, LLC Worcester, Massachusetts 01615-0036 U.S.A. Pin-out Diagram 396 SC GHC DHC BCC NC NC NC NC NC SB GHB DHB BCB NC NC NC NC NC SA GHA DHA BCA GLA GLB GND GLC GND VCC DLA DLB DLC COASTn CHI CLO BLO BHI TMUX TENA AHI ALO FF1 FF2 ESF RESETn Name Number Function AHI 28 Phase A high-side control logic input ALO 27 Phase A low-side control logic input BCA 22 Phase A high-side bootstrap supply capacitor (HVA) BCB 13 Phase B high-side bootstrap supply capacitor (HVB) BCC 4 Phase C high-side bootstrap supply capacitor (HVC) BHI 31 Phase B high-side control logic input BLO 32 Phase B low-side control logic input CHI 34 Phase C high-side control logic input CLO 33 Phase C low-side control logic input COASTn 35 Motor coast logic input, active low DHA 21 Phase A high-side drain voltage monitor input (HVA) DHB 12 Phase B high-side drain voltage monitor input (HVB) DHC 3 Phase C high-side drain voltage monitor input (HVC) DLA 38 Phase A low-side drain voltage monitor input DLB 37 Phase B low-side drain voltage monitor input DLC 36 Phase C low-side drain voltage monitor input Name Number Function ESF 24 Fail mode action control logic input FF1 26 Fault flag 1 open drain output FF2 25 Fault flag 2 open drain output GHA 20 Phase A high-side FET gate drive (HVA) GHB 11 Phase B high-side FET gate drive (HVB) GHC 2 Phase C high-side FET gate drive (HVC) GLA 44 Phase A low-side FET gate drive GLB 43 Phase B low-side FET gate drive GLC 41 Phase C low-side FET gate drive GND 40, 42 Ground NC 5, 6, 7, 8, 9, 14, 15, 16, 17, Do not connect RESETn 23 Reset and shutdown logic input, active low SA 19 Phase A high-side FET source and motor phase (HVA) SB 10 Phase B high-side FET source and motor phase (HVB) SC 1 Phase C high-side FET source and motor phase (HVC) TEST 29, 30 Connect to GND VCC 39 Gate drive supply Terminal List Table

High Voltage Three Phase Gate DriverA4900 Allegro MicroSystems, LLC Worcester, Massachusetts 01615-0036 U.S.A. VM ALO BHI BLO CHI CLO FF1 GLA GHA SA BCA Motor Supply + AHI VCC Phase A A4900 Phase A of 3 phases shown MOSFET or IGBT MOSFET or IGBT Phase C Phase B RGHA RGLA CBOOTA FF2 COASTn DHA RESETn ESF Control Logic Diagnostics and Protection UVLO, OTF Short to Supply Short to GND VCC VCC DLA Low-Side Drive GND High-Side Drive VDS Monitor VDS Monitor Functional Block Diagram

High Voltage Three Phase Gate DriverA4900 Allegro MicroSystems, LLC Worcester, Massachusetts 01615-0036 U.S.A. ELECTRICAL CHARACTERISTICS Valid at TJ = –40°C to 150°C, VCC = 15 V; unless otherwise specified Characteristic Symbol Test Conditions Min. Typ. Max. Unit Supply VCC Supply Voltage VCC 13.5 15 16.5 V VCC Quiescent Current IVCCQ RESETn = high, outputs = low – 8 10 mA IVCCS RESETn = low, sleep mode – – 80 µA High-Side Driver Current IBCxS Each phase – – 200 µA Gate Output Drive Pull-Up On-Resistance R DS(on)UP TJ = 25°C, IGHx = –100 mA – – 70 Ω Pull-Down On-Resistance RDS(on)DN TJ = 25°C, IGLx = 100 mA – – 35 Ω Output High Short Circuit Pulsed Current IOH VO = 0 V, short pulse width (<10 µs) – 210 – mA Output Low Short Circuit Pulsed Current I OL VO = 15 V short pulse width (<10 µs) – 420 – mA GHx Output High V oltage VGHH VBCx – 0.2 – – V GHx Output Low Voltage VGHL – – V Sx + 0.1 V GLx Output High Voltage VGLH VCC – 0.2 – – V GLx Output Low V oltage VGLL – – 0.1 V Turn-On Rise Time tr CLOAD = 1 nF, 20% to 80% – 90 150 ns T urn-Off Fall Time tf CLOAD = 1 nF, 80% to 20% – 40 85 ns T urn-Off Propagation Delay tP(off) Phase input change to unloaded gate output change (see figure 1) 250 300 500 ns COASTn low to unloaded gate output change 370 420 570 ns RESETn low to unloaded gate output change 250 300 500 ns Turn-On Propagation Delay t P(on) Phase input change to unloaded gate output change (see figure 1) 250 300 500 ns COASTn high to unloaded gate output change 0.8 1 1.3 µs Phase-to-Phase Propagation Delay Matching Δt PP Same phase change – 50 – ns On-to-Off Propagation Delay Matching ΔtOO Single phase – 50 – ns High-Side Passive Pull-Down RPDH – 800 – kΩ Low-Side Passive Pull-Down RPDL – 800 – kΩ Dead Time2 tDEAD Delay from turn-off to turn-on, single phase 130 200 330 ns Logic Inputs and Outputs FFx Fault Output (Open Drain) VOL IOL = 1 mA, fault not present – – 0.4 V Fault Output Leakage Current* IOH VO = 5 V, fault present –1 – 1 µA Input Low V oltage VIL – – 0.7 V Input High Voltage VIH 2.2 – – V Input Hysteresis VIhys 150 300 – mV Continued on the next page…

High Voltage Three Phase Gate DriverA4900 Allegro MicroSystems, LLC Worcester, Massachusetts 01615-0036 U.S.A. ELECTRICAL CHARACTERISTICS (continued) Valid at TJ = –40°C to 150°C, VCC = 15 V; unless otherwise specified Characteristic Symbol Test Conditions Min. Typ. Max. Unit Logic Inputs and Outputs (continued) Input Pull-Down Resistor RPD All digital inputs – 50 – kΩ RESETn Shutdown Time tRSD 10 – – µs RESETn Start-up Time tRSU – 15 20 µs Reset Hold-Off Delay Time tRHD – 5 – µs RESETn Pulse Time tRES 0.3 – 3.5 µs RESETn Pulse Filter Time tRF – – 200 ns Protection VCC Undervoltage Threshold VCCUVoff VCC falling 9 10 11 V VCCUVon VCC rising 10 11 12 V VCC Undervoltage Hysteresis V CCUVhys – 1 – V Bootstrap Undervoltage Threshold VBCUVoff BCx with respect to Sx, VBCx falling 9 10 11 V VBCUVon BCx with respect to Sx, VBCx rising 10 11 12 V Bootstrap Undervoltage Hysteresis V BCUVHys – 1 – V VDS Threshold VDSTH 1.8 2.0 2.2 V Drain Monitor Input Current IDMH VDM = 2.2 V (either VDM = VDHx – VSx , or VDM = VDLx ) – – 100 nA Drain Monitor Clamp Voltage VDMC – 5 – V Drain Monitor Blank Time tBL 2 3 4.5 µs Overtemperature Flag TJF Temperature increasing 155 170 – ºC Overtemperature Hysteresis TJHyst Recovery = TJF – TJHyst – 15 – ºC *For input and output current specifications, negative current is defined as coming out of (sourcing) the specified device pin.

Worcester, Massachusetts 01615-0036 U.S.A. Figure 1. Gate Drive Timing Figure 2. VDS Overvoltage Internal Monitor Timing

Worcester, Massachusetts 01615-0036 U.S.A. Figure 3. VDS Overvoltage Fault Timing Figure 4. General Faults FFx Timing

Worcester, Massachusetts 01615-0036 U.S.A. Table 1. Phase Control Truth Table

High Voltage Three Phase Gate DriverA4900 Allegro MicroSystems, LLC Worcester, Massachusetts 01615-0036 U.S.A. Functional Description The A4900 provides six gate drives, capable of driving a wide range of N-channel IGBT or power MOSFET switches. The gate drives are configured as three high-voltage high-side drives and three low-side drives. The high-side drives are isolated up to 600 V to allow operation with high bridge (motor) supply voltages. High-side drives use a bootstrap capacitor to provide the necessary gate drive voltage above the motor supply voltage. Each drive can be controlled with a TTL logic level input com- patible with 3.3 V or 5 V logic systems. A single supply input provides the gate drive supply and the bootstrap capacitor charge source. An internal regulator from the single supply provides the lower internal voltage for the logic circuit. The A4900 provides internal monitors to ensure that the gate-source voltage of both high-side and low-side external MOSFETs or IGBTs are above 9 V when active. The control inputs to the A4900 provide a very flexible solution for many motor control applications. Each driver can be driven with an independent PWM signal allowing implementation of all motor excitation methods including trapezoidal and sinusoi- dal drive. Diagnostics include short detection for the power switching devices, undervoltage detection for the key internal and external supplies and overtemperature detection. Two fault flags indicate three sets of faults and specific faults can be determined by read- ing a serial register. Specific functions are described more fully in the following sec- tions. Terminal Functions VCC Power supply for internal regulators and gate drive circuits. This supply also provides the charging source for the external bootstrap diodes. It should be decoupled with ceramic capacitors connected close to the VCC and GND terminals. GND Power, digital, and reference ground. Low-side return path for discharge of the capacitance on the MOSFET or IGBT gates. DHA, DHB, DHC High-side drain voltage sense input to the high- side VDS monitors. Typically connected to the drain via a resistor potential divider. BCA, BCB, BCC High-side connections for the bootstrap capaci- tors and positive supply for high-side gate drivers. GHA, GHB, GHC High-side, gate drive outputs for external N-channel MOSFETs or IGBTs. SA, SB, SC Motor phase connections that are the negative supply connections for the floating high-side drivers and returns for the high-side gate discharge current to the sources of the high-side switches. They also are connected to the negative side of the bootstrap capacitors and provide the reference offset voltage for the high-side V DS monitors. DLA, DLB, DLC Low-side drain voltage sense input to the low- side VDS monitors. Typically connected to the drain via a resistor potential divider. GLA, GLB, GLC Low-side gate drive outputs for external N-channel MOSFETs or IGBTs. AHI, ALO Logic inputs for phase A gate drive control. BHI, BLO Logic inputs for phase B gate drive control. CHI, CLO Logic inputs for phase C gate drive control. COASTn Active-low logic input that forces all gate drive outputs low, and turns all external power switches off. Overrides all gate drive control inputs. RESETn Active low logic input that resets faults when pulsed low. Allows low-power shutdown (sleep mode) when held low for more than the RESETn Shutdown Time, t RSD . FF1, FF2 Open drain fault flag outputs that indicate the presence of fault conditions. FF2 can be used as a clock input to read a serial register on FF1. ESF Enable stop-on-fail logic input that determines actions to be taken during overtemperature fault conditions. Power Supply All internal supplies and references are derived from a single power supply connection to VCC at 15 V (typ). A single ground connection provides the return path for the operating current and the low-side gate discharge currents. The ground terminal must have a low impedance, low inductance path to the system ground of the main power bridge. The VCC supply must be decoupled with ceramic capacitors connected close to the supply and ground terminals. The supply for the internal logic is provided by an inte- grated linear regulator which provides the internal logic supply voltage, V DD .

High Voltage Three Phase Gate DriverA4900 Allegro MicroSystems, LLC Worcester, Massachusetts 01615-0036 U.S.A. Gate Drive The A4900 is designed to drive external, N-channel power switching devices, either MOSFET or IGBT. It supplies the transient currents necessary to quickly charge and discharge the external gate capacitance in order to reduce dissipation in the external power device during switching. The charge and dis- charge rate is controlled using an external resistor in series with the connection to the gate of the power switching device. In the following sections the letter x is used to represent the phase: A, B or C. High-side gate drive The floating high-side gate drive outputs at the GHA, GHB, and GHC terminals are referenced to the voltage at the respective SA, SB, or SC terminal. An external resistor between the gate drive output and the gate connection to the power switching device controls the slew rate seen at the gate, thereby providing some control of the di/dt in the bridge and the dv/dt of the Sx terminal. GHx 1 (high) means that the upper half of the driver is turned on and the drain sources current to the gate of the high-side switching device in the external bridge, turning it on. GHx (low) means that the lower half of the driver is turned on and the drain sinks current from the gate of the external high-side switch- ing device to the respective Sx terminal, turning it off. When power is removed, a passive pull-down resistor between the GHx terminal and the corresponding Sx terminal ensures that the high-side switching device is held in the off state. Bootstrap capacitors The positive supply for the high-side gate driver on each phase is provided by a bootstrap capacitor, connected between the BCA and SA, BCB and SB, and BCC and SC terminals respectively. An external diode between the VCC terminal and each bootstrap capacitor is required to charge the capacitor when the associated output Sx terminal is low. The bootstrap capacitor is charged to approximately V CC – Vf , where VCC is the supply voltage at the VCC terminal and Vf is the forward voltage of the external block- ing diode. When the high-side switch is turned on, the voltage at the Sx terminal rises. This pushes the voltage at the other end of the bootstrap capacitor above V CC and the diode stops current flow- ing from the bootstrap capacitor back to the VCC supply. The diode must have a reverse breakdown rating in excess of the bridge supply voltage because the voltage at the BCx terminal will be above the bridge voltage when the respective high-side switch is turned on. After applying power or coming out of sleep mode, all three bootstrap capacitors must be charged before turning on any high- side switch. The capacitors can be charged by first turning on the three low-side switches for a short time. This will pull the Sx terminals low and allow the bootstrap diodes to apply a charging voltage across the capacitors. Low-side gate drive The low-side gate drive outputs at the GLA, GLB, and GLC terminals are referenced to the voltage at the GND terminal. An external resistor between the gate drive output and the gate connection to the power switching device controls the slew rate seen at the gate, thereby providing some control of the di/dt in the bridge and the dv/dt of the Sx terminal. GLx 1 (high) means that the upper half of the driver is turned on and the drain sources current to the gate of the low-side power switching device in the external power bridge, turning it on. GLx 0 (low) means that the lower half of the driver is turned on and the drain sinks current from the gate of the external low-side power switching device to the GND terminal, turning it off. When power is removed, a passive pull-down resistor between the GLx terminal and the GND terminal ensures that the low-side switching device is held in the off state. Logic Control Inputs There are seven logic inputs that directly control the bridge. Two additional inputs provide systems and diagnostic management. All logic inputs are TTL compatible to allow operation with 3.3 V and 5 V logic. All inputs have a hysteresis of 300 mV (typ) to improve noise performance and an internal pull-down resistor of 50 kΩ (typ) to ensure that the outputs are disabled if the input control signals are removed. Phase control Each phase is controlled independently with two control inputs for each phase. The xHI input controls the high-side drive and the xLO input controls the low-side drive. Internal lock-out logic ensures that the high-side output drive and low-side output drive cannot be active simultaneously. Table 1 shows the logic truth table. All gate drive outputs, GHx and GLx, can be forced low together by taking the COASTn input low. This turns all external power switching devices off and quickly disables the bridge in the event of a fault. COASTn does not clear any faults, so that the fault flags can be decoded and the serial fault word can be read. Because COASTn turns off all the external power switching

High Voltage Three Phase Gate DriverA4900 Allegro MicroSystems, LLC Worcester, Massachusetts 01615-0036 U.S.A. devices, it can also be used to provide fast decay PWM without synchronous rectification. If COASTn is held low, the high-side bootstrap capacitor may eventually become discharged and the high-side gate drive will then stop driving low. The high-imped- ance passive pull-down between the gate drive output and the corresponding source connection will then provide a discharge path to keep the high-side switch turned off. The low-side drive will remain active holding the low-side switch off. Sleep mode and reset When RESETn is held low for longer than the RESETn Shut- down Time, t RSD , all gate drive outputs will initially be driven low . After a period of time determined by the charge state and value of the bootstrap capacitor, the high-side gate drive will stop driving. The high-impedance passive pull-down between the high-side gate drive output and the corresponding source con- nection will then provide a discharge path to keep the high-side switch turned off. The low-side drive will drive low for the Reset Hold-Off Delay Time, t RHD , then stop driving. The high-imped- ance passive pull-down between the low-side gate drive output and the ground connection will then provide a discharge path to keep the low-side switch turned off. The regulator and all internal circuitry are then disabled and the A4900 enters sleep mode. In sleep mode the current consumption from the VCC supply is reduced to the minimum level, and the latched faults and corresponding fault flags are cleared. When coming out of sleep mode the protection logic ensures that the gate drive outputs are off until the internal regulators reach their correct operating conditions. When coming out of sleep mode all bootstrap capacitors must be charged before turning on any high-side switch, by first turning on the three low-side switches for a short time. RESETn can also be used to clear any faults in the Fault register, without entering sleep mode, by taking it low for the RESETn Pulse Time, t RES . Diagnostics Several diagnostic features are integrated into the A4900 to provide indication of fault conditions. In addition to system wide faults such as undervoltage and overtemperature, the A4900 integrates individual voltage monitors for each external power switching device. These are used to detect an overvoltage across the switching device when it is active, and to provide short circuit detection and protection. Fault conditions are indicated by the states of the two open drain output fault flags, FF1 and FF2, as shown in table 2. In the event that two or more faults are detected simultaneously, the states of the fault flags are determined by a logical OR of the fault state of each flag. When an undervoltage fault or a low-side switch overvoltage is detected, detailed fault information can be read from the fault outputs as a serial data word. When FF2 is high, a clock can be applied to FF2 and detailed fault information can be read from FF1 as a serial word. This can be used to determine on which of the three low-side external switching devices an overvoltage has been detected, or if a power-on reset or supply undervoltage has occurred. Fault register serial access operation is detailed in the Fault Register Serial Access section below. The state of the enable stop-on-fault logic input, ESF, determines the action taken when an overtemperature fault is detected. For other fault conditions the action is defined by the type of fault, as shown in table 2. Low-side switch overvoltage faults cause the fault flags and the relevant bit in the Fault register to be latched. For undervoltage faults the relevant bit in the Fault register is latched, but the flags are active only when the fault is present. For overtemperature faults the flags are active only when the fault is present. Fault States In addition to temperature, there are five voltage levels monitored in the A4900: the main supply voltage, the internally regulated logic supply voltage, and the voltage on each of the three high- side bootstrap capacitors. Overtemperature If the junction temperature exceeds the limit, 170°C (typ), FF1 goes high. When an overtemperature is detected, and ESF is high, the outputs are disabled automatically. If ESF is low, then no circuitry is disabled and the external controller must turn the outputs off or limit the power dissipation in some way so as to prevent overtemperature damage to the chip and unpredictable device operation. The overtemperature fault condition and the fault flags will be cleared only when the temperature drops below the recovery level, defined by T JF – TJHyst . Note that an overtem- perature fault does not permit access to the Fault register, because FF2 remains low.

High Voltage Three Phase Gate DriverA4900 Allegro MicroSystems, LLC Worcester, Massachusetts 01615-0036 U.S.A. VCC undervoltage VCC is the supply for the low-side gate driver and the boot- strap charge current. It is critical to ensure that the voltages are sufficiently high before enabling any of the outputs. The under- voltage monitor circuit is active during power up. Both fault flags are high and the motor is coasting (all gate drives low) until V CC is greater than approximately 11 V When a VCC undervoltage is detected, the fault flags and the fault register will be set and all gate drive outputs will be pulled low. When the VCC undervoltage condition is removed, the flags will be cleared and the outputs enabled. The VC bit in the Fault register will remain set until cleared by a register reset (see Fault Register Serial Access section, below). Bootstrap undervoltage The A4900 has three independent bootstrap voltage monitors, one for each phase. These monitor the individual bootstrap capacitor charge voltages to ensure sufficient high-side drive voltage. Each phase operates independently, such that a bootstrap undervoltage on one phase does not affect the other two phases. Before a high-side drive can be turned on, the voltage of the cor- responding bootstrap capacitor must be higher than the turn-on voltage limit, V BCUV on. If the bootstrap capacitor voltage is not above VBCUV on , the A4900 does not allow the high-side gate drive output to go high. The bootstrap voltage monitor for a phase remains active while a high-side gate drive output for that phase is commanded to be in the on state. If a high-side gate drive is high and the voltage of the corresponding bootstrap capacitor drops below the turn-off voltage, V BCUV off , then that high-side gate drive will be turned of f. The output will remain off until an off-to-on transition is commanded by the control logic and the bootstrap capacitor volt- age is above the turn-on voltage, V BCUV on . The bootstrap undervoltage fault state has no ef fect on the fault flag outputs or the Fault register. VDD undervoltage The internal logic supply voltage, VDD , is monitored to ensure correct logical operation. If an undervoltage of VDD is detected, then the state of other reported faults might not be valid, so all fault states, fault flags, and the Fault register are reset and replaced by the V DD undervoltage condition, and the outputs are disabled. When the VDD undervoltage condition is removed all flags will be cleared and the outputs will be enabled. VDS overvoltage Each of the six external power switching devices is provided with an independent overvoltage monitor, used to switch the device off if an overvoltage is detected. For each high-side power switching device, the monitor compares a fixed threshold voltage, V DSTH , to the dif ferential voltage between the DHx terminal and the Sx terminal. For each low-side power switching device, the monitor compares V DSTH to the voltage between the DLx terminal and the GND terminal. The output of the monitor comparator is high when the monitored voltage is greater than V DSTH , but is only valid when the associated switching device is turned on. Power MOSFETs and IGBTs take a finite time to reach their full conduction state, so the monitored voltage may remain above the threshold and show a fault as the power switching device is turned on. To overcome this and avoid false short fault detection, the output of a comparator is ignored until one V DS fault blank time, tBL, after the associated external switching device is turned on. If the monitored voltage remains above VDSTH after the VDS fault blank time, then a short fault will be detected. The monitored voltage is derived from the actual voltage across the power switching device using a resistor divider. This is necessary to prevent damage to the monitor input, either DHx or DLx, by the large differential voltage across the power switch- ing device when the it is off. The monitor input is clamped to the respective reference point with a 5 V clamp. For the high-side the clamps are between the DHx and Sx terminals. For the low-side the clamps are between the DLx and GND terminals. The values of the resistors in the monitor voltage divider must be selected to ensure that the current through the clamp is limited to less than the maximum value, I DCL . For example, a motor supply of 400 V means that the maximum voltage across the upper resistor in the divider will be 395 V . The current through the resistor must be less than 1 mA, so the resistor must be greater than 395 kΩ. If the required detection voltage across the power switching device is say 3 V , then the lower resistor in the divider must be 790 kΩ to achieve a monitor voltage of 2 V A short fault on either the high-side or the low-side always turns off the external switching device where the fault is detected, and holds it off until the control input is switched low then high again. This ensures that the overcurrent stress on the switching device is limited to a few microseconds after it is switched on. Only the low-side V DS overvoltage fault is indicated by the fault flags and captured in the Fault register. When a low-side fault is

High Voltage Three Phase Gate DriverA4900 Allegro MicroSystems, LLC Worcester, Massachusetts 01615-0036 U.S.A. present, the FF2 output is high and the associated (xL) bit in the Fault register is set. The FF2 output will remain high until reset. There are four ways the FF2 flag can be reset, assuming that the fault condition has been removed: Taking or pulsing RESETn low Taking the associated control input low A serial read A power on reset It is possible to disable the VDS overvoltage monitors by connect- ing the monitor input directly to its reference node (Sx or GND). This ensures that the monitor voltage is always zero so a fault is never detected. Any low-side V DS overvoltage fault always is latched in the Fault register until RESETn is low or a serial read is completed. (An undervoltage on the internal logic supply also will completely reset the short fault condition and the Fault register and replace it with a V DD undervoltage fault.) Fault Register Serial Access The fault flag outputs, FF1 and FF2, are open drain and passively pulled high when a fault has been detected. This makes it possible to allow one or both of these fault pins to be driven externally to a logic low during a fault condition, when the A4900 is not pull- ing the fault pin low. One of these fault flags, FF2, can be used as a clock input to shift out the status of the Fault register, bit by bit, on the other fault flag FF1. When FF2 is pulled low by the A4900, either when no fault has been detected or when only an overtemperature fault is present, then no serial access is possible. The Fault register can be accessed only when FF2 goes high. This occurs when a low-side V DS overvoltage, or a VCC or VDD undervoltage, fault has been detected (see table 2). Serial access method FF1 and FF2 are monitored by the external controller. If FF2 goes high and FF1 remains low, then a low-side VDS overvoltage has been detected. If FF1 and FF2 go high together, then a VCC or V DD undervoltage has been detected. In either case the A4900 response sequence will be: 1. External controller takes any necessary additional action to protect the external MOSFETs or IGBTs. 2. Controller pulls FF2 low. A4900 responds by outputting the first bit of the Fault register, POR , on FF1. 3. Controller reads the fault bit and toggles FF2 high then low to request the next bit, AL. This continues for each of the 5 bits in the Fault register. 4. After the final bit, VC, is output on FF1, the controller takes FF2 high then low once more. Assuming that no fault condi- tions are present, the A4900 resets the Fault register and pulls FF1 and FF2 low to indicate no fault present. 5. Controller releases FF2. The basic sequences for the three possible states of FF1 and FF2 are shown in figure 4. At the end of the serial transfer, on the last high to low transition input to FF2, the Fault register and the fault flags are reset. How- ever it is possible that one of the three unlatched fault conditions, VCC undervoltage, V DD undervoltage, or overtemperature, is still present. In this case the fault flags will immediately show the fault status. If a V DD undervoltage occurs then both fault flags will be high, the POR bit will be set, and the remaining bits in the Fault regis- ter will be reset.

High Voltage Three Phase Gate DriverA4900 Allegro MicroSystems, LLC Worcester, Massachusetts 01615-0036 U.S.A. Package LQ, 44-Pin QSOP SEATING PLANE 2.64 2.44 17.93 17.73 7.60 7.40 10.51 10.11 0.30 0.10 0.51 0.28 0.36

0.80 NOM

0.32 0.23 1.27 0.40 C0.10 44X Terminal #1 mark area For Reference Only; not for tooling use (QSOP, nonJEDEC standard) Dimensions in millimeters Dimensions exclusive of mold flash, gate burrs, and dambar protrusions Exact case and lead configuration at supplier discretion within limits shown B A 2 1 GAGE PLANE SEATING PLANE A B Standard Branding Reference View YYWW LLLLLLLLLLLLLLL NNNNNNNNNNNNNNN N = Device part number = Supplier emblem Y = Last two digits of year of manufacture W = Week of manufacture L = Lot identifier Branded Face Branding scale and appearance at supplier discretion C 9.50 0.800.60 2.20 2 1 PCB Layout Reference ViewC Reference land pattern layout (reference IPC7351 SOP80P1034X264-44M); All pads a minimum of 0.20 mm from all adjacent pads; adjust as necessary to meet application process requirements and PCB layout tolerances; when mounting on a multilayer PCB, thermal vias at the exposed thermal pad land can improve thermal dissipation (reference EIA/JEDEC Standard JESD51-5)

High Voltage Three Phase Gate DriverA4900 Allegro MicroSystems, LLC Worcester, Massachusetts 01615-0036 U.S.A. Copyright ©2016, Allegro MicroSystems, LLC Allegro MicroSystems, LLC reserves the right to make, from time to time, such departures from the detail specifications as may be required to permit improvements in the performance, reliability, or manufacturability of its products. Before placing an order, the user is cautioned to verify that the information being relied upon is current. Allegro’s products are not to be used in life support devices or systems, if a failure of an Allegro product can reasonably be expected to cause the failure of that life support device or system, or to affect the safety or effectiveness of that device or system. The information included herein is believed to be accurate and reliable. However, Allegro MicroSystems, LLC assumes no responsibility for its use; nor for any infringement of patents or other rights of third parties which may result from its use. For the latest version of this document, visit our website: www.allegromicro.com