X10222 UNITEDAUTOMATION

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(free datasheet download site)
  • PDF pages: 2

Technical content

V YOU MUST READ THIS BEFORE INSTALLATION ELECTRICAL SAFETY INSTALLATION REQUIREMENTS USER RESTRICTIONS USAGE ENVIRONMENT HOT SURFACE WARNING WARNING: RISK OF ELECTRIC SHOCK Always consult the Installation & Maintenance Instructions before connecting this product to the power supply. WARNING: Disconnect Power Before Servicing Ensure the electrical supply is safely disconnected before connecting to any supply, load, or control terminals. WARNING: Installation by Qualified Personnel Only This product must only be installed or fitted by a competent, qualified installer familiar with the relevant electrical standards and installation practices. WARNING: Not for Use by Vulnerable Individuals This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are supervised or instructed by a person responsible for their safety. WARNING: Industrial Use Only This is an industrial-grade product and is not intended for household use. WARNING: Hot Surfaces On certain models, surfaces marked with this symbol become hot during use. Avoid direct contact and follow all thermal safety precautions. More Info: https://united-automation.com/general-product-safety-regulation-gpsr/

1 July 2025 | Issue: 10 Page 1 of 2

TRIGGER MODULES | SINGLE PHASE | PHASE TO PHASE FC11AL X10222 Up to 440V Universal Phase Angle Controller 0044 (0) 1704-516 501 enquiries@united-automation.com www.united-automation.com CONTACT US: KEY FEATURES: The FC11AL is a versatile single-phase or phase-to-phase firing module designed for precise control of inductive loads through variable phase-angle modulation. With its adjustable signal matching and soft-start capabilities, this module is perfect for applications requiring smooth and controlled power delivery, such as ovens, hospitality equipment, heat lamps, and industrial dryers. The FC11AL features the innovative MONO-LINK™ firing system, which ensures reliable operation with minimal wiring, making it an ideal choice for environments where reliability and ease of installation are paramount. The module's fully enclosed design enhances safety and durability, making it suitable for industrial settings. The FC11AL Phase-Angle Firing Module is the go-to solution for professionals seeking reliable, adjustable power control in demanding industrial and commercial applications. Its robust design, coupled with advanced features like the MONO-LINK™ system, ensures optimal performance and long-term durability.  Versatile Power Control: Supports phase-angle firing for triacs or thyristors up to 440V AC, ideal for inductive loads like transformers and motors.  MONO-LINK™ Firing System: Unique gate-to- gate firing method reduces wiring complexity and enhances reliability.  High Isolation: Opto- coupled output with a 4000Vrms isolation voltage ensures safe and stable operation.  Adjustable Soft Start: Smoothly ramps up power delivery with an adjustable soft-start function (0-20 seconds), protecting sensitive equipment.  Status LED.  Durable and Safe. TECHNICAL SPECIFICATIONS Signal Span Minimum 0 to 2V dc Signal Span Maximum 0 to 25V dc Signal zero offset 0 to 30% of span dV/dt rating 100V/µs Max. Gate/Line voltage 440V ac Trigger isolation voltage 4000Vrms Trigger output rating 0.8A Storage temperature range -20 to +85°C AC input supply 12 to 18V ac @ 65mA Auxiliary output 5V dc Line Frequency 50/60 Hz Operating temperature range 0 to +65°C Adjustable soft start 0-20 seconds Mono-link fuse F100mA (HRC) Manual potentiometer 2K, 5K or 10K Power connections 6.3mm Amp tags APPLICATIONS: Ideal for a wide range of industrial and commercial applications, including:

  • Industrial Ovens
  • Restaurant and Hospitality
  • Quartz and Heat Lamps
  • Moulders and Dryers
  • Inductive Loads

X10222 TRIGGER MODULES | SINGLE PHASE | PHASE TO PHASE FC11AL Up to 440V Universal Phase Angle Controller BMF House - Wight Moss Way, Southport Business Park Southport PR8 4HQ ENGLAND, UNITED KINGDOM Contact Us:  0044 (0) 1704-516 501  enquiries@united-automation.com  www.united-automation.com unitedautomationltd UA_Limited 1 July 2025 | Issue: 10 Page 2 of 2 INSTALLATION CONNECTIONS RECOMMENDATIONS FUSING It is recommended that semiconductor, fast-acting type fuses or circuit breakers (Semiconductor-MCB) be used for unit protection. On initial operation some loads may need an increased Factor of Safety (F of S) for unit and/or device protection. See the SRA datasheet for further information. DOCUMENTS Other documents available on request, which may be appropriate for your application: Code Identity Description X10229 RFI Filter recommendations: Addressing the EMC Directive X10213 ITA Interaction: Uses for phase angle and for burst fire control X10255 SRA Safety Requirements: Addressing the Low Voltage Directive (LVD) including, Thermal Data/Cooling, Live Parts Warning, Earthing Requirements and Fusing Recommendations P01.1 COS UAL Conditions of Sale It is recommended that installation and maintenance of this equipment should be done with reference to the current edition of the I.E.T. regulations (BS7671) by suitably qualified/trained personnel. The regulations contain important requirements regarding the safety of electrical equipment. For International standards refer STANDARDS on D of C. OPTIONAL EXTRAS Product Code Product Description A-EN2010-30-S RFI Filter T30201 Supply Transformer Z01062 Heatsink Compound Syringe (Must be applied while fitting) Note: When ordering a filter, the current at which the FC11AL/2 is to be used at will be required. PRODUCT CODE AND RELATED PRODUCT CODE Product Code Product Description A31214 FC11ALL - Phase-Angle Firing Module