Page 1

6.81

MIL-C-17G QPL Cable

Twinax

UL NEC/ C(UL) CEC Type Standard Lengths Standard Unit Weight Conductor (stranding) Diameter Nom. DCR Nominal Core OD Shielding Materials Nom. DCR Nominal OD Nom. Imp. (Ω) Nom. Vel. of Prop. Nominal Capacitance Nominal Attenuation
Ft. m Lbs. kg Inch mm Inch mm pF/Ft. pF/m MHz dB/ 100 Ft. dB/ 100m

Part

Description

No.

Twinax • 24 AWG Stranded (19x36) .024″ Silver-coated High-Strength Copper Alloy Conductor • SCHSCA Braid Shield (93% Coverage) TFE Teflon® Insulation • Blue PFA Jacket (Color Code: White, Blue)

500 † 152.4

81553 200°C

—

9.0 4.1 24 AWG

1000 † 304.8 16.0 7.3 (19x36)

.024″ SCHSCA 24.0Ω/M′ 78.7Ω/km

M17/176-00002

1 1.2 3.9

.084 2.13 SCHSCA .129 3.28 77 70% 24.0 78.7

10 4.0 13.1

93% Shield

50 9.2 30.2

Coverage

100 13.0 42.7

7.3Ω/M′

200 18.4 60.4

24.0Ω/km

400 26.1 85.6 700 34.6 113.5 900 39.3 128.9 1000 41.4 135.8

Twinax • 20 AWG Stranded (7x28) .038″ Tinned Copper Conductor • Tinned Copper Braid Shield (85% Coverage) Polyethylene Insulation • Black Non-contaminating PVC Jacket (One conductor has bare strand for ID)

1 .7 2.3

9859 85°C

— 1000 304.8 33.0 15.0 20 AWG

.158 4.01 TC Braid .235 5.97 78 66% 19.7 64.6

10 2.3 7.5

(7x28)

85% Shield

50 5.2 17.1

.038″

Coverage

100 7.5 24.6

TC

5.3Ω/M′

200 11.0 36.1

9.5Ω/M′

17.4Ω/km

400 16.0 52.5

31.2Ω/km

M17/45-RG108 DCR = DC Resistance • PFA = Perfluoroalkoxy • SCHSCA = Silver-coated High-strength Copper Alloy • TC = Tinned Copper • TFE = Tetra Fluoroethylene Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. †Spools may contain more than one piece. Minimum length of any one piece is 50 ft. Length may vary ±10% from length shown for spools or reels and ±5% UnReel® cartons.

Not RoHS compliant at time of printing. Please check with Belden Technical Support for current compliance information at 1-800-BELDEN-1.

Teflon is a DuPont trademark.

Page 2

6.82

Special Audio, Communication and Instrumentation Cable

Miniature Instrumentation and Low Triboelectric Noise Coax

UL NEC/ C(UL) CEC Type Standard Lengths Standard Unit Weight Conductor (stranding) Diameter Nom. DCR Nominal Core OD Shielding Materials Nom. DCR Nominal OD Nom. Imp. (Ω) Nom. Vel. of Prop. Nominal Capacitance Nominal Attenuation
Ft. m Lbs. kg Inch mm Inch mm pF/Ft. pF/m MHz dB/ 100 Ft. dB/ 100m

Part

Description

No.

Miniature • 28 AWG Solid .013″ Tinned Copper Conductor • Bare Copper Braid Shield (90% Coverage) Polypropylene Insulation • Black PVC Jacket 8700 105°C

NEC: 250 76.2 .8 .3 28 AWG .023 .58

VW-1

CMH

(solid)

CEC:

.013″

CMH FT1

TC 66.9Ω/M′ 219.5Ω/km

1 2.5 8.2

BC Braid .054 1.37 32 66% 55.2 181.1

10 7.7 25.3

90% Shield

50 17.2 56.4

Coverage

100 24.5 80.4

28.7Ω/M′

200 34.8 114.2

94.2Ω/km

400 50.0 164.4 700 66.0 216.5 900 75.0 246.1 1000 79.0 259.2

Low Noise • RG-174/U Type • 26 AWG Stranded (7x34) .019″ Bare Copper-covered Steel Conductor • TC Braid Shield (90% Coverage) Polyethylene Insulation • Conductive Layer • Black PVC Jacket 9239 60°C

— 100 30.5 1.0 .5 26 AWG .044 1.12

TC Braid .101 2.57 50 62% 38 125 — — —

500 152.4

4.5 2.0 (7x34)

90% Shield

1000 304.8

8.0 3.6 .019″

Coverage

BCCS

14.0Ω/M′

97.0Ω/M′

45.9Ω/km

318.3Ω/km

5mV peak-to-peak max. Not recommended for RF use.

Low Noise • RG-59/U Type • 22 AWG Solid .025″ Bare Copper-covered Steel Conductor • Bare Copper Braid Shield (93% Coverage) Polyethylene Insulation • Conductive Layer • Black PVC Jacket 9224 —

75°C

U-500 U-152.4 19.5 8.9 22 AWG .146 3.71

BC Braid .242 6.15 75 65% 22 72

— — —

VW-1

1000 304.8 39.0 17.7

(solid)

93% Shield

.025″

Coverage

BCCS

2.5Ω/M′

54.0Ω/M′

8.2Ω/km

177.0Ω/km

5mV peak-to-peak max. Not recommended for RF use.

Low Noise • RG-58/U Type • 22 AWG Stranded (7x30) .030″ TC Conductor • Duobond® II + TC Braid Shield (95% Coverage) Polyethylene Insulation • Conductive Layer • Black PVC Jacket 9223 80°C

— 100 30.5 3.4 1.5 22 AWG .112 2.85

Duobond II\* .195 4.95 50 56% 37 122 — — —

VW-1

500 152.4 12.0 5.4

(7x30)

+ 95%

1000 304.8 24.0 10.9

.030″

TC Braid

TC

100% Shield

10.8Ω/M′

Coverage

35.4Ω/km

4.1Ω/M′ 13.5Ω/km

8mV peak-to-peak max. Not recommended for RF use. BC = Bare Copper • BCCS = Bare Copper-covered Steel • DCR = DC Resistance • TC = Tinned Copper Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. \*Duobond II = Bonded Duofoil® (100% coverage) + aluminum braid (67% coverage).

Page 3

6.83

50 Ohm Ethernet® Coax

UL NEC/ C(UL) CEC Type Standard Lengths Standard Unit Weight Conductor (stranding) Diameter Nom. DCR Nominal Core OD Shielding Materials Nom. DCR Nominal OD Nom. Imp. (Ω) Nom. Vel. of Prop. Nominal Capacitance Nominal Attenuation
Ft. m Lbs. kg Inch mm Inch mm pF/Ft. pF/m MHz dB/ 100 Ft. dB/ 100m

Part

Description

No.

Thinnet 10Base2 Ethernet • 20 AWG Stranded (19x32) .037″ Conductor • Duobond® II + Overall TC Braid Shield (93% Coverage) Non-plenum • Foam Polyethylene Insulation • Gray PVC Jacket 9907 UL AWM

NEC: 500 152.4 12.5 5.7 20 AWG

Style 1354

CL2 U-1000 U-304.8 24.0 10.9 (19x32)

(30V 60°C)

CM 1000 304.8 23.0 10.4

.037″

CEC: 1640 500.0 41.0 18.6

TC

CM 2500 762.0 62.5 28.4 8.8Ω/M′ 3280 1000.0 82.0 37.3 28.9Ω/km

RG-58A/U Type DEC Part No. 17-01248-00

1 .4 1.4

.102 2.59 Duobond II\* .185 4.70 50 80% 25.4 83.3

10 1.3 4.3

+ 93%

50 2.9 9.5

TC Braid

100 4.2 13.8

5.8Ω/M′

For Plenum versions

200 6.1 20.0

19.0Ω/km

see 89907 or 82907.

400 8.9 29.2 700 12.1 39.7 900 13.9 45.6 1000 14.8 48.6

Plenum • Foam FEP Insulation • Gray Fluorocopolymer Jacket 89907 150°C

NEC: 500 152.4 11.0 5.0 20 AWG 1000 † 304.8 22.0 10.0 (19x32) CMP 2500 † 762.0 60.0 27.3

.037″

CL2P CEC:

TC

CMP FT6

8.8Ω/M′ 28.9Ω/km

RG-58A/U Type DEC Part No. 17-01246-00. Suitable for Outdoor applications. Plenum • FPFA Insulation • Natural Flamarrest® Jacket

500 † 152.4 11.0 5.0 20 AWG

82907 75°C

NEC: CMP U-1000 †† U-304.8 23.0 10.5 (19x32) 1000 † 304.8 22.0 10.0

.037″

CL2P 2500 † 762.0 57.5 26.1

TC

CEC: CMP FT6

8.8Ω/M′ 28.9Ω/km

RG-58A/U Type

1 .4 1.4

.095 2.41 Duobond II\* .160 4.06 50 80% 25.4 83.3

10 1.3 4.3

+ 93%

50 2.9 9.5

TC Braid

100 4.2 13.7

5.8Ω/M′

200 6.1 20.0

For Non-plenum version see 9907.

19.0Ω/km

400 9.2 30.2 700 12.9 42.3 900 15.0 49.2 1000 16.0 52.5

1 .4 1.4

.095 2.41 Duobond II\* .160 4.06 50 80% 25.4 83.3

10 1.3 4.3

+ 93%

50 2.9 9.5

TC Braid

100 4.2 13.7

5.8Ω/M′

200 6.1 20.0

For Non-plenum version see 9907.

19.0Ω/km

400 9.2 30.2 700 12.9 42.3 900 15.0 49.2 1000 16.0 52.5

Thicknet 10Base5 Ethernet • 12 AWG Solid .086″ Bare Copper Conductor • Duobond IV Quad Shield (100% Coverage) Non-plenum • Foam Polyethylene Insulation • Yellow PVC Jacket 9880 UL AWM

NEC: 500 152.4 66.0 30.0 12 AWG

Style 1478

CL2 1000 304.8 131.0 59.5

(solid)

(30V 60°C)

CM 1640 500.0 219.8 99.7

.086″

CEC:

BC

CM

1.4Ω/M′ 4.7Ω/km

DEC Part No. 17-00451-00 Ring-band stripes marked every 2.5 meters to aid users in tap placement.

1 .2 .6

.243 6.17 Duobond IV\* .405 10.29 50 78% 26.0 85.3

5 .4 1.2

(Duobond II

10 .5 1.7

+ 94% TC Braid

50 1.2 3.9

+ Duofoil ®

100 1.7 5.6

+ 90% TC

200 2.6 8.4

For Plenum version see 89880.

Braid)

400 3.9 12.8

1.5Ω/M′

700 5.5 18.1 900 6.5 21.3

5.0Ω/km

1000 6.9 22.6

Plenum • Foam FEP Insulation • Orange Fluorocopolymer Jacket 89880 150°C

NEC: 1000 304.8 134.0 60.9 12 AWG 1640 † 500.0 224.7 102.1

(solid)

CL2P CMP

.086″

CEC:

BC

CMP FT6

1.4Ω/M′ 4.7Ω/km

DEC Part No. 17-00324-00 Ring-band stripes marked every 2.5 meters to aid users in tap placement. Suitable for Outdoor and Direct Burial applications.

1 .2 .6

.245 6.22 Duobond IV\* .375 9.53 50 78% 26.0 85.3

5 .4 1.2

(Duobond II

10 .5 1.7

+ 90% TC Braid

50 1.2 3.8

+ Duofoil

100 1.7 5.4

+ 90% TC

200 2.5 8.0

Braid)

400 3.8 12.5

1.5Ω/M′

700 5.6 18.4 900 6.8 22.3

5.0Ω/km

1000 7.2 23.6

BC = Bare Copper • DCR = DC Resistance • FEP = Fluorinated Ethylene Propylene • FPFA = Foam Perfluoroalkoxy • TC = Tinned Copper Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. For cable manufactured to latest government revision or other MIL-SPEC requirements, please contact your nearest Belden Regional Sales Office. \*Duobond II = Bonded Duofoil® (100% coverage) + aluminum braid (67% coverage). Duobond IV = Bonded Duofoil (100% coverage) + aluminum braid (67% coverage) + Duofoil (100% coverage) + aluminum braid (46% coverage). †Final put-up length may vary from length shown ±10% for spools and reels, ±5% for UnReel® cartons.

††Length may vary -0/+10%.

Page 4

6.84

75 Ohm Coax

UL NEC/ C(UL) CEC Type Standard Lengths Standard Unit Weight Conductor (stranding) Diameter Nom. DCR Nominal Core OD Shielding Materials Nom. DCR Nominal OD Nom. Imp. (Ω) Nom. Vel. of Prop. Nominal Capacitance Nominal Attenuation
Ft. m Lbs. kg Inch mm Inch mm pF/Ft. pF/m MHz dB/ 100 Ft. dB/ 100m

Part

Description

No.

75 Ohm • 30 AWG Stranded (7x38) .012″ Silver-plated Copper-covered Steel Conductor • Silver-plated Copper Braid Shield (95% Coverage) TFE Teflon® Insulation • White TFE Tape Jacket

100 †

83267 200°C

—

30.5 1.9 .9 30 AWG .063 1.60 1000 † 304.8 11.0 5.0

(7x38)

VW-1

.012″ SPCCS 244.0Ω/M′ 801.0Ω/km

RG-187A/U Type • MIL-C-17D

1 3.0 9.8

SPC Braid .103 2.62 75 69.5% 19.5 64.0

10 5.3 17.4

95% Shield

50 8.5 27.9

Coverage

100 10.0 32.8

8.6Ω/M′

200 12.5 41.0 400 16.0 52.5

28.2Ω/km

700 19.7 64.6 900 22.3 73.2 1000 24.0 78.7

75 Ohm • Dual RG-59/U Type • 23 AWG Solid .023″ Bare Copper-covered Steel Conductors • Bare Copper Braid Shield (95% Coverage) Flame-retardant Semi-foam Polyethylene Insulation • Black PVC Jacket 9555 UL AWM

NEC: 500 152.4 38.5 17.5 23 AWG .146 3.71

Style 20063

CM 1000 304.8 78.0 35.4

(solid)

(300V 80°C)

CEC: 2000 609.6 152.0 69.0

.023″

CM

BCCS 50.0Ω/M′ 164.0Ω/km

1 .6 2.0

BC Braid .238 6.05 75 66% 20.5 67.3

10 1.1 3.6

95% Shield x

x

50 2.4 7.9

Coverage .478 12.14

100 3.4 11.2

2.6Ω/M′

200 4.9 16.1

8.5Ω/km

400 7.0 23.0

For Plenum version of see 89555.

700 9.7 31.8 900 11.1 36.4 1000 12.0 39.4

75 Ohm • Dual RG-59/U Type • 23 AWG Solid .023″ Bare Copper-covered Steel Conductors • Bare Copper Braid Shield (97% Coverage) Plenum • FEP Insulation • Clear FEP Jacket 89555 200°C

NEC: 500 152.4 46.5 21.1 23 AWG .134 3.40

CMP 1000 304.8 90.0 40.9

(solid)

CEC:

.023″

CMP FT6

BCCS 50.0Ω/M′ 164.0Ω/km

Suitable for Outdoor and Direct Burial applications.

1 .5 1.6

BC Braid .212 5.39 75 70% 19.5 64.0

10 1.1 3.6

97% Shield x

x

50 2.5 8.2

Coverage .424 10.77

100 3.5 11.5

2.6Ω/M′

200 5.1 16.7 400 7.5 24.6

8.5Ω/km

700 10.4 34.1 900 12.0 39.4 1000 12.7 41.7

75 Ohm • RG-6/U Type • 18 AWG Solid Bare Copper-covered Steel Conductor • Duobond® IV Quad Shield (100% Coverage) Non-Plenum • Gas-injected Foam Polyethylene Insulation • Gray PVC Jacket

1000 304.8 39.0 17.7 18 AWG .180 4.57 Duobond IV\* .300

3131A NEC: 2500†† 762.2 97.5 44.3 (solid) CL2R, CMR

.040″

CEC:

BCCS

CMR FT4

28.0Ω/M′ 91.9Ω/km

Plenum • Foam FEP Insulation • Gray Fluorocopolymer Jacket

1 .35 1.15

7.62 75 82% 16.2 53.2

2 .38 1.25

Quad Shield

5 .45 1.48

3.6Ω/M′

10 .59 1.94

11.8Ω/km

20 .86 2.82

Sweep tested 5 MHz to 400 MHz.

50 1.37 4.50

CPE jacket optional.

100 1.97 6.46 200 2.82 9.25 300 3.48 11.42 400 4.04 13.26

1000 304.8 36.0 16.4 18 AWG .170 4.32 Duobond IV\* .274

1 .36 1.18

3132A 150°C

NEC:

6.96 75 82% 16.3 53.5

2 .38 1.25

CMP

(solid)

Quad Shield

5 .50 1.64

CEC:

7.2Ω/M′

.040″

10 .65 2.13

CMP FT6

BCCS

23.6Ω/km

20 .95 3.12

For Non-plenum version see 3131A.

50 1.50 4.92

28.0Ω/M′

Sweep tested 5 MHz to 400 MHz.

100 2.12 6.96

19.9Ω/km

200 2.99 9.81 300 3.66 12.01

Suitable for Outdoor and Direct Burial applications.

400 4.23 13.88

75 Ohm • RG-11/U Type • 14 AWG Solid Bare Copper-covered Steel Conductor • Duobond IV Quad Shield (100% Coverage) Non-Plenum • Gas-injected Foam Polyethylene Insulation • Gray PVC Jacket

500 152.4 34.5 15.7 14 AWG .280 7.11 Duobond IV\* .407

3094A NEC: CL2R, 1000 304.8 69.0 31.3 (solid) CMR 2000 609.6 136.0 61.7

.064″

CEC:

BCCS

CMG FT4

11.0Ω/M′ 36.1Ω/km

Tap marks every 2.6 meters to aid users in installation.

1 .16 .53

10.34 75 82% 16.2 53.2

2 .18 .59

Quad Shield

5 .26 .85

1.5Ω/M′

10 .38 1.25 20 .55 1.81

4.9Ω/km Sweep tested 5 MHz to 400 MHz.

50 .83 2.72

CPE jacket optional.

100 1.17 3.84 200 1.60 5.25 300 1.99 6.53 400 2.30 7.55

BC = Bare Copper • BCCS = Bare Copper-covered Steel • DCR = DC Resistance • FEP = Fluorinated Ethylene Propylene • SPC = Silver-coated Copper • SPCCS = Silver-coated Copper-covered Steel • TFE = Tetra Fluoroethylene Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1.

\* Duobond IV = Bonded Duofoil® (100% coverage) + aluminum braid (67% coverage) + Duofoil (100% coverage) + aluminum braid (46% coverage). † May contain more than one piece, minimum length of any one piece is 25 ft. †† Spools may contain more than one piece. Final put-up may vary ±10% for spools and reels and ±5% for UnReel® cartons. 25 feet minimum length.

Teflon is a DuPont trademark.

Page 5

6.85

75 Ohm and 93 Ohm Coax

UL NEC/ C(UL) CEC Type Standard Lengths Standard Unit Weight Conductor (stranding) Diameter Nom. DCR Nominal Core OD Shielding Materials Nom. DCR Nominal OD Nom. Imp. (Ω) Nom. Vel. of Prop. Nominal Capacitance Nominal Attenuation
Ft. m Lbs. kg Inch mm Inch mm pF/Ft. pF/m MHz dB/ 100 Ft. dB/ 100m

Part

Description

No.

75 Ohm • RG-11/U Type • 14 AWG Solid Bare Copper-covered Steel Conductor • Duobond IV Quad Shield (100% Coverage) Plenum • Foam FEP Insulation • Gray Fluorocopolymer Jacket 3095A 150°C

NEC: 1000 304.8 76.0 34.5 14 AWG CMP,

(solid)

PLTC

.064″

CEC:

BCCS

CMP FT6

11.0Ω/M′ 36.1Ω/km

Suitable for Outdoor and Direct Burial applications. Tap marks every 2.6 meters to aid users in installation.

1 .20 .70

.280 7.11 Duobond IV\* .387 9.83 75 82% 16.5 54.1

10 .39 1.30

Quad Shield

50 1.20 3.90

3.9Ω/M′

100 1.70 5.60

12.8Ω/km Sweep tested 5 MHz to 400 MHz.

200 2.50 8.20 400 3.50 11.50

93 Ohm • RG-62B/U Type • 24 AWG Stranded (7x32) .024″ Bare Copper-covered Steel Conductor • BC Braid Shield (95% Coverage) Semi-solid Polyethylene Insulation • Black Non-contaminating PVC Jacket 8255 UL AWM

NEC: 500 152.4 16.5 7.5 24 AWG

Style 1354

CMX 1000 304.8 36.0 16.3

(7x32)

(30V 60°C)

CEC:

.024″

VW-1

CMX

BCCS 59.0Ω/M′ 193.6Ω/km

MIL-C-17D

1 .3 1.0

.146 3.71 BC Braid .242 6.15 93 84% 13.5 44.3

10 .9 3.0

95% Shield

50 2.0 6.6

Coverage

100 2.9 9.5

2.9Ω/M′

200 4.2 13.8

9.5Ω/km

400 6.1 20.0 700 8.6 28.2 900 10.1 33.1 1000 11.1 36.4

93 Ohm • RG-62/U Type • JAN-C-17A • 22 AWG Solid .025″ Bare Copper-covered Steel Conductor • BC Braid Shield (95% Coverage) Semi-solid Polyethylene Insulation • Black PVC Jacket 8254 75°C

— U-500 U-152.4 18.0 8.2 22 AWG 500 152.4 16.5 7.5

(solid)

U-1000 U-304.8 35.0 15.9

.025″

1000 304.8 36.0 16.3

BCCS 41.2Ω/M′ 135.1Ω/km

1 .3 .8

.146 3.71 BC Braid .238 6.05 93 84% 13.5 44.3

10 .9 2.8

95% Shield

50 1.9 6.2

Coverage

100 2.7 8.9

2.9Ω/M′

200 3.8 12.5

9.5Ω/km

400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5

93 Ohm • RG-62A/U Type • 22 AWG Solid .025″ Bare Copper-covered Steel Conductor • Bare Copper Braid Shield (95% Coverage) Semi-solid Polyethylene Insulation • Black High-density Polyethylene Jacket Flooded Burial 9228

— 500 152.4 15.0 6.8 22 AWG

80°C

1000 304.8 33.0 15.0

(solid)

2000 609.6 68.0 30.9

.025″

5000 1524.0 170.0 77.3

BCCS 41.2Ω/M′ 135.1Ω/km

Suitable for Outdoor and Direct Burial applications. Semi-solid Polyethylene Insulation • Black PVC Jacket 9268 UL AWM

NEC: 500 152.4 20.0 9.1 22 AWG

Style 1478

CM CL2 U-1000 U-304.8 42.0 19.1

(solid)

(30V 60°C)

CEC: 1000 304.8 44.0 20.0

.025″

CM 2000 609.6 88.0 40.0

BCCS 41.2Ω/M′ 135.1Ω/km

IBM P/N 5252750 • Includes Mylar® tape as a moisture barrier for improved outdoor reliability. 9269 UL AWM

NEC: U-500 U-152.4 18.5 8.4 22 AWG

Style 1478

CM CL2 500 152.4 17.0 7.7

(solid)

CEC: U-1000 ▲ U-304.8 36.0 16.7

.025″

(30V 60°C)

CM 1000 304.8 38.0 17.2

BCCS

1640 500.0 60.7 27.5 41.2Ω/M′ 2000 609.6 76.0 34.5 135.1Ω/km 3280 1000.0 121.4 55.0 5000 1524.0 185.0 84.0

IBM P/N 323921 P-MSHA SC-1823\*\* ▲U-1000 put-up also available in Orange, Beige or Chrome.

1 .3 .8

.146 3.71 BC Braid .242 6.15 93 84% 13.5 44.3

10 .9 2.8

95% Shield

50 1.9 6.2

Coverage

100 2.7 8.9

2.9Ω/M′

200 3.8 12.5

9.5Ω/km

400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5

1 .3 .8

.146 3.71 BC Braid .260 6.60 93 84% 13.5 44.3

10 .9 2.8

95% Shield

50 1.9 6.2

Coverage

100 2.7 8.9

2.9Ω/M′

200 3.8 12.5

9.5Ω/km

400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5 1 .3 .8

.146 3.71 BC Braid .239 6.07 93 84% 13.5 44.3

10 .9 2.8

95% Shield

50 1.9 6.2

Coverage

100 2.7 8.9

2.9Ω/M′

200 3.8 12.5

9.5Ω/km For Plenum version of 9269,

400 5.3 17.4 700 7.3 23.9

see 89269, 87269 and 82269.

900 8.2 26.9 1000 8.7 28.5

BC = Bare Copper • BCCS = Bare Copper-covered Steel • DCR = DC Resistance • FEP = Fluorinated Ethylene Propylene

Mylar is a DuPont trademark.

Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. For cables manufactured to latest government revision or other MIL-SPEC requirements, please contact your nearest Belden regional Sales Office.

\* Duobond IV = Bonded Duofoil® (100% coverage) + aluminum braid (67% coverage) + Duofoil (100% coverage) + aluminum braid (46% coverage). \*\* Pennsylvania Department of Environmental Resources and United States Mine Safety and Health Administration Certification.

Page 6

6.86

93 Ohm Coax

UL NEC/ C(UL) CEC Type Standard Lengths Standard Unit Weight Conductor (stranding) Diameter Nom. DCR Nominal Core OD Shielding Materials Nom. DCR Nominal OD Nom. Imp. (Ω) Nom. Vel. of Prop. Nominal Capacitance Nominal Attenuation
Ft. m Lbs. kg Inch mm Inch mm pF/Ft. pF/m MHz dB/ 100 Ft. dB/ 100m

Part

Description

No.

RG-62/U Type • 22 AWG Solid .025″ Bare Copper-covered Steel Conductor • Bare Copper Braid Shield (94% Coverage) Plenum • Semi-solid FEP Teflon® Insulation • Black or White Tint FEP Jacket 89269 200°C

NEC: 100 ▲ 30.5 5.2 2.4 22 AWG .142 3.61 CMP 500 152.4 16.5 7.5

(solid)

CEC: 1000 304.8 33.0 15.0

.025″

CMP FT6

BCCS 41.2Ω/M′ 135.2Ω/km

▲100 ft. put-up available in Black only. Suitable for Outdoor and Direct Burial applications.

1 .3 1.0

BC Braid .200 5.08 93 85% 12.8 42.0

10 .9 3.0

94% Shield

50 1.9 6.2

Coverage

100 2.7 8.9

3.4Ω/M′

200 3.8 12.5

11.2Ω/km

400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5

Plenum • Semi-solid FEP Teflon Insulation • Gray Fluorocopolymer Jacket 87269 150°C

NEC: 1000 304.8 34.0 15.4 22 AWG .142 3.61

CMP

(solid)

CEC:

.025″

CMP FT6

BCCS 41.2Ω/M′ 135.2Ω/km

Suitable for Outdoor and Direct Burial applications.

1 .3 1.0

BC Braid .200 5.08 93 85% 12.8 42.0

10 .9 3.0

94% Shield

50 1.9 6.2

Coverage

100 2.7 8.9

3.4Ω/M′

200 3.8 12.5

11.2Ω/km

400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5

Plenum • Semi-solid FEP Teflon Insulation • Natural Flamarrest® Low-smoke Jacket 82269 75°C

NEC: 1000 304.8 30.0 13.6 22 AWG .142 3.61

CMP

(solid)

CEC:

.025″

CMP FT6

BCCS 41.2Ω/M′ 135.2Ω/km

Plenum • Foam FEP Teflon Insulation • White Tint FEP Jacket 86262 200°C

NEC: 500 152.4 16.0 7.3 22 AWG .146 3.71

CMP 1000 304.8 32.0 14.5

(solid)

CEC:

.025″

CMP FT6

BCCS 41.2Ω/M′ 135.2Ω/km

Suitable for Outdoor and Direct Burial applications. Plenum • Foam FEP Teflon Insulation • Natural Flamarrest Jacket 82262 75°C

NEC: U-1000 U-304.8 31.0 14.1 22 AWG .146 3.71 CMP 1000 304.8 30.0 13.6

(solid)

CEC:

.025″

CMP FT6

BCCS 41.2Ω/M′ 135.2Ω/km

BC = Bare Copper • BCCS = Bare Copper-covered Steel • DCR = DC Resistance • FEP = Fluorinated Ethylene Propylene Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1.

Teflon is a DuPont trademark.

1 .3 1.0

BC Braid .200 5.08 93 85% 12.8 42.0

10 .9 3.0

94% Shield

50 1.9 6.2

Coverage

100 2.7 8.9

3.4Ω/M′

200 3.8 12.5

11.2Ω/km

400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5

1 .3 1.8

BC Braid .204 5.18 93 85% 12.5 41.0

10 .9 3.0

94% Shield

50 1.9 6.2

Coverage

100 2.7 8.9

3.4Ω/M′

200 3.8 12.5

11.2Ω/km

400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5

1 .3 1.8

BC Braid .204 5.18 93 85% 12.5 41.0

10 .9 3.0

94% Shield

50 1.9 6.2

Coverage

100 2.7 8.9

3.4Ω/M′

200 3.8 12.5

11.2Ω/km

400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5

Page 7

6.87

78 Ohm, 95 Ohm and 100 Ohm Twinax

UL NEC/ C(UL) CEC Type Standard Lengths Standard Unit Weight Conductor (stranding) Diameter Nom. DCR Nominal Core OD Shielding Materials Nom. DCR Nominal OD Nom. Imp. (Ω) Nom. Vel. of Prop. Nominal Capacitance Nominal Attenuation
Ft. m Lbs. kg Inch mm Inch mm pF/Ft. pF/m MHz dB/ 100 Ft. dB/ 100m

Part

Description

No.

78 Ohm • 20 AWG Stranded (7x28) .038″ Tinned Copper Conductors • Tinned Copper Braid Shield (93% Coverage) Polyethylene Insulation • Blue PVC Jacket (Color Code: Clear, Blue) 9272 UL AWM

NEC: 100 30.5 4.5 2.0 20 AWG

Style 2092

CM U-500 U-152.4 20.0 9.1

(7x28)

(300V 60°C)

CEC: 500 152.4 18.5 8.4

.038″

CM U-1000 U-304.8 39.0 17.7

TC

1000 304.8 41.0 18.6 9.5Ω/M′

31.2Ω/km

1 .6 2.0

.156 3.96 TC Braid .244 6.20 78 66% 19.7 64.6

10 2.1 6.9

93% Shield

50 5.0 16.4

Coverage

For Plenum version of 9272,

100 7.5 24.6

3.4Ω/M′

see 89272.

200 11.0 36.1

11.2Ω/km

400 16.0 52.5

CPE jacket optional.

Plenum • FEP Teflon® Insulation • Blue FEP Teflon Jacket (Color Code: Clear, Blue) 89272 200°C

NEC: 500 152.4 17.0 7.7 20 AWG CMP 1000 304.8 38.0 17.3

(7x28)

CEC:

.038″

CMP FT6

TC 9.5Ω/M′ 31.2Ω/km

Suitable for Aerial applications when supported by a messenger.

1 .6 2.0

.148 3.76 TC Braid .198 5.03 78 69.5% 18.4 60.4

10 2.1 6.9

93% Shield

50 5.0 16.4

Coverage

100 7.5 24.6

3.9Ω/M′

200 11.0 36.1

12.8v/km

400 16.0 52.5

78 Ohm • 20 AWG Stranded (7x28) .038″ Tinned Copper Conductors • Beldfoil® (100% Coverage) + TC Braid Shield (55% Coverage) Polyethylene Insulation • Blue Sunlight-resistant PVC Jacket (Color Code: Clear, Blue) 9463 UL AWM

NEC: 100 30.5 4.4 2.0 20 AWG

Style 2464

CM CL2 U-500 U-152.4 19.5 8.9

(7x28)

(300V 80°C)

CEC: 500 152.4 18.0 8.2

.038″

CM U-1000 U-304.8 38.0 17.2

TC

1000 ▲ 304.8 39.0 17.7 9.5Ω/M′ 6000 ▲† 1828.7 234.0 106.1 31.0Ω/km 10000 ▲† 3048.0 380.0 172.4

PMSHA P-7K-SC-182141\* Allen Bradley P/N 1770-CD

1 .6 2.0

.154 3.91 Beldfoil .238 6.05 78 66% 19.7 64.6

10 2.1 6.9

+ 55% TC

50 3.6 11.8

Braid

100 7.5 24.6

4.1Ω/M′

200 11.0 36.1

13.4Ω/km

400 16.0 52.5

CPE jacket optional.

▲1000 ft. and 6000 ft. put-ups also available in Brown, Orange and Purple. 10,000 ft. available in Brown or Orange only.

RG-22B/U • 95 Ohm • 18 AWG Stranded (7x26) .046″ Bare Copper Conductors\*\* • Double Tinned Copper Braid Shield (95% Coverage) Polyethylene Insulation • PE Inner Jacket • Black Non-contaminating PVC Outer Jacket (Color Code: Clear, Clear) 9250 80°C

— 500 152.4 61.5 27.9 18 AWG

VW-1

1000 304.8 121.0 54.9

(7x26) .046″ BC 6.6Ω/M′ 21.5Ω/km

RG-22B/U Type \*\*1 conductor has tinned center strand. Non-contaminating PVC jacket.

1 .3 1.0

.285 7.24 (2) TC Braids .416 10.67 95 66% 16.0 52.5

10 .9 3.0

95% Shield

20 1.3 4.3

Coverage

50 2.1 6.9

.9Ω/M′

100 3.0 9.8

3.0Ω/km

400 6.3 20.7

CPE jacket optional.

100 Ohm • 20 AWG Stranded (7x28) .037″ One Tinned/One Bare Copper Conductors • Duofoil® + Double TC Braid Shield (95% Coverage) Polyethylene Insulation • Black High-density Polyethylene Jacket Direct Burial 9815

— 500 152.4 34.5 15.7 20 AWG

80°C

1000 304.8 69.0 31.4

(7x28)

2000 609.6 134.0 60.9

.037″ (1) TC, (1) BC 9.5Ω/M′ 31.0Ω/km

1 .4 1.3

.236 5.99 TC Braid .330 8.38 100 66% 14.5 47.6

10 1.1 3.6

95% Shield

50 2.5 8.2

Coverage

100 4.1 13.5

2.0Ω/M′

200 6.4 21.0

6.6Ω/km

400 10.2 33.5

BC = Bare Copper • DCR = DC Resistance • FEP = Fluorinated Ethylene Propylene • PE = Polyethylene • TC = Tinned Copper Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. \*Pennsylvania Department of Environmental Resources and United States Mine Safety and Health Administration Certification. †Final put-up may vary from length shown. ±10% for spools or reels, ±5% for UnReel® cartons.

Teflon is a DuPont trademark.

Page 8

6.88

100 Ohm, 124 Ohm and 150 Ohm Twinax

Standard Lengths Standard Unit Weight Conductor (stranding) Diameter Nom. DCR Nominal Core OD Shielding Materials Nom. DCR Nominal OD Nom. Imp. (Ω) Nom. Vel. of Prop. Nominal Capacitance Nominal Attenuation
Ft. m Lbs. kg Inch mm Inch mm pF/Ft. pF/m MHz dB/ 100 Ft. dB/ 100m

UL NEC/

Part

Description

C(UL) CEC

No. Type

100 Ohm • 20 AWG Stranded (7x28) .037″ One TC/One BC Conductor • Duofoil® (100% Coverage) + TC Braid Shield (86% Coverage) Polyethylene Insulation • Polyethylene Inner Jacket • Black PVC Outer Jacket 9207 75°C

NEC: 100 30.5 7.1 3.2 20 AWG .236 5.99

CM CL2 U-500 U-152.4 33.0 15.0

(7x28)

CEC: 500 152.4 34.5 15.7

.037″

CMG FT4 1000 304.8 68.0 30.9

(1) TC,

1640 500.0 111.5 50.7

(1) BC

2000 609.6 136.0 61.8 9.5Ω/M′ 3280 1000.0 219.8 99.9 31.0Ω/km

IBM P/N 7362211

5000 1524.0 350.0 159.1

1 .3 1.0

Duofoil .330 8.38 100 66% 14.5 47.6

10 1.2 3.9

+86%

50 2.8 9.2

TC Braid

100 4.1 13.5

1.7Ω/M′

For Plenum versions see 89207.

200 6.4 21.0

5.7Ω/km

400 10.2 33.5

CPE jacket optional.

100 Ohm • 20 AWG Stranded (7x28) .037″ One TC/One BC Conductor • Duofoil (100% Coverage) + TC Braid Shield (85% Coverage) Plenum • FEP Insulation • Black FEP Jacket 89207 200°C

NEC: 100 30.5 6.7 3.0 20 AWG .201 5.11

CMP 500 152.4 26.0 11.8

(7x28)

CEC: 1000 304.8 55.0 25.0

.037″

CMP FT6

(1) TC, (1) BC 9.5Ω/M′ 31.2Ω/km

1 .3 1.0

Duofoil .259 6.58 100 69.5% 14.0 46.0

10 1.2 3.9

+85%

50 2.8 9.2

TC Braid

100 4.1 13.5

2.5Ω/M′

200 6.4 21.0

8.2Ω/km

300 8.4 27.6 400 10.2 33.5

124 Ohm • 25 AWG Stranded (7x33) .021″ Tinned Copper Conductors • Beldfoil® Shield (100% Coverage) • Stranded TC Drain Wire Polyethylene Insulation • Blue PVC Jacket (Color Code: Clear, Blue) 9271 UL AWM

NEC: 100 30.5 3.2 1.5 25 AWG .170 4.32

Style 2092

CM 500 152.4 12.5 5.7

(7x33)

(300V 60°C)

CEC: U-1000 U-304.8 27.0 12.3

.021″

CM 1000 304.8 28.0 12.7

TC 31.8Ω/M′ 104.3Ω/km

Shorting Fold

1 .6 2.0

Beldfoil .240 6.10 124 66% 12.2 40.0

10 1.7 5.6

12.0Ω/M′

50 3.6 11.8

39.4Ω/km

100 5.0 16.4 200 6.9 22.6

CPE jacket optional.

400 9.6 31.5

124 Ohm • 16 AWG Solid .051″ Bare Copper Conductors • Duofoil (100% Coverage) + Tinned Copper Braid Shield (90% Coverage) Foam Polyethylene Insulation • Black PVC Jacket (Color Code: Clear, Blue) 9860 UL AWM

NEC: 500 152.4 52.0 23.6 16 AWG .322 8.18

Style 2448

CMX 1000 304.8 103.0 46.8

(solid)

(30V 60°C)

CEC: 2000 609.6 202.0 91.8

.051″

VW-1

CMX

BC 4.2Ω/M′ 13.8Ω/km

1 .2 .6

Duofoil .440 11.18 124 78% 10.9 35.8

10 .7 2.3

+ 90%

50 1.8 5.9

TC Braid

100 2.9 9.5

1.3Ω/M′

CPE jacket optional.

200 4.1 13.5

4.3Ω/km

400 6.2 20.3

150 Ohm • 22 AWG Stranded (19x34) .031″ Tinned Copper Conductors • Duofoil Shield (100% Coverage) • Stranded TC Drain Wire Datalene® Insulation • Black PVC Jacket (Color Code: Black, Yellow) 9182 UL AWM

NEC: U-500 U-152.4 21.5 9.8 22 AWG .275 6.98

Style 2668

CMX 500 152.4 23.0 10.4 (19x34)

(30V 60°C)

CL2X 1000 304.8 44.0 20.0

.031″

VW-1

CEC:

TC

CMX

14.0Ω/M′ 45.9Ω/km

Shorting Fold

1 .4 1.3

Duofoil .345 8.76 150 78% 8.8 28.9

10 1.2 3.9

6.3Ω/M′

50 2.7 8.7

20.7Ω/km

For Plenum version of 9182,

100 4.3 14.1 200 6.2 20.3

see 89182.

400 8.8 28.9

Dual version: YR41609. CPE jacket optional.

Plenum • Foam FEP Teflon Insulation • Black FEP Teflon Jacket (Color Code: Black, Yellow)

1 .4 1.3

89182 NEC: 100 30.5 6.4 2.9 22 AWG .278 7.06

Duofoil .307 7.80 150 78% 8.8 28.9

10 1.2 3.9

CMP 500 152.4 28.0 12.7 (19x34)

6.3Ω/M′

50 2.7 8.7

CL2P 1000 304.8 53.0 24.1

.031″

20.7Ω/km

100 4.3 14.1

CEC:

TC

200 6.2 20.3

CMP FT6

14.0Ω/M′

400 8.8 28.9

45.9Ω/km

BC = Bare Copper • DCR = DC Resistance • FEP = Fluorinated Ethylene Propylene • TC = Tinned Copper Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1.

Teflon is a DuPont trademark.

Page 9

Electrical Characteristics — Twinax

Attenuation

PDF page 9 diagram

9859, 9272, 9463

Frequency (MHz)

Bit Rate

PDF page 9 diagram

Bit Rate (Megabits/Sec.)

6.89

Rise Time

PDF page 9 diagram

0 to 50% Rise Time (Microseconds)

Transfer Impedance

PDF page 9 diagram

.1

1.0

10.0

50.0

Frequency (MHz)

Page 10

6.90

50 Ohm Triax

UL NEC/ C(UL) CEC Type Standard Lengths Standard Unit Weight Conductor (stranding) Diameter Nom. DCR Nominal Core OD Shielding Materials Nom. DCR Nominal OD Nom. Imp. (Ω) Nom. Vel. of Prop. Nominal Capacitance Nominal Attenuation
Ft. m Lbs. kg Inch mm Inch mm pF/Ft. pF/m MHz dB/ 100 Ft. dB/ 100m

Part

Description

No.

RG-58A/U Type • 20 AWG Stranded (7x28) .037″ Tinned Copper Conductor • Double Tinned Copper Braid Shield (96% Coverage) Polyethylene Insulation • Yellow PVC Jacket (Polyethylene Insulation between Braids) 9222 75°C

— 100 30.5 4.6 2.1 20 AWG .114 2.90

U-500 U-152.4 19.5 8.8

(7x28)

500 152.4 20.5 9.3

.037″ TC 9.5Ω/M′ 31.0Ω/km

1 .5 1.6

(2) TC Braids .240 6.10 50 66% 30.8 101.0

10 1.5 4.9

96% Shield

50 3.3 10.8

Coverage

100 4.9 16.1

Inner:

200 7.2 23.6

4.7Ω/M′

400 12.0 39.4

15.5Ω/km

700 18.0 57.1

Outer:

900 22.0 72.2

4.3Ω/M′

1000 24.0 78.7

14.1Ω/km

RG-8/U Type • 11 AWG Stranded (7x19) .108″ Bare Copper Conductor • Double Bare Copper Braid Shield (96% Coverage) Foam Polyethylene Insulation • Black Polyethylene Jacket (Polyethylene Insulation between Braids) 9888 80°C

— 500 152.4 72.5 33.0 11 AWG .285 7.24 1000 304.8 140.0 63.6

(7x19) .108″ BC 1.2Ω/M′ 3.9Ω/km

BC = Bare Copper • DCR = DC Resistance • TC = Tinned Copper Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1.

1 .1 .5

(2) BC .480 12.19 50 78% 26.0 85.3

10 .5 1.7

96% Shield

50 1.2 3.9

Coverage

100 1.8 5.9

Inner:

200 2.7 8.9

1.2Ω/M′

400 4.2 13.8

3.9Ω/km

700 5.8 19.0

Outer:

900 6.7 22.0

2.1Ω/M′

1000 7.1 23.3

4.9Ω/km