9791 BELDEN
Document overview
- PDF pages: 2
Technical content
Page 1

Product: 9791
RS232/423 Low Cap, #28-6c, FPO, O/A Foil+Braid, PVC Jkt, CL2
Product Description
Computer EIA RS-232/423 Cable, 28 AWG stranded (7x36) tinned copper conductors, Datalene® insulation, overall Beldfoil® (100% Coverage) + tinned
copper braid shield (65% Coverage), 28 AWG stranded tinned copper drain wire, PVC jacket.
Technical Specifications
Product Overview
rs-232 extended distance applications; rs-423 applications; computer communications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line
Suitable Applications:
level audio; panel wiring
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
| Conductor(s) | 6 | 28 AWG | 7x36 | TC - Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
| Conductor(s) | PE - Polyethylene (Foam | ) 0.015 in (0.38 mm) | 0.044 in (1.1 mm) | Black, White, Red, Green, Brown, Blue |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 28 AWG (7x36) TC |
| Braid | Tinned Copper (TC) | 65% |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter | Ripcord | |
| PVC - Polyvinyl Chloride | 0.035 in (0.89 mm) | 0.225 in | Yes | |
| Overall Cable Diameter 0.225 in (Nominal): | ||||
Electrical Characteristics
Electricals
| Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
|---|---|---|---|---|---|
| 72.8 Ohm/1000ft | 12 pF/ft (39 pF/m) | 22 pF/ft (72 pF/m) | 100 Ohm | 78% | 2.1 Amps per Conductor at 25ºC |
Voltage
UL Voltage Rating
300 V (CL2), 30 V AC (UL AWM 2919)
Mechanical Characteristics
Temperature
UL Temperature Operating
80°C
-30°C To +80°C
Page 2
Bend Radius
| Stationary Min. | Installation Min. | |
|---|---|---|
| 2.25 in (57.2 mm) | 2.25 in | |
| Max. Pull Tension: 14.7 lbs (6.67 kg) | ||
| Bulk Cable Weight: 26 lbs/1000ft | ||
Standards and Compliance
Environmental Suitability:
Indoor
Flammability / Reaction to Fire: UL 1685 UL Loading
NEC / UL Compliance:
Article 725, CL2
AWM Compliance:
AWM 2919
European Directive
EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
Compliance:
APAC Compliance:
China RoHS II (GB/T 26572-2011)
Product Notes
Datalene® insulation features include a low dielectric constant and a low dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush
Notes:
resistance and light weight.
History
Update and Revision:
Revision Number: 0.403 Revision Date: 05-05-2023
Part Numbers
Variants
| Item # | Color | Putup Type | Length | UPC |
|---|---|---|---|---|
| 9791 060500 | Chrome | Reel | 500 ft | 612825258674 |
| 9791 0601000 | Chrome | Reel | 1,000 ft | 612825258667 |
© 2023 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product