General Description:

18 AWG stranded (19x30) TC conductors, polypropylene insulation, twisted pairs, individually shielded

w/Beldfoil® (100% coverage), 20 AWG stranded TC drain wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 3 18 19x30 TC - Tinned Copper Total Number of Conductors: 6 Insulation Insulation Material: Insulation Material Wall Thickness (mm) PP - Polypropylene 0.483 Inner Shield Inner Shield Material: Inner Shield Trade Name Type Inner Shield Material Coverage (%) Beldfoil® (Z-Fold®) Tape Aluminum Foil-Polyester Tape 100 Inner Shield Drain Wire AWG: AWG Inner Shield Drain Wire Stranding: Stranded Inner Shield Drain Wire Conductor Material: TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 0.889 Overall Cable Overall Nominal Diameter: 10.262 mm Pair Pair Color Code Chart: Number Color

1 Black & Red

2 Black & White

3 Black & Green

Mechanical Characteristics (Overall) Operating Temperature Range: -20°C To +80°C UL Temperature Rating: 80°C (UL AWM Style 2919) Bulk Cable Weight: 125.009 Kg/Km Max. Recommended Pulling Tension: 787.331 N Min. Bend Radius/Minor Axis: 107.950 mm Page 1 of 3 08-21-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION

9773 Multi-Conductor - Audio, Control and Instrumentation Cable

Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CM NEC Articles: 800 CEC/C(UL) Specification: CM AWM Specification: UL Style 2919 (30 V 80°C) EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 UL Loading CSA Flame Test: FT1 Suitability Suitability - Indoor: Yes Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) Nom. Inductance: Inductance (µH/m) 0.59058 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 98.43 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 180.455 Nominal Velocity of Propagation: VP (%) Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/km) 20.9984 Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C:

27.232 Ohm/km

Max. Operating Voltage - UL: Voltage Description

30 V RMS AWM Style 2919

300 V RMS CM

Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION

Max. Recommended Current: Description Current 10C Temperature Rise 3.6 Amps per conductor @ 25°C ambient Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc 9773 060100 30 MT 4.264 KG CHROME 3 FS PR #18 PP PVC 9773 0601000 305 MT 42.184 KG CHROME C 3 FS PR #18 PP PVC 9773 060500 152 MT 20.639 KG CHROME C 3 FS PR #18 PP PVC 9773 0605000 1,524 MT 219.993 KG CHROME C 3 FS PR #18 PP PVC Notes: C = CRATE REEL PUT-UP. Revision Number: 3 Revision Date: 08-05-2013 © 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 08-21-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION