motor starters. For a new start! Accurate and reliable control of motors TeSys TeSys range provide you more simplicity, compactness, openness and flexibility ... so many evolutions and new items to aid your productivity. New horizons are opening up to you. Increase your productivity - adopt our solutions which help to simplify setting-up. A range of simple, compact and advanced components for power control and protection. Motor starters b Ready-to-use component combinations, designed to work together in perfect harmony. b Safe operation and level of coordination guaranteed by a major manufacturer. Power circuit control b A wide range of components. b Solutions for a variety of power control applications: lighting, capacitor switching, heating, changeover contactor pairs, resistive loads, upstream protection.

Control increases in power Simply Smart benefits Introducing the 1st intelligent starter capable of integrating motor control, control and changeover functions in a unit 45 mm wide! Simple in its modular format, it is also open to standard buses and can monitor your applications via the web.

Applications

bbbbb Industry: ideal solution when the motor starter needs to be decentralized in the machine or the process

Contents

b Contactors, models K, D, F b Manual motor starters b Switch-disconnector-fuses b Thermal overload relays b Electronic thermal overload relays b Multifunction protection relays b Switch disconnectors Mini Vario and Vario b Self-protected starter, U-Line b Solid state overload relay system, U-Line b TeSys type CA2K, CA3K and CA4K b TeSys type CAD b Contactors and starters b Combination starters b Solid state overload relays Motor Logic® b Definite purpose contactors b Lighting contactors b Manual starters and switches b Accessories b Industrial control relays b Circuit breaker operating mechanisms b Disconnect switches

For other versions, please consult with your localSchneider Electric / Square D sales office: visit www.us.telemanique.com.5/2 Connections ■ screw clamp terminals Rated operational current Ie max AC-3 (Ue - 440V) 6 A 9 A 12 A Ie AC-1 (θ - 40° C) - 20 A - Rated operational power 220/240 V 2 Hp 3 Hp 4 Hp in category AC3 380/400 V–415/440 V 3 Hp 5 Hp 7.5 Hp 660/690 V–500 V 4 Hp 5 Hp 5 Hp Contactor type (1)(2) AC LC1K06• LC1K09 LC1K12 DC LP1K06 or LP4K06 LP1K09 or LP4K09 LP1K12 or LP4K12 Reversing contactor type (2) AC LC2K06 LC2K09 LC2K12 with mechanical interlock DC LP2K06 or LP5K06 LP2K09 or LP5K09 LP2K12 or LP5K12 ■ spring terminals Add the figure 3 before the voltage code. Example LC1K0610 becomes LC1K06103 ■ slip-on connectors, 1 x 6.35 or 2 x 2.8 Add the figure 7 before the voltage code. Example LC1K0610 becomes LC1K06107 ■ solder pins for printed circuit boards Add the figure 5 before the voltage code. Example LC1K0610 becomes LC1K06105 (2) Basic catalog number to be completed by adding the coil voltage. Example (including auxiliary contact) LC1RO601G7. Standard control circuit voltages AC supply Contactors LC1K (0.8–1.15 Uc) (0.85–1.1UC) Volts 12 20 24 36 42 48 110 115 120 127 200/208 220/230 230 230/240 50/60 Hz J7 Z7 B7 C7 D7 E7 F7 FE7 G7 FC7 L7 M7 P7 U7 Volts 256 277 380/400 400 400/415 440 480 500 575 600 660/690 50/60 Hz W7 UE7 Q7 V7 N7 R7 T7 S7 SC7 X7 Y7 Example of complete catalog number LC1K0910P7. DC supply Contactors LP1K (0.8–1.15 Uc) Volts 12 20 24 36 48 60 72 100 110 125 155 174 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UD Coil with integral suppression device available, add 3 to the code required. Example JD3 Low consumption Contactors LP4K (0.7–1.30 Uc), coil suppression as standard V olts 12 20 24 48 72 110 120 Code JW3 ZW3 BW3 EW3 SW3 FW3 GW3 Example of complete catalog number LC1K0910BD. TeSys K-line Contactors 0.5–10 Hp

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/3 Auxiliary contact blocks ■■■■■ instantaneous, screw clamp connections Catalog number LA1KN20 LA1KN02 LA1KN11 LA1KN40 LA1KN31 LA1KN22 LA1KN13 LA1KN04 ■■■■■ electronic time delay Relay outputs, with common point changeover contact, AC or DC 24–48, 2 A maximum Control voltage 0.85–1.1Uc Maximum switching capacity 250 VA or 150 W Operating temperature -10 to + 60°C Reset time: 1.5 s for 0.5 s after the time delay period T ype On-delay Timing range 1–30 s Composition 1 Voltage AC or DC 24–48 V AC 110–240 Reference LA2KT2E LA2KT2U Suppressor modules For LC1, LP1K T ype Varistor (A C and DC) Diode (DC) + zener RC (AC) Voltage 12–24 V 32–48 V 50–129 V 130–250 V 12–24 V 32–48 V 110–250 V Catalog number LA4KE1B LA4KE1E LA4KE 1FC LA4KE1UG LA4KC1B LA4KC1E LA4KA1U TeSys K-line

For other versions, please consult with your localSchneider Electric / Square D sales office: visit www.us.telemanique.com.5/4 Connections ■■■■■ screw clamp terminals or connectors Rated operational voltage 690 V Rated operational current Ie max AC-3 (Ue - 440V) 9 A 12 A 18 A 25 A 32 A Ie AC-1 (θ - 60° C) 25 A 32 A 40 A 50 A Rated operational power 220/240 V 3 Hp 4 Hp 5 Hp 7.5 Hp 10 Hp in category AC3 380/400 V 5 Hp 7.5 Hp 10 Hp 15 Hp 20 Hp 415/440 V 5 Hp 7.5 Hp 12 Hp 15 Hp 20 Hp 500 V 7.5 Hp 10 Hp 13 Hp 20 Hp 25 Hp 660/690 V 7.5 Hp 10 Hp 13 Hp 20 Hp 25 Hp

1000 V - - - - -

Contactor type (1) LC1D09 LC1D12 LC1D18 LC1D25 LC1D32 Reversing contactor type * with mechanical interlock LC2D09 LC2D12 LC2D18 LC2D25 LC2D32 ■■■■■ spring terminals (1) Add the figure 3 before the voltage code. Example LC1D09P7 becomes LC1093P7 ■■■■■ ring tongue terminals (2) Add the figure 6 before the voltage code. Example LC1D09P7 becomes LC1096P7 ■■■■■ slip-on connectors (3) 2 x 6.35 (power) and 1 x 6.35 (control) up to D12 only Add the figure 9 before the voltage code. Example LC1D09P7 becomes LC1099P7 (1) Basic catalog number to be completed by adding the coil voltage. Example: LC1D09P7. Standard control circuit voltages AC supply Volts 24 42 48 110 115 220 230 240 380 400 415 440 500 Contactors LC1D09–D50 (coils D115 and D150 with integral suppression device fitted as standard) 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 - Contactors LC1D40–D115

50 Hz B5 D5 E5 F5 FE5 M5 P5 U5 Q5 V5 N5 R5 S5

60 Hz B 6 - E 6 F 6- M 6 - U 6Q 6 - - R 6 -

Volts 12 24 36 48 60 72 110 125 220 250 440 Contactors LC1D09–D38 (coils with integral suppression device fitted as standard) U 0.7–1.25 Uc JD BD CD ED ND SD FD GD MD UD RD Contactors LC1D40–D95 U 0.85–1.1 Uc JD BD CD ED ND SD FD GD MD UD RD U 0.75–1.2 Uc J W BW CW EW - SW FW - MW - - Contactors LC1D115 and D150 (coils with integral suppression device fitted as standard) U 0.75–1.2 Uc - BD - ED ND SD FD GD MD UD RD Low consumption Contactors LC1D09–D38 (coils with integral suppression device fitted as standard) Volts DC 5 12 20 24 48 110 120 250 U 0.7–1.25 Uc AL JL ZL BL EL FL ML UL Example of complete catalog number LC1D09P7. For enclosed version of d-Line starters up to 80A, reference catalog 8502CT9901. TeSys D-line Contactors 0.5–125 Hp (1) LC1D093P7 (3) LC1D099P7(2) LC1D096P7

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/5 Mounting accessories for 3-pole reversing contactors 2 identical contactors with screw clamp terminals or connectors, horizontally mounted Mechanical interlock Set of connections M echanical interlock ■■■■■ with an electrical interlocking kit for the contactors LC1D09–D38 LAD9R1V included ■■■■■ with integral electrical interlocking LC1D40–D65 LA9D6569 LA9D4002 LC1D80 and D95 (AC) LA9D8069 LA9D4002 LC1D80 and D95 (DC) LA9D8069 LA9D8002 LC1D115 and D150 LA9D11569 LA9D11502 ■■■■■ without electrical interlocking LC1D09–D38 LA99R1 included LC1D40–D65 LA9D6569 LA9D50978 LC1D80 and D95 (AC) LA9D8069 LA9D50978 LC1D80 and D95 (DC) LA9D8069 LA9D80978 Mechanical latch blocks Clip-on front mounting, manual or electrical unlatching control For use on contactor Catalog number Standard control circuit voltages LC1D40–D65 3P AC or DC, LC1D65 4P AC, LC1D65 4P DC LA6DK10 B E F M Q LC1D80–D150 3P AC, LC1D80 and D115 3P AC, LC1D115 4P DC LA6DK20 B E F M Q LC1D09–D38 AC or DC, LC1DT20–DT40 AC or DC LA66K10 B E F M Q

1000 V on AC supply , 690 V on DC supply

38 A 40 A 50 A 65 A 80 A 95 A 115 A 150 A

60 A 80 A 125 A 200 A

12 Hp 15 Hp 20 Hp 25 Hp 30 Hp 30 Hp 40 Hp 50 Hp

25 Hp 25 Hp 30 Hp 40 Hp 50 Hp 60 Hp 75 Hp 100Hp

25 Hp 30 Hp 30/40 Hp 50 Hp 60 Hp 60 Hp 75 Hp 100 Hp

25 Hp 30 Hp 40 Hp 50 Hp 75 Hp 75 Hp 100 Hp 125Hp

25 Hp 40 Hp 44 Hp 50 Hp 60 Hp 60 Hp 100 Hp 125Hp

  • 30 Hp 40 Hp 50 Hp 60 Hp 60 Hp 100 Hp 125 Hp LC1D38 LC1D40 LC1D50 LC1D65 LC1D80 LC1D95 LC1D115 LC1D150 LC2D38 LC2D40 LC2D50 LC2D65 LC2D80 LC2D95 LC2D115 LC2D150 TeSys D-line

For other versions, please consult with your localSchneider Electric / Square D sales office: visit www.us.telemanique.com.5/6 Maximum number of auxiliary contacts that can be fitted Contactors Instantaneous auxiliary contact blocks Time dela y T ype Number of poles and size Side moun ting Front mounting Front mounting 1 contact 2 contacts 4 contacts AC 3P LC1D09–D38 1 on LH side and - 1 or 1 or 1 LC1D40–D95 (50/60 Hz) 1 on each side or 2 and 1 or 1 or 1 LC1D40–D95 (50 or 60 Hz) 1 on each side and 2 and 1 or 1 or 1 LC1D115 and D150 1 on LH side - and 1 or 1 or 1 4P LC1DT20–DT40 1 on LH side - 1 or 1 or 1 LC1D65 and D80 1 on each side or 1 or 1 or 1 or 1 LC1D115 1 on each side and 1 or 1 or 1 or 1 D C 3P LC1D09–D38 - - 1 or 1 or 1 LC1D40–D95 - 1 or 1 or 1 or 1 LC1D115 and D150 1 on LH side and - 1 or 1 or 1 4P LC1DT20–DT40 - - 1 or 1 or 1 LP1D65 and D80 - 2 and 1 or 1 or 1 LC1D115 1 on each side - and 1 or 1 or 1 Low Consumption 3P LC1D09–D38 --1 -- 4P LC1DT20–DT40 --1 Auxiliary contact blocks ■■■■■ instantaneous, for connection by screw clamp terminals ■■■■■ time delay Composition Catalog number Composition Catalog number Composition Catalog number Composition Catalog number T ype Range Catalog number 1- LADN10 11 LADN11 22 LADN22 11 LAD8N11 On-delay 0.1–3 s LADT0 -1 LADN01 2- LADN20 13 LADN13 2- LAD8N20 0.1–30 s LADT2 -2 LADN02 4- LADN40 -2 LAD8N02 10–180 s LADT4 -4 LADN04 Off-delay 0.1–3 s LADR0 31 LADN31 0.1–30 s LADR2 10–180 s LADR4 TeSys D-line Contactors 0.5–125 Hp

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/7 Suppressor modules Varistors (peak limiting) Protection provided by limiting the transient voltage to 2 Uc max. Maximum reduction of transient voltage peaks. Slight increase in drop-out time (1.1 to 1.5 times the normal time) Mounting For use with contactor T ype Catalog number Rating VAC VDC Clip-on D09–D38 (3P) 12–24 V - LAD4VE DT20–DT40 (4P) 50–127 V - LAD4VG 110–240 V - LAD4VU Screw clamp D40–D115 (3P) 24–48 V - LA4DE2E and 50–127 V - LA4DE2G D65–D115 (4P) 110–250 V - LA4DE2U D40–D115 (3P) - 24–48 V LA4DE3E and - 50–127 V LA4DE3G D65–D115 (4P) - 110–250 V LA4DE3U Diodes No overvoltage or oscillating frequency . Increase in drop-out time (6 to 10 times the normal time). Polarised component. Screw clamp D40–D95 (3P) - 24–250 V LA4DC3U D65 and D80 (4P) Bidirectional peak limiting diode Protection provided by limiting the transient voltage to 2 Uc max. Maximum reduction of transient voltage peaks. Clip-on D09–D38 (3P) 24 V - LAD4TB DT20–DT40 (4P) 72 V - LAD4TS Screw clamp D40–D95 (3P) 24 V - LA4DB2B D65 and D80 (4P) 72 V - LA4DB2S D40–D95 (3P) - 24 V LA4DB3B D65 and D80 (4P) - 72 V LA4DB3S RC circuits (Resistor-Capacitor) Effective protection for circuits highly sensitive to "high frequency" interference. For use only in cases where the voltage is virtually sinusoidal, i.e. less than - 5% total harmonic distortion. Voltage limited to 3 Uc max and oscillating frequency limited to 400 Hz max. Slight increase in drop-out time (1.2 to 2 times the normal time) Clip-on D09–D38 (3P) 12–24 V - LAD4RCE DT20–DT40 (4P) 110–240 V - LAD4RCU Screw fixing D40–D150 (3P) 24–48 V - LA4DA2E and 50–127 V - LA4DA2G D65–D115 (4P) 110–240 V - LA4DA2U 380–415 V - LA4DA2N TeSys D-line

For other versions, please consult with your localSchneider Electric / Square D sales office: visit www.us.telemanique.com.5/8 Rated operational current Ie max AC-3 (Ue - 440V) 185 A 225 A 265 A 330 A Ie AC-1 (θ - 40° C) 275 A 315 V 350 A 400 A Rated operational voltage 1 000 V 1 000 V 1 000 V 1 000 V Number of poles 3 or 4 3 or 4 3 or 4 3 or 4 Rated operational power 220/240 V 75 Hp 75 Hp 100 Hp 125 Hp in category AC3 380/400 V 125 Hp 150 Hp 200 Hp 250 Hp

415 V 125 Hp 150 Hp 175 Hp 220 Hp

440 V 125 Hp 150 Hp 175 Hp 300 Hp

500 V 150 Hp 175 Hp 250 Hp 300 Hp

660/690 V 150 Hp 175 Hp 250 Hp 350 Hp

1000 V 125 Hp 125 Hp 200 Hp 250 Hp

Contactor type (1) LC1F185 LC1F225 LC1F265 LC1F330 Reversing contactor type (1) LC2F185 LC2F225 LC2F265 (1) Basic catalog number to be completed by adding the coil voltage code. Example: LC1F18567. Standard control circuit voltages AC supply Volts 24 48 110 115 120 208 220 230 240 380 400 415 440 Contactors LC1F115–F225 (0.85–1.1UC)

50 Hz (coil LX1) B5 E5 F5 FE5 - - M5 P5 U5 Q5 V5 N5 -

60 Hz (coil LX1) - E 6F 6- G 6 L 6M 6 - U 6 Q 6 - - R 6 U7

40–400 Hz (coil LX9) - E7 F7 FE7 G7 L7 M7 P7 U7 Q7 V7 N7 R7 Contactors LC1F265–F330U7 40–400 Hz (coil LX1) B7 E7 F7 FE7 G7 L7 M7 P7 U7 Q7 V7 N7 R7 Contactors LC1F400–F630U7 40–400 Hz (coil LX1) - E 7F 7F E 7 G 7 (1) L7 M7 P7 U7 Q7 V7 N7 R7 Contactor LC1F780U7 40–400 Hz (coil LX1) - - F7 FE7 F7 L7 M7 P7 U7 Q7 V7 N7 R7 Contactor LC1F800U7 40–400 Hz (coil LX1) - - FE7 FE7 FE7 - P7 P7 P7 V7 V7 V7 V7 Y7 DC supply Volts 24 48 110 125 220 230 250 400 440 Contactors LC1F115–F330(0.85–1.1UC) (coil LX4F) BD ED FD GD MD MD UD - RD Contactors LC1F400–F630(0.85–1.1UC) (coil LX4F) -E D F D G D M D -U D - R D Contactor LC1F780(0.85–1.1UC) (coil LX4F) -- F D G D M D -U D - R D Contactor LC1F800(0.85–1.1UC) (coil LX4F) - - FW FW MW MW - QW - Example: For a 630 A c ontactor with a 110 VAC coil, order LC1F630F7. (1) F7 for LC1F630. TeSys F-line Contactors 30–900 Hp

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/9 Auxiliary contact blocks ■■■■■ instantaneous dust & damp protected contacts ■■■■■ time delay 1N.O. + 1 N.C. Composition Catalog number Composition Catalog number Composition Catalog number Composition Catalog number Type Range Catalog number 1- LADN10 11 LADN11 22 LADN22 2 -- - LA1DX20 On-delay 0.1–3 s LADT0 -1 LADN01 2- LADN20 13 LADN13 22- - LA1DY20 0.1–30 s LADT2 -2 LADN02 4- LADN40 2- 2 - LA1DZ40 10–180 s LADT4 -4 LADN04 2- 1 1 LA1DZ31 1–30 s LADS2 31 LADN31 Off-delay 0.1–3 s LADR0 22 LADC22 0.1–30 s LADR2 10–180 s LADR4 Mounting accessories for 3-pole reversing contactors for motor control 2 identical contactors, horizontally mounted Mechanical interlock with an electrical interlocking kit for the contactors Contactor type Set of connections Mechanical interlock LC1F115 LA9FF976 LA9FF970 LC1F150 LA9F15076 LA9FF970 LC1F185 LA9FG976 LA9FG970 LC1F225 LA9F22576 LA9FG970 LC1F265 LA9FH976 LA9FJ970 LC1F330 LA9FJ976 LA9FJ970 LC1F400 LA9FJ976 LA9FJ970 LC1F500 LA9FK976 LA9FJ970 LC1F630 or LC1F800 LA9FL976 LA9FL970

400 A 500 A 630 A 780 A 800 A

500 A 700 A 1 000 A 1 600 A 1 000 A

1 000 V 1 000 V 1 000 V 1 000 V 1 000 V 2, 3 or 4 2, 3 or 4 2, 3 or 4 3 or 4 3

150 Hp 200 Hp 300 Hp 350 Hp 400 Hp

300 Hp 400 Hp 450 Hp 600 Hp 600 Hp

350 Hp 450 Hp 500 Hp 500 Hp 600 Hp

400 Hp 400 Hp 600 Hp 500 Hp 600 Hp

300 Hp 475 Hp 600 Hp 600 Hp 600 Hp

450 Hp 450 Hp 600 Hp 600 Hp 600 Hp

250 Hp 450 Hp 600 Hp 600 Hp 600 Hp

LC1F400 LC1F500 LC1F630 LC1F780 LC1F800 For customer assembly TeSys F-line

For other versions, please consult with your localSchneider Electric / Square D sales office: visit www.us.telemanique.com.5/10 Thermal-magnetic circuit-breakers GV2ME for connection by spring terminals Add the figure 3 to the end of the catalog number. Example GV2ME223 (available up to GV2ME22) TeSys Type GVZME and GV2P Manual motor starters 0.1–30 Hp Manual motor starters GV2ME and GV2P for connection by screw clamp terminals GV2ME with pushbutton control, GV2P control by rotary knob Horsepower ratings of 3-phase motors 50/60 Hz Setting range M agnetic Catalog Number

200 V 230 V 460 V 575 V of thermal tripping

trips current P ush button Rotary Handle AA - - - - 0.1–0.16 1.5 GV2ME01 GV2P01 - - - - 0.16–0.25 2.4 GV2ME02 GV2P02 - - - - 0.25–0.40 5 GV2ME03 GV2P03 - - - - 0.40–0.63 8 GV2ME04 GV2P04 - - 0.5 0.5 0.63–1 13 GV2ME05 GV2P05 - - 0.75 1 1–1.6 22.5 GV2ME06 GV2P06 0.75 1 2 3 2.5–4 51 GV2ME08 GV2P08 1.5 1.5 3 5 4–6.3 78 GV2ME10 GV2P10 2 3 5 7.5 6–10 138 GV2ME14 GV2P14 3 3 10 10 9–14 170 GV2ME16 GV2P16 5 5 10 15 13–18 223 GV2ME20 GV2P20 5 7.5 15 20 17–23 327 GV2ME21 GV2P21 5 7.5 15 20 20–25 327 GV2ME22 GV2P22 10 10 20 30 24–32 416 GV2ME32 GV2P32 Thermal-magnetic circuit-breakers GV2ME for connection by spring terminals Add the number 3 to the end of the catalog number. Example GV2ME223 (available up to GV2ME22) Fuse holder—30 A rated, type CC or KTK-R fuses Catalog Number With screw terminals LS1D30 With spring terminals LS1D303 Auxiliary pole (screw terminals; LA8D324 mount on left or right side)

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/11 Accessories Combination block For mounting on LC1K or LP1K LC1D09–D38 LAD31 and LC1D09–D38 GV2AF01 GV2AF3 GV2AF4 Sets of 3-pole busbars

63 A Pitch 45 mm 54 mm 72 mm

Number of tap-offs 2 GV2G245 GV2G254 GV2G272

3 GV2G345 GV2G354

4 GV2G445 GV2G454 GV2G472

5 GV2G554

For unused busbar outlets GV1G10 Terminal blocks For supply to one or more GV2G busbar sets connection from the top can be fitted with current limiter GV1L3 (GV2ME and GV2P) GV1G09 GV1G05 Padlockable external operator for GV2P (150 to 290 mm) Padlocking In “On” and “Off ” position In “Off ” position Handle black red Legend plate blue yellow IP 54 GV2AP01 GV2AP02 Padlocking device For all GV2 devices For use with up to 6 padlocks (padlocks not supplied) Ø 6 mm shank max GV2V03 Add-on blocks Contact blocks Instantaneous auxiliary contacts point Mounting f ront GVAE1 GVAE11 GVAE20 LH side GVAN11 GV AN20 Fault signalling contact + instantaneous auxiliary contact LH side GVAD1010 GVAD1001 GVAD0110 GVAD0101 Short-circuit signalling contact LH side GVAM11 Electric trips Undervoltage or shunt trips (1) Side mounting (1 block on RH side of circuit-breaker) 50 Hz 60 Hz Voltage (AC) 24 V GV A 025 GVA 026

48 V GV A055 GVA 056

100 V GV A107

100–110 V GV A107 110–115 V GV A115 GVA 116 120–127 V GV A125

127 V GV A115

200 V GV A207

200–220 V GV A207 220–240 V GV A225 GVA 226 380–400 V GV A385 GVA 386 415–440 V GV A415

415 V GV A416

(1) Undervoltage trips: replace the  with U, shunt trips: replace the  with S TeSys Type GVZME and GV2P

For other versions, please consult with your localSchneider Electric / Square D sales office: visit www.us.telemanique.com.5/12 Add-on blocks Contact blocks Instantaneous auxiliary contacts (1 per breaker) GV3A01 GV3A02 GV3A03 GV3A05 GV3A06 GV3A07 Fault signalling contact Normal early break type contacts N.C. N.O. GV3A08 GV3A09 Electric trips Voltage 50 Hz 110, 120, 127 V 220, 240 V 380, 415 V

60 Hz 120, 127 V 277 V 440, 480 V

Undervoltage trip GV3B11 GV3B22 GV3B38 Shunt trip GV3D11 GV3D22 GV3D38 Padlocking device Start button (for bare device) GV1V02 (1) + 2 volt free terminals TeSys Type GV3ME Manual motor starters 0.5–60 Hp Manual motor starters GV3ME for connection by screw clamp terminals Pushbutton control Horsepower ratings of 3-phase motors 50/60 Hz Setting range of thermal trips Catalog Number

200 V 230 V 460 V 575 V A

  • - 0.75 1 1–1.6 GV3ME06 0.75 1 2 3 2.5–4 GV3ME08 1.5 1.5 3 - 4–6 GV3ME10 2 3 5 7.5 6–10 GV3ME14 3 5 10 10 10–16 GV3ME20 5 7.5 15 20 16–25 GV3ME25 10 10 30 30 25–40 GV3ME40 20 20 40 60 40–63 GV3ME63 20 25 50 60 56–80 GV3ME80

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/13 Add-on blocks Contact blocks Auxiliary contacts Contact type C.O. GV7AE11 Thermal or magnetic fault discrimination 24–48 VAC/DC or 24–72 VDC 110–240 VAC/DC GV7AD111 GV7AD112 Electric trips Voltage 50/60 Hz 48 V 110–130 V 200–240 V 380–440 V

50 Hz 525 V

Undervoltage trip (1) GV7AU055 GV7AU107 GV7AU207 GV7AU387 GV7AU525 Shunt trip (1) GV7AS055 GV7AS107 GV7AS207 GV7AS387 GV7AS525 (1) For mounting of a GV7AD or a GV7AU or AS Accessories T erminal shields IP 405 Supplied with the sealing accessory GV7AC01 Phase barriers used when fitting of shields is impossible GV7AC04 Insulating screens Ensure insulation between the connections and the backplate GV7AC05 Kit for combination with contactor Allowing link between the circuit-breaker and the contactor LC1F115 to F185 LC 1F225 and F26 LC1D115 and D150 GV7AC06 GV7AC07 GV7AC08 Rotary handles Handle black red Legend plate black yellow ■■■■■ direct IP 40 GV7AP03 GV7AP04 ■■■■■ extended IP 55 GV7AP01 GV7AP02 Conversion accessory for mounting on enclosure door IP 43 GV7AP05 Locking device For starter not fitted with a rotary handle GV7V01 TeSys T ype GV7R Manual motor starters 1–120 Hp Manual motor starters GV7R for connection by screw clamp terminals Control by rocker lever Horsepower ratings of 3-phase motors 50/60 Hz Setting range of thermal trips Catalog Number

230 V 460V 575 V A

5 10 15 12–20 GV7RE20 5 10 15 12–20 GV7RS20 7.5 15 20 15–25 GV7RE25 7.5 15 20 15–25 GV7RS25 10 30 30 25–40 GV7RE40 10 30 30 25–40 GV7RS40 15 30 40 30–50 GV7RE50 30 60 75 48–80 GV7RE80 30 60 75 48–80 GV7RS80 30 75 100 60–100 GV7RE100 30 75 100 60–100 GV7RS100 50 100 150 90–150 GV7RE150 50 100 150 90–150 GV7RS150 75 150 200 132–220 GV7RE220 75 150 200 132–220 GV7RS220

For other versions, please consult with your localSchneider Electric / Square D sales office: visit www.us.telemanique.com.5/14 Auxiliary early break and/or signalling contacts Switch rating 30–200 A 50–400 A 600–800A 50–400 V Standard contacts GS1AM110 GS1AM101 GS1AM1 GS1AM2 GS1AMU3 GS1AMU4 GS1AN11 GS1AN22 TeSys GS1 Switch-disconnector-fuses 0–1250 A GS1 fusible disconnect switch 30–800 A Catalog number GS1DDU3 GS1DU3 GS1 EERU20 GS1EERU30 G S1EEU3 Switc h T ype Compact fused Com pact fused Fused Fused Fused Fuses CC J CC CC CC Amps 30 30 30 30 30 Poles 3323 3 Operator Style Thru-the-door Thru-the-door Side handle Side handle Thr u-the-door Max. HP 3 Phase: kW/hp at 480V 11/15 11/15 n/a 11/15 11/15 kW/hp at 600V 15/20 15/20 n/a 15/20 15/20 LK3 non-fused disconnect switch 30–1200 A Catalog number LK3GU3 LK3GU3 LK3JU3 LK3MU3 (1) LK3QU3 (1) Switc h T ype Compact Non-fused Non-fused Non-fused Non-fused Non-fused Amps 30 60 100 200 400 Poles 3333 3 Operator Style Thru-the-door Thru-the-door Thru-the-door Thru-the-door Thru-the-door Max. HP 3 Phase: kW/hp at 240V 5.5.7. 5 11/15 22/30 45/60 90/125 kW/hp at 480V 11/15 22/30 45/60 90/125 185/250 kW/hp at 600V 15/20 37/50 55/75 110/150 250/350 (1) T er minal lugs must be ordered separately .

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/15 GS1EU3 GS1GU3 GS1JU3 (1) GS1MU3 (1) GS1QU3 (1) GS1SU3 (1) GS1TU3 (1) Fused Fused Fused Fused Fused Fused Fused J J JJJJL 30 60 100 200 400 600 800 3 3 33333 Thru-the-door Thru-the-door Thru-the-door Thru-the-door Thru-the-door Thru-the-door Thru-the-door 5.5/7.5 11/15 22/30 45/60 90/125 185/250 185/250 11/15 22/30 45/60 90/125 185/250 370/500 370/500 15/20 37/50 55/75 110/150 250/350 370/500 370/500 LK3SU3 (1) LK3TU3 (1) LK3UU3 (1) LK3WU3 Non-fused Non-fused Non-fused Non-fused 600 800 1000 1200 33 3 3 Thru-the-door Thru-the-door Thru-the-door Thru-the-door 150/200 185/250 185/250 185/250 300/400 370/500 370/500 370/500 250/350 370/500 370/500 370/500 (1) Terminal lugs must be ordered separ ately. TeSys GS1

For other versions, please consult with your localSchneider Electric / Square D sales office: visit www.us.telemanique.com.5/16 Thermal overload relays, model k adjustab le from 0.11 to 12 A Connection by screw clamp terminals, direct mounting on contactors LC1K, manual or automatic reset Relay setting range Fuses to be used with selected relay (international applications only) (5) Catalog number Class 10 A aM gG BS88 0.11–0.16 A 0.25 A 0.5 A - LR2K0301 0.16–0.23 A 0.25 A 0.5 A - LR2K0302 0.23–0.36 A 0.5 A 1 A - LR2K0303 0.36–0.54 A 1 A 1.6 A - LR2K0304 0.54–0.8 A 1 A 2 A - LR2K0305 0.8–1.2 A 2 A 4 A 6 A LR2K0306 1.2–1.8 A 2 A 6 A 6 A LR2K0307 1.8–2.6 A 2 A 6 A 10 A LR2K0308 2.6–3.7 A 4 A 10 A 16 A LR2K0310 3.7–5.5 A 6 A 16 A 16 A LR2K0312 5.5–8 A 8 A 20 A 20 A LR2K0314 8–11.5 A 10 A 25 A 20 A LR2K0316 Thermal overload relays f or use on class 10 A unbalanced loads: for above cat alog numbers LR2K0305 to LR2K0316 only, replace the prefix LR2 with LR7. Example LR7K0310. Accessories Prewiring kit Allowing direct connection of the N.C. contact For use on of relay LRD01–35 or LR3D01–D35 to the contactor LC1D09–D18 LAD7C1 LC1D25–D38 LAD7C2 T erminal blocks (1) For clip-on mounting on 35 mm mounting rail (AM1-DP200) LRD01–35 and LR3D01–D35 LAD7B10 or screw fixing LRD3, LR3D3, LRD35 LA7D3064 (2) For independent mounting of the relay LR2K  LA7K0064 T erminal block adapter For mounting a relay beneath an LC1D115 or D150 contactor LRD 3, LR3D3, LRD35 LA7D3058 Stop or electrical reset Remote (3) LRD01–35 and LR3D01–D35 LAD703 (4) T ripping or electrical reset device Remote (3) All relays except LRD01–35 and LR3D01–D35 LA7D03 (4) (1) Terminal bloc ks are supplied with terminals protected against direct finger contact and scre ws in the open “ready-to-tighten” position. (2) T o order a terminal block f or connection by lug-clamps , the catalog n umber becomes LA7D30646. (3) The time for which the coil of remote tripping or electrical resetting device LA76D03 or LAD703 can remain energized depend s on its rest time: 1 s pulse duration with 9 s rest time; maximum pulse duration of 20 s with a rest time of 300 s. Minimum pulse time 200 ms. (4) Catalog number to be completed by adding the code indicating the control circuit voltage. (5) Short circuit protection for U.S. applications: circuit breakers selected in accordance with NEC and local codes; fuses sel ected with maximum of 400% full load current. Standard control circuit voltages AC supply Volts 12 24 48 96 110 220/230 380/400 415/440 50/60 Hz. Consumption, inrush and sealed < 100 VA -B E -F M Q N DC supply Consumption, inrush and sealed < 100 W JB ED D FM - - TeSys K-line Thermal overload relays 0.11–11.5 A

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/17 Thermal overload relays, model d adjustable from 0.1 to 140 A Compensated relays with manual or automatic reset, with relay trip indicator, for AC or DC Relay setting range Fuses to be used with selected relay (international applications only) (5) With contactor Catalog number aM gG BS88 Class 10 A 0.10–0.16 A 0.25 A 2 A - LC1D09–D38 LRD01 0.16–0.25 A 0.5 A 2 A - LC1D09–D38 LRD02 0.25–0.40A 1 A 2 A - LC1D09–D38 LRD03 0.40–0.63 A 1 A 1.6 A - LC1D09–D38 LRD04 0.63–1 A 2 A 4 A - LC1D09–D38 LRD05 1–1.7 A 2 A 4 A 6 A LC1D09–D38 LRD06 1.6–2.5 A 4 A 6 A 10 A LC1D09–D38 LRD07 2.5–4 A 6 A 10 A 16 A LC1D09–D38 LRD08 4–6 A 8 A 16 A 16 A LC1D09–D38 LRD10 5.5–8 A 12 A 20 A 20 A LC1D09–D38 LRD12 7–10 A 12 A 20 A 20 A LC1D09–D38 LRD14 9–13 A 16 A 25 A 25 A LC1D12–D38 LRD16 12–18 A 20 A 35 A 32 A LC1D18–D38 LRD21 16–24 A 25 A 50 A 50 A LC1D25–D38 LRD22 23–32 A 40 A 63 A 63 A LC1D25–D38 LRD32 30–38 A 50 A 80 A 80 A LC1D32 and D38 LRD35 17–25 A 25 A 50 A 50 A LC1D40–D95 LRD3322 23–32 A 40 A 63 A 63 A LC1D40–D95 LRD3353 30–40 A 40 A 100 A 80 A LC1D40–D95 LRD3355 37–50 A 63 A 100 A 100 A LC1D40–D95 LRD3357 48–65 A 63 A 100 A 100 A LC1D50–D95 LRD3359 55–70 A 80 A 125 A 125 A LC1D50–D95 LRD3361 63–80 A 80 A 125 A 125 A LC1D65 and D95 LRD3363 80–104 A 100 A 160 A 160 A LC1D80 and D95 LRD3365 80–104 A 125 A 200 A 160 A LC1D115 and D150 LRD4365 95–120 A 125 A 200 A 200 A LC1D115 and D150 LRD4367 110–140 A 160 A 250 A 200 A LC1D150 LRD4369 80–104 A 100 A 160 A 160 A (1) LRD33656 95–120 A 125 A 200 A 200 A (1) LRD33676 110–140 A 160 A 250 A 200 A (1) LRD33696 Class 20 A 6 A 10 A 16 A LC1D09–D32 LRD1508 4–6 A 8 A 16 A 16 A LC1D09–D32 LRD1510 5.5–8 A 12 A 20 A 20 A LC1D09–D32 LRD1512 7–10 A 16 A 20 A 25 A LC1D09–D32 LRD1514 9–13 A 16 A 25 A 25 A LC1D12–D32 LRD1516 12–18 A 25 A 35 A 40 A LC1D18–D32 LRD1521 17–25 A 32 A 50 A 50 A LC1D25 and D32 LRD1522 23–28 A 40 A 63 A 63 A LC1D25 and D32 LRD1530 25–32 A 40 A 63 A 63 A LC1D25 and D32 LRD1532 17–25 A 32 A 50 A 50 A LC1D40–D95 LR2D3522 23–32 A 40 A 63 A 63 A LC1D40–D95 LR2D3553 30–40 A 50 A 100 A 80 A LC1D40–D95 LR2D3555 37–50 A 63 A 100 A 100 A LC1D50–D95 LR2D3557 48–65 A 80 A 125 A 100 A LC1D50–D95 LR2D3559 55–70 A 100 A 125 A 125 A LC1D65–D95 LR2D3561 63–80 A 100 A 160 A 125 A LC1D80 and D95 LR2D3563 (1) Separate mounting. Screw clamp terminal connections or connectors. For spring terminal connections on LRD01 to LRD22, add 3 to the end of the catalog number. Example: LRD01 becomes LRD013. For lug-clamp connections, add 6 to the end of the catalog number . Example: LRD01 becomes LRD016. For thermal overload relays for use with class 10 A unbalanced loads, with connection by scre w clamp terminals, change the prefix in the catalog n umbers abo ve from LRD (e xcept LRD4) to LR3D . Example LRD01 becomes LR3D01. (5) Short circuit protection for U.S. applications: circuit breakers selected in accordance with NEC and local codes; fuses selecte d with maximum of 400% full load current. Thermal overload relays 0.1–140 A TeSys D-line

For other versions, please consult with your localSchneider Electric / Square D sales office: visit www.us.telemanique.com.5/18 For use with contactor LC1D LC1F Motor current 60–150 A 30–630 A Catalog number , to be completed LR9D LR9F Relay setting range Fuse to be used with selected relay For mounting Compensated and differential (international application) (3) beneath contactor LC1 or not with alarm aM gG Class 10 Class 20 Class 10 or 20 60–100 100 160 D 115 and D150 LR9D5367 LR9D5567 90–150 160 250 D 115 and D150 LR9D5369 LR9F5569 30–50 50 80 F115–F185 LR9F5357 LR9F5557 LR 9F57 48–80 80 125 F115–F185 LR9F5363 LR9F5563 LR 9F63 60–100 100 200 F115–F185 LR9F5367 LR9F5567 LR 9F67 90–150 160 250 F115–F185 LR9F5369 LR9F5569 LR 9F69 132–220 250 315 F185–F400 LR9F5371 LR9F5571 LR 9F71 200–330 400 500 F225–F500 LR9F7375 LR9F7575 LR 9F75 300–500 500 800 F225–F500 LR9F7379 LR9F7579 LR 9F79 380–630 630 800 F400–F630 and F800 LR9F7381 LR9F7581 LR 9F81 Accessories Remote control Function Reset Stop and/or Reset Reset by flexible cable (length 0.5 m) LA7D305 Adapter for door interlock mechanism LA7D1020 Operating head for pushbutton Spring return ZA2BL639 ZA2BL432 Rod with snap-off end Adjustable from 17 to 120 mm ZA2BZ13 Insulated terminal blocks For relays LR9F557, F563, F567, F569, F57, F63, F67 and F69 Set of 2 blocks LA9F103 (1) The time for which the coil of remote electrical reset device LA7D03 can remain energized depends on its rest time: 1 s pul se with 9 s rest time; 5 s pulse duration with 30 s rest time; 10 s pulse duration with 90 s rest time: maximum pulse duration 20 s with rest time of 300 s. Minimum pulse tim e: 200 ms. (2) Catalog number to be completed by adding the coil voltage code, see page 5/27. (3) Short circuit protection for U.S. applications: circuit breakers selected in accordance with NEC and local codes; fuses selecte d with maximum of 400% full load current. TeSys F-line Electronic thermal overload relays 60–630 A

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/19 For use with contactor LC1-D or LC1-F Motor current No limit Basic reference, to be completed L T3S 3-pole multifunction protection relays Operational current A 0.2–1. 1–5 L T6P0M005FM Protection units with automatic reset with thermistor short-circuit detection ■■■■■ without fault memory Connection Voltage O utput contact Catalog number by cage connectors AC 50/60 Hz 115 V N.C. LT3SE00F 230 V N.C. L T3SE00M DC 24 V N.C. LT3SE00F On front panel: fault and voltage signalling indicator AC 50/60 Hz 115/230 V N.C. + N.O. L T3SA00M DC 24/48 V N.C. + N.O. L T3SA00ED AC 50/60 Hz or DC 24–230 V 2 C.O. LT3SA00MW On front panel: fault and v oltage signalling indicator, Test and Reset b utton AC 50/60 Hz 400 V N.C. + N.O. L T3SM00V 24/48 V N.C. + N.O. L T3SM00E 115/230 V N.C. + N.O. L T3SM00M DC 24/48 V N.C. + N.O. LT3SM00ED AC 50/60 Hz or DC 24–230 V 2 C.O. L T3SM00MW TeSys LT3, LT6 Electronic protection relays for use with PTC thermistor probes 0–800 A LT6LT3

For other versions, please consult with your localSchneider Electric / Square D sales office: visit www.us.telemanique.com.5/20 Vario Protection components 12–175 A Switch disconnectors Type Mini-Vario for standard applications Mounting door Backplate mounting in enclosure Handle color / Front plate Red / Yellow Black / Black Red / Yellow Front plate dimensions (mm) 60 x 60 60 x 60 Mounting Ø 22.5 mm Ø 22.5 mm Degree of protection IP 20 IP 20 Rated operational voltage (Ue) 600 V 600 V Thermal current in open air (Ith) 10/12 A VCDN12 VBDN12 VCCDN12 16/20 A VCDN20 VBDN20 VCCDN20 Type Vario for high performance applications Mounting door Backplate mounting in enclosure Handle color/ Front plate Red / Yellow Black / Black Red / Yellow Black / Black Red / Yellow Front plate dimensions 60 x 60 mm 60 x 60 mm 90 x 90 MM 60 x 60 mm 90 x 90 mm Mounting Ø 22.5 mm 4 screws 4 screws Ø 22.5 mm 4 screws 4 screws Degree of protection IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 Rated operational voltage (Ue) 600 V 600 V 600 V 600 V 600 V 600 V Thermal current in open air :UL/IEC (A) 10/12 A VCD02 VBD02 VCF02 VBF02 – VCCD02 VCCF02 – 16/20 A VCD01 VBD01 VCF01 VBF01 – VCCD01 VCCF01 – 20/25 A VCD0 VBD0 VCF0 VBF0 – VCCD0 VCCF0 – 20/32 A VCD1 VBD1 VCF1 VBF1 – VCCD1 VCCF1 – 25/40 A VCD2 VBD2 VCF2 VBF2 – VCCD2 VCCF2 – 45/63 A – – VCF3 VBF3 –– VCCF3 – 63/80 A – – VCF4 VBF4 –– VCCF4 –

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/21 Add-on modules For mini-Vario For Vario Main pole modules Rating:UL/IEC (A) 10/12 A 16/20 A 10/12 A 16/20 A 20/25 A 20/32 A 25/40 A 45/63 A 63/80 A Catalog number VZN12 VZN20 VZ02 VZ01 VZ0 VZ1 VZ2 VZ3 VZ4 Neutral pole module with early make and late break contacts Rating 12–20 A 12–40 A 63 and 80 A 125 and 175 A Catalog number VZN11 VZ11 VZ12 VZ13 Earthing module Catalog number VZN14 VZ14 VZ15 VZ16 Auxiliary contact b lock modules Catalog number VZN05 VZN06 VZ7 VZ20 Vario

For other versions, please consult with your localSchneider Electric / Square D sales office: visit www.us.telemanique.com.5/22 Power base for D.O.L. starter ■■■■■ Non reversing ■■■■■ Reversing Connection by screw clamp terminals Catalog number Current rating Catalog number Current rating Operational voltage 200/208 V 230/240 V 460 V 575/600 V Horseposer rating (UL ratings) 3 3 7.5 10 LUB12 12 A LU2B12 12 A 10 10 20 25 LUB32 32 A LU2B32 32 A Add-on blocks Contact blocks Signalling Contact ■ status of starter-controller power poles N.O. (53-54) ■ control handle in position O N.O. (17-18) N.O. (17-18) Connection Item 1 1 1 1 1 1 ■ screw clamp terminals 1 + 2 LUA1D11 LUA1C11 LUA1C20 ■ without connections 1 LUA1D110 LUA1C110 LUA1C200 Auxiliary contact blocks 2- 1 1- 2 ■ screw clamp terminals 3 LUFN20 LUFN11 LUFN02 Modules ■■■■■ parallel wiring LUFC00 ■■■■■ communication As-i Modbus ASILUFC5 LULC032 ■■■■■ indication of motor load 4–20 mA LUFV2 ■ ■ ■ ■ ■ fault differentiation and reset manual reset automatic reset LUFDH11 LUFDA10 TeSys U-line Self protected starter 0–32 A

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/23 Standard control circuit voltages (for other voltages, please consult your Regional Sales Office) Volts 24 48–72 110–240 DC BL - - AC B-- AC/DC -E S (1) FU (2) (1) 48–72 VDC, 48 VAC. (2) 110–220 VDC, 110–240 VAC. Control units Setting range Clip-in mounting on power base 0.15–0.6 12 and 32 LUCAX6 0.35–1.4 12 and 32 LUCA1X 1.25–5 12 and 32 LUCA05 3–12 12 and 32 LUCA12 4.5–18 32 LUCA18 8–32 32 LUCA32 ■■■■■ advanced Class 10 Class 20 For motor type ■■■■■ 3-phase ■■■■■ single-phase 3- phase 12 and 32 LUCBX6 LUCCX6 LUCDX6 12 and 32 LUCB1X LUCC1X LUCD1X 12 and 32 LUCB05 LUCC05 LUCD05 12 and 32 LUCB12 LUCC12 LUCD12 ■■■■■ multifunction Class 5 to 35 12 and 32 LUCMX6BL 12 and 32 LUCM1XBL 12 and 32 LUCM05BL 12 and 32 LUCM12BL

32 LUCM18BL

32 LUCM32BL

Basic catalog number to be completed by adding the voltage code (1) Parameter entry, monitoring of parameter values and consultation of logs are carried out: „ either on the front panel, using the built-in display window/ keypad, „ or via an operator terminal, „ or via a PC or a PDA with PowerSuite software , „ or remotely , via a Modbus communication bus . Programming of the product via the keypad requires a 24 Vdc auxiliary power supply. TeSys U-line

For other versions, please consult with your localSchneider Electric agency/ Square D sales office: visit www.us.telemanique.com.5/24 Above 32 A, the U-line Solid state overload relay system provides a motor starter management solution identical to that provided by T eSys U-line starter-controller . Used in conjunction with a short-circuit protection device and a contactor, it provides a motor starter whose functions are the same as those of a T eSys U-line self protected star ter and, in parti cular, provides motor starter overload protection and control functions . It consists of a control unit whose adjustment range is compatible with the secondary of current transformers, plus a control base which also allows fitment of a function module or a communication module . It requires a 24 VDC external power supply. Control bases For use with contactors Current transformers (auxiliary supply voltage 24 VDC) Connection screw Control screw LUTM10BL T eSys model D Control units For 3-phase motors Cl ass 10 Class 20 Class 5 to 30 Setting range 0 .35–1.05 ■■■■■ advanced LUCBT1BL LUCDT1BL ■■■■■ multifunction LUCMT1BL TeSys U-line Solid state overload relay system 0–800 A

For other versions, please consult with your local Schneider Electric agency/ Square D sales office: visit www.us.telemanique.com. 5/25 Current transformers Operational current ■■■■■ primary 30 50 100 200 400 800 ■■■■■ secondary LUTC0301 LUTC0501 LUTC1001 LUTC2001 LUTC4001 LUTC8001 Accessories Module ■■■■■ communication Modbus LULC033 ■■■■■ indication of motor load 4–20 mA LUFV2 TeSys U-line

For other versions, please consult with your localSchneider Electric agency/ Square D sales office: visit www.us.telemanique.com.5/26 IEC type industrial control relays TeSys Type CA2K, CA3K and CA4K CA2-K control relays (0.8–1.15 Uc) (0.85–1.1UC) Volts A C, 50/60 Hz 12 24 36 42 48 110 120 127 208 220/230 230 230/240 380/400 400 400/415 440 480 500 660/690 Code J7 B7 C7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 Q7 V7 N7 R7 T7 S7 Y7 Up to and including 240 V. Coil with integral suppression device a vailable: add 2 to the code required. Example: J72. CA3-K control relays (0.8–1.15 Uc) Volts DC 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD LD MD MPD MUD UD Coil with integral suppression device available: add 3 to the code required. Example: JD3 CA4-K, low consumption control relays (wide range coil : 0.7–1.3 Uc) Volts DC 12 24 48 72 Code JW3 BW3 EW3 SW3 For additional options and information, reference catalog 8501CT0101. Control relays ■ Mounting on 35 mm DIN 3 track or 4 screw direct mounting Control Circuit Type of T erm ination Contact ConfigurationCatalog number (1) ■ Screws in open “ready-to-tighten” position Supply Consumption N.O. N.C. ■ NEMA A600, Q600 40 CA2KN40 ■ IEC AC15, DC13 AC 4.5 VA screw clamp 3 1 CA2KN31

22 CA2KN22

40 CA2KN403

AC 4.5 VA spring terminals 3 1 CA2KN313

22 CA2KN223

40 CA2KN407

AC 4.5 VA Slip-on 1 x 6.35 or 2 x 2.8 3 1 CA2KN317

22 CA2KN227

40 CA2KN405

AC 4.5 VA solder pins for printed circuit board 31 CA2KN315

22 CA2KN225

40 CA3KN40

DC 3 W screw clamp 3 1 CA3KN31

22 CA3KN22

40 CA3KN403

DC 3 W spring terminals 3 1 CA3KN313

22 CA3KN223

40 CA3KN407

DC 3 W Slip-on 1 x 6.35 or 2 x 2.8 3 1 CA3KN317

22 CA3KN227

40 CA3KN405

DC 3 W solder pins for printed circuit board 31 CA3KN315

22 CA3KN225

Low consumption control relays ■ Compatible with programmable controller outputs 40 CA4KN40 ■ LED indicator incorporated DC 1.8 W screw clamp 3 1 CA4KN31 ■ Wide range coil (70 to 130% Uc), suppressor fitted as standard 2 2 CA4KN22 ■ Mounting on 35 mm DIN 3 track or 4 screw direct mounting 40 CA4KN403 ■ Screws in open “ready-to-tighten” position DC 1.8 W spring terminals 3 1 CA4KN313

22 CA4KN223

40 CA4KN407

DC 1.8 W Slip-on 1 x 6.35 or 2 x 2.8 3 1 CA4KN317

22 CA4KN227

40 CA4KN405

DC 1.8 W solder pins for printed circuit board 31 CA4KN315

22 CA4KN225

(1) Complete the catalog number by adding the proper voltage code from the table belo w. Example: CA4KN227BW3.

For other versions, please consult with your local Schneider Electric agency/ Square D sales office: visit www.us.telemanique.com. 5/27 Instantaneous auxiliary contact blocks ■ Clip-on front mounting, 1 block per control relay T ype of Connection Contact Configuration Catalog number ■ Auxiliary contact module not suitable for safety circuits N.O. N.C.

20 LA1KN20

02 LA1KN02

11 LA1KN11

40 LA1KN40 (1)

31 LA1KN31 (1)

22 LA1KN22 (1)

13 LA1KN13 (1)

04 LA1KN04 (1)

20 LA1KN203

02 LA1KN023

11 LA1KN113

40 LA1KN403 (1)

31 LA1KN313 (1)

22 LA1KN223 (1)

13 LA1KN133 (1)

04 LA1KN043 (1)

20 LA1KN207

02 LA1KN027

11 LA1KN117

Slip-on 1 x 6.35 or 2 x 2.8 40 LA1KN407 (1)

31 LA1KN317 (1)

22 LA1KN227 (1)

13 LA1KN137 (1)

04 LA1KN047 (1)

(1) Not to be used on CA4KN relays Electronic time delay contact blocks ■ Rela y output, with common point changeo ver contact, 240 VAC / VDC, 2 A m aximum. ■ Control voltage: 0.85–1.1 Uc. ■ Maximum switching capacity: 250 VA or 150 W. ■ Operating temperature: - 10 to + 60 °C (+14° F to 140° F). ■ Clip-on front mounting, 1 block per control relay Voltage T ype Timing Range Composition C.O. Catalog number 24–48 VAC / VDC On-delay 1–30 seconds 1 LA2KT2E 110–240 VAC On-delay 1–30 seconds 1 LA2KT2U For additional options and information, reference catalog 8501CT0101. IEC type industrial control relays

For other versions, please consult with your localSchneider Electric agency/ Square D sales office: visit www.us.telemanique.com.5/28 IEC type industrial control relays TeSys Type CAD AC 50/60 Hz coil V olts 12 24 48 120 208 240 277 480 600 Code J7 B7 E7 G7 LE7 U7 W7 T7 X7 DC coil (coils have built in suppression as standard) V olts 12 24 36 48 60 72 110 125 220 250 440 Code JD BD CD ED ND SD FD GD MD UD RD DC low consumption coil (coils have built in suppression as standard) V o l t s 5 1 2 2 44 87 2 Code AL JL BL EL SL For additional options and information, reference catalog 8501CT0101. Instantaneous control relays T erminal T ype Number of Contacts Contact Configuration Catalog n umber (1) N.O. N.C.

50 CAD50

screw clamp 5 32 CAD32

50 CAD503

32 CAD323

50 CAD506

ring tongue 5 32 CAD326 (1) Complete the catalog number by adding the proper voltage code from the table below . Example: CAD50G7. CAD32 CAD503 CAD326

For other versions, please consult with your local Schneider Electric agency/ Square D sales office: visit www.us.telemanique.com. 5/29 Instantaneous auxiliary contact blocks (for use in normal operation environments) Number of Contacts Max. Number per Device (clip-on mounting) T ermination T ype Contact Composition Catalog number Front Left Side Only N.O. N.C.

20 LADN20

2 1 – Screw Clamp 1 1 LADN11

02 LADN02

20 LADN203

2 1 – Spring T erm inal 1 1 LADN113

02 LADN023

20 LAD8N20

2 – 1 (not for DC devices) Screw Clamp 1 1 LAD8N11

02 LAD8N02

40 LADN40

31 LADN31

4 1 – Screw Clamp 2 2 LADN22

13 LADN13

04 LADN04

40 LADN403

31 LADN313

4 1 – Spring T erm inal 2 2 LADN223

13 LADN133

04 LADN043

4 1 – Screw Clamp 2 2 LADC22 (4) 4 1 – Spr ing T erminal 2 2 LADC223 (4) Instantaneous auxiliary contact blocks with dust and damp protected contacts (for use in particularly harsh industrial environments) Number of Contacts Max. Number per Device Contact Composition Catalog Number Front Mounting Sealed (1) Normal 2–– –– LA1DX20 2 1 –2– –– LA1DX02 2–2 –– LA1DY20 2–– 2– LA1DZ40 2–– 11 LA1DZ31 (1) Grounding terminal points (2 terminals jumpered together ; see diagram on page 8 of Catalog 8501CT0101). Time delay auxiliary contact blocks Number and Type Max. Number per Device Time Delay Type Term ination T ype Range C atalog Number of Contacts Fr ont Mounting 0.1 to 3 sec. (2) LADT0 1 N.C. and 1 N.O. 1 On-Delay screw clamp 0.1 to 30 sec. LADT2 10 to 180 sec. LADT4 1 to 30 sec. (3) LADS2 0.1 to 3 sec. (2) LADT03 10 to 180 sec. LADT43 1 to 30 sec. (3) LADS23 0.1 to 3 sec. (2) LADR0 10 to 180 sec. LADR4 0.1 to 3 sec. (2) LADR03 10 to 180 sec. LADR43 (Lockout Cover, see page 7 of Catalog 8501CT0101.) (2) With extended scale from 0.1 to 0.6 s. IEC type industrial control relays

For other versions, please consult with your localSchneider Electric/ Square D sales office: visit www.us.telemanique.com.5/30 NEMA Type Contactors and starters 3-pole contactors and starters, open style(1) Standard control circuit v oltages: Volts 24 110 120 208 220

50 Hz – V02 – – V03

60 Hz V01 (4) – V02 V08 –

50 Hz – V05 V06 – –

60 Hz V03 – – V06 V07

For 24 V and 120 V coils add the letter “S” f or separate control. Example: 8502SAO12 V01S. Type Contactors Starters 3-pole, open style 3-pole, open style Characteristics NEMA Standard power ratings Maximum Ba sic catalog number complete with code B asic catalog number complete with code siz e of 3-phase motors 50/60 Hz continuous indicating control circuit voltage (1) indicating control circuit voltage (1) current and optional Forms (2) optional Forms (2) and “H” code (3) Motor voltage

200 V 230 V 460 V 575 V

0 3 2.2 3 2.2 5 3.7 5 3.7 18 8502SBO2 ppppppppppppppp 8536 SBO2 ppppppppppppppp 2 10 7.5 15 11 25 18.5 25 18.5 45 8502SDO2 ppppppppppppppp 8536 SDO1 ppppppppppppppp 3 25 18,5 30 22 50 37 50 37 90 8502SEO2 ppppppppppppppp 8536 SEO1 ppppppppppppppp 4 40 30 50 37 100 75 100 75 135 8502SFO2 ppppppppppppppp 8536 SFO1 ppppppppppppppp 5 75 55 100 75 200 150 200 150 270 8502SGO2 ppppppppppppppp 8536 SGO1 ppppppppppppppp 6 150 110 200 150 400 300 400 300 540 8502SHO2 ppppppppppppppp 8536 SHO2 ppppppppppppppp 7 – – 300 220 600 450 600 450 810 8502SJO2 ppppppppppppppp 8536 SJO2 ppppppppppppppp (2) F or optional F or ms, please consult y our nearest Square D/Schneider Electric sales office. (3) Add the letter “H” for Solid State Overload Relays , see tables belo w. (4) 24 V coil is not a vailable for siz es 4 to 7. A vailable for sizes 00–3, specify the letter “S” for separate control. Solid State Overload Relays (6) Standard current ranges dependent on starter siz e: S i z e 0 0 0123 Current ranges A 1.5–4.5 (8) 6–18 9–27 15–45 30–90 S i z e 456 7 Current ranges A 45–135 90–270 180–540 (8) 270–810 (9) Form adders Motor Logic ® solid state relays Motor Logic® solid state relays Without additional auxiliary contact W ith additional auxiliary contact Description Cu rrent For use Suffix to be added Suffix to be added to rang e with to the star ter catalog number (7) the starter catalog number (7) Base unit, (6) 8536 S pppppppppp H10 H11 T rip class 10 8736 Spppppppppp Base unit, (6) 8536 S pppppppppp H20 H21 T rip class 20 8736 Spppppppppp Feature unit (6) 8536 S pppppppppp H30 H31

8736 Spppppppppp

(7) Example: 8536SAO12V01H10. (8) Only availab le with f eature units. (9) Only availab le with f eature units with auxiliary contact. F or additional infor mation, ref erence catalog 8502CT9701.

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/31 3-pole reversing contactors and reversing starters, open style(1) Standard control circuit voltages: Volts 24 110 120 208 220 For 24 V and 120 V coils add the letter “S” for separate control. Example: 8702SAO4 V01S. Type Reversing contactors Reversing starters 3-pole, open style 3-pole, open style Characteristics NEMA Standard power ratings Maxim um B asic catalog number complete with code B asic catalog n umber complete with code size of 3-phase motors 50/60 Hz continuous indicating control circuit voltage (1) indicating control circuit voltage (1) current and optional Forms (2) optional Forms (2) and “H” code (3) Motor voltage Hp kW Hp kW Hp kW Hp kW A Ver tical Side by side Ver tical Side by side 0 3 2.2 3 2.2 5 3.7 5 3.7 18 8702SBO12 ppppppppppppppp 8702SBO4 ppppppppppppppp 8736SBO10 ppppppppppppppp 8736SBO4 ppppppppppppppp 2 10 7.5 15 11 25 18.5 25 18.5 45 8702SDO1 ppppppppppppppp 8702SDO2 ppppppppppppppp 8736SDO1 ppppppppppppppp 8736SDO2 ppppppppppppppp 3 25 18.5 30 22 50 37 50 37 90 8702SEO1 ppppppppppppppp 8702SEO2 ppppppppppppppp 8736SEO1 ppppppppppppppp 8736SEO2 ppppppppppppppp 4 40 30 50 37 100 75 100 75 135 8702SFO1 ppppppppppppppp 8702SFO3 ppppppppppppppp 8736SFO1 ppppppppppppppp 8736SFO3 ppppppppppppppp 5 75 55 100 75 200 150 200 150 270 8702SGO1 ppppppppppppppp 8702SGO3 ppppppppppppppp 8736SGO1 ppppppppppppppp 8736SGO3 ppppppppppppppp 6 150 110 200 150 400 300 400 300 540 – 8702SHO1 ppppppppppppppp – 8736SHO1 ppppppppppppppp 7 – – 300 220 600 450 600 450 810 – 8702SJO1 ppppppppppppppp – 8736SJO1 ppppppppppppppp (2) For optional F orms, please consult your nearest Square D /Schneider Electric sales office . (3) Add the letter “H” for Solid State Overload Relays , see tables belo w. (4) 24 V coil is not av ailable for sizes 4 to 7. A vailable f or sizes 00–3, specify the letter “S” for separate control. Solid State Overload Relays Form adders Motor Logic® PLUS solid state relays Motor Logic ® PLUS solid state relays 200 to 480 V 600 V Suffix to be added Suffix to be ad ded Current range to the star ter catalog number (7) to the starter catalog number (7) 0.5–2.3 A B20 B24 2–9 A B30 B34 6–27 A B40 B44 10–45 A B50 B54 20–90 A B60 B64 60–135 A B70 B74 120–270 A B80 B84 240–540 A B90 B94 (7) Example: 8536SAO12V01B20. For additional inform ation, reference catalog 8502CT9701. NEMA Type

For other versions, please consult with your localSchneider Electric/ Square D sales office: visit www.us.telemanique.com.5/32 NEMA Type Combination starters 3-pole disconnect switch starters NEMA 1 general purpose enclosure NEMA 12 dust-tight and drip-tight industrial use enclosure Type 3-pole starters 3-pole starters, 3-pole starters, 3-pole starters, non-reversing non-reversing non-reversing non-reversing with Class H fuses with Class R fuses with Class H fuses with Class R fuses Characteristics Siz e Standard power ratings Fuse B asic catalog number Basic catalog number Basic catalog number Basic catalog number NEMA of 3-phase motors 50/60 Hz size com plete with code complete with code complete with code complete with code indicating control indi cating control indicating indicating circuit voltage (1) circuit voltage (1) circuit voltage (1) circuit voltage (1) optional Forms (2) and optional Forms (2) optional Forms (2) and optional Forms (2) Motor voltage (star ter voltage) and H code (3) and H code (3)

200 V (208 V) 230 V (240 V) 460 V (480 V) 575 V (600 V)

0 3 2.2 3 2.2 – – – –3 0 8538SBG12 ppppppppppppppp 8538SBG32 ppppppppppppppp 8538SBA (4) 2 ppppppppppppppp 8538SBA (5) 2 ppppppppppppppp – – – – 5 3.75 5 3.75 30 8538SBG13 ppppppppppppppp 8538SBG33 ppppppppppppppp 8538SBA (4) 3 ppppppppppppppp 8538SBA (5) 3 ppppppppppppppp 1 5 3.75 5 3.75 – – – –3 0 8538SCG12 ppppppppppppppp 8538SCG32 ppppppppppppppp 8538SCA (4) 2 ppppppppppppppp 8538SCA (5) 2 ppppppppppppppp – – – – 10 7.5 10 7.5 30 8538SCG14 ppppppppppppppp 8538SCG34 ppppppppppppppp 8538SCA (4) 4 ppppppppppppppp 8538SCA (5) 4 ppppppppppppppp 7.5 5.5 7.5 5.5 – – – –6 0 8538SCG13 ppppppppppppppp 8538SCG33 ppppppppppppppp 8538SCA (4) 3 ppppppppppppppp 8538SCA (5) 3 ppppppppppppppp 2 10 7.5 15 11 – – – –6 0 8538SDG12 ppppppppppppppp 8538SDG32 ppppppppppppppp 8538SDA (4) 2 ppppppppppppppp 8538SDA (5) 2 ppppppppppppppp – – – – 15 11 15 11 30 8538SDG16 ppppppppppppppp 8538SDG36 ppppppppppppppp 8538SDA (4) 6 ppppppppppppppp 8538SDA (5) 6 ppppppppppppppp – – – – 25 18.5 25 18.5 60 8538SDG14 ppppppppppppppp 8538SDG34 ppppppppppppppp 8538SDA (4) 4 ppppppppppppppp 8538SDA (5) 4 ppppppppppppppp 3 20 15 25 18.5 – – – – 100 8538SEG15 ppppppppppppppp 8538SEG35 ppppppppppppppp 8538SEA (4) 5 ppppppppppppppp 8538SEA (5) 5 ppppppppppppppp – – – – 50 37 50 37 100 8538SEG13 ppppppppppppppp 8538SEG33 ppppppppppppppp 8538SEA (4) 3 ppppppppppppppp 8538SEA (5) 3 ppppppppppppppp 25 18,5 30 22 – – – – 200 8538SEG12 ppppppppppppppp 8538SEG32 ppppppppppppppp 8538SEA (4) 2 ppppppppppppppp 8538SEA (5) 2 ppppppppppppppp 4 40 30 50 37 – – – – 200 8538SFG15 ppppppppppppppp 8538SFG35 ppppppppppppppp 8538SF A (4) 5 ppppppppppppppp 8538SF A (5) 5 ppppppppppppppp – – – – 100 75 100 75 200 8538SFG13 ppppppppppppppp 8538SFG33 ppppppppppppppp 8538SF A (4) 3 ppppppppppppppp 8538SF A (5) 3 ppppppppppppppp 5 75 55 100 75 – – – – 400 8538SGG15 ppppppppppppppp 8538SGG35 ppppppppppppppp 8538SGA (4) 5 ppppppppppppppp 8538SGA (5) 5 ppppppppppppppp – – – – 200 150 200 150 400 8538SGG13 ppppppppppppppp 8538SGG33 ppppppppppppppp 8538SGA (4) 3 ppppppppppppppp 8538SGA (5) 3 ppppppppppppppp 6 150 110 200 150 – – – – 600 8538SHG13 ppppppppppppppp 8538SHG33 ppppppppppppppp 8538SHA (4) 3 ppppppppppppppp 8538SHA (5) 3 ppppppppppppppp – – – – 400 300 400 300 600 8538SHG12 ppppppppppppppp 8538SHG32 ppppppppppppppp 8538SHA (4) 2 ppppppppppppppp 8538SHA (5) 2 ppppppppppppppp (1) Standard control circuit v oltages: Volts 24 110 120 208 220 240 380 440 480 600

50 Hz – V02 – – V03 – V05 V06 – –

60 Hz V01 (6)(7) – V02 (6) V08 – V03 – – V06 V07

For 24 V and 120 V coils add the letter “S” f or separate control. Example: 8538SBG12 V01S. (2) F or optional F or ms, please consult y our nearest Square D/Schneider Electric sales office. (3) Add the letter “H” for Solid State Overload Relays , see table on page opposite. (4) T o order a unit with external reset, replace (4) with “2”. T o order a unit without exter nal reset, replace (4) with “1”. (5) T o order a unit with external reset, replace (5) with “4”. T o order a unit without exter nal reset, replace (5) with “3”. (6) T o order this voltage code, add the letter “ S” (separ ate contol). (7) 24 V coil not a vailable for siz es 4 to 6. A vailab le for sizes 0 to 3, specify letter “S” (separate contol). F or additional infor mation, ref erence catalog 8538CT9701.

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/33 Solid state overload Relays Form adders Motor Logic® solid state relays For use Curren t Description Suffix to be added with rang e to the star ter catalog number(9) 8538SpppppG 1ppppp/SpppppA 1ppppp/SpppppA 2ppppp (8) Base unit, Trip Class 10 H10 (except 8538 SDG16/SDA16/SD A26) (8) Base unit, Trip Class 20 H20 (8) Feature unit H30 8538SBG12/13, 3–9 A Base unit, Trip Class 10 H109 8538SBA12/22/13/23, 3–9 A Base unit, Trip Class 20 H209 8538SCG12/14, 1.5–4.5 A F eature unit H308 8538SCA12/22/14/24, 3–9 A Feature unit H309 8538SDG16, 8538SDA16/26 8538SCG12/14 6–18 A Base unit, Trip Cl ass 10 H100 8538SCA12/22/14/24, 6–18 A Base unit, Trip Cl ass 20 H200 8538SDG16 6–18 A Feature unit H300 8538SDA16/26 8538SDG16, 9–27 A Base unit, Trip Cl ass 10 H101 8538SDA16/26 9–27 A Base unit, Trip Cl ass 20 H201 9–27 A Feature unit H301 (8) Standard current ranges dependent on star ter size: S i z e 0 0 01 234 5 6 7 Current ranges A 3–9 6–18 9–27 15–45 30–90 45–135 90–270 180–540 (10) 270–810 (11) (9) Example: 8538SBG12V01H10. (10) Only av ailable with feature units. (11) Only available with f eature units with auxiliar y contact. For additional inform ation, reference catalog 9065CT9701. NEMA Type

For other versions, please consult with your localSchneider Electric/ Square D sales office: visit www.us.telemanique.com.5/34 Combination starters Mag-Gard® circuit-breaker starters NEMA 1 general purpose enclosure NEMA Type (1) Standard control circuit v oltages: Volts 24 110 120 208 220

60 Hz V01 (4 )( 5 )– V02 (4) V08 –

For 24 V and 120 V coils add the letter “S” for separate control. Example: 8539SCG41V02H10S. Type 3-pole circuit breaker starters, non-reversing Characteristics NEMA Standard power ratings Cir cuit-breaker Basic catalog number complete with code indicating siz e of 3-phase motors 50/60 Hz contr ol circuit voltage (1), optional Forms (2) and “H” code (3) Motor voltage (star ter voltage) 1 0.75 1 0.75 3 2.2 3 2.2 GJL 36007 MO2 8539SBG42 ppppppppppppppp 3 2.2 3 2.2 5 3.7 5 3.7 GJL 36015 MO3 8539SBG43 ppppppppppppppp 1 0.75 1 0.75 3 2.2 3 2.2 GJL 36007 MO2 8539SCG42 ppppppppppppppp 5 3.7 7.5 5.5 10 7.5 – – GJL 36030 MO4 8539SCG44 ppppppppppppppp 7.5 5.5 – – – – – – GJL 36050 MO5 8539SCG45 ppppppppppppppp 5 3.7 7.5 5.5 15 11 20 15 GJL 36030 MO4 8539SDG42 ppppppppppppppp 10 7.5 10 7.5 25 18.5 25 18.5 GJL 36050 MO5 8539SDG43 ppppppppppppppp – – 15 11 – – – – GJL 36075 MO6 8539SDG44 ppppppppppppppp 3 – – – – 25 18.5 30 22 GJL 36050 MO5 8539SEG41 ppppppppppppppp 25 18.5 30 22 30 22 50 37 F AL 36100 18M 8539SEG42 ppppppppppppppp 4 30 22 – – 75 55 100 75 KAL 36250 25M 8539SFG42 ppppppppppppppp – – 40 30 – – – – KAL 36250 26M 8539SFG43 ppppppppppppppp – – 50 37 100 75 – – KAL 36250 29M 8539SFG44 ppppppppppppppp 5 – – – – – – 125 90 KAL 36250 29M 8539SGG41 ppppppppppppppp 50 37 – – – – 150 110 KAL 36250 30M 8539SGG42 ppppppppppppppp – – 60 45 125 90 – – KAL 36250 31M 8539SGG43 ppppppppppppppp 60 45 75 55 150 110 200 150 LAL 36400 32M 8539SGG44 ppppppppppppppp 75 55 – – – – – – LAL 36400 33M 8539SGG45 ppppppppppppppp – – 100 75 200 150 – – LAL 36400 35M 8539SGG46 ppppppppppppppp 6 – – – – – – 250 185 LAL 36400 35M 8539SHG42 ppppppppppppppp 100 75 – – 250 185 300 220 LAL 36400 36M 8539SHG43 ppppppppppppppp 125 90 150 110 300 220 400 300 MAL 36600 40M 8539SHG44 ppppppppppppppp 150 110 – – 350 250 – – MAL 36600 42M 8539SHG45 ppppppppppppppp – – 200 150 400 300 – – MAL 36600 44M 8539SHG46 ppppppppppppppp 7 – – – – – – 500 370 MAL 36800 44M 8539SJG41 ppppppppppppppp – – 250 185 500 370 600 450 MAL 36800 45M 8539SJG42 ppppppppppppppp – – 300 220 600 450 – – MAL 361000 47M 8539SJG43 ppppppppppppppp (2) F or optional F or ms, please consult y our nearest Schneider Electric/Square D sales office. (3) Add the letter “H” for Motor Logic® solid state overload relays, see page 1-30. Motor Logic ® PLUS solid state o verload relays are not available on combination star ters. (4) F or this voltage code, add the letter “S” (separate contol). (5) 24 V coil not a vailable for siz es 4 to 6. A vailab le for sizes 0 to 3, specify letter “S” (separate contol). For additional inform ation, ref erence catalog 8538CT9701.

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/35 Thermal-magnetic circuit-breaker starters NEMA 1 general purpose enclosure (1) Standard control circuit voltages: Volts 24 110 120 208 220

60 Hz V01 (4 )(5) – V02 (4 ) V08 –

For 24 V and 120 V coils add the letter “S” for separate control. Example: 8539SBG1V02H10S. Type 3-pole thermal-magnetic circuit-breaker starters, non-reversing Characteristics NEMA Standard power ratings Circu it-breaker Basic catalog n umber complete with code indicating size of 3-phase motors 50/60 Hz control circuit v oltage (1), optional Forms (2) and “H “code (3) Motor voltage (starter voltage)

200 V (208 V) 230 V (240 V) 460 V (480 V) 575 V (600 V) Type Current rating

0 2 1.5 2 1.5 – – – –F A L 1 5 8539SBG1 ppppppppppppppp – – – – 5 3.7 5 3.7 FAL 15 8539SBG2 ppppppppppppppp 3 2.2 3 2.2 – – – –F A L 2 0 8539SBG3 ppppppppppppppp 1 5 3.7 – – – – – –F A L 3 5 8539SCG5 ppppppppppppppp 7.5 5.5 – – – – – –F A L 5 0 8539SCG2 ppppppppppppppp – – 5 3.7 – – – –F A L 3 0 8539SCG1 ppppppppppppppp – – 7.5 5.5 – – – –F A L 4 5 8539SCG6 ppppppppppppppp – – – – 7.5 5.5 10 7.5 FAL 20 8539SCG3 ppppppppppppppp – – – – 10 7.5 – –F A L 2 5 8539SCG7 ppppppppppppppp – – – – – – 7.5 5.5 FAL 15 8539SCG8 ppppppppppppppp 2 10 7.5 10 7.5 – – – –F A L 6 0 8539SDG1 ppppppppppppppp – – 15 11 – – – –F A L 8 0 8539SDG7 ppppppppppppppp – – – – 7.5 5.5 – –F A L 2 0 8539SDG3 ppppppppppppppp – – – – 20 15 25 18,5 FAL 60 8539SDG4 ppppppppppppppp – – – – 25 18,5 – –F A L 7 0 8539SDG5 ppppppppppppppp – – – – – – 15 11 FAL 35 8539SDG8 ppppppppppppppp – – – – – – 20 15 FAL 45 8539SDG9 ppppppppppppppp 3 15 11 20 15 40 30 50 37 FAL 90 8539SEG3 ppppppppppppppp 20 15 25 18.5 50 37 – – FAL 100 8539SEG1 ppppppppppppppp 25 18.5 30 22 – – – – KAL 110 8539SEG5 ppppppppppppppp – – – – 30 22 40 30 FAL 80 8539SEG6 ppppppppppppppp – – – – – – 30 22 FAL 60 8539SEG4 ppppppppppppppp 4 30 22 – – 75 55 – – KAL 125 8539SFG3 ppppppppppppppp 40 30 50 37 100 75 – – KAL 200 8539SFG4 ppppppppppppppp – – 40 30 – – 100 75 KAL 150 8539SFG1 ppppppppppppppp – – – – 60 45 75 55 KAL 110 8539SFG5 ppppppppppppppp – – – – – – 60 45 FAL 100 8539SFG6 ppppppppppppppp 5 50 37 – – – – 150 110 LAL 200 8539SGG6 ppppppppppppppp 60 45 75 55 150 110 200 150 LAL 250 8539SGG1 ppppppppppppppp 75 55 – – – – – – LAL 300 8539SGG4 ppppppppppppppp – – 60 45 125 90 – – LAL 225 8539SGG3 ppppppppppppppp – – 100 75 200 150 – – LAL 350 8539SGG2 ppppppppppppppp – – – – – – 125 90 KAL 200 8539SGG7 ppppppppppppppp 6 100 75 125 90 250 185 300 220 MAL 450 8539SHG4 ppppppppppppppp 125 90 150 110 300 220 400 300 MAL 600 8539SHG3 ppppppppppppppp 150 110 – – 350 250 – – MAL 600 8539SHG5 ppppppppppppppp – – 200 150 400 300 – – MAL 800 8539SHG7 ppppppppppppppp – – – – – – 250 185 MAL 250 8539SHG6 ppppppppppppppp – – – – – – 350 250 MAL 500 8539SHG2 ppppppppppppppp 7 – – 250 185 500 370 600 450 MAL 900 8539SJG2 ppppppppppppppp – – 300 220 600 450 – – MAL 1000 8539SJG3 ppppppppppppppp – – – – – – 500 370 MAL 800 8539SJG1 ppppppppppppppp (2) For optional F orms, please consult your nearest Schneider Electric/Square D sales office . (3) Add the letter “H” f or Motor Logic® solid state over load relays , see page 5/30. Motor Logic® PLUS solid state overload rela ys are not av ailable on combination star ters. (4) For this voltage code , add the letter “S” (separ ate contol). (5) 24 V coil not availab le for sizes 4 to 6. Available for sizes 0 to 3, specify letter “S” (separate contol). For additional in formation, ref erence catalog 8538CT9701. NEMA Type

For other versions, please consult with your localSchneider Electric/ Square D sales office: visit www.us.telemanique.com.5/36 Solid State Overload Relays Motor Logic® Base units NEMA Type Type Base units Base units for retrofit for separate mounting to Type S starters (2) NEMA Size Full load T ype Catalog n umber Catalog n umber 3-phase current rang e 00C (1) 3–9 A T r ip Class 10 9065SSC10 9065SSC10 T rip Class 20 9065SSC20 9065SSC20 0 (1) 6–18 A T rip C lass 10 9065SS010 9065SS010 T rip Class 20 9065SS020 9065SS020 1 (1) 9–27 A T rip C lass 10 9065SS110 9065SS110 T rip Class 20 9065SS120 9065SS120 2 15–45 A T rip C lass 10 9065SS210 9065SR210 T rip Cass 20 9065SS220 9065SR220 3 30–90 A T rip C lass 10 9065SS310 9065SR310 T rip Class 20 9065SS320 9065SR320 4 45–135 A T rip C lass 10 9065SS410 9065SR410 T rip Cass 20 9065SS420 9065SR420 Motor Logic feature units Type Feature units Feature units for separate mounting for retrofit to Type S starters (2) NEMA Size Full load T ype Catalog n umber Catalog no. 3-phase current rang e 00B (1) 1.5–4.5 A T ri p Class 10/20 9065SFB20 9065SFB20 00C (1) 3–9 A T rip Class 10/20 9065SFC20 9065SFC20 0 (1) 6–18 A T ri p Class 10/20 9065SF020 9065SF020 1 (1) 9–27 A T ri p Class 10/20 9065SF120 9065SF120 2 15–45 A T rip Class 10/20 9065SF220 9065ST220 3 30–90 A T rip Class 10/20 9065SF320 9065ST320 4 45–135 A T rip Cl ass 10/20 9065SF420 9065ST420 5 (3) 90–270 A T rip Cl ass 10/20 – 9065ST520 6(3) 180–540 A T ri p Class 10/20 – 9065ST620 7 (3) 270–810 A T ri p Class 10/20 – 9065ST720 (1) F or power connection kit, see tab le on page opposite. (2) F or Type S star ter catalog numbers , see page 5/30. (3) Replacement f or existing T ype S star ters with an existing Motor Logic® solid state overl oad relay. Does not include primary current tr ansformer or additional components. F or additional infor mation, ref erence catalog 9065CT9701.

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/37 Motor Logic PLUS programmable units Type Base units for separate mounting NEMA Size Cu rrent Voltage Catalog number 3-phase rang e AV 0 0.5–2.3 200–480 9065SPB4 600 9065SPB6 0 2–9 200–480 9065SPC4 600 9065SPC6 1 6–27 200–480 9065SP14 600 9065SP16 2 10–45 200–480 9065SP24 600 9065SP26 3 20–90 200–480 9065SP34 600 9065SP36 4 (1) 60–135 200–480 9065SP44 600 9065SP46 5 (2) 120–270 200–480 9065SP54 600 9065SP56 6 (3) 240–540 200–480 9065SP64 600 9065SP66 (1) Size 4 requires the use of an exter nal current transf or mer . Ratio of 150:5 recommended. (2) Size 5 requires the use of an exter nal current transf or mer . Ratio of 300:5 recommended. (3) Size 6 requires the use of an exter nal current transf or mer . Ratio of 600:5 recommended. Accessories Type Power connection kits Type Description For use on Catalog n umber Lug connector For separate mounting 9065 S p (Sizes 00B/00C/0/1) 9999LLO kits For mounting on 9065 S p (Sizes 00B/00C/0/1) 9999LBO T ype S star ters For additional inform ation, reference catalog 9065CT9701. NEMA Type

For other versions, please consult with your localSchneider Electric/ Square D sales office: visit www.us.telemanique.com.5/38 Definite purpose contactors Compact contactors, single-pole and 2-pole NEMA Type Type Compact contactors Compact contactors single-pole 2-pole (3) Full Loc ked rotor Resistive Motor po wer N.O . poles Basic catalog number Basic catalog number load current load 115 V 230 V 230 V460/575 V com plete with code complete with code current 277 V 480 V 575 V current single-phase single-phase 3-phase 3-phase indicating control indicating control circuit v oltage (1) circuit voltage (1) AA A A A Hp kW Hp kW Hp kW Hp kW 20 100 100 80 25 1 0.7 5 2 1.5 – – – –1 o r 2 8910DP11 ppppppppppppppp 8910DP12 ppppppppppppppp 25 125 125 100 30 2 1.5 3 2.2 – – – –1 o r 2 8910DP21 ppppppppppppppp 8910DP22 ppppppppppppppp 30 150 150 120 40 2 1.5 (1) (1) – – – –1 o r 2 8910DP31 ppppppppppppppp 8910DP32 ppppppppppppppp 40 240 200 160 50 (2) 2 1.5 5 3.7 – – – –1 o r 2 8910DP41 ppppppppppppppp 8910DP42 ppppppppppppppp (1) 3 hp (2.2 kW) f or 1-pole device; 5 hp (3.7 kW) f or 2-pole de vice. 2, 3 and 4-pole, contactors Type 2, 3 and 4-pole, contactors (3) Full Loc ked rotor Resistive Motor po wer N.O . poles Basic catalog number load current load 115 V 230 V 230 V460/575 V complete with code indicating current 277 V 480 V 575 V current single-phase single-phase 3-phase 3- phase contr ol circuit v oltage (1) AA A A A Hp kW Hp kW Hp kW Hp kW 3 8910DP A13 ppppppppppppppp 4 8910DP A14 ppppppppppppppp 3 8910DP A23 ppppppppppppppp 4 8910DP A24 ppppppppppppppp 30 180 150 120 40 2 1.5 5 3.7 10 7.5 15 11 2 8910DP A32 ppppppppppppppp 3 8910DP A33 ppppppppppppppp 4 8910DP A34 ppppppppppppppp 40 240 200 160 50 3 2.2 7.5 5.5 10 7.5 20 15 2 8910DP A42 ppppppppppppppp 3 8910DP A43 ppppppppppppppp 4 8910DP A44 ppppppppppppppp 50 300 250 200 62 3 2.2 10 7.5 15 11 30 22 2 8910DP A52 ppppppppppppppp 3 8910DP A53 ppppppppppppppp 60 360 300 240 75 5 3.7 10 7.5 25 18.5 30 22 2 8910DP A62 ppppppppppppppp 3 8910DP A63 ppppppppppppppp 75 450 375 300 94 5 3.7 15 11 25 18.5 40 30 2 8910DP A72 ppppppppppppppp 3 8910DP A73 ppppppppppppppp 90 540 450 360 120 7.5 5.5 20 15 30 22 50 37 2 8910DP A92 ppppppppppppppp 3 8910DP A93 ppppppppppppppp 120 720 600 480 120 10 7.5 25 18.5 40 30 75 55 2 8910DP A122 ppppppppppppppp 3 8910DP A123 ppppppppppppppp F or additional infor mation, ref erence catalog 8910CT9301R6/97.

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/39 4-pole contactors Type 4-pole contactors with 2 N.O. and 2 N.C. poles Full Locked rotor Resistive Motor power N.O. N .C. Basic catalog number load current load 115 V 230 V 230 V460/575 V poles poles complete with code indicating current 277 V 480 V 575 V current single-phase single-phase 3- phase 3-phase (3) (7) control circuit v oltage (1) A AAA A Hp kW Hp kW Hp kW Hp kW 30 180 150 120 40 2 1.5 5 3.7 10 7.5 15 11 2 2 8910DPA34 ppppppppppppppp Y392 40 240 200 160 50 3 2.2 7.5 5.5 10 7.5 20 15 2 2 8910DPA44 ppppppppppppppp Y392 Accessories Type External auxiliary contacts For use on Description Catalog number 8910DP A 1 N.O. contact 9999D10 1 N.C. contact 9999D01 1 N.O. and 1 N.C. contacts 9999D11 2 N.O. contacts 9999D20 8910DP A122/123 1 N.O. contact 9999SX6 1 N.C. contact 9999SX7 1 N.O. and 1 N.C. isolated contacts 9999SX8 1 N.O. o verlapping contact 9999SX9 1 N.C. over lapping contact 9999SX10 (1) Standard control circuit voltages for 8910DP/DP A : Volts 24 110 120 208-240 220 277 440 480 550 600

50 Hz V14 V02 – – V09 – V06 (4) – V07 (5) –

60 Hz V14 – V02 V09 – V04 – V06 (4) – V07 (5)

Standard control circuit voltage for 8910DP A122/DPA123: Volts 24 110 120 208 220 230-240 440 480 550 600

50 Hz V12 V02 – – V03 – V06 – V07 –

60 Hz V01 (6) – V02 V08 – V03 – V06 – V07

(2) 50 A resistive limited to 277 V (singl e pole device only). All other contactors r ated 40 A resistiv e (above 277 V). (3) Above 240 V, all li nes m ust be switched. (4) Not available for type 8910DP11 to 8910DP31 single-pole devices . (5) Not availab le for type 8910DP single and 2-pole de vices . (6) Only availab le on types 8910DP A122/DPA123. For additional information, reference catalog 8910CT9301R6/97. NEMA Type

For other versions, please consult with your localSchneider Electric/ Square D sales office: visit www.us.telemanique.com.5/40 Lighting contactors Multipole contactors Types L and LX NEMA Type Type Multipole contactors, open style, Multipole contactors, open style, electrically held (2) mechanically held (2) Thermal operating Number of poles (3) Basic catalog number complete with code Basic catalog number complete with code current (A) indicating contr ol circuit v oltage (1) indicating contr ol circuit voltage (1) 20 2 8903LO20 ppppppppppppppp 8903LXO20 ppppppppppppppp 3 8903LO30 ppppppppppppppp 8903LXO30 ppppppppppppppp 4 8903LO40 ppppppppppppppp 8903LXO40 ppppppppppppppp 6 8903LO60 ppppppppppppppp 8903LXO60 ppppppppppppppp 8 8903LO 80 ppppppppppppppp 8903LXO80 ppppppppppppppp 10 8903LO1000 ppppppppppppppp 8903LXO1000 ppppppppppppppp 12 8903LO1200 ppppppppppppppp 8903LXO1200 ppppppppppppppp Multipole contactors Type S (1) Standard control circuit v oltages: Volts 24 (4) 110 120 208 220

60 Hz V01 – V02 V08 –

50 Hz – – V06 –

60 Hz V03 V04 – V06

For Forms and kits, please consult y our nearest Square D/Schneider Electr ic sales office . Type Multipole contactors, open style, Multipole contactors, open style, electrically held (2) mechanically held (2) Thermal operating Number of poles Basic catalog number complete with code Basic catalog number complete with code current (A) indicating contr ol circuit v oltage (1) indicating contr ol circuit voltage (1) 30 2 8903SMO1 ppppppppppppppp 8903SMO10 ppppppppppppppp 3 8903SMO2 ppppppppppppppp 8903SMO11 ppppppppppppppp 4 8903SMO3 ppppppppppppppp 8903SMO12 ppppppppppppppp 5 8903SMO4 ppppppppppppppp 8903SMO13 ppppppppppppppp 60 2 8903SPO1 ppppppppppppppp 8903SPO10 ppppppppppppppp 3 8903SPO2 ppppppppppppppp 8903SPO11 ppppppppppppppp 4 8903SPO3 ppppppppppppppp 8903SPO12 ppppppppppppppp 5 8903SPO4 ppppppppppppppp 8903SPO13 ppppppppppppppp 100 2 8903SQO1 ppppppppppppppp 8903SQO10 ppppppppppppppp 3 8903SQO2 ppppppppppppppp 8903SQO11 ppppppppppppppp 4 8903SQO3 ppppppppppppppp 8903SQO12 ppppppppppppppp 5 8903SQO4 ppppppppppppppp 8903SQO13 ppppppppppppppp 200 2 8903SV O1 ppppppppppppppp 8903SV O10 ppppppppppppppp 3 8903SV O2 ppppppppppppppp 8903SV O11 ppppppppppppppp 4 8903SV O3 ppppppppppppppp 8903SV O12 ppppppppppppppp 5 8903SV O4 ppppppppppppppp – 300 2 8903SXO1 ppppppppppppppp 8903SXO13 ppppppppppppppp 3 8903SXO2 ppppppppppppppp 8903SXO14 ppppppppppppppp 400 (5) 2 8903SY O1 ppppppppppppppp 8903SY O16 ppppppppppppppp 3 8903SY O2 ppppppppppppppp 8903SY O17 ppppppppppppppp 600 (5) 2 8903SZO1 ppppppppppppppp 8903SZO18 ppppppppppppppp 3 8903SZO2 ppppppppppppppp 8903SZO19 ppppppppppppppp 800 (5) 2 8903SJO1 ppppppppppppppp 8903SJO10 ppppppppppppppp 3 8903SJO2 ppppppppppppppp 8903SJO11 ppppppppppppppp (2) All lighting contactors are provided with separate control as standard, exc ept electrically held 400, 600 and 800 A de vices . Electrically held 400, 600 and 800 A device s are provided with common control. Versions are a vailab le with up to 12 N.C. poles (factory only). (4) 24 V coils are not availab le for 200–800 A de vices. (5) F orm F4T is provided as standard on electrically held devices 400–800 A; include line voltage when ordering. Control v oltage is 120–60. F or 400–800 A devices—must specify line v oltage, not control voltage. For additional information, reference catalog 8903CT9701.

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/41 Manual starters and switches Manual starters Type F, general purpose surface mounting enclosure (NEMA 1) Type Single units, Single units, standard starters starters with handle padlockable in the ‘O’ position Type of Number M aximum power Maximum Featu res Catalog number Catalog n umber operator of poles of single-phase motors continuous 115-230 Vac 115-230 Vdc 277 V ac current Hp kW Hp kW Hp kW A Toggle 1 1 0.75 - - 1 0.75 16 St andard 2510FG1 2510FG5 operator With red pilot light 2510FG1P 2510FG5P (1) 2 1 0.75 0.75 0.55 1 0.75 16 St andard 2510FG2 2510FG6 With red pilot light 2510FG2P 2510FG6P Removable 1 1 0.75 - - 1 0.75 16 St andard 2510FG3 – key With red pilot light 2510FG3P – (1) 2 1 0.75 0.75 0.55 1 0.75 16 St andard 2510FG4 – With red pilot light 2510FG4P – Type Duplex units, Duplex units, 1 starter 2 starters in duplex enclosure in one enclosure Type of Number M aximum power Maximum Featu res Catalog number Catalog n umber operator of poles of single-phase motors continuous 115-230 Vac 115-230 Vdc 277 V ac current Hp kW Hp kW Hp kW A Toggle 2 (3) 1 0.75 0.75 0.55 1 0.75 16 St andard 2510FG02 2510FG22 operator With red pilot light 2510FG02P 2510FG22P (1) (2) Removable 2 (3) 1 0.75 0.75 0.55 1 0.75 16 With red pilot light 2510FG04P 2510FG44P key (1) (2) Type Duplex units, starters with “AUTO-OFF-HAND” selector switch T ype of Number M aximum power Maxim um Features Catalog number operator of poles of single-phase motors continuous 115-230 Vac 115-230 Vdc 277 V ac current Hp kW Hp kW Hp kW A Toggle 1 1 0.75 - - 1 0.75 16 St andard 2510FG71 operator With red pilot light 2510FG71P (1) 2 1 0.75 0.75 0.55 1 0.75 16 St andard 2510FG72 With red pilot light 2510FG72P Removable 2 1 0.75 0.75 0.55 1 0.75 16 With red pilot light 2510FG74P ke y (1) (1) One ther mal unit is required (2) For tw o starters in one enclosure, two ther mal units are required. (3) Two poles for each star ter. For additional inform ation, reference catalog 2570CT9701. NEMA Type

For other versions, please consult with your localSchneider Electric/ Square D sales office: visit www.us.telemanique.com.5/42 Manual starters and switches Manual switches Type K, in general purpose surface mounting enclosure (NEMA 1) NEMA Type Type Non-reversing T ype of No. of Maximum motor power s Max. continuous Catalog n umber operator poles 115 Vac 230 Vac 460 Vac 575 Vac 90 Vdc 115 Vdc 230 Vdc current Hp kW Hp kW Hp kW Hp kW Hp kW Hp kW Hp kW A Features (1) With red pilot light. F or additional infor mation, ref erence catalog 2510CT9701.

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/43 Manual switches Types T and M, in general purpose surface mounting enclosure (NEMA 1) Type Non-reversing Type of No. of NEMA Size R atings Catalog number operator poles Motor voltage Max. power DC 3-phase Single-phase V Hp kW Hp kW Hp kW Toggle operator AC 2 M-0 115 – – – – 1 0.75 2510TBG1 230 – – – – 2 1.5 M-1 115 – – – – 2 1.5 2510TCG1 230 – – – – 3 2.2 M-1P 115 – – – – 3 2.2 2510TCG2 230 – – – – 5 3.7 AC 3 M-0 200–230 – – 3 (2) 2.2 (2) – – 2510TBG2 DC 2 M-0 115 1 0.75 – – – – 2510TBG4 M-1 115 1.5 1.1 – – – – 2510TCG5 230 2 1.5 – – – – Push button AC 2 M-0 115 – – – – 1 0.75 2510MBG1 230 – – – – 2 1.5 M-1 115 – – – – 2 1.5 2510MCG1 230 – – – – 3 2.2 M-1P 115 – – – – 3 2.2 2510MCG2 230 – – – – 5 3.7 AC 3 M-0 200–230 – – 3 (2) 2.2 (2) – – 2510MBG2 DC 2 M-0 115 1 0.75 – – – – 2510MBG4 M-1 115 1.5 1.1 – – – – 2510MCG5 230 2 1.5 – – – – (2) Value for 230 V. (3) Value for 575 V. For additional inform ation, reference catalog 2510CT9701. NEMA Type

For other versions, please consult with your localSchneider Electric/ Square D sales office: visit www.us.telemanique.com.5/44 Accessories Replacement parts kits NEMA Type Type Replacement parts kits Description For use with Number of poles Catalog n umber NEMA Siz e in the kit Class T ype or current Replacement parts kits 8502, 8536, 8538, SA (Series B) 00 3 9998SJ1 (the kit contains the moving and 8539, 8702, 8736 SB 0 3 9998SL2 stationary contacts, contact 4 9998SL12 springs and necessar y hardware) SB , SC (po wer pole adder) 0 and 1 1 9998SL22 SC 1 and 1P 3 9998SL3 14 9998SL13 SD 2 3 9998SL4 4 9998SL14 SD (power pole adder) 2 1 9998SL24 SE 3 2 9998SL6 3 9998SL7 SF 4 2 9998SL8 3 9998SL9 SG 5 2 9998SL10 3 9998SL11 SH 6 2 9998SL25 3 9998SL26 SJ 7 2 9998SL30 3 9998SL31

8903 L (Ser ies C) and LX (Series B) 20 A 4 9998RA5B

8910 DP A 1 ppppp 20 A 1 9998DRC1

DPA 2ppppp 25 A 1 9998DRC2 DPA 3ppppp 30 A 1 9998DRC3 DPA 4ppppp 40 A 1 9998DRC4 DPA 5ppppp 50 A 1 9998DRC5 DPA 6ppppp 60 A 1 9998DRC6 DPA 7ppppp 75 A 1 9998DRC7 DPA 9ppppp 90 A 1 9998DRC9 DP A 123 120 A 1 9998DRC12 F or additional infor mation, ref erence catalog 8502CT9701.

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/45 External auxiliary contacts Type External contact kits Description For use with Type of contact Catalog number Class T ype NEMA size or current External conver tible contact kits 8502, 8702, SA to SJ 00 to 7 1 N.O. contact 9999SX6 8536, 8736 1 N. C . contact 9999SX7 8903 (T ype S only) SM to SJ 30–800 A 2 isolated contacts 1 N.O. and 1 N.C.9999SX8 1 N.O. overlapping contact 9999SX9 (1) 1 N.C. overlapping contact 9999SX10 (1) External non-convertible contact kits 8502, 8702, SA to SJ 00 to 7 1 N.O. contact 9999SX13 8536, 8736 1 N.C . contact 9999SX14 8903 (T ype S only) SM to SJ 30–800 A 2 isolated contacts 1 N.O. and 1 N.C.9999SX15 1 N.O. overlapping contact 9999SX16 (1) 1 N.C. overlapping contact 9999SX17 (1) (1) These products must be used together and must be mounted on the same side of the contactor. They are suitable for applications where it is necessary for a N.O. contact to overlap a N.C. contact. External auxiliary contacts Type External auxiliary contacts Description For use with Type of contact Catalog number Class Type External auxiliary contacts 8910 DPA 1 N.O. contact 9999D10 1 N.C . contact 9999D01 2 isolated contacts 1 N.O . and 1 N.C. 9999D11 2 N.O. contacts 9999D20 DPA122/123 1 N.O. contact 9999SX6 1 N.C . contact 9999SX7 2 isolated contacts 1 N.O . and 1 N.C. 9999SX8 1 N.O. overlapping contact 9999SX9 1 N.C. overlapping contact 9999SX10 For additional inform ation, reference catalog 8502CT9701. NEMA Type

For other versions, please consult with your localSchneider Electric/ Square D sales office: visit www.us.telemanique.com.5/46 Industrial control relays AC relays NEMA Type (1) Standard A C control circuit voltages: Volts 24 110 120 208 220

50 Hz V12 V02 – – V03

50 Hz – V06 – V07 –

60 Hz V03 – V06 – V07

Example: 8501XO20 V02. AC Control relay AC Latching relay Continuous Load Rating Normally O pen Convertible Basic catalog n umber complete with code Basic cata log number complete with code Inductive / resistive Instantaneous Contacts indi cating contr ol circuit v oltage (1) indicating contr ol circuit voltage (1)

10 A / 10 A 0 8501XO00 ppppppppppppppp –

2 8501XO20 ppppppppppppppp 8501XO20XL ppppppppppppppp 3 8501XO30 ppppppppppppppp 8501XO30XL ppppppppppppppp 4 8501XO40 ppppppppppppppp 8501XO40XL ppppppppppppppp 6 8501XO60 ppppppppppppppp 8501XO60XL ppppppppppppppp 8 8501XO80 ppppppppppppppp 8501XO80XL ppppppppppppppp 10 8501XO1000 ppppppppppppppp – 12 8501XO1200 ppppppppppppppp – A maxim um of 8 N.C. contacts is allowed on 9–12 pole relays . the application requires to use as a coil clearing contact. DC relays DC Control relay DC Latching relay Continuous Load Rating Normally O pen Convertible Basic catalog n umber complete with code Basic cata log number complete with code Inductive / resistive Instantaneous Contacts indi cating contr ol circuit v oltage (2) indicating contr ol circuit voltage (2)

5 A / 5 A 0 8501XDO00 ppppppppppppppp –

2 8501XDO20 ppppppppppppppp 8501XDO20XDL ppppppppppppppp 4 8501XDO40 ppppppppppppppp 8501XDO40XDL ppppppppppppppp 6 8501XDO60 ppppppppppppppp 8501XDO60XDL ppppppppppppppp 8 8501XDO80 ppppppppppppppp 8501XDO80XDL ppppppppppppppp the application requires to use as a coil clearing contact. F or additional infor mation, ref erence catalog 8501CT9601. (2) Standard DC contro l circuit voltages: V olts 12 24 48 72 V51 V53 V56 V58 Volts 115 125 230 250 V62 V62 V66 V66 Example: 8501XDO80 V53.

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/47 Circuit breaker operating mechanisms Door mounted kits Complete kit Std. shaft /std. handle Long shaft /std. handle Long shaft / short handle Does not include circuit breaker Includes: Includes: Inc ludes: Operating mechanism Operating mechanism Operating mechanism Standard 6" handle Standard 6" handle Short 3" handle Use with: Standard shaft kit Long shaft kit Long shaft kit Circuit breaker Number Frame C atalog Mounting depth Catalog Mounting depth Catalog Mounting depth GJL 3 75, 100 9421LG1 5-1/2–10-1/4 9421LG4 5-1/2–20-7/8 9421LG3 5-1/2–20-7/8 FAL, FCL, FHL 2–3 100 9421LN1 5-1/2–10-7/16 9421LN4 5-1/2–21 9421LN3 5-1/2–21 KAL, KCL, KHL 2–3 250 9421LP1 6-1/4–11-3/16 9421LP4 6-1/4–21-3/4 9421LP3 6-1/4–21-3/4 LAL, LHL, Q4L 2–3 400 9421LR1 6-5/16–10-7/8 9421LR4 6-5/16–21-1/2 (3) MEL, MXL 2–3 800 9421LT1 (2) 7-3/16–11-5/8 9421L T4 (2) 7-3/16–22-1/4 (3) MAL, MHL 2–3 1000 9421LT1 (2) 7-3/16–11-5/8 9421L T4 (2) 7-3/16–22-1/4 (3) NAL, NCL, NEL, NXL 2–3 1200 9421LX1 (2) 8-1/4–12-3/4 9421LX4 (2) 8-1/4–23-3/8 (3) Merlin Gerlin® NSF, Powerpact D, H and J Circuit Breakers MG-NSF , 3 250 9421LJ1 5-1/2–10-3/4 9421LJ4 5-1/2–21-3/8 (3) Powerpact D , H and J (1) Mounting depth measured from circuit breaker mounting surface (control panel) to outside of enclosure door in inches. (2) Types L T1, L T4, LX1, and LX4 include an 8" handl e rather than a 6" handle. (3) 3" handles are not recommended for use with these circuit breakers . Handles Use With Standard Handle Assemblies Special 3'' Version Circuit breaker Number Frame Type T ype Type Type T ype Type or interrupter type of poles siz e (A) 1, 3R, 12 3R, 4 3R, 4, 4X 1, 3R, 12 3R, 4 3R, 4, 4X (Painted) (P ainted) (Chrome Plated) (Painted) (P ainted) (Chrome Plated) GJL 3 75 9421LH6 9421LH46 9421LC46 9421LH43 9421LH43 9421LC43 FAL, FCL, FHL 2–3 100 9421LH6 9421LH46 9421LC46 9421LH43 9421LH43 9421LC43 KAL, KCL, KHL 2–3 250 9421LH6 9421LH46 9421LC46 9421LH43 9421LH43 9421LC43 LAL, LHL, Q4L 2–3 400 9421LH6 9421LH46 9421LC46 (3) MEL, MXL 2–3 800 9421LH8 9421LH48 9421LC48 (3) MAL, MHL 2–3 1000 9421LH8 9421LH48 9421LC48 (3) NAL, NCL, NEL, NXL 2–3 1200 9421LH8 9421LH48 9421LC48 (3) (3) 3" handles are not recommended for use with these circuit breakers . For additional inform ation, reference catalog 9420CT9701. Operating Mechanism (includes lockout) NEMA Type

For other versions, please consult with your localSchneider Electric/ Square D sales office: visit www.us.telemanique.com.5/48 Disconnect switches Variable depth and cable operated NEMA Type Disconnect switches Switch for use Variable Fuse clip rating with cable operators depth Maximum horsepower ratings (1) DC (amperes) non- Switch and operatin g ONLY— Switch and operating mec hanism mtg. A C systems v olts Using interchang eable type mec hanism only— does not inc lude and handle mec hanism—overpac ked Disconnect range (Motor volts) 2 poles For Class H, J, K does not include handle mec hanism Includes T ype A1 Inc ludes Type A2 switch min.–max. 208 240 480 600 250 V Fuse or R fuses only handle mechanism or cab le operator handle mechanism handle mechanism siz e (inc hes) (200) (230) (460) (575) max. type 250 V 600 V T ype Type T ype Type 30 A 6-5/8"–18" 7.5 7.5 15 20 5 None — — 9421TCN30 9421TCN30C 9421A TCN301 9421A TCN302 H, K, J , R 30 — 9421TCF30 9421TCF30C 9421A TCF301 9421ATCF302 60 30 9421TCF33 9421TCF33C 9421A TCF331 9421ATCF332

60 A 6-5/8"–18" 15 15 30 50 10 None — — 9421TDN60 9421TDN60C 9421A TDN601 9421ATDN602

H, K, J , R 60 30 9421TDF60 9421TDF60C 9421A TDF601 9421ATDF602 —6 0 9421TDF63 9421TDF63C 9421A TDF631 9421ATDF632

100 A 6-5/8" –18" 25 30 60 75 20 None — — 9421TEN10 9421TEN10C 9421A TEN101 9421ATEN102

H, K, J, R 100 100 9421TEF10 9421TEF10C 9421ATEF101 9421ATEF102

200 A 9-1/8- –19-1/4 (2) 40 60 125 150 40 None — — 9421TF1 — 9421A TF11 9421ATF21

H, K, J, R 200 200 9421TF2 — 9421A TF12 9421ATF22 — 400 9421TF3 (3) — 9421A TF13 (3) 9421ATF23 (3) 400 A 11.38 75 125 250 350 50 None — — 9421TG1 (6)(7) — For handle selection, Fix ed Depth(4) (A5 or A6 Handle) see table below. 400 A 15.87–19 (5) 75 125 250 350 50 H, K, J , R 400 400 9421TG2 (6)(7) — For handle selection, Adj. Depth (4) (A7 or A8 Handle) see table below. (1) Refers to r ating of switch only . (2) 9422 R2 will e xtend maximum mounting depth 7" (3) Accommodates Class J fuses only . (4) Switches are either fixed-depth or adjustable; the handle will determine installation. (5) In steps of 0.63 inches . (6) Commercially available enclosures may not accept type TG operating mechanisms. Contact enc losure man ufacturer f or availability of enclosures f or use with these switches. (7) Right hand flange mounting only . Cable operator and handles Cab le Mechanisms (8) Cab le Mechanisms with A1 Handle for Types 1, 3, 3R, 4 and 12 Disconnect Switc h T ypes Cable Catalog n umber Catalog n umber Switc h Size Length

30 A, 60 A, 100 A TCF , TCN, TDF , TDN, TEF , TEN 36" 9421CFT30 9421CFT31

48" 9421CFT40 – 60" 9421CFT50 9421CFT51 120" 9421CFT10 9421CFT11 (8) Must purchase handle mechanism separately (9422, A1, A2, A3 or A4). Handle NEMA Type Enclosure 1, 3, 3R, 4 (sheet steel), 12 4, 4X (stainless steel) (10) T ype of Handle Catalog n umber Catalog n umber 6" HANDLE (9) 9421A1 9421A2 4" HANDLE (9) 9421A3 9421A4 12" HANDLE (fix ed depth) (11) 9421A5 9421A6 12" HANDLE (v ariable depth) (11) 9421A7 9421A8 10" HANDLE (12) 9421A9 9421A10 (9) F or use with 30–200 Ampere switches and all circuit breaker mechanisms. (10) All e xter nal metal parts are either stainless steel or a chrome-plated non-ferrous die casting. (11) For use with 400 Ampere Type TG1 and TG2 disconnect switches ONL Y. (12) For use with Type D2 remote or dual adaptor kit. For additional inform ation, ref erence catalog 9420CT9701.

For other versions, please consult with your local Schneider Electric/ Square D sales office: visit www.us.telemanique.com. 5/49 Circuit breaker operating mechanisms Flange mounted Use with: Operating mechanism Circuit breaker Number Frame Variable depth Oper ating mechanism onl y — O perating mechanism and handle mechanism frame size of poles size (A) mtg. range (In.) does not include Inc l udes Type A1 (2) Includes Type A2 (2) min.-max. (1) handle mechanism handle mechanism handle mechanism Square D circuit breakers GJL 3 100 6.00–17.75 9422RG1 9422ARG11 9422ARG21 FAL, FHL 2–3 100 5.38–17.75 9422RN1 9422ARN11 9422ARN21 KAL, KHL 2–3 250 6.38–17.88 9422RP1 9422ARP11 9422ARP21 LAL, LHL, Q4L 2–3 400 7.44–18.25 9422RR1 9422ARR11 9422ARR21 MEL, MXL 2–3 800 9.00–18.38 9422R T1 9422ART11 9422ART21 MAL, MHL 2–3 1200 9.00–18.38 9422RT1 9422ART11 9422ART21 NAL, NCL, NEL, NXL 2–3 1200 11.00–18.37 9422RX1 – – Merlin Gerin NSF, NSJ, Powerpact D, Hand J Circuit Breakers MG-NSF , Powerpact D, Hand J 3 250 5.88–17.75 9422RQ1 – – MG-NSJ 3 600 9.00–17.75 9422RS1 – – (1) Class 9422 T ype R2 will extend mounting depth 7 inches. (2) For handle information, see page 5/48. Cable operators Cable operators Circuit breaker No. of Frame siz e Cable length Cable mec hanism Cable mec hanisms with A1 handle type poles for Types 1, 3, 3R, 4, 12 (1) GJL 3 100 36" 9422CGJ30 9422CGJ31 48" 9422CGJ40 9422CGJ41 60" 9422CGJ50 9422CGJ51 120" 9422CGJ10 9422CGJ11 FAL, FHL 2-3 100 36" 9422CF A30 9422CF A31 9422CF A50 9422CF A51 9422CF A10 9422CF A11 KAL, KHL 2-3 250 36" 9422CKA30 9422CKA31 60" 9422CKA50 9422CKA51 120" 9422CKA10 9422CKA11 LAL, LHL, Q4L 2-3 400 36" 9422CLA30 9422CLA31 60" 9422CLA50 9422CLA51 120" 9422CLA10 9422CLA11 MG-NSF , 3 250 36” 9422CSF30 – Powerpact D, 60" 9422CSF50 – Hand J 84" 9422CSF70 – 120" 9422CSF10 – MG-NSF , 4 250 36” 9422CSF304 – Powerpact D, 60" 9422CSF504 – Hand J 120" 9422CSF104 – MG-NSJ 3 600 36” 9422CSJ30 – 60" 9422CSJ50 – 120" 9422CSJ10 – MG-NSJ 4 600 36” 9422CSJ304 – 60" 9422CSJ504 – 120" 9422CSJ104 – For additional inform ation, reference catalog 9420CT9701. NEMA Type