INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.41 18 • Industrial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable 300V Power-Limited Tray Cables — Overview Construction Soft annealed bare or tinned copper with PVC flame retardant insulation and jacket. Other insulation and jacket options are available (see table below). Communication wire included on all multi-pair/multi-triad 1000 and 3000 series part numbers, 22 AWG (7x30) bare copper, orange PVC insulation. Nylon rip cord included in all PVC/PVC instrumentation cables. Other Construction Options: Armoring Capabilities Belden also has the capability to protect electronic, instrumentation and control cables with interlocking or continuous armor and smooth or corrugated protective metal tapes. Application Cable jackets are resistant to sunlight, moisture and vapor penetration. PVC/PVC constructions, with 3 conductors or more and 20 AWG or larger, are suitable for direct burial. Unshielded Twisted non-shielded pairs and triads provide a minimal OD allowing greater tray and conduit fill. Non-shielded instrument pairs may be utilized when recommended by the instrument manufacturer and used in a metallic conduit. Overall Shield Recommended for use in instrumentation applications where signals are transmitted in excess of 100 millivolts except in areas where high voltage and current sources create excessive noise interference. The Beldfoil ® shield with drain wire provides 100% coverage for maximum shield effectiveness. Individually Shielded and Overall Shielded Individually shielded pairs or triads with an overall shield are recommended for use in instrumentation applications where optimum noise rejection is required. Individual pair/triad shields are fully isolated from each other and contain a separate drain wire for grounding, to provide maximum protection from crosstalk and common mode interference. Cables with an overall shield provide additional electrostatic noise protection. Specifications

  • UL Subject 13
  • UL Subject 2250
  • NEC Article 725 Class 2 and Class 3 Circuits
  • NEC Type PLTC Listed, which is approved for cable tray use in Class 1, Division 2, hazardous areas and non-hazardous areas, cable trays, raceways, conduit and supported by messenger wires.
  • Sunlight-resistant.
  • Oil-resistant per UL Class 43
  • NEC Type ITC per Article 727. ITC cables may carry up to 5 amps at 150V, which is significantly greater than that allowed for PLTC only cables. ITC cables may also be installed in specific applications, per the NEC, in addition to those allowed for PLTC.
  • UL 1685 (UL 1581) Vertical Tray Flame Test comparable to IEEE 383-1974 (70,000 BTU/hr.)Flame Test.
  • PVC/PVC constructions are CMG, FT4, IEEE 1202 and IEEE 383-2003 rated, and meet ICEA T-29-520 Flame Test.
  • Design options — call 1-800-BELDEN-1 or 1-800-BELDEN-3. PLTC-ER As an option, Belden offers all PVC insulated, PVC jacketed instrumentation cables, and several other insulation and jackets, with a PLTC-ER (Exposed Run) rating, formerly referred to as Open Wiring. Per NEC Article 725, a PLTC-ER rated cable may be installed in an industrial establish- ment between a cable tray and the utilization equipment or device. A PLTC-ER rated cable must meet the crush and impact require- ments of UL Type MC cable By eliminating the need for metal conduit and/or armor, using a PLTC-ER rated cable results in savings in both installation and maintenance. UL Listed for PLTC Insulation/Jacket Max. Temp Rating XLPE/PVC 90°C XLPE/CPE 90°C PVC/PVC 105°C PVC/CPE 105°C PE/PVC 75°C FPE/PVC 75°C TPE/TPE 105°C XLPE/Haloarrest® 90°C Standard lengths may be subject to tolerance. Custom lengths may be available upon request. Contact the Belden Electronics Division Customer Service Department for additional information. 1-800-BELDEN-1 or 1-800-BELDEN-3. Armor Code Material

2 Aluminum Interlock

3 Steel Interlock

8 Continuously Corrugated Aluminum

1 PVC

3 CPE

4 TPE

5 HDPE

6 Oil Res II

7 Haloarrest® I

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.42 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable 300V Power-Limited Tray Cables Industrial Grade Sunlight- and Oil-Resistant Jackets

22 AWG Pairs Stranded (7x30) Tinned Copper Conductors • Twisted Pairs

Unshielded • PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 19.0 8.2 Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 22.0 10.0 1000 304.8 42.0 19.1 1000 304.8 51.0 23.2 1000 304.8 67.0 30.5 1000 304.8 89.0 40.4 1000 304.8 121.0 55.0 1000 304.8 147.0 66.4 1000 304.8 178.0 80.9 1000 304.8 224.0 101.8 1000 † 304.8 321.0 145.9

22 AWG Pairs Stranded (7x30) Bare Copper Conductors* • Twisted Pairs

Overall Beldfoil Shield (100% Coverage) • PVC Insulation • PVC Jacket (Black or Chrome) PVC = Polyvinyl Chloride *For tinned copper conductors, order with B suffix. **For Exposed Run rated cable (3000 series only), order with E suffix, e.g. 3000AE. †Final put-up length may vary ±10% from length shown. ††Bulk = Check length available for specific construction. E1, E2 = Refer to Industrial Technical Information section for color code. Alternate color coding available upon request. Multiple pair or triad cables have each pair/triad numbered for ease of identification. Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Pairs Lbs. kg Inch mm Rip Cord Drain Wire Drain Wire Rip Cord Communication Wire Rip Cord NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.43 18 • Industrial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable 300V Power-Limited Tray Cables Industrial Grade Sunlight- and Oil-Resistant Jackets Individually Shielded • PVC Insulation • Chrome PVC Jacket 1000 304.8 46.0 20.9 1000 304.8 60.0 27.3 1000 304.8 75.0 34.0 1000 304.8 111.0 50.4 1000 304.8 145.0 65.9 1000 304.8 177.0 80.5 1000 304.8 287.0 130.5 Individually Shielded + Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • PVC Jacket (Black or Chrome) 3001A 3005A 3007A 3009A 3011A 3013A 3015A

22 AWG Triads Stranded (7x30) Tinned Copper Conductors • Twisted Triads

Unshielded • PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 23.0 10.4 Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 26.0 11.8

22 AWG Triads Stranded (7x30) Bare Copper Conductors* • Twisted Triads

Overall Beldfoil Shield (100% Coverage) • PVC Insulation • PVC Jacket (Black or Chrome) Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC Insulation • PVC Jacket (Black or Chrome) *For tinned copper conductors, order with B suffix. E1, E2 = Refer to Technical Information section for color code. Alternate co lor coding available upon request. †For Exposed Run rated 3000 series cables, order with “E” suffix, e.g. 3001AE. Multiple pair or triad cables have each pair/tria d numbered for ease of identification. ††Bulk = Check length available for specific construction. Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Pairs/ Triads Lbs. kg Inch mm Rip Cord Rip Cord Rip Cord Rip Cord Communication Wire Rip Cord Communication Wire Drain Wires Drain Wires Drain Wire Drain Wire Rip Cord Communication Wire NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 Drain Wires For Exposed Run rated cable, order 3003AE For Exposed Run rated cable, order 3002AE

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.44 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable 300V Power-Limited Tray Cables Industrial Grade Sunlight- and Oil-Resistant Jackets

20 AWG Pairs Stranded (19x32) Tinned Copper Conductors • Twisted Pairs

Unshielded • PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 23.0 10.4 Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 28.0 12.7

20 AWG Pairs Stranded (7x28) Bare Copper Conductors • Twisted Pairs

Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (See chart below for other options) 10000 † 3048.0 270.0 122.5 Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (Other options below) F-R = Flame-retardant †Final put-up length may vary ±10% from length shown. ††Bulk = Check length available for specific construction. E1, E2 = Refer to Technical Information section for color code. Alternate color coding available upon request. Multiple pair or triad cables have each pair/triad numbered for ease of identification. Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Pairs Lbs. kg Inch mm Rip Cord Rip Cord Drain Wire Drain Wire Rip Cord Rip Cord Communication Wire Communication Wire Drain Wires NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 Conductor, Insulation and Jacket Options Bare Tinned Insulation/Jacket AB PVC/PVC CD XLPE/PVC KL TPE/TPE QR XLPE/CPE ST XLPE/Haloarrest® For 1000 and 3000 Series cables only.

1234 A E

Part letter code Run rating No. for desired if desired conductor, insulation & jacket To Specify:

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.45 18 • Industrial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable 300V Power-Limited Tray Cables Industrial Grade Sunlight- and Oil-Resistant Jackets

20 AWG Triads Stranded (19x32) Tinned Copper Conductors • Twisted Triads

Unshielded • PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 29.0 13.2 Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 32.0 14.5

20 AWG Triads Stranded (7x28) Bare Copper Conductors • Twisted Triads

Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (See chart below for other options) Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (Other options below) †Final put-up length may vary ±10% from length shown. ††Bulk = Check length available for specific construction. E1 = Refer to Technical Information section for color code. Alternate color coding available upon request. Multiple pair or triad cables have each pair/triad numbered for ease of identification. Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Triads Lbs. kg Inch mm Rip Cord Rip Cord Drain Wire Drain Wire Drain Wires Rip Cord Communication Wire Communication Wire Rip Cord Conductor, Insulation and Jacket Options Bare Tinned Insulation/Jacket AB PVC/PVC CD XLPE/PVC KL TPE/TPE QR XLPE/CPE ST XLPE/Haloarrest® For 1000 and 3000 Series cables only. Part letter code Run rating No. for desired if desired conductor, insulation & jacket To Specify: NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.46 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable 300V Power-Limited Tray Cables Industrial Grade Sunlight- and Oil-Resistant Jackets

18 AWG Pairs Stranded (19x30) Tinned Copper Conductors • Twisted Pairs

Unshielded • PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 28.0 12.7 Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 33.0 15.0 1000 304.8 69.0 31.4 1000 304.8 98.0 49.4 1000 304.8 112.0 50.8 1000 304.8 153.0 69.5 1000 304.8 215.0 97.6 1000 304.8 270.0 122.5 1000 304.8 342.0 155.5 Individually Shielded (100% Coverage) • PVC Insulation • Chrome PVC Jacket 1000 304.8 73.0 33.2 1000 304.8 109.0 49.5 1000 304.8 135.0 61.4 1000 304.8 190.0 86.4 1000 304.8 270.0 123.6 1000 304.8 321.0 145.9 1000 304.8 428.0 194.5 E1, E2 = Refer to Technical Information section for color code. Alternate color coding available upon request. Multiple pair or triad cables have each pair/triad numbered for ease of identification. †Bulk = Check length available for specific construction. Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Pairs Lbs. kg Inch mm Rip Cord Rip Cord Rip Cord Drain Wire Drain Wire NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 Conductor, Insulation and Jacket Options Bare Tinned Insulation/Jacket AB PVC/PVC CD XLPE/PVC KL TPE/TPE QR XLPE/CPE ST XLPE/Haloarrest® For 1000 and 3000 Series cables only. Part letter code Run rating No. for desired if desired conductor, insulation & jacket To Specify:

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.47 18 • Industrial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable 300V Power-Limited Tray Cables Industrial Grade Sunlight- and Oil-Resistant Jackets

18 AWG Pairs Stranded (7x26) Bare Copper Conductors • Twisted Pairs

Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (See chart below for other options) 10000 † 3048.0 380.0 172.5 Individually Shielded + Overall Beldfoil (100% Coverage) • PVC Insulation • Black PVC Jacket(Other options below) 5000 † 1524.0 3390.0 1539.1 E1 = Refer to Technical Information section for color code. Alternate color coding available upon request. Multiple pair or triad cables have each pair/triad numbered for ease of identification. †Final put-up length may vary ±10% from length shown. ††Bulk = Check length available for specific construction. Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Pairs Lbs. kg Inch mm Rip Cord Rip Cord Drain Wires Drain Wire Communication Wire Communication Wire NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 Conductor, Insulation and Jacket Options Bare Tinned Insulation/Jacket AB PVC/PVC CD XLPE/PVC KL TPE/TPE QR XLPE/CPE ST XLPE/Haloarrest® For 1000 and 3000 Series cables only. Part letter code Run rating No. for desired if desired conductor, insulation & jacket To Specify:

300V Power-Limited Tray Cables Industrial Grade Sunlight- and Oil-Resistant Jackets INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.48 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com

18 AWG Triads Stranded (19x30) Tinned Copper Conductors • Twisted Triads

Unshielded • PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 38.0 17.2 Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 43.0 19.5

18 AWG Triads Stranded (7x26) Bare Copper Conductors • Twisted Triads

Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (See chart below for other options) 10000 † 3048.0 430.0 195.1 Individually Shielded + Overall Beldfoil (100% Coverage) • PVC Insulation • Black PVC Jacket (Other options below) E1 = Refer to Technical Information section for color code. Alternate color coding available upon request. Multiple pair or triad cables have each pair/triad numbered for ease of identification. †Final put-up length may vary ±10% from length shown. ††Bulk = Check length available for specific construction. Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Triads Lbs. kg Inch mm Rip Cord Rip Cord Drain Wire Drain Wire Drain Wires Rip Cord Rip Cord Communication Wire Communication Wire NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 Conductor, Insulation and Jacket Options Bare Tinned Insulation/Jacket AB PVC/PVC CD XLPE/PVC KL TPE/TPE QR XLPE/CPE ST XLPE/Haloarrest® For 1000 and 3000 Series cables only. Part letter code Run rating No. for desired if desired conductor, insulation & jacket To Specify:

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.49 18 • Industrial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable 300V Power-Limited Tray Cables Industrial Grade Sunlight- and Oil-Resistant Jackets Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Pairs Lbs. kg Inch mm

16 AWG Pairs Stranded (19x29) Tinned Copper Conductors • Twisted Pairs

Unshielded • PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 36.0 16.3 Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 41.0 18.6

16 AWG Pairs Stranded (7x24) Bare Copper Conductors • Twisted Pairs

Unshielded • PVC Insulation • Black PVC Jacket (See chart below for other insulation and jacket options) 10000 † 3048.0 400.0 181.4 Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (See chart below for other options) 10000 † 3048.0 480.0 217.7 Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket(Options below) E1, E2 = Refer to Technical Information section for color code. Alternate color coding available upon request. Multiple pair or triad cables have each pair/triad numbered for ease of identification. †Final put-up length may vary ±10% from length shown. ††Bulk = Check length available for specific construction. Rip Cord Communication Wire Rip Cord Rip Cord Rip Cord Rip Cord Communication Wire Drain Wires Drain Wire Drain Wire NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 Conductor, Insulation and Jacket Options Bare Tinned Insulation/Jacket AB PVC/PVC CD XLPE/PVC KL TPE/TPE QR XLPE/CPE ST XLPE/Haloarrest® For 1000 and 3000 Series cables only. Part letter code Run rating No. for desired if desired conductor, insulation & jacket To Specify:

300V Power-Limited Tray Cables Industrial Grade Sunlight- and Oil-Resistant Jackets INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.50 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Triads Lbs. kg Inch mm

16 AWG Triads Stranded (19x29) Tinned Copper Conductors • Twisted Triads

Unshielded • PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 48.0 21.8 Overall Beldfoil® Shield (100% Coverage)• PVC Insulation • Chrome PVC Jacket U-1000 U-304.8 54.0 24.5

16 AWG Triads Stranded (7x24) Bare Copper Conductors • Twisted Triads

Unshielded • PVC Insulation • Black PVC Jacket (See chart below for other options) 4000 † 1219.2 208.0 94.4 Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (See chart below for other options) 10000 † 3048.0 610.0 276.7 Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket(Options below) E1 = Refer to Technical Information section for color code. Alternate color coding available upon request. Multiple pair or triad cables have each pair/triad numbered for ease of identification. †Final put-up length may vary ±10% from length shown. ††Bulk = Check length available for specific construction. Rip Cord Rip Cord Rip Cord Rip Cord Drain Wire Drain Wires Communication Wire Rip Cord Communication Wire Drain Wire NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CMG CEC: CMG FT4 IEEE 1202/383 ICEA T-29-520 Conductor, Insulation and Jacket Options Bare Tinned Insulation/Jacket AB PVC/PVC CD XLPE/PVC KL TPE/TPE QR XLPE/CPE ST XLPE/Haloarrest® For 1000 and 3000 Series cables only. Part letter code Run rating No. for desired if desired conductor, insulation & jacket To Specify:

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.51 18 • Industrial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable 300V Power-Limited Tray Cables Industrial Grade Sunlight- and Oil-Resistant Jackets Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Pairs/ Triads Lbs. kg Inch mm

14 AWG Pairs Stranded (42x30) Tinned Copper Conductors • Twisted Pairs

Unshielded • PVC Insulation • Chrome PVC Jacket 1000 304.8 60.0 27.3 Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket 1000 304.8 66.0 29.9

14 AWG Triads Stranded (42x30) Tinned Copper Conductors • Twisted Triads

Unshielded • PVC Insulation • Chrome PVC Jacket 1000 304.8 86.0 39.0 Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket 1000 304.8 88.0 40.0 E1, E2 = Refer to Technical Information section for color code. Alternate color coding available upon request. Rip Cord Rip Cord Rip Cord Rip Cord Drain Wire Drain Wire NEC: PLTC, ITC, CL3R CEC: FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CL3R CEC: FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CL3R CEC: FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CL3R CEC: FT4 IEEE 1202/383 ICEA T-29-520

300V Power-Limited Tray Cables Industrial Grade Sunlight- and Oil-Resistant Jackets INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.52 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Pairs/ Triads Lbs. kg Inch mm

12 AWG Pairs Stranded (65x30) Tinned Copper Conductors • Twisted Pairs

Unshielded • PVC Insulation • Chrome PVC Jacket 1000 304.8 83.0 37.7 Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket 1000 304.8 96.0 43.6

12 AWG Triads Stranded (7x20) Bare Copper Conductors • Twisted Triads

Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (See chart below for other options) E1, E2 = Refer to Technical Information section for color code. Alternate color coding available upon request. †Bulk = Check length available for specific construction. Rip Cord Rip Cord Rip Cord Drain Wire Drain Wire NEC: PLTC, ITC, CL3R CEC: FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CL3R CEC: FT4 IEEE 1202/383 ICEA T-29-520 NEC: PLTC, ITC, CL3R CEC: FT4 IEEE 1202/383 ICEA T-29-520 Conductor, Insulation and Jacket Options Bare Tinned Insulation/Jacket AB PVC/PVC CD XLPE/PVC KL TPE/TPE QR XLPE/CPE ST XLPE/Haloarrest® For 1000 and 3000 Series cables only. Part letter code Run rating No. for desired if desired conductor, insulation & jacket To Specify:

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.53 18 • Industrial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable Thermocouple Extension Cables and Thermocouple Wire — Overview Construction Thermocouple Extension Cable Conductor material determined by the thermocouple extension wire type. FEP or PVC insulated with FEP or PVC jacket. Nylon rip cord included in all PVC-jacketed thermocouple extension cables. Communi- cation wire included on all multi-pair, PVC constructions — 22 AWG (7x30) bare copper orange PVC insulation. NOTE: The temperature ranges in Table A are applicable only to the thermocouple conductors and not to the cable. The cable must never be exposed to temperatures higher than the maximum temperature ratings shown in Table B. Table B: Other Insulation/Jacket Options Application Unshielded Parallel non-shielded extension wire may be utilized in low noise environments when recommended by the instrument manufacturer. Overall Shield Recommended, except in areas where high voltage and current sources create excessive noise interference. The Beldfoil ® shield with drain wire provides 100% coverage for maximum shield effectiveness. Individually Shielded Individually shielded pairs are recommended for use in applications where optimum noise rejection is required. PVC Insulated, PVC Jacketed Cable Specifications

  • UL Subject 13
  • UL 1685 (UL 1581) Vertical Tray Flame Test comparable to IEEE 383-1974 (70,000 BTU) Flame Test
  • ANSI/MC 96.1–1982
  • NEC CMG
  • NEC Type PLTC Listed, which is approved for cable tray use in Class 1, Division 2, hazardous areas and non-hazardous areas, cable trays, raceways, conduit and supported by messenger wires.
  • NEC Type ITC Listed, which is approved for cable tray use, raceways hazardous locations according to Articles 501, 502, 503 and 504; or as aerial on a cable messenger, and under raised floors in control rooms and rack rooms where arranged to prevent damage to the cable. Usages are allowed based on qualified persons servicing all installations.
  • PVC/PVC constructions are CMG, FT4, IEEE 1202 and IEEE 383-2003 rated, and meet ICEA T-29-520 Flame Test.
  • UL 1277 TC versions approved for use in Class 1 trays available as special. Shielded Twisted Pair (FEP insulated, FEP jacketed cable specifications)
  • UL Subject 13
  • NFPA 262 (UL 910 Steiner Tunnel Flame Test) comparable to FT6 Flame Test
  • ANSI/MC 96.1–1982
  • NEC Type CL3P/PLTC Listed, which is approved for use in ducts, plenums and other space used for environmental air.
  • UL 1277 TC versions approved for use in Class 1 trays available as special. Thermocouple Wire Conductor material determined by the thermocouple type. FEP insulated and jacketed flat constructions. FEP thermocouple wire is impervious to chemical attack and is flame retardant. Jacket Color Limits of Error Standard (°C) Temperature Range (°C) (conductor only) Positive ( + ) Negative ( - ) Conductor IdentificationANSI Symbol UL Listed for PLTC Insulation/Jacket Max. Temp Rating XLPE/PVC 90°C XLPE/CPE 90°C PVC/PVC 105°C PVC/CPE 105°C PE/PVC 75°C FPE/PVC 75°C TPE/TPE 105°C XLPE/Haloarrest® 90°C FEP/FEP 200°C E 0 to 340 ±1.7°C Brown Purple Red Chromel ® Constantan 340 to 540 ±.50% Non-magnetic Silver Color J 0 to 293 ±2.2°C Brown White Red Iron Constantan 293 to 480 ±.75% Magnetic Non-magnetic K 0 to 293 ±2.2°C Brown Yellow Red Chromel Alumel ® 293 to 980 ±.75% Non-magnetic Magnetic T 0 to 133 ±1.0°C Brown Blue Red Copper Constantan 133 to 260 ±.75% Copper Color Non-magnetic EX 0 to 200 ±1.7°C Purple Purple Red Chromel Constantan JX 0 to 200 ±2.2°C Black White Red Iron Constantan KX 0 to 200 ±2.2°C Yellow Yellow Red Chromel Alumel TX 0 to 100 ±1.0°C Blue Blue Red Copper Constantan Limits of error per ANSI MC96.1-1982. Limits shown do not include system or installation error. Percentages refer to the temper ature being measured. *The Temperature Range and Limits of Error are for standard grade thermocouples, Reference ANSI MC96.1-1982 for special grade t hermocouples. The Temperature Ranges for type E, J, K and T thermocouple wires listed above pertain to 20 AWG wire. Additional constructions available upon request. Table A: Thermocouple Identification and Limits of Error — Reference Junction 0°C * Positive ( + ) Negative ( - ) Insulation Color Code Standard lengths may be subject to tolerance. Custom lengths may be available upon request. Contact the Belden Electronics Division Customer Service Department for additional information. 1-800-BELDEN-1

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.54 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable Thermocouple Extension Cables Industrial Grade Sunlight- and Oil-Resistant Jackets 20 AWG Pairs Solid Conductors • (See chart on page 18.53 for conductor specifications by ANSI Type) Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • PVC Jacket Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC Insulation • PVC Jacket 16 AWG Pairs Solid Conductors • (See chart on page 18.53 for conductor specifications by ANSI Type) Overall Beldfoil Shield (100% Coverage) • PVC Insulation • PVC Jacket 10000 † 3048.0 420.0 190.7 10000 † 3048.0 420.0 190.7 Multiple pair cables have each pair numbered for ease of identification. †Final put-up length may vary ±10% from length shown. Jacket Color Inch mm Nominal OD Standard Lengths Ft. Color Code No. of Pairs Inch mm Insulation ThicknessPart No.Description m Standard Unit WeightANSI Type Lbs. kg Rip Cord Drain Wire Rip Cord Drain Wire Drain Wires Rip Cord Communication Wire 300V 105°C NEC: PLTC, ITC, CMG CEC: CMG FT4 ICEA T-29-520 IEEE 1202/383 300V 105°C NEC: PLTC, ITC, CMG CEC: CMG FT4 ICEA T-29-520 IEEE 1202/383 300V 105°C NEC: PLTC, ITC, CMG CEC: CMG FT4 ICEA T-29-520 IEEE 1202/383

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.55 18 • Industrial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable High-Temperature Thermocouple Extension Cables and Thermocouple Wire Industrial Grade Sunlight- and Oil-Resistant Jackets High-Temp Extension Cable • 20 AWG Solid Conductors• (See chart on page 18.53 for conductor specifications by ANSI Type) Plenum • Unshielded • FEP Insulation • FEP Jacket NEC: PLTC, CL3P 1000 † 304.8 12.0 5.4 xx .128 3.25 xx .128 3.25 High-Temp Extension Cable • 20 AWG Stranded (7x28) Conductors • (See chart on page 18.53 for conductor specifications by ANSI Type) Plenum • Unshielded • FEP Insulation • FEP Jacket NEC: PLTC, CL3P 1000 † 304.8 13.0 6.0 xx .140 3.56 Plenum • Overall Beldfoil® Shield (100% Coverage) • FEP Insulation • FEP Jacket NEC: PLTC, CL3P 1000 † 304.8 16.0 7.3 1000 † 304.8 16.0 7.3 1000 † 304.8 16.0 7.3 1000 † 304.8 17.0 7.7 High-Temp Extension Cable • 16 AWG Pairs Solid Conductors• (See chart on page 18.53 for conductor specifications by ANSI Type) Plenum • Overall Beldfoil Shield (100% Coverage) • FEP Insulation • FEP Jacket High-Temp Extension Cable • 16 AWG Pairs Stranded (7x24) Conductors • (See chart on page 18.53 for conductor specifications by ANSI Type) Plenum • Overall Beldfoil Shield (100% Coverage) • FEP Insulation • FEP Jacket NEC: PLTC, CL3P 1000 † 304.8 35.0 15.9 1000 † 304.8 32.0 14.5 High-Temp Thermocouple Wire • 20 AWG Solid Conductors• (See chart on page 18.53 for conductor specifications by ANSI Type) Plenum • Unshielded • FEP Insulation • FEP Jacket NEC: PLTC, CL3P 1000 † 304.8 13.0 6.0 xx .128 3.25 500 † 152.4 7.0 3.2 xx 500 † 152.4 7.0 3.2 xx 500 † 152.4 7.0 3.2 xx FEP = Fluorinated Ethylene-propylene Multiple pair cables have each pair numbered for ease of identification. †Final put-up length may vary ±10% from length shown. Jacket Color Inch mm Nominal OD Standard Lengths Ft. Color Code No. of Pairs/ Cond. Inch mm Insulation ThicknessPart No.Description m Standard Unit WeightANSI Type Lbs. kg Drain Wire Drain Wire Drain Wire

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.56 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable 600V Tray Cables – Overview Construction Soft annealed bare or tinned copper conductors. PVC insulated with a nylon overcoat, 90°C PVC Jacket, TFN, TFFN or THHN style singles. Nylon rip cord included in all PVC-Nylon/PVC instrumentation cables. Application These cables are suitable for installation in wet or dry locations. Cable jackets are resistant to sunlight, moisture and vapor penetration. The cables can be used in raceways, and (supported by messenger wire), outdoor applications and direct burial applications. Unshielded Twisted non-shielded instrument pairs provide a minimal OD allowing greater tray and conduit fill. Non-shielded instrument pairs may be utilized when recommended by the instrument manufacturer and used in a metallic conduit. Overall Shield Recommended for use in instrumentation applications where signals are transmitted in excess of 100 millivolts except in areas where high voltage and current sources creates excessive noise interference. The Beldfoil ® shield with drain wire provides 100% coverage for maximum shield effectiveness. Copper tape shield available upon request. Individually Shielded and Overall Shielded Individually shielded pairs or triads with an overall shield are recommended for use in instrumentation applications where optimum noise rejection is required. Individual pair/triad shields are fully isolated from each other and contain a separate drain wire for grounding, to provide maximum protection from crosstalk and common mode interference. Cables with an overall shield provide additional electrostatic noise protection. Specifications

  • UL Subject 1277 TC
  • UL 1685 (UL1581) Vertical Tray Flame Test comparable to IEEE 383-1974 (70,000 BTU/hr.) Flame Test
  • NEC Type TC Listed, which is approved for cable tray use in Class 1, Division 2 areas, per NEC Articles 340, 318 and 501 and for Class 1 circuits as permitted in Article 725
  • PVC-nylon/PVC constructions are NEC Type NPLF Listed, which is approved for use in Non Power-Limited Fire Protective Signaling circuits, per NEC Article 760
  • PVC-Nylon/PVC, XLPE/PVC and XLPE/CPE constructed cables meet IEEE 1202/IEEE 383-2003/FT4 (70,000 BTU) Flame Test
  • XLPE/Haloarrest cables are UL 1277 TC-LS rated TC-ER Rated Cables As an option, Belden offers all PVC-nylon/ PVC, XLPE/PVC and XLPE/CPE jacketed tray cables with a TC-ER (Exposed Run) rating, formerly referred to as Open Wiring. Per NEC Article 336, a TC-ER rated cable may be installed in an industrial establishment between a cable tray and the utilization equipment or device. A TC-ER rated cable must meet the crush and impact require- ments of UL Type MC cable. By eliminating the need for metal conduit and/or armor, using a TC-ER rated cable results in savings in both installation and maintenance. MC Cable Ratings Optional Customize any 600V TC instrumentation cable, with armor and a full-sized ground. See chart below to specify. Armor Code Material

7 Haloarrest

Overall Armor Core Conductor, Jacket Type 4-digit Insulation, Type Part No. Inner Jacket 600V TC Type Instrumentation To Specify MC Rated Cable Standard lengths may be subject to tolerance. Custom lengths may be available upon request. Contact the Belden Electronics Division Customer Service Department for additional information. 1-800-BELDEN-1. Bare Tinned Insulation/Jacket AB PVC-Nylon/PVC CD XLPE/PVC EF FRPO/PVC GH XLPE/TPE KL TPE/TPE MN PVC-Nylon/Oil Res II QR XLPE/CPE ST XLPE/Haloarrest *For 1000 and 3000 Series cables only. 1234 A Start Add or with replace Part letter No. code To Specify: Tray Cable Construction Options UL Listed for MC and TC Insulation/Jacket Flame Tests Ratings* Max. Temp Rating Wet Dry PVC-Nylon/PVC 75°C 90°C UL 1685 ICEA S-73-532 (THHN or THWN) FT4/IEEE 1202/383 ICEA S-61-402

14 AWG & larger ICEA T-29-520

PVC-Nylon/PVC N/A 90°C UL 1685 ICEA S-73-532 (TFN or TFFN) FT4/IEEE 1202/383 ICEA S-61-402 16 & 18 AWG ICEA T-29-520 XLPE/PVC or CPE 90°C 90°C UL 1685 ICEA S-73-532 (XHHW–2) FT4/IEEE 1202/383 ICEA S-66-524

14 AWG & larger VW-1 rated singles

XLPE/PVC or CPE 75°C 75°C UL 1685 ICEA S-73-532 (RFH–2) FT4/IEEE 1202/383 ICEA S-66-524 16 & 18 AWG VW-1 rated singles ICEA S-82-552 ICEA T-29-520 FRPO/PVC — 75°C UL 1685

18 AWG & larger

TPE/TPE 75°C 90°C UL 1685 FRPO/PVC 75°C 90°C UL 1685 XLPE/Haloarrest® 90°C 90°C UL 1685 TC-LS (XHHW-2) ICEA T-29-520

14 AWG & larger FT4/IEEE 1202/383

XLPE/Haloarrest 75°C 75°C UL 1685 TC-LS (RFH-2) ICEA T-29-520 16 & 18 AWG FT4/IEEE 1202/383 FEP/PVC 90°C 90°C UL 1685 CPE = Chlorinated Polyethylene • FEP = Fluorinated Ethylene-propylene • FRPO = Flame-retardant Polyolefin • PVC = Polyvinyl Chloride • TPE = Thermoplastic Elastomer • XLPE = Cross-linked Polyethylene *Applicable to TC-rated cables only. Conductor, Insulation and Jacket Options*

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.57 18 • Industrial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable 600V Tray Cables Industrial Grade Sunlight- and Oil-Resistant Jackets Unshielded • PVC/Nylon Insulation • Black PVC Jacket Overall Beldfoil® Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket 1000 304.8 43.0 19.5 Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options) Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (Options below) E1, E2 = Refer to Technical Information section for color code. Alternate color coding available upon request. Multiple pair or triad cables have each pair/triad numbered for ease of identification. †Final put-up length may vary ±10% from length shown. ††Bulk = Check length available for specific construction. Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Pairs Lbs. kg Inch mm Conductor, Insulation and Jacket Options Bare Tinned Insulation/Jacket AB PVC-Nylon/PVC CD XLPE/PVC EF FRPO/PVC GH XLPE/TPE KL TPE/TPE MN PVC-Nylon/Oil Res II QR XLPE/CPE ST XLPE/Haloarrest® For 1000 and 3000 Series cables only. Rip Cord Rip Cord Rip Cord Rip Cord Drain Wire Drain Wires Drain Wire NEC: TC, NPLF ICEA S-73-532, ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC, NPLF ICEA S-73-532, ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 Part letter code Run rating No. for desired if desired conductor, insulation & jacket To Specify:

Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket(Green Ground) 5000 † 1524.0 320.0 145.3 Overall Beldfoil Shield (100% Coverage) • XLPE Insulation • Black PVC Jacket(Green Ground) 5000 † 1524.0 375.0 170.3 Overall Beldfoil® Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options) 1000 † 304.8 53.0 24.0 10000 † 3048.0 560.0 254.0 Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (Options below) 5000 † 1524.0 2875.0 1304.1 E1, E2 = Refer to Technical Information section for color code. Alternate color coding available upon request. Multiple pair or triad cables have each pair/triad numbered for ease of identification. †Final put-up length may vary ±10% from length shown. ††Bulk = Check length available for specific construction. INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.58 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable 600V Tray Cables Industrial Grade Sunlight- and Oil-Resistant Jackets Conductor, Insulation and Jacket Options Bare Tinned Insulation/Jacket AB PVC-Nylon/PVC CD XLPE/PVC EF FRPO/PVC GH XLPE/TPE KL TPE/TPE MN PVC-Nylon/Oil Res II QR XLPE/CPE ST XLPE/Haloarrest® Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Pairs/ Triads Lbs. kg Inch mm Rip Cord Drain Wire Drain Wires Rip Cord NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 Part letter code Run rating No. for desired if desired conductor, insulation & jacket To Specify: Rip Cord Drain Wire NEC: TC-ER, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC-ER, NPLF ICEA S-73-532 ICEA S-66-524 ICEA T-29-520 FT4/IEEE 1202/383 Ground Rip Cord Drain Wire Ground

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.59 18 • Industrial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable 600V Tray Cables Industrial Grade Sunlight- and Oil-Resistant Jackets Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Pairs Lbs. kg Inch mm Unshielded • PVC/Nylon Insulation • Black PVC Jacket 1000 304.8 54.0 24.5 Overall Beldfoil® Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket 1000 304.8 56.0 25.4 Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options) Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket(Options below) E1, E2 = Refer to Technical Information section for color code. Alternate color coding available upon request. Multiple pair or triad cables have each pair/triad numbered for ease of identification. †Final put-up length may vary ±10% from length shown. ††Bulk = Check length available for specific construction. Rip Cord Rip Cord Rip Cord Rip Cord Drain Wire Drain Wires Drain Wire NEC: TC, NPLF ICEA S-73-532, ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC, NPLF ICEA S-73-532, ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 Bare Tinned Insulation/Jacket AB PVC-Nylon/PVC CD XLPE/PVC EF FRPO/PVC GH XLPE/TPE KL TPE/TPE MN PVC-Nylon/Oil Res II QR XLPE/CPE ST XLPE/Haloarrest® Conductor, Insulation and Jacket Options For 1000 and 3000 Series cables only. Part letter code Run rating No. for desired if desired conductor, insulation & jacket To Specify:

Industrial Grade Sunlight- and Oil-Resistant Jackets INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.60 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Pairs/ Triads Lbs. kg Inch mm Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket(Green Ground) 5000 † 1524.0 340.0 154.4 Overall Beldfoil Shield (100% Coverage) • XLPE Insulation • Black PVC Jacket (Green Ground) 5000 † 1524.0 450.0 204.3 Overall Beldfoil® Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options) 1000 † 304.8 68.0 30.9 10000 † 3048.0 700.0 317.5 Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (Options below) E1, E2 = Refer to Technical Information section for color code. Alternate color coding available upon request. Multiple pair or triad cables have each pair/triad numbered for ease of identification. †Final put-up length may vary ±10% from length shown. ††Bulk = Check length available for specific construction. Conductor, Insulation and Jacket Options Bare Tinned Insulation/Jacket AB PVC-Nylon/PVC CD XLPE/PVC EF FRPO/PVC GH XLPE/TPE KL TPE/TPE MN PVC-Nylon/Oil Res II QR XLPE/CPE ST XLPE/Haloarrest® Rip Cord Drain Wire Drain Wires Rip Cord NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 Part letter code Run rating No. for desired if desired conductor, insulation & jacket To Specify: NEC: TC-ER, NPLF ICEA S-73-532 ICEA S-66-524 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC-ER, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 Rip Cord Drain Wire Ground Rip Cord Drain Wire Ground

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.61 18 • Industrial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com UL Instrumentation Cable 600V Tray Cables Industrial Grade Sunlight- and Oil-Resistant Jackets Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Pairs/ Triads Lbs. kg Inch mm Unshielded • PVC/Nylon Insulation • Black PVC Jacket Overall Beldfoil® Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket 1000 304.8 86.0 39.0

14 AWG Pairs Stranded (7x22) Bare Copper Conductors • Twisted Pairs

Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options)

14 AWG Triads Stranded (7x22) Bare Copper Conductors • Twisted Triads

Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options) E1, E2 = Refer to Technical Information section for color code. Alternate color coding available upon request. *Bulk = Check length available for specific construction. Rip Cord Rip Cord Drain Wire Rip Cord Drain Wire Rip Cord Drain Wire Conductor, Insulation and Jacket Options Bare Tinned Insulation/Jacket AB PVC-Nylon/PVC CD XLPE/PVC EF FRPO/PVC GH XLPE/TPE KL TPE/TPE MN PVC-Nylon/Oil Res II QR XLPE/CPE ST XLPE/Haloarrest® For 1000 and 3000 Series cables only. NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 Part letter code Run rating No. for desired if desired conductor, insulation & jacket To Specify:

Industrial Grade Sunlight- and Oil-Resistant Jackets INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.62 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com Standard Lengths Ft. Color Code mm Jacket Thickness Inch mm Nominal OD Lbs. N Maximum Pull Tension Inch Part No.Description Minimum Bend Radius m Standard Unit WeightNo. of Pairs/ Triads Lbs. kg Inch mm

12 AWG Pairs Stranded (37x27) Tinned Copper Conductors • Twisted Pairs

Unshielded • PVC/Nylon Insulation • Black PVC Jacket Overall Beldfoil® Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket 1000 304.8 111.0 50.4

12 AWG Pairs Stranded (7x20) Bare Copper Conductors • Twisted Pairs

Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options) Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options) E1, E2 = Refer to Technical Information section for color code. Alternate color coding available upon request. *Bulk = Check length available for specific construction. Rip Cord Rip Cord Conductor, Insulation and Jacket Options Bare Tinned Insulation/Jacket AB PVC-Nylon/PVC CD XLPE/PVC EF FRPO/PVC GH XLPE/TPE KL TPE/TPE MN PVC-Nylon/Oil Res II QR XLPE/CPE ST XLPE/Haloarrest® For 1000 and 3000 Series cables only. Drain Wire Rip Cord Drain Wire Rip Cord Drain Wire NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 NEC: TC, NPLF ICEA S-73-532 ICEA S-61-402 ICEA T-29-520 FT4/IEEE 1202/383 Part letter code Run rating No. for desired if desired conductor, insulation & jacket To Specify: