Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 11
Technical content
Features
– 16 digital inputs according to EN 61131-2 type 1 and type 3 –2 4 V DC, 2.4 mA – Connection of sensors in 1-wire technology – Minimum update time < 5 μs, bus-synchronous – Maximum input frequency: 100 kHz – Device type label stored – Diagnostic and status indicators This data sheet is only valid in association with the UM EN AXL SYS INST user manual. Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. 8610_en_01 2013-12-19
8610_en_01 PHOENIX CONTACT 2 2T a b l e o f c o n t e n t s
8610_en_01 PHOENIX CONTACT 3 Description Type Order No. Pcs. / Pkt. Axioline digital input module, 16 inputs, high speed, 24 V DC, 1-wire con- nection technology (including bus base module and connectors) AXL F DI16/1 HS 1H 2701722 1 3O r d e r i n g d a t a Accessories Type Order No. Pcs. / Pkt. Axioline F bus base module for housing type H (Replacement item) AXL F BS H 2700992 5 Axioline plug set (e.g., for AXL DI 16/1) (Replacement item) AXL CNS 2L-O/D/UI/E1/E2 2700985 1 Zack marker strip for Axioline (device labeling), in 2 x 20.3 mm pitch, un- printed, 25-section, for individual labeling with B-STIFT 0.8, X-PEN, or CMS-P1-PLOTTER (Marking) ZB 20,3 AXL UNPRINTED 0829579 25 Zack marker strip, flat, in 10 mm pitch, unprinted, 10-section, for individual labeling with M-PEN 0,8, X-PEN, or CMS-P1-PLOTTER (Marking) ZBF 10/5,8 AXL UNPRINTED 0829580 50 Documentation Type Order No. Pcs. / Pkt. User manual, English, Axioline F: System and installation UM EN AXL F SYS INST - - Dimensions (nominal sizes in mm) Width 35 mm Height 126.1 mm Depth 54 mm Note on dimensions The depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715).
4 Technical data
122,4126,1 General data Color gray Weight 133 g Ambient temperature (operation) -25 °C ... 60 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % (according to DIN EN 61131-2) Permissible humidity (storage/transport) 5 % ... 95 % (according to DIN EN 61131-2) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Protection class III, IEC 61140, EN 61140, VDE 0140-1
8610_en_01 PHOENIX CONTACT 4 Connection data Name Axioline plug Connection method Spring-cage connection with direct plug-in method Conductor cross section [AWG] 24 ... 16 Interface Axioline F local bus Connection method Bus base module Transmission speed 100 MBit/s Communications power Communications power UBus 5 V DC (via bus base module) Current consumption from Ubus max. 120 mA Power consumption at UBus max. 600 mW I/O supply Supply of digital input modules UI 24 V DC Maximum permissible voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Current consumption from UI 20 mA Power consumption at UI typ. 380 mW, max. 480 mW Surge protection of the supply voltage Electronic (35 V, 0.5 s) Polarity reversal protection of the supply voltage Parallel diode; with external 5 A fuse (for startup only) Protection max. 8 A (polarity re versal protection up to 5 A) When using for the first time, protect the module with a 5 A fuse. If all the modules are correctly connected in the system, the 5 A fuse can be replaced by an 8 A fuse. you can now load the module up to 8 A. NOTE: Damage to the electronics Provide the module with an external fuse to protect it against polarity reversal. The power supply unit must be able to supply four times the nominal current of the external fuse, to ensure that it trips in the event of an error. Digital inputs Number of inputs 16 Connection method Direct plug-in method Connection method 1-wire Description of the input EN 61131-2 types 1 and 3 Nominal input voltage 24 V DC Input voltage range -3 V DC ... 30 V DC Nominal input current 2.3 mA Current flow Linear until nominal current is reached, then constantly approximately 2.3 mA Input voltage range "0" signal -3 V DC ... 8.4 V DC Input voltage range "1" signal 9.4 V ... 30 V DC Input filter time < 5 µs Process data update < 5 µs (bus-synchronous) Polarity reversal protection of the inputs Parallel diode (30 V, 5 s) The minimum update time of the module can only be fully utilized if the station is configured accordingly, as the runtime of the local bus de- pends on the number of connected Axioline F modules (see also Axioline system manual). PROFIBUS telegram data Required parameter data 3 Byte Need for configuration data 6 Byte
8610_en_01 PHOENIX CONTACT 5 Error messages to the higher level control or computer system I/O supply failure Yes Electrical isolation/isolation of the voltage areas
5 V communications power (logic), 24 V supply (I/O) 500 V AC, 50 Hz, 1 min
5 V supply (logic)/functional earth ground 500 V AC, 50 Hz, 1 min
24 V supply (I/O) / functional earth ground 500 V AC, 50 Hz, 1 min
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5 g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 25 g, 11 ms period, half-sine shock pulse Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10 g Conformance with EMC Directive 2004/108/EC Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B; 6 kV contact discharge, 8 kV air discharge Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A; Field intensity: 10 V/m Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV Transient surge voltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical) Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V Noise emission test according to EN 61000-6-3 Radio interference properties EN 55022 Class B Approvals For the latest approvals, please visit phoenixcontact.net/products.
8610_en_01 PHOENIX CONTACT 6
5 Internal circuit diagram
Figure 1 Internal wiring of the terminal points Key:
6 Terminal point assignment
Figure 2 Terminal point assignment
7 Connection example
Figure 3 Example of a connection of sensors when using external busbars Ensure that GND of the sensors and GND for UI have the same potential. Microprocessor Optocoupler LED Power supply unit Electrically isolated area Input circuit Input circuit Local bus Axioline F local bus (hereinafter referred to as local bus) µC D UI DI 1...16U 24 V I UBus Local bus Input circuit 013233 00 0032 0133 µC Terminal point Color Assignment Supply voltage input a1, a2 Red 24 V DC (U I) Digital input module supply (internally jump- ered) b1, b2 Blue GND Reference potential of the supply voltage (in- ternally jumpered) Digital inputs IN16 Digital inputs 13 ... 16 0300 1310 2320 3330 +24 V IN13 +24 V IN1 +24 V IN4 +24 V IN16 +24 V
8610_en_01 PHOENIX CONTACT 7
8 Local status and diagnostic indicators
Figure 4 Local status and diagnostic indicators D UI 30 32 31 33 20 22 21 23 10 12 11 13 00 02 01 03 Designa- tion Color Meaning State Description D Red/yel- low/green Diagnostics of local bus communication Power down OFF Device in (power) reset. Not connected Red flash- ing Device operating, but there is no connection to previous device. Reset Red ON Application reset Device operating, but there is still a connection to the previous de- vice, the application is reset. Ready Yellow ON Device operating, there is still a connection to the previous device, but the device has not yet detected a valid cycle after power on. Connected Yellow flashing Valid data cycles have been detected, but the device is (not) yet part of the current configuration. Device applica- tion not active Green/yel- low alter- nating Valid data cycles are being detected. The master application set the output data to valid, however, the slave application has not set the input data to valid as yet. Active Green flashing Device operating, communications within the station is OK. The master application does not read the input data. (The connection to the controller has not yet been established, for example.) Run Green ON Valid data cycles are being detected. All data is valid UI Green U Input ON Supply of digital input modules present. OFF Supply of digital input modules not present. 00 ... 03, 10 ... 13, 20 ... 23, 30 ... 33 Yellow Status of the in- puts ON Input is set. OFF Input is not set. For more information on the meaning of local diagnostic and status indicators, please refer to the UM EN AXL SYS INST user manual.
8610_en_01 PHOENIX CONTACT 8 9P r o c e s s d a t a The I/O data is displayed in S7-compatible format.
10 Parameter, diagnostics and
information (PDI) Parameter and diagnostic data as well as other information is transmitted via the PDI channel of the Axioline F station. The standard and application objects stored in the module are described in the following section. The following applies to all tables below: Please refer to the UM EN AXL SYS INST or the basic pro- file for an explanation of the object codes and data types. Byte Byte 0 (high byte) B i t 76543210 C h a n n e l 87654321 Terminal point 13 12 11 10 03 02 01 00 Byte Byte 1 (low byte) B i t 76543210 C h a n n e l1 61 51 41 31 21 11 09 Terminal point 33 32 31 30 23 22 21 20 For information on PDI, please refer to the UM EN AXL SYS INST user manual. Please refer to the basic profile for compre- hensive information. Abbreviation Meaning A Number of elements L Length of the elements RR e a d WW r i t e Every visible string is terminated with a zero terminator (00 hex). The length of a visible string element is therefore one byte larger than the amount of user data.
8610_en_01 PHOENIX CONTACT 9
11 Standard objects
11.1 Objects for identificati on (device rating plate)
(hex) Object name Object type Data type A L Rights Meaning Contents Manufacturer
0001 VendorName Var Visible String 1 16 R Manufacturer name Phoenix Contact
0002 VendorID Var Visible String 1 7 R Manufacturer identifi-
0003 VendorText Var Visible St ring 1 49 R Comment on the
0012 VendorURL Var Visible String 1 30 R URL of the manufac-
http:// phoenixcon- tact.com Module - general
0004 DeviceFamily Var Visible String 1 15 R Device family I/O digital IN
0006 ProductFamily Var Visible String 1 33 R Product family Axioline - High
000E CommProfile Var Visible String 1 4 R Communication pro- file 633 000F DeviceProfile Var Visible String 1 5 R Device profile 0010
0011 ProfileVersion Record Visible String 2 11; 22 R Device profile version 2009-10-22; Basic -
Profile V1.12 003A VersionCount Array Unsigned 16 4 4 * 2 R Version counter 0007 0001 0000 0000 hex Module - special
0005 Capabilities Array Visible String 1 8 R Properties SyncI_0
0007 ProductName Var Visible String 1 19 R Pr oduct designation AXL F DI16/1 HS 1H
0008 SerialNo Var Visible String 1 11 R Serial number xxxxxxxxxx (e. g., 1234512345)
0009 ProductText Var Visible String 1 18 R Product text 16 digital inputs
000A OrderNumber Var Visible String 1 8 R Order No. 2701722 000B HardwareVersion Record Visible String 2 11; 3 R Hardware version e. g., 2011-02-04; 00 000C FirmwareVersion Record Visible String 2 11; 3 R Firmware version 0000-00-00; -- 000D PChVersion Record Visible Stri ng 2 11; 20 R Parameter channel version 2011-12-07; Basic Profile V2.0
0037 DeviceType Var Octet string 1 8 R Module identification 00 80 00 02 00 00 00
0014 Location Var Visible String 1 59 R/W Insta llation location Can be filled out by
the user.
0015 EquipmentIdent Var Visible String 1 59 R/W Eq uipment identifier Can be filled out by
the user.
0016 ApplDeviceAddr Var Unsigned 16 1 2 R/W User-defined device
the user.
8610_en_01 PHOENIX CONTACT 10
11.2 Object for multilingual capacity
11.3 Diagnostics objects
Diagnostics state (0018hex: DiagState) This object is used for a structured message of an error. Error code and status of the local status and diagnostics indicators Index (hex) Object name Object type Data type A L Rights Meaning Contents
0017 Language Record Visible String 2 6; 8 R Language en-us; English
(hex) Object name Object type Data type A L Rights Assignment/content
0018 DiagState Record 6 2; 1; 1;
2; 1; 1 R Diagnostics state; see below 0018hex: DiagState (Read) Subindex Data type Length in bytes Meaning Contents
0 Record 8 Diagnostic state Complete diagnostics information
1 Unsigned 16 2 Error number 0 ... 65535 dec
2 Unsigned 8 1 Priority 00 hex No error
3U n s i g n e d 8 1 G r o u p 0 0 hex No error FFhex Entire device
4 Unsigned 16 2 Error code See table below
5 Unsigned 8 1 More information follows 00
hex (not supported)
6 Visible String 1 Text 00 hex (not supported)
Error code Error Priority Group D LED UI LED 0000hex No error 00 hex 00hex Green ON ON 3412hex I/O supply failure 01 hex FFhex Flashing green/yellow OFF After all errors have been eliminated, it is au- tomatically reset.
8610_en_01 11PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany phoenixcontact.com
11.4 Objects for process data management
The objects 003Bhex and 003Chex are only applicable to tools. IN process data (0025hex: PDIN) You can read the IN process data of the module with this object. The structure corresponds to the representation in the "Process data" section.
12 Device descriptions
The device is described in the device description files. The device descriptions for controllers from Phoenix Con- tact are included in PC Worx and the corresponding service packs. The device description files for other systems are available for download at phoenixcontact.net/download in the down- load area of the bus coupler used. Index (hex) Object name Object type Data type A L Rights Assignment
0025 PDIN Var Octet string 1 2 R Input process data
003B PDIN_Descr Array of Re- cords 3 8; 2; 2 R Description of the IN process data 003C PDOUT_Descr Array of Re- cords 3 8; 2; 2 R Description of the output process data 0025hex: PDIN (Read) Subindex Data type Length in bytes Meaning