FEATURES
Excellent surge capabilities (Stud Version), 85A DO-203AB(DO-5) PRODUCT SUMMARY IF(AV) 85A Short reverse recovery time Available RoHS* COMPLIANT Stud cathode and stud anode versions Voltage up to 1200 VRRM Compliant to RoHS directive 2002/95/EC DC power supplies lnverters Converters 85FD(R)Series Choppers Ultrasonic systems Freewheeling diodes www.nellsemi.com MAJOR RATINGS AND CHARACTERISTICS UNIT V IFSM IF(AV) 2I t 2A s A CHARACTERISTICS Maximum TC ns A 200 to 1200 50 HZ 60 HZ 50 HZ 60 HZ Range ºC-40 to 125 SYMBOL 2I √t VRRM trr TJ Range See Recovery Characteristics table 2I √t 2I √s 85FD(R) 1308 1369 8554 7778 85543 ºC ELECTRICAL SPECIFICATIONS VOLTAGE RATINGS VOLTAGETYPE NUMBER CODE V , MAXIMUMRRM REVERSE VOLTAGE T = -40°C TO 125°CJ 200 400 600 800 1000 PEAK REPETITIVE 12 1200 85FD(R) VRSM, MAXIMUM PEAK REVERSE VOLTAGE T = 25°C TO 125°CJ CURRENT AT RATED VRRM T = 125°CJ mA 300 500 700 900 1100 1300 NON-REPETITIVE IFM, MAXIMUM PEAK REVERSE T = 25°CJ 0.1 V V
Page 2 of 6www.nellsemi.com FORWARD CONDUCTION PARAMETER SYMBOL UNITTEST CONDITIONS 85FD(R) Maximum average forward current at maximum case temperature IF(AV) 180° conduction, half sine wave IF(RMS)Maximum RMS forward current A 85 ºC 133 A IFRMMaximum peak repetitive forward current 470 Maximum peak, one-cycle non-reptitive surge current IFSM t = 10ms t = 8.3ms t = 10ms t = 8.3ms t = 10ms t = 8.3ms t = 10ms t = 8.3ms 2I t Sinusoidal half wave, 100% VRRM 1100 1151 1308 1369 6050 5498 8554 7778 2A s A A 85543t = 0.1 ms to 10 ms, no voltage reapplied2I √t Maximum l²t for fusing (1)Maximum l²√t for fusing 2A √s Maximum forward voltage drop T = 125°CJ 1.128 V 2.11 VFM T = 25°C; J l = 265A FM 1.75 V Maximum value of threshold voltage VF(TO) rFMaximum value of forward slope resistance reapplied, initial T =T maximum J J (1) 2 2Note : l t for time t =1 tx √ √tx Sinusoidal half wave, 30° conduction mΩ Sinusoidal half wave, no voltage reapplied, initial T =T maximum J J 100% V reapplied,RRM initial T =T maximum J J no voltage reapplied, initial T =T maximum J J SWITCHING 200 PARAMETER SYMBOL UNITTEST CONDITIONS trr 240 08 to 12 85FD(R) 120 ns 500 Typical reverse recovery time T = 25°C, ,J I = 1A to V = 30VF R -dl /dt = 100 A/µsF nC 200 Qrr 340 02 to 06 1300 Typical reverse recovered charge T = 25°C, I = 1A to V = 30V,J F R -dl /dt = 100 A/µsF T = 25°C, -dl /dt = 25 A/µs,J F l = π x rated lFM F(AV) T = 25°C, -dl /dt = 25 A/µs,J F l = x rated lFM F(AV)π 500 85FD(R)Series T = 25°C, J I = 1A, I = 1.0A, F R I = 250mA (RG#1 CKT)RR
THERMAL AND MECHANICAL SPECIFCATIONS PARAMETER SYMBOL UNITSTEST CONDITIONS Maximum junction operating temperature range -40 to125 ºC 0.25 K/W Maximum thermal resistance, junction to case Maximum thermal resistance, case to heatsink 0.30 0.88 (lbf · in) N · mMaximum allowable mounting torque Approximate weight Case style DO-203AB (DO-5) TJ RthJC RthCS g oz. Not lubricated threads, tighting on nut(1) Mounting surface, smooth, flat and greased DC operation JEDEC Maximum storage temperature range Tstg - 40 to150 www.nellsemi.com (1) Note : Recommended for pass-through holes 85FD(R) (1)Lubricated thread, tighting on nut Not lubricated threads, tighting on hexagon(2) Lubricated thread, tighting on (2)hexagon 3.4(30) 2.3(20) 4.2(37) 3.2(28) (2) Recommended for holed threaded heatsinks
- The table above shows the increment of thermal resistance R when devices thJC Note operate at different conduction angles than DC RthJC CONDUCTION CONDUCTION ANGEL SINUSOIDAL CONDUCTION RECTANGULAR CONDUCTION UNITS TEST CONDUCTIONS K/W 180˚ 120˚ 60˚ 30˚ 0.37 0.39 0.82 1.41 0.21 0.37 0.82 1.41 T = 150°CJ 85FD(R) ORDERING INFORMATION SCHEME Diode type Current Polarity 85 = 85A 06 = 600V 08 = 800V
85 FD R 06 A
10 = 1000V R = Reverse, Anode on Stud None = standard, Cathode on Stud Voltage FD = Fast Recovery Diode A = 200 ns Max. B = 500 ns Max. 12 = 1200V (+0%, -10%) 85FD(R)Series
Page 4 of 6www.nellsemi.com 85FD(R)Series Fig.1 Current rating nomogram (Sinusoidal Waveforms) Average forward current (A) Maximum allowable ambient temperature (°C) 0 2 4 6 8 10 12 14 10 20 30 40 50 60 70 80 90 100 Maximum average forward power loss (W) Conduction angle ø ▲▲R K/W 120° 60° 180° 30° 0.39 0.82 0.37 1.41 10 20 30 40 7050 80 1009060 15100 5 85FD(R)Series T = 150°CJ ø Conduction Angle Fig.2 Current rating nomogram (Rectangular waveforms) Maximum average forward power loss (W) Average forward current (A) Maximum allowable ambient temperature (°C) RMS Limit R = 3.0- R K/W thSA 5- R▲ 1.0- R▲1.5- R▲ 8- R▲ 2.0- R▲ 4- R▲120° ø =180° 60° 30° Conduction Angle Conduction angle ø ▲▲R K/W 180° 60° DC 30° 0.21 0.82 1.41 120° 0.37 85FD(R)Series T = 150°CJ 120° ø =180° 60° 30° 2520 Instantaneous forward current (A) Fig. 4 Maximum forward voltage vs. forward current. Instantaneous forward voltage (V) 1 2 3 4 210 310 Fig .3 Maximum high level forward power loss vs. average forward current T = 125°CJ T = 25°CJ 85FD(R)Series 210 310 410 10 210 310 41010 Average forward current (A) Maximum average forward power loss (W) 120° ø =180° 60° 30° 180° ø =DC 120° 60° 30° 85FD(R)Series T = 125°CJ R = 3.0- R K/W thSA 4- R▲ 5- R▲ 6- R▲ 8- R▲ 10- R▲ 15- R▲ 6- R▲ 10- R▲ 15- R▲ 20- R▲ 2.0- R▲ RMS Limit DC
Fig .7 Typical recovered charge vs. rate of fall of forward current. 85FD(R), 200 to 600V T = 125°C J 310 410 210 1 4 10 40 100 Recovered charge (nC) Rate of fall of forward current (A/µs) Page 5 of 6www.nellsemi.com Fig.5 Average forward current vs. maximum allowable case temperature. Maximum allowable case temperature (˚C) 100 110 125 0 20 8040 10060 140 Average forward current (A) Fig .6 Typical reverse recovery time vs. rate of fall of forward current. Rate of fall of forward current (A/µs) Reverse recovery time (ns) 400 210 4 10 40 100 85FD(R), 200 to 600V 410 T = 25°CJ l = 265AF l = 50AF l = 1AF T = 125°CJ l = 265AF l = 50AF l = 1AF l = 265AF l = 50AF l = 1AF Fig .8 Typical reverse recovery time vs. rate of fall of forward current. Rate of fall of forward current (A/µs) Reverse recovery time (ns) 5000 1000 100 200 300 400 4 10 40 100 85FD(R), 800 to 1200V 4000 T = 25°CJ l = 265AF l = 50AF l = 1AF T = 125°CJ l = 265AF l = 50AF l = 1AF Fig .9 Typical recovered charge vs. rate of fall of forward current. 85FD(R), 800 to 1200V T = 25°C J T = 125°C J 210 410 510 310 1 4 10 40 100 Recovered charge (nC) Rate of fall of forward current (A/µs) l = 265AF l = 50AF l = 1AF 85FD(R)Series 120 120° ø =180° 90° 60° 30° ø =180° 60° 30° 120° DC 85FD(R)Series T = 25°C J
Page 6 of 6www.nellsemi.com 19(0.75) 17.3(0.68) 25.4(1.0) (0.37/0.4) 9.4/10.2 1/4” 28UNF-2A For metric devices: M6×1.0 Ø15(Ø0.6) 6.1/6.7 Ø4.3(Ø01.7) (0.03/0.06) 0.9/1.5 85FD(R)..85FD.. DO-203AB (DO-5) 85FD(R)Series AII dimensions in millimeters (inches)