8191403 FESTO

Document overview

  • PDF pages: 2

Technical content

Page 1

Proportional pressure control valve VEAB-L-26-D13-Q4-LK-1R1

Part number: 8191403

PDF page 1 diagram

General operating condition

Data sheet

Feature Value
Valve function 3-way proportional pressure control valve closed
Flow direction Non-reversible
Type of control Direct
Reset method Mechanical spring
Actuation type Electrical
Mounting position Any
Width dimension 18 mm
Sealing principle Soft
Total leakage 1 l/h
Symbol 00995607
Ambient temperature 0 °C ... 50 °C
Temperature of medium 5 °C ... 50 °C
Storage temperature -20 °C ... 70 °C
Relative air humidity 5 - 85 %
Dimensions W x L x H 18 mm x 60.5 mm x 85 mm
Pneumatic connection 1 QS-4
Pneumatic connection 2 QS-4
Pneumatic connection 3 QS-4
Seals material EPDM HNBR NBR
Type of mounting With through-hole With accessories
Inlet pressure 1 MPa 0 MPa ... 0.2 MPa
Inlet pressure 1 0 bar ... 2 bar
Inlet pressure 1 psi 0 psi ... 29 psi
Burst pressure 18 bar
Output pressure 2 -0.1 MPa ... 0.1 MPa
Outlet pressure 2 -1 bar ... 1 bar
Output pressure 2 -14.5 psi ... 14.5 psi
Inlet pressure 3 -0.1 MPa
Inlet pressure 3 -1 bar
Inlet pressure 3 -14.5 psi
Normal nominal flow rate (normalized to DIN 1343) ≥17 l/min
Standard nominal flow rate 2-3 ≥13 l/min

1/19/26 - Subject to change - Festo SE & Co. KG

1/2

Page 2

Feature Value
Linearity 0.25 %FS
Reproducibility 0.2 %FS
Hysteresis 0.25 %FS
Temperature coefficient 0.05 %/K
Overall accuracy 0.5% FS
Product weight 70 g
Operating medium Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas
Information on operating and pilot media Operation with oil lubrication not possible
Nominal altitude of use above sea level < 3000 m NHN
Application note The device was developed, designed and built exclusively for industrial and commercial applications. The device has not been approved for private use.
Degree of protection IP65
Certification RCM compliance mark
KC characters KC EMC
CE marking (see declaration of conformity) As per EU EMC directive As per EU RoHS directive
UKCA marking (see declaration of conformity) To UK instructions for EMC To UK RoHS instructions
Note on materials RoHS-compliant
LABS (PWIS) conformity VDMA24364 zone III
Corrosion resistance class (CRC) 2 - Moderate corrosion stress
DC operating voltage range 18 V ... 30 V
Nominal operating voltage DC 24 V
Max. current consumption 0.083 A
Residual ripple 10 %
Setpoint input IO-Link®
Max. electrical power consumption 1.5 W
Reverse polarity protection for all electrical connections
Short-circuit protection For all electrical connections
Safety instructions Error state VEAB: In the event of an electrical power failure, output pressure is unregulated and may rise or fall – pressure regulator is blocked. The behavior in the event of loss of IO-Link® communication can be parameterized. Factory setting: Pressure
Display type LED
Electrical connection M8x1 Plug as per EN 60947-5-2
Max. cable length 20 m
Housing material PA-reinforced
Vibration resistance Transport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6
Shock resistance Shock test with severity level 2 as per FN 942017-5 and EN 60068-2-27
IO-Link®, number of ports 1
IO-Link®, protocol version Device V 1.1
IO-Link®, device ID 0x03A7
IO-Link®, communication mode COM3 (230.4 kBd)
IO-Link, port type Class A
IO-Link®, Connection technology Device 3-pin
IO-Link®, port class Device A
IO-Link®, minimum cycle time 0.5 ms
IO-Link®, process data width OUT 2 Byte
IO-Link®, process data width IN 2 Byte

1/19/26 - Subject to change - Festo SE & Co. KG

2/2