8170 BELDEN

Document overview

  • PDF pages: 2

Technical content

Page 1

PDF page 1 diagram

Product: 8170

RS232/422 Low Cap, #24-10pr, FPO, Indiv.& O/A Foils+Braid, PVC Jkt, CM,

Product Description

Computer EIA RS-232/422, Digital Audio Cable, 24 AWG stranded (7x32) tinned copper conductors, Datalene® insulation, 10 twisted pairs individually

Beldfoil® shielded + overall 100% Beldfoil® + tinned copper braid shield (65% coverage), drain wire, PVC jacket.

Technical Specifications

Product Overview

RS-232 Extended Distance & RS-422 Applications; Computer Communications; Low Voltage Analog signals (4-20ma, 0-10v, ...); Low Voltage Digital Control (24v, …); Digital

Suitable Applications:

Audio; Panel Wiring

Construction Details

Conductor

Element Number of Element Size Stranding Material
Pair(s) 10 24 AWG 7x32 TC - Tinned Copper

Insulation

Element Material Nom. Thickness Nom. Insulation Diameter Color Code
Pair(s) PE - Polyethylene (Foam) 0.019 in (0.48 mm) 0.061 in (1.5 mm) Black & Red, Black & White, Black & Green, Black & Blue, Black & Yellow, Black & Brown, Black & Orange, Red & White, Red & Green, Red & Blue

Inner Shield

Element Shield Type Material Coverage Drainwire Type Notes
Pair(s) Tape Bi-Laminate (Alum+Poly) 100% 24 AWG (7x32) TC each pair, Z-Fold® Foil-in

Outer Shield

Shield Type Material Coverage
Tape Bi-Laminate (Alum+Poly) 100%
Braid Tinned Copper (TC) 65%

Outer Jacket

Material Nom. Thickness Nom. Diameter
PVC - Polyvinyl Chloride 0.063 in (1.6 mm) 0.584 in (14.8 mm)
Overall Cable Diameter 0.584 in (14.8 mm) (Nominal):

Electrical Characteristics

Electricals

Element Nom. Conductor DCR Max. Conductor DCR Nom. Capacitance Cond-to-Cond Nom. Capacitance Cond-to-Other (Conds + Shield) Nom. Characteristic Impedence Nom. Velocity of Prop. Max. Current
Pair(s) 24 Ohm/1000ft 8.2 Ohm/1000ft 12.5 pF/ft (41.0 pF/m) 22 pF/ft (72 pF/m) 100 Ohm 78% 1.1 Amps per Conductor at 25ºC

Voltage

UL Voltage Rating

300 V (CM), 300 V (UL AWM 2493)

Page 2

Mechanical Characteristics

Temperature

UL Temperature Operating

60°C

-40°C to +60°C

Bend Radius

Stationary Min. Installation Min.
5.8 in (150 mm) 5.8 in (150 mm)
Max. Pull Tension: 225 lbs (102 kg)
Bulk Cable Weight: 148 lbs/1000ft

Standards and Compliance

Environmental Suitability:

Indoor (Not Riser or Plenum), Indoor

Flammability / Reaction to Fire: UL 1685 FT4 Loading, IEC 60332-1-2

CPR Compliance:

CPR Euroclass: Eca

NEC / UL Compliance:

Article 800, CM

AWM Compliance:

AWM 2493

CEC / C(UL) Compliance:

CM

European Directive Compliance: EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)

UK Regulation Compliance:

UKCA Mark

APAC Compliance:

China RoHS II (GB/T 26572-2011)

Product Notes

Datalene® insulation features include low dielectric constant and a dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush

Notes:

resistance and light weight.

History

Update and Revision:

Revision Number: 0.484 Revision Date: 01-20-2023

Part Numbers

Variants

Item # Color Putup Type Length UPC
8170 060100 Chrome Reel 100 ft 612825195788
8170 060500 Chrome Reel 500 ft 612825195801
8170 0601000 Chrome Reel 1,000 ft 612825195795

© 2023 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,

negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product

Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.