EMCA-EC-67-S-1TE-DIO FESTO
Document overview
- PDF pages: 2
Technical content
Page 1
Integrated motor EMCA-EC-67-S-1TE-DIO
Part number: 8061196

Data sheet
| Feature | Value |
| KC characters | KC EMC |
| Type code | EMCA |
| Controller operating mode | PWM MOSFET power output stage Cascade controller with P position controller PI speed controller PI current regulator |
| Rotor position sensor | Absolute encoder, single-turn |
| Rotor position sensor measuring principle | Magnetic |
| Protective function | I²t monitoring Temperature monitoring Current monitoring Voltage failure detection Contouring error monitoring Software end position detection |
| Safety function | Safe torque off (STO) |
| Safety integrity level (SIL) | Safe torque off (STO)/SIL 2 |
| Performance Level (PL) | Safe torque off (STO)/category 3, performance level d |
| Display | LED |
| Max. rotational speed | 3500 1/min |
| Nominal rotary speed | 3100 1/min |
| Braking resistor, external | 6 Ohm |
| Diagnostic coverage | 90 % |
| Characteristics of digital logic outputs | Freely configurable in some cases Not galvanically isolated |
| Hardware fault tolerance | 1 |
| Max. current of digital logic outputs | 100 mA |
| Max. positive test pulse with 0 signal | 10000 µs |
| Max. negative test pulse on 1 signal | 600 µs |
| Motor nominal power | 120 W |
| DC nominal voltage | 24 V |
| Nominal current | 6.9 A |
| Parameterization interface | Ethernet |
| Protocol | Modbus® TCP |
| SFF safe failure fraction | >90 % |
| Max. number of positioning sets | 64 |
| Rotor position sensor resolution | 12 bit |
| Motor peak power | 158 W |
2/9/21 - Subject to change - Festo AG & Co. KG
1/2
Page 2
| Feature | Value |
| Peak current | 10.2 A |
| Permissible voltage fluctuations | +/- 20 % |
| Certificate issuing authority | German Technical Control Board (TÜV) 01/205/5514.00/16 UL E331130 |
| CE marking (see declaration of conformity) | As per EU EMC directive as per EU machinery directive |
| Vibration resistance | Transport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6 |
| Shock resistance | Shock test with severity level 2 as per FN 942017-5 and EN 60068-2-27 |
| Storage temperature | -25 °C ... 70 °C |
| Relative air humidity | 0 - 95 % Non-condensing |
| Degree of protection | IP54 |
| Ambient temperature | 0 °C ... 50 °C |
| Note on ambient temperature | Above an ambient temperature of 20 °C, the power must be reduced by 1.75% per °C. |
| Certification | RCM compliance mark c UL us - Recognized (OL) |
| Rotor mass moment of inertia | 0.175 kgcm² |
| Nominal torque | 0.37 Nm |
| Peak torque | 0.85 Nm |
| Permissible axial shaft load | 60 N |
| Permissible radial shaft load | 100 N |
| PFH | 1.0E-9 |
| PFD | 1.86E-5 |
| Proof test interval | 20 y |
| Product weight | 1900 g |
| Number of digital logic outputs 24 V DC | 4 |
| Number of digital logic inputs | 11 |
| Communication profile | FHPP |
| Logic input specification | Based on IEC 61131-2 |
| Work range of logic input | 24 V |
| Characteristics of logic input | Galvanically connected to logic potential |
| Ethernet, supported protocols | TCP/IP, Modbus® TCP |
| Input switching logic | PNP (positive switching) |
| Switching logic at outputs | PNP (positive switching) |
| Type of mounting | Screwed tightly With through-hole |
| Note on materials | Contains paint-wetting impairment substances RoHS-compliant |
2/9/21 - Subject to change - Festo AG & Co. KG
2/2