74HC86 PHILIPS

Document overview

  • PDF pages: 6

Technical content

Page 1

PDF page 1 diagram

Page 2

PDF page 2 diagram
SYMBOL PARAMETER CONDITIONS TYPICAL UNIT
HC HCT
t / t PHL PLH propagation delay nA, nB to nY C = 15 pF; V = 5 V L CC 11 14 ns
C I input capacitance 3.5 3.5 pF
C PD power dissipation capacitance per gate notes 1 and 2 30 30 pF
PDF page 2 diagram

Page 3

PDF page 3 diagram
PIN NO. SYMBOL NAME AND FUNCTION
1, 4, 9, 12 2, 5, 10, 13 3, 6, 8, 11 7 14 1A to 4A 1B to 4B 1Y to 4Y GND V CC data inputs data inputs data outputs ground (0 V) positive supply voltage
PDF page 3 diagram

Page 4

PDF page 4 diagram
PDF page 4 diagram
INPUTS OUTPUTS
nA nB nY
L L H H L H L H L H H L
PDF page 4 diagram

Page 5

PDF page 5 diagram
PDF page 5 diagram
PDF page 5 diagram
INPUT UNIT LOAD COEFFICIENT
nA, nB 1.0
PDF page 5 diagram
SYMBOL PARAMETER T (°C) amb UNIT TEST CONDITIONS
74HCT V CC (V) WAVEFORMS
+25 −40 to +85 −40 to +125
min. typ. max. min. max. min. max.
t / t PHL PLH propagation delay nA, nB to nY 17 32 40 48 ns 4.5 Fig.6
t / t THL TLH output transition time 7 15 19 22 ns 4.5 Fig.6
PDF page 5 diagram

Page 6

PDF page 6 diagram