74ACT11112 TI
Document overview
- Manufacturer or author: Provided By digicamel.com
- PDF pages: 5
Technical content
DUAL J-K NEGATIVE-EDGE-TRIGGERED FLIP-FLOP WITH CLEAR AND PRESET SCAS064A – D3339, JUNE 1989 – REVISED APRIL 1993 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 Copyright 1993, Texas Instruments Incorporated 2–1
- Inputs Are TTL-Voltage Compatible
- Fully Buffered to Offer Maximum Isolation From External Disturbance
- Flow-Through Architecture Optimizes PCB Layout
- Center-Pin VCC and GND Configurations Minimize High-Speed Switching Noise
- EPIC/C0116 (Enhanced-Performance Implanted CMOS) 1-/C0109m Process
- 500-mA Typical Latch-Up Immunity at 125°C
- Package Options Include Plastic Small-Outline Packages and Standard Plastic 300-mil DIPs
description
This device contains two independent J-K negative-edge-triggered flip-flops. A low level at the PRE or CLR input sets or resets the outputs regardless of the levels of the other inputs. When PRE and CLR are inactive (high), data at the J and K inputs meeting the setup time requirements are transferred to the outputs on the negative-going edge of the clock pulse. Clock triggering occurs at a voltage level and is not directly related to the fall time of the clock pulse. Following the hold-time interval, data at the J and K inputs may be changed without affecting the levels at the outputs. These versatile flip-flops can perform as toggle flip-flops by tying J and K high. The 74ACT11112 is characterized for operation from – 40°C to 85°C. FUNCTION TABLE INPUTS OUTPUTS PRE CLR CLK J K Q Q L H X X X H L H LX X X L H L LX X X H /C0123H /C0123 H H ↓ LL Q 0 Q 0 H H ↓ HLH L H H ↓ LHL H H H ↓ H H TOGGLE H H H X X Q 0 Q 0 † This configuration is nonstable; that is, it will not persist when either PRE or CLR returns to the inactive (high) level. D OR N PACKAGE (TOP VIEW) 1PRE GND 2PRE 1CLK 1CLR VCC 2CLR 2CLK EPIC is a trademark of Texas Instruments Incorporated. PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
DUAL J-K NEGATIVE-EDGE-TRIGGERED FLIP-FLOP WITH CLEAR AND PRESET SCAS064A – D3339, JUNE 1989 – REVISED APRIL 1993 POST OFFICE BOX 655303 • DALLAS, TEXAS 752652–2 logic symbol†
2 CLR
2 PRE
1 CLK
1 PRE
1 CLR
S R 1J1J 112K S R † This symbol is in accordnace with ANSI/IEEE Std 91-1984 and IEC Publication 617-42. logic diagram, each flip-flop (positive logic) TGTG TG C C C C Q C C PRE J K CLK CLR C C C C Q TG absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡ ‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute maximum rated conditions for extended periods may affect device reliability. NOTE 1: The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
DUAL J-K NEGATIVE-EDGE-TRIGGERED FLIP-FLOP WITH CLEAR AND PRESET SCAS064A – D3339, JUNE 1989 – REVISED APRIL 1993 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 2–3 recommended operating conditions MIN MAX UNIT VCC Supply voltage 4.5 5.5 V VIH High-level input voltage 2 V VIL Low-level input voltage 0.8 V VI Input voltage 0 VCC V VO Output voltage 0 VCC V IOH High-level output current –24 mA IOL Low-level output current 24 mA /C0068t//C0068v Input transition rise or fall rate 0 10 ns/V TA Operating free-air temperature –4 0 85 °C electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS VCC TA = 25°C MIN MAX UNITPARAMETER TEST CONDITIONS VCC MIN TYP MAX MIN MAX UNIT IOH =5 0 /C0109A 4.5 V 4.4 4.4 IOH = –50 /C0109A 5.5 V 5.4 5.4 VOH IOH =2 4 m A 4.5 V 3.94 3.8 V IOH = –24 mA 5.5 V 4.94 4.8 IOH = – 75 mA† 5.5 V 3.85 IOL =5 0/C0109A 4.5 V 0.1 0.1 IOL = 50 /C0109A 5.5 V 0.1 0.1 VOL IOL =2 4m A 4.5 V 0.36 0.44 V IOL = 24 mA 5.5 V 0.36 0.44 IOL = 75 mA† 5.5 V 1.65 II VI = VCC or GND 5.5 V ± 0.1 ±1 /C0109A ICC VI = VCC or GND, I O = 0 5.5 V 4 40 /C0109A /C0068ICC ‡ VI = VCC or GND 5.5 V 0.9 1 mA C i VI = VCC or GND 5 V 3.5 pF † Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms. ‡ This parameter is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC . timing requirements over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) (see Figure 1) TA = 25°C MIN MAX UNIT MIN MAX MIN MAX UNIT fclock Clock frequency 125 125 MHz t Pulse duration PRE or CLR low 4 4 nstw Pulse duration CLK high or low 4 4 ns t Setup time before CLK↓ Data high or low 3.5 4.5 nstsu Setup time before CLK ↓ PRE or CLR inactive 2 2 ns th Hold time after CLK↓ 1.5 1.5 ns
NOTES: A. C L includes probe and jig capacitance. B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 W , tr = 3 ns, tf = 3 ns. C. The outputs are measured one at a time with one input transition per measurement. Figure 1. Load Circuit and Voltage Waveforms
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER’S RISK. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof. Copyright 1998, Texas Instruments Incorporated