Bezeichnung : description : Gehäuse / case: LV a 26,5 max mm b 18,5 max mm c 30,5 max mm d 12,5 ± 0,2 mm e 15,0 ± 0,2 mm f 3,0 ± 0,5 mm ø 0,6 x 0,6 typ mm @@FR M 1@@ Eigenschaften / properties Wert / value Einheit / unit tol. Leerlauf-Induktivität / inductance DC-Widerstand / DC-resistance Nennstrom / nominal current Nennspannung / nominal voltage 33% +25° C
1500 V,50 Hz
Name Änderung / modification Datum / date Freigabe erteilt / general release: Kunde / customer Würth Elektronik HP 34401 A für/for I N und/and R DC Umgebungstemperatur / temperature: UL94V-0 P155 IEC317-20 F Werkstoffe & Zulassungen / material & approvals: G Eigenschaften / general specifications: C Lötpad / soldering spec.: B Elektrische Eigenschaften / electrical properties: 250 50 Hz mH RDC http://www.we-online.com Datum / date Unterschrift / signature Kontrolliert / approved Würth Elektronik eiSos GmbH & Co. KG D-74638 · Max-Eyth-Strasse 1 - 3 · Germany · Telefon (+49) (0) 7942 - 945 - 0 · Telefax (+49) (0) 7942 - 945 - 400 Geprüft / checked Spezifikation für Freigabe / specification for release DATUM / DATE : 2012-08-07 max. A Testbedingungen / test conditions 1.9 UL94V-0 Klimabeständigkeit/ climatic class: 40/125/21 Verguß / molding: Betriebstemp. / operating temperature: -40° C - + 125° C Übertemperatur / temperature rise: < 55 K LO 6.8 Gehäuse / case: Draht / wire: Kunde / customer : STROMKOMPENSIERTE DROSSEL WE-LF CURRENT-COMPENSATED CHOKE WE-LF Artikelnummer / part number : 0.160 7446322007 A Mechanische Abmessungen / dimensions: 10 kHz / 50 mV / 25° C ±30% FLUKE PM 6306 für/for L 0/L N UN IN Luftfeuchtigkeit / humidity: D Prüfgeräte / test equipment: E Testbedingungen / test conditions: not exceed 125° C under worst case operating conditions. V Ω Prüfspannung / testing voltage It is recommended that the temperature of the part does This electronic component has been designed and developed for usage in general electronic equipment. Before inco rporating this component into any equipment where high er safety and reliability is especially required or if there is the possibility of dire ct damage or injury to human body, for example in the range of aerospace, aviation, nuclear control, submarine , transportation, (automotive control, train control, ship control), transportation signal, disa ster prevention, medical, public information network et c, Würth Elektronik eiSos GmbH must be informed before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be p erformed on every electronic component which is used in el ectrical circuits that require high safety and reliabilit y functions or performance. f 1 4 2 3 Ø LF SEITE 1 VON 1