70RCK4 GRAYHILL
Document overview
- Manufacturer or author: Provided By digicamel.com
- PDF pages: 2
Technical content
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.gra yhill.com System 50 System 50 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 B AC OUTPUT R DC OUTPUT Y AC INPUT W DC INPUT STANDOFF I.D. 0.15 ( 3,8),DIA. (4 PLACES) CLEARANCE FOR #6 SCREW 9 POSITION TERMINAL STRIP FOR GROUND AND LOGIC SIGNALS 3.00 (76,2) 3.50 (88,9) 4.00 (101,6) 4.50 (114,3) STATUS LED 3.3K RESISTOR
5 AMP FUSE
2.20 (55,9) MAX. 0.75 (19,1) MODULE SHOWN FOR REFERENCE ONLY NOTE: MAXIMUM TERMINAL SCREW TORQUE NOT TO EXCEED 5 IN-LBS.
4 CHANNEL RACK: G5
Part No. 70RCK4 Dimensions are shown in inches (and millimeters). All tolerances are ± 0.010 (0,25) unless otherwise specified.
4 CHANNEL RACK: Standard
4 Channel
FEATURES
Use for Isolating and Coverting Signal Types to Standard Logic Voltages Terminal Block Connection for Input and Output Available for Standard and G5 I/O Modules Panel and DIN Rail Mount Versions UL, CSA Certified System 50 B R Y W AC OUTPUT DC OUTPUT AC INTPUT DC INTPUT 1 2 3 4 5 6 7 8 9 9 8 7 6 5 4 3 2 1 2.75 (69,85) 3.25 (82,55) 2.75 (69,85) .76 (19,30) 4.27 (108,46) .25 (6,35) SWAGED STANDOFF THRU HOLE .15 (3,81) DIA. (4 PLACES) (CLEARANCE FOR #6 SCREW)
9 POSITION
3.36 5,34) .75 (19,05) 4.00 (101,6) 4.70 (119,38) DIN-RAIL CARRIER NOTE: MAXIMUM TERMINAL SCREW TORQUE NOT TO EXCEED 5 IN-LBS. Part No. 70GRCK4 Dimensions are shown in inches (and millimeters). All tolerances are ± 0.010 (0,25) unless otherwise specified.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.gra yhill.com System 50 System 50 70RCK4 For Negative True Logic Only SCHEMATICS: Part No. 70RCK4 SCHEMATICS: Part No. 70GRCK4 70GRCK4 and 70GRCK4-DIN For Negative True Logic Only 70RCK4R For Negative or Positive True Logic Part Number I/O Description UL CSA Style 70RCK4 4 Negative true logic X X Standard 70RCK4R 4 Positive or negative true logic* X X Standard 70GRCK4 4 Negative true logic X X G5 70GRCK4R 4 Positive or negative true logic* X X G5 70GRCK4-DIN 4 Negative true logic– DIN rail mount XX G 5 70GRCK4R-DIN 4 Positive or negative true logic*– X X G5 DIN rail mount *Note: Positive True Logic applies to output modules only. ORDERING INFORMATION (modules ordered separately) 70GRCK4R and 70GRCK4R-DIN For Negative or Postive True Logic Available from your local Grayhill Distribu- tor. For prices and discounts, contact a local Sales Office, an authorized local Distributor, or Grayhill. System 50 1 2 3 4 5 6 7 8 9 0 1 2 3 1 2 3 4 5 6 7 8 9 MODULE POSITION FIELD WIRING TERMINAL STRIP N/C 3.3K +VCC GND LOGIC GND LOGIC GND LOGIC GND LOGIC FUSE TERMINAL STRIP FOR LOGIC AND GROUND SIGNALS 1 2 3 4 5 6 7 8 9 0 1 2 3 1 2 3 4 5 6 7 8 9 MODULE POSITION TERMINAL STRIP FOR LOGIC AND GROUND SIGNALS FIELD WIRING TERMINAL STRIP N/C 3.3K FUSE GND +VCC LOGIC +VCC LOGIC +VCC LOGIC +VCC LOGIC BARRIER STRIP FOR FIELD WIRING OF MODULE MODULE LOCATION0 1 2 3 CONTROL BARRIER STRIP PULL-UP RESISTOR 3.3 KΩ 1 2 3 4 5 6 7 8 9NC 1 2 3 4 5 6 7 8 9GROUND +VCC LOGIC +VCC LOGIC +VCC LOGIC +VCC LOGIC BARRIER STRIP FOR FIELD WIRING OF MODULE INPUT/OUTPUT MODULE LOCATION0 1 2 3 CONTROL BARRIER STRIP PULL-UP RESISTOR 3.3 KΩ 1 2 3 4 5 6 7 8 9NC 1 2 3 4 5 6 7 8 9+VCC GND LOGIC GND LOGIC GND LOGIC GND LOGIC