Overview/Product Selection Bulletin 700-SF 3 A (resistive) Max. Continuous Load (Output) Current 264V AC or 52.8V DC Max. Load Voltage Range 4…24V DC Control/Input Voltage Photocoupler or Phototriac Isolation Option Between Control and Output Voltage LED Indicator for Input/Logic ON/OFF Status Monitoring 700-HN116 Socket Compatible Table Of Contents Approximate Input-to-Output Isolation Method Zero Cross Function LED Indicator Rated Output (Load) Max. Current and Voltage Range Rated Input Control Voltage Cat. No. Factory- stocked Item (Single Pack) Photocoupler Yes 3 A at 100…240V AC 5…24V DC 700-SFZY3Z25 ✔ Phototriac No 24V DC 700-SFTY3Z24 ✔ Photocoupler N/A Yes 3 A at 4…48V DC 4…24V DC 700-SFNY3Z25 ✔
➊ Bulletin 700-SF must use 700-HN114 series B retainer clip. Description Pkg. Qty. Cat. No. Factory- stocked Item Screw Terminal Socket — Panel or DIN Rail Mounting 8-blade miniature socket for use with DPDT HF relays. Order must be for 10 sockets or multiples of 10. 10 700-HN116 ✔ DIN Rail Mounting Pack Standard 35 x 7.5 mm DIN Rail, 1 meter long, 10 rails per package. Order must be for 10 rails or multiples of 10. 10 199-DR1 ✔ Pre-printed identification tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F , R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 700-N40 ✔ Blank identification tags — contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 700-N41 ✔ Retainer Clip for Cat. No. 700-HN103 and -HN128 Sockets with 700-SF Relays and Cat. No. 700-HN116 Sockets Secures relay in socket. Order must be for 10 clips or multiples of 10. 10 700-HN114B➊✔ Cat. No 700-HN116 Cat No. 199-DR1 Sample Retainer Clips
➊ With constant current input circuit system, SSR impedance varies with a change in input voltage. ➋ Input impedance reaches its maximum at the operating voltage. ➌ If the SSR operation is continuous ON/OFF , this value should be reduced by 50%. Refer to the “Inrush Current Resistivity” graphs on page 50 for more details. ➍ Refer to "Load Current vs. Ambient Temperature Characteristics" on page 50 for additional load current details. Control/Input Ratings Cat. No. Rated Control Voltage Operating Control Voltage Range Impedance Control Voltage Levels Pick-up Voltage Drop-out Voltage 700-SFZY3Z25 5…24V DC 4…28V DC 15 mA max. ➊ 4V DC max. 1V DC min. 700-SFNY3Z25 5…24V DC 4…28V DC 1.5 k Ω + 20%/–10% ➋ 4V DC max. 1V DC min. Load/Output Ratings Cat. No. Applicable Load Rated Load Voltage Load Voltage Range Continuous Load Current (Resistive) Max. Inrush Current ➌ — — — Min. Max. ➍ — 700-SFZY3Z25 100…240V AC 75…264V AC 0.1 A 3 A 45 A @50/60 Hz, 1 cycle700-SFTY3Z24 0.1 A 3 A 700-SFNY3Z25 4…48V DC 3…52.8V DC 0.1 A 3 A 18 A (10 ms) Characteristics Load Switching Method/Device Triac Transistor Pick-up time 1/2 cycle of load power source + 1 ms max. 1 ms max. 0.5 ms max. Drop-out time 1/2 of output switching element cycle of load power source + 1 ms max. 2 ms max. Output ON voltage drop 1.6V (RMS) max. 1.5V max. Output Leakage current 5 mA max. (at 100V AC); 10 mA max. (at 200V AC) 2.5 mA max. (at 100V AC); 5 mA max. (at 200V AC) 5 mA max. (at 50V DC) Output VDRM VCEO (V) 600 600 80 Output di/dt (A/uS) 50 50 — Output dv/dt (V/uS) 250 250 — Output I2t (A2S) 18 18 — Output Tj (°C) (max.) 125 125 150 Insulation resistance 100 M Ω min. (at 500V DC) Dielectric strength 1,500V AC, 50/60 Hz for 1 min. Vibration resistance (max.) 10…55 Hz , 1.5 mm double amplitude (10 G) Shock resistance (max.) 1,000 m/s 2 (100 G) Ambient temperature Operating: –30…80 °C (–22…176 °F) with no icing or condensation Storage: –30…100 °C (–22…212 °F) with no icing or condensation Ambient humidity 45…85% (no condensation) Standards UL508, CSA C22.2, CE Weight Approx. 50 g
Specifications, Continued/Approximate Dimensions Note: These data are non-repetitive. Keep the inrush current to half the rated value if it occurs repetitively. Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR. ➊ Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR. Approximate Dimensions All units are in millimeters unless otherwise indicated. Dimensions are not intended for manufacturing purposes. Note: The 700-SF is compatible with the 700-HN116 socket. Basic Application Considerations of Bulletin 700-SF High Density Mounting of Multiple SSRs If multiple SSRs are mounted side by side be aware that the outer case wall of the SSR acts as a radiator. The SSR case serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half. Connection For DC load switching, the 700-SF SSR will operate properly if the load is connected to either the positive or negative load t erminals. Protective Component To Extend SSR Life When controlling AC inductive loads, connect an inrush/surge absor bing device (varistor) across the SSR load terminals. If the SSR has built-in surge suppression (Bulletins 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device . Select a varistor that meets the conditions of the load voltage outlined in the table below. Note: For additional details applying solid-state relays, refer to pub. number 700-AT001A-EN-E, Solid-State Relay Application Guide. Document available at http://www.theautomationbookstore.com. Load Voltage Varistor Voltage Varistor Surge Resistance 100…120V AC 240…270 V 1000 A min.200…240V AC 440…470 V 380…480V AC 820…1000 V 700-SF Ambient temperature (°C) Load current (A) 700-SFZ… 700-SFT…Inrush current (A, Peak) Energizing time (ms) Energizing time (ms) 700-SFN… Inrush current (A) Load Current vs. Ambient Temperature Characteristics Inrush Current Resistivity ➊ Inrush Current Resistivity ➊ Terminal Arrangement/ Internal Connections (Bottom V iew) 4(+) 6(–) – + – + (+) (–) Input Load Load Input voltage Note: 1. The plus and minus symbols shown in the parentheses are for DC loads. 2. The coil has no polarity. 28 max. 21.5 max. 36.5 max. 42.5 max.