6009.1315 SCHURTER

Document overview

  • Manufacturer or author: Provided By digicamel.com
  • PDF pages: 3

Technical content

Cord Sets 6009.1315https://www.schurter.com /PG07 Connectors US Power Supply Cord with IEC Connector C13, straight See below: Approvals and Compliances C13 70° C NEMA 5-15

Description

  • 1 Function : - Power Cord , Protection class I - Pin temperature 60 °C - custom specific versions on request Technical Data Ratings UL/CSA 10 A / 125 VAC; 50/60 Hz Allowable Operation Tempe- rature -40 °C to 60 °C IP-Protection from front side IP 40 acc. to IEC 60529 Insulation cover Suitable for appliances with protection class I acc. to IEC 61140 Material: Housing PVC, black appliance inlet/-outlet C13 acc. to UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: Approval Logo Certificates Certification Body Description UL Approvals UL UL File Number: CSA Approvals CSA CSA Certification Record: Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment.

Cord Sets6009.1315 https://www.schurter.com /PG07 Connectors Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. All Variants Connector cable Plug Order Number Type V-Lock Cord Type Conductor cross section Length [m] Color Type Country Standard Style C13 SJT 3x18 AWG 3 x 18 AWG 2.5 black North America USA NEMA 5-15 straight - 6009.1315 █ Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Packaging unit 50 Pcs Mating Inlets/Plugs Category / Description Appliance Inlet Overview complete 6100-3, Mounting: Screw, Solder terminals or quick connect terminals, Appliance Inlet: IEC C14 6100-3 6100-4, Mounting: Snap-in, Solder terminals or quick connect terminals, Appliance Inlet: IEC C14 6100-4 6102-3, Mounting: Screw, Solder terminals or quick connect terminals, Appliance Inlet: IEC C18 6102-3 6102-5, Mounting: Snap-in, Solder terminals or quick connect terminals, Appliance Inlet: IEC C18 6102-5 G-Stecker, Mounting: Appliance Inlet : IEC C14 Without fuse holder 6150 Appliance Inlet further types to 6009.1315 ... Distribution Unit Overview complete Distribution Unit for Snap-in Mounting with 1 IEC Appliance Inlet C14 and 1 Appliance Outlet F 0712 Distribution Unit with 1 IEC Appliance Inlet C14 and 2 Appliance Outlets F, Shuttered 4741 Distribution Unit with 1 IEC Appliance Inlet C14 and 4 Appliance Outlets F 4747 Distribution Unit with 1 IEC Appliance Inlet C14 or Power Cord, 4, 5 or 6 IEC Appliance Outlets F and Extra Components 4740 Distribution Unit further types to 6009.1315 IEC Inlet Filter Overview complete 5123, Mounting: Screw, Front-/Rear-Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Themoplast / steel tin-plated Appliance Inlet: IEC C14, Suitable for appliances with protection class I or II 5123 GRF2, Mounting: Rear Side, With EMC-shield and without line filter, 10 A, Plug Connector, Appliance Inlet: IEC C14, Suitable for appliances with protection class I GRF2 5110, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Thermoplastic Appliance Inlet: IEC C14, prewired, Suitable for appliances with protection class I 5110 5120, Mounting: Screw with plastic flange, Front-/Rear-Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Themoplast / steel tin-plated Appliance Inlet: IEC C14, Suitable for appliances with protection class I or II 5120 5150, Mounting: Screw, Front-/Rear-Side, Filter: Standard, medical and industrial version, Without fuse holder: 10 A, Themoplast / steel tin-plated Appliance Inlet: IEC C14, Suitable for appliances with protection class I 5150 IEC Inlet Filter further types to 6009.1315 ...

Cord Sets 6009.1315https://www.schurter.com /PG07 Connectors Category / Description Plug Overview complete IEC Plug E, Cord Connector (Rewireable), Straight, max. cable Diameter 8.5 mm 4732 IEC Plug E, Cord Connector (Rewireable), Straight, max. Cable Diameter 10 mm 4735 IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 8.5 mm 4733 IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 10 mm 4736 IEC Plug E, Cord Connector (Rewireable), Angled P685 Plug further types to 6009.1315 Power Entry Module Overview complete DD11, Mounting: Screw-on mounting, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals 4.8 x 0.8 mm, Appliance Inlet: IEC C14, With or without protection cover, Fuse holder: 1 or 2 pole, Suitable for appli- ances with protection class I DD11 DD21, Mounting: Screw-on mounting Rear Side, Rocker switch: non-illuminated or illuminated 2-pole, additional quick connect 4.8 x 0.8 mm Appliance Inlet: IEC C14, Fuse holder: 1 or 2 pole DD21 DC11, Mounting: Screw, Rocker switch: non-illuminated or illuminated 1 or 2 pole, Quick connect terminals 4.8 x 0.8 mm, Appliance Inlet: IEC C14, Without fuse holder: Suitable for appliances with protection class I or II DC11 KEB1, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Without fuse holder: Rocker switch, non-illuminated or illuminated, red, 1-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I KEB1 KEB2, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Without fuse holder: Rocker switch, non-illuminated or illuminated, 2-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I KEB2 Power Entry Module further types to 6009.1315 ... Power Entry Module with line filter Overview complete KFB1, Mounting: Screw, Front Side, Filter: Standard Version, Without fuse holder: 10 A, Rocker switch: 1-pole, Appli- ance Inlet: IEC C14, prewired KFB1 Mounting: Screw, from rear-side, A, Filter: Standard Version, Rocker switch: 2-pole, non-illuminated, : IEC C14, Suitable for appliances with protection class I or II DA22 KFB2, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Rocker switch: 2-pole, Appliance Inlet: IEC C14, prewired KFB2 DC12, Mounting: Screw, Front-/Rear-Side, Filter, Standard and Medical Version, Without fuse holder:10 A, Rocker switch: 1 or 2 pole, non-illuminated or illuminated Appliance Inlet: IEC C14, prewired DC12 DC22 Mounting: Screw, Rear Side, PCB, 10 A, Filter: Standard and Medical Version, Without fuse holder: Rocker switch: 1 or 2 pole, non-illuminated or illuminated, Appliance Inlet: IEC C14, Suitable for appliances with protection class I DC22 Power Entry Module with line filter further types to 6009.1315 ... The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 12.02.2018