55PC0213 TEC

Document overview

  • Manufacturer or author: Provided By digicamel.com
  • PDF pages: 2

Technical content

Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. Page 1 of 2 The TE logo, Tyco Electronics and Raychem are trademarks. Raychem Wire & Cable

501 Oakside Avenue

Redwood City, CA 94063-3800 Phone: 1-800-227-8816 Fax: 1-650-361-6297 DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. © 2010 Tyco Electronics Corporation. All rights reserved. CONDUCTOR - NICKEL-COATED COPPER INSULATION - RADIATION - CROSSLINKED, MODIFIED ETFE TITLE SPECIFICATION CONTROL DRAWING 55PC0213 WIRE, RADIATION-CROSSLINKED, MODIFIED ETFE-INSULATED, MEDIUM WEIGHT, GENERAL PURPOSE, 600 VOLT 2-1-10 F This specification sheet forms a part of the latest issue of Raychem Specification 55PC. Date Revision CONSTRUCTION DETAILS PART NUMBER WIRE SIZE (AWG) CONDUCTOR STRANDING (number x AWG) CONDUCTOR DIAMETER (in.) FINISHED WIRE MAXIMUM RESISTANCE AT 20°C (ohms/1000 ft.) DIAMETER (in.) WEIGHT (lbs/1000 ft.) LOWER SPEC LIMIT TARGET VALUE UPPER SPEC LIMIT LOWER SPEC LIMIT TARGET VALUE UPPER SPEC LIMIT TARGET VALUE UPPER SPEC LIMIT

WIRE RATINGS AND ADDITIONAL REQUIREMENTS Revision SPECIFICATION CONTROL DRAWING Page 2 of 2 F 55PC0213 SCD TEMPERATURE RATING: 200°C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level COLOR: White preferred CROSSLINK VERIFICATION: 300 ± 3°C for 1 hour IDENTIFICATION AND COLOR STRIPING DURABILITY: 125 cycles (250 strokes) (minimum). 500 g weight. INSULATION ELONGATION AND TENSILE STRENGTH: Total Insulation, Elongation, 50% (minimum) Tensile Strength, 5000 lbf/in² (minimum) INSULATION FLAWS: Spark Test, 3.0 kV (rms) Impulse Dielectric Test, 8.0 kV (peak) INSULATION THICKNESS: .008 in. (nominal) total insulation SHRINKAGE: 230 ± 3°C for 1 hour, 0.125 inch (maximum) in 12 inches. VOLTAGE WITHSTAND TEST (Post Environmental): 2500 volts (rms) PART NUMBER: The “*” in the part numbers on page 1 shall be replaced by a color code designator, 1/ Example: AWG 22, white: 55PC0213-22-9 AWG 22, white with black stripe: 55PC0213-22-90 1/ See footer section on page 1