573945 ETC2

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

NEW GENERATION ® CABLES 20.37 20 • New Generation Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com Security Coaxial Cable Surveillance and CCTV Applications Shielded or Flooded for Use in Underground Ducts Coax (NEC CM and CEC CM FT1) Mini RG-59 Type BC BC 1000 305 14.0 6.4 RG-59 Type BC BC 1000 305 30.0 13.6 BC BC 500 152 13.0 6.0 U-1000 U-305 25.0 11.3 1000 305 31.0 14.1 RG-6 Type BC BC U-1000 U-305 40.0 18.1 1000 305 41.0 18.6 RG-11 Type BC BC 1000 305 98.0 44.5 Water-blocked Coax (NEC CM and CEC CM FT1) RG-59 Type BC + 95% 500 152 17.5 7.9 tinned copper U-1000 U-305 34.0 15.4 braid 1000 305 34.0 15.4 RG-6 Type BC + 60% 500 152 15.5 7.0 aluminum U-1000 U-305 30.0 13.6 braid 1000 305 30.0 13.6 BC = Bare Copper *Available in other jacket colors. Consult www.belden.com. Shield/ Braid Coverage Stranding and Conductor AWGPart No. mFt. Standard Lengths mmInch kg Standard Unit Weight Insulation Nominal OD Nominal OD Inch mm Lbs. CoreGuard Coax CM FT1 Rated Product Description Bare copper conductor, foam polyethylene insulation, bare copper braid shield. Black PVC jacket. Sequential footage marking every two feet. Water-blocked Coax CM FT1 Rated Product Description Bare copper conductor, foam polyolefin insulation, foil plus braid shield as shown per item, braid impregnated with CoreGuard ® flame retardant flooding compound, Black UV resistant PVC jacket. Sequential footage marking every two feet. Specifications Conductor Bare Copper Insulation FPE Shield Coax Bare Copper Braid Water-blocked Coax Foil + Braid Jacket PVC Approvals NEC CM CEC CM FT1 NEC Articles 800 Nominal Impedance 75Ω Temperature Rating 75°C

Applications

  • CCTV
  • Video Security Coax Solid Conductor Stranded Conductor Water-blocked

NEW GENERATION ® CABLES 20.38 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com Security Composite Cable CCTV plus Audio or Power or Pan and Tilt CCTV Control Applications Plenum-Rated and Non-Plenum Shield/ Braid Coverage Stranding and Conductor AWGPart No. CM-Rated Composite (NEC CM and CEC CM FT1) Mini RG-59 Type u 20(pr) 7/w BC unshielded .056 1.42 xx 1000 305 29.0 13.2 .332 8.43 RG-59 Type 18(pr) 7/w BC unshielded .066 1.68 xx 1000 305 60.0 27.3 .460 11.68 RG-6 Type 18(pr) 7/w BC unshielded .066 1.68 xx 1000 305 69.0 31.3 .500 12.70 CMG-LS -Rated Composite (NEC CMG-LS and CEC CMG-LS FT4 Limited Smoke) RG-6 Type u 18(pr) 7/w BC unshielded .059 1.59 xx 1000 305 76.0 34.5 .514 13.06 Plenum-Rated Composite (NEC CMP and CEC CMP FT6) Mini RG-59 Type u 20(pr) 7/w BC unshielded .048 1.22 xx 1000 305 34.0 15.5 .328 8.33 RG-59 Type 18(pr) 7/w BC unshielded .059 1.50 xx 1000 305 54.0 24.5 .383 9.72 RG-6 Type 18(pr) 7/w BC unshielded .059 1.50 xx 1000 305 60.0 27.2 .416 10.57 BC = Bare Copper • cx = Coax • pr = Pair • LSZH = Low-Smoke, Zero-Halogen *679948 also available in White. mFt. Standard Lengths mmInch kg Standard Unit Weight Insulation Nominal OD Nominal OD Inch mm Lbs. Non-Plenum Composite Coax plus Twisted Pair CM FT1 or CMG-LS FT4 Rated Product Description Coax: Solid bare copper conductor, foam polyolefin insulation, bare copper braid shield. Black PVC jacket (1306SB has Black LSZH jacket). Pair: Stranded bare copper conductor, PVC insulation, Black PVC jacket. (1306SB has polypropylene insulation. Black LSZH jacket.) Color coded: Black & Red. Plenum-Rated Composite Coax plus Twisted Pair CMP FT6 Rated Product Description Coax: Solid bare copper conductor, FEP insulation, bare copper braid shield, Natural Flamarrest® jacket. Pair: Stranded FEP insulation, Natural Flamarrest jacket.Color coded: Black & Red. Coax and pair in Siamese configuration. Sequential footage marking every two feet. Specifications Conductor Bare Copper Insulation (Non-Plenum) Coax FPO Pair PVC Insulation (Plenum) FEP Shield (Coax) Bare Copper Braid Jacket Non-Plenum PVC Plenum Flamarrest Approvals (Non-Plenum) NEC CM CEC CM FT1 Approvals (LSZH) NEC CMG-LS CEC CMG-LS FT4 Limited Smoke Approvals (Plenum) NEC CMP CEC CMP FT6 NEC Articles 800 Nominal Impedance (Coax) 75 Ω Temperature Rating 75°C

  • CCTV plus Audio or Power
  • Pan, Tilt and Zoom CCTV Control

NEW GENERATION ® CABLES 20.39 20 • New Generation Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com Security Coaxial Cable CCTV and Card Reader/Sensor Applications Plenum-Rated Plenum-Rated Coax for CCTV (NEC CMP and CEC CMP FT6) Mini RG-59 Type BC BC U-1000 U-305 17.0 7.7 1000 305 17.0 7.7 RG-59 Type BC BC 500 152 17.5 8.0 U-1000 U-305 30.0 13.6 1000 305 32.0 14.5 RG-6 Type BC BC 500 152 20.5 9.8 U-1000 U-305 40.0 18.1 1000 305 42.0 19.1 RG-11 Type BC BC 1000 305 90.0 40.9 *643948 also available in Black jacket. Plenum-Rated Coax for Card Readers/Sensors (NEC CMP, CEC CMP FT6) RG-62 Type BCCS BC 1000 305 33.0 15.0 BC = Bare Copper • BCCS = Bare Copper-covered Steel Shield/ Braid Coverage Stranding and Conductor AWGPart No. mFt. Standard Lengths mmInch kg Standard Unit Weight Insulation Nominal OD Nominal OD Inch mm Lbs. Plenum-Rated Coax CMP FT6 Rated Product Description Bare copper or copper-covered steel conductor, foam FEP insulation, bare copper braid shield. Natural Flamarrest ® jacket (except 613948 which is White fluorocopolymer). Sequential footage marking every two feet. Specifications Conductor Solid BC or BCCS Insulation Foam FEP Shield Bare Copper Braid Jacket Flamarrest† Approvals NEC CMP CEC CMP FT6 NEC Articles 800 Nominal Impedance 75Ω Nominal Impedance (6539Y8 only) 93 Ω Temperature Rating 75°C †613948 jacket is White fluorocopolymer.

  • CCTV
  • Card Reader/Sensor (6539Y8)

CCTV Fixed and PTZ Applications Riser-Rated NEW GENERATION ® CABLES 20.40 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com Non-Plenum CM FT1 or CMR FT4 Rated Product Description Solid bare copper conductors, unshielded twisted pairs, polyolefin insulation, PVC jacket with rip cord. Sequential footagemarking every two feet. Specifications Conductor Solid Bare Copper Shield Unshielded Jacket PVC Approvals NEC CM or CMR CEC CM FT1 or CMR FT4 Nominal Impedance 100Ω Temperature Rating 80°C Applications:

  • 100BaseTX
  • 100BaseVG ANYLAN
  • 155ATM
  • 622ATM
  • AES/EBU
  • Digital Video, RS-422
  • Gigabit Ethernet
  • NTSC/PAL Component or Composite Video
  • Premise Horizontal Cable
  • CCTV UTP
  • PTZ
  • Pan/Tilt/Zoom Non-Plenum (NEC CM and CEC CM FT1) Category 5e u 24 AWG 1000 305 21.0 9.5 Solid 1640 500 34.4 15.7 Bare Copper 3000 915 63.0 28.6 Cond. u 24 AWG 1000 305 23.0 10.4 Solid Bare Copper Cond. Non-Plenum (NEC CMR and CEC CMR FT4) Category 5e u 24 AWG 1000 305 22.0 10.0 Solid 3000 915 63.0 28.6 Bare Copper Cond. u 24 AWG 1000 305 24.0 10.9 Solid Bare Copper Cond. Category 6 u 23 AWG 1000 305 30.0 13.6 Solid Bare Copper Cond. UTP = Unshielded Twisted Pair Refer to www.belden.com for jacket colors and put-ups. mFt. Standard Lengths mmInch kg Standard Unit Weight Insulation Nominal OD Nominal OD Inch mm Lbs. Part No. Component Descriptions Insulation Material Color Code Chart Pair No. Color Combinations

1 White/Blue Stripe & Blue

2 White/Orange Stripe & Orange

3 White/Green Stripe & Green

4 White/Brown Stripe & Brown

NEW GENERATION ® CABLES 20.41 Security UTP Cable CCTV Fixed and PTZ Applications Plenum-Rated 20 • New Generation Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com Plenum-Rated CMP FT6 Rated Product Description Solid bare copper conductors, unshielded twisted pairs, FEP Teflon® insulation, Flamarrest® jacket with rip cord. Sequential footagemarking every two feet. Specifications Conductor Solid Bare Copper Shield Unshielded Jacket Flamarrest Approvals NEC CMP CEC CMP FT6 NEC Articles 800 Nominal Impedance 100Ω Temperature Rating 75°C Applications:

  • 100BaseTX
  • 100BaseVG ANYLAN
  • 155ATM
  • 622ATM
  • AES/EBU
  • Digital Video, RS-422
  • Gigabit Ethernet
  • NTSC/PAL Component or Composite Video
  • Premise Horizontal Cable
  • CCTV UTP
  • Pan/Tilt/Zoom (PTZ) Plenum-Rated (NEC CMP and CEC CMP FT6) Category 5e u 24 AWG 1000 305 24.0 10.9 Solid 3000 915 69.0 31.3 Bare Copper Cond. u 24 AWG 1000 305 23.0 10.4 Solid Bare Copper Cond. Category 6 u 23 AWG 1000 305 29.0 13.2 Solid Bare Copper Cond. UTP = Unshielded Twisted Pair Refer to www.belden.com for jacket colors and put-ups. mFt. Standard Lengths mmInch kg Standard Unit Weight Insulation Nominal OD Nominal OD Inch mm Lbs. Part No. Component Descriptions Insulation Material Teflon is a DuPont trademark. Color Code Chart Pair No. Color Combinations