542117 FESTO

Document overview

  • PDF pages: 2

Technical content

Page 1

Measured-value transducer DADE-MVC-010

Part number: 542117

PDF page 1 diagram

Data sheet

Feature Value
Diagnostic function Indication via LED
Mounting position Any
Short-circuit protection yes
Reverse polarity protection for PLC plug S1
Repetition accuracy Min. ±0.1 mm
Analog output 0 - 10 V as per EN 61131-2
Power supply requirement PELV
Debounce time at inputs 3 ms
Nominal operating voltage DC 24 V
Power failure buffering of logic voltage 10 ms
Residual ripple 4 Vss
Current consumption at nominal operating voltage 20 mA ... 30 mA
Permissible voltage fluctuations +/- 25 %
Certification RCM compliance mark
KC characters KC EMC
CE marking (see declaration of conformity) As per EU EMC directive As per EU RoHS directive
Corrosion resistance class (CRC) 1 - Low corrosion stress
Storage temperature -20 °C ... 70 °C
Relative air humidity 95 % Non-condensing
Degree of protection IP65 IP67
Ambient temperature 0 °C ... 55 °C
Product weight 128 g
Linearity error FS 0.2 %
Characteristic curve outputs as per EN 61131-2
Input characteristics as per EN 61131-2
Input switching logic PNP (positive switching)
Switching logic at outputs PNP (positive switching)
Electrical connection, displacement encoder M12 Socket 8-pin
Electrical connection PLC M12 Plug 8-pin
Type of mounting With through-hole

4/20/22 - Subject to change - Festo SE & Co. KG

1/2

Page 2

Feature Value
Housing material PBT-reinforced

4/20/22 - Subject to change - Festo SE & Co. KG

2/2