461 LITTELFUSE

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Features

  • Surface mount surge resistant Slo-Blo® fuse
  • Meet UL 60950 3rd Edition power cross requirements standard alone
  • Designed to allow compliance with Telcordia GR-1089-CORE and TIA- 968-A (formerly FCC Part 68) Surge Specifications
  • Provide coordinated protection with Littelfuse SIDACtor ® Transient Voltage Suppressor (TVS)or a Greentube TM Gas Plasma Arrestor, without series resistors
  • Designed to serve the requirements of a wide range of telecommunication and networking equipment
  • 2A rating has improved temperature rise performance under 2.2A surge current testing when compared with 1 .25A rating
  • Product is Halogen Free and RoHS compliant and compatible with lead- free solder and higher temperature profiles when ordered with Standard Silver Plated Brass Caps
  • Standard product is RoHS Compliant and compatible with lead-free solders and higher temperature profiles RoHS AGENCY AGENCY FILE NUMBER AMPERE RANGE E10480 .5A - 2A 29862 .5A - 2A % of Ampere Rating Opening Time 100% 4 hours, Minimum 250% 1 sec., Min.; 120 secs., Max. The Littelfuse 461 Series TeleLink® Surface Mount, Surge Resistant Fuse, offers over-current protection for a wide range of telecom applications without requiring a series resistor. When used in conjunction with a Littelfuse SIDACtor® Transient Voltage Suppressor (TVS) or a GreentubeTM Gas Plasma Arrestor, this combination provides a compliant solution for standards and recommendations such as GR-1089–Core, TIA-968-A, UL/ EN/IEC 60950, and ITU K.20 and K.21 . The coordination requirement contained in GR-1089–Core, and ITU K.20/21 may require a series of impedance devices.

Applications

  • T1/E1/J1 and HDSL2/4
  • SLIC interface portion of Fiber to the Curb (FTTC) and Fiber to the Premises (FTTP)
  • Non-Fiber SLIC interface for Central Office (CO) locations and Remote Terminals (RT)
  • xDSL applications such as ADSL, ADSL2+, VDSL, and VDSL2+
  • Ethernet 10/100/1000BaseT
  • POTS applications such as modems, answering machines, telephones, fax machines, and security systems
  • ISDN “U” interface
  • Baystation T1/E1/J1, T3 (DS3) trunk cards Telecom Nano2® Fuse Temperature Reading 04611 .25 < 82°C (180°F) Maximum T emperature Rise Higher Currents and PCB layout designs can affect this parameter. Readings are measured at rated current after temperature stabilizes. Specifications are subject to change without notice. Application testing is strongly recommended. Additional Information Datasheet SamplesResources

© 2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 05/18/15 Surface Mount Fuses Surge Resistant > 461 Series TeleLink® Fuse Electrical Specifications by Item Ampere Rating (A) Amp Code Max Voltage Rating (V) Interrupting Rating Nominal Cold Resistance (Ohms) Nominal Melting I2t (A2sec) Agency Approvals 0.500 .500 600 50A @ 250 VAC

60 A @600 VAC

100 A @80 VDC

0.560 0.8401 x x 1 .25 1 .25 600 .1040 16.51 x x 2.00 002. 600 .0450 1 7. 51 x x

  • Typical inductance <40nH up to 500 MHz.
  • Resistance changes 0.5% for every °C.
  • Resistance is measured at 10% rated current. GR 1089 Inter-building requirements GR 1089 1st level lighting surge inter-building (Equipment under test can not be damaged and must continue to operate properly) Surge Minimum Peak Voltage (V) Minimum Peak Current (A) Max. Rise/Min. Decay (µs) Repetitions Each Polarity Fuse Choices 1 600 100 10/1000 25 1 .25, 2.0 2 1000 100 10/360 25 1 .25, 2.0 3 1000 100 10/1000 25 1 .25, 2.0 4 2500 500 2/10 10 1 .25, 2.0 5 1000 25 10/360 5 0.5, 1 .25, 2.0 GR 1089 2nd level lightning surge telecom port (Equipment under test shall not become a fire or electrical safety hazard) Surge Minimum Peak Voltage (V) Minimum Peak Current (A) Max. Rise/Min. Decay (µs) Repe- titions Each Polarity Fuse Choices 1 5000 500 2/10 1 0.5, 1 .25, 2.0 Alter- native 5000 500/8=625 8/10 1 0.5, 1 .25, 2.0 If sufficient series resistance is used, then the 0.5 fuse may be used in test conditions 1-4. The 0.5 fuse will open during these test conditions. The 1 .25 & 2.0 will not open thus providing operational compliance. Average Time Current Curves 10001001010.1 0.001 0.01 0.1 100 CURRENT IN AMPERES TIME IN SECONDS 1.25A .500A T emperature Re-rating Curve Note: 1 . Re-rating depicted in this curve is in addition to the standard re-rating of 25% for continuous operation.

© 2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 05/18/15 Surface Mount Fuses Surge Resistant > 461 Series TeleLink® Fuse GR 1089 AC power fault 2nd level (fuse can open but must open in a safe and controlled manner) Test Vrms Short Circuit Current (A) Hits Duration Primary Protector Fuse Choices 1 50 0.33 1 15 min. removed 1 .25, 2.0 2 100 0.17 1 15 min. removed 1 .25, 2.0 3 200,400, 600 1 60 1 sec. removed 1 .25, 2.0 4 1000 1 60 1 sec. operative 1 .25, 2.0 5 Diagram Diagram 60 5 secs. removed 1 .25, 2.0 6 600 0.5 1 30 secs. removed 1 .25, 2.0 7 440 2.2 5 2 secs. removed 1 .25, 2.0 8 600 3 1 1 .1 secs. removed 1 .25, 2.0 9 1000 5 1 0.4 sec. in place 1 .25, 2.0 Test Circuit Vrms Short Circuit Current (A) Duration Fuse 1 120,277 25 15 min. 0.5, 1 .25, 2.0 2 600 60 5 secs. 0.5, 1 .25, 2.0 3 600 7 5 secs. 0.5, 1 .25, 2.0 5 Diagram Diagram 15 min. 0.5, 1 .25, 2.0 Fuse must open before wiring simulator fuse (MDL 2.0). Surge Voltage (V) Waveform (µs) Current (A) Repetitions Recommended Fuse Metallic A 800 10×560 100 1 ea. polarity 1 .25 Longitudinal A 1500 10×160 200 1 ea. polarity 1 .25 Metallic B 1000 9×720 25 1 ea. polarity 1 .25 Longitudinal B 1500 9×720 37 .5 1 ea. polarity 1 .25 TIA –968-A (formerly FCC Part 68) Surge Waveforms (fuse can not open during type B events) UL 60950 requirements UL60950 (EN 60950) (formerly UL 1950) Power Cross (L = longitudinal, M = metallic) Test Number Voltage (V) Current (A) Time Fuse Choices L2 600 7 5 secs. 0.5, 1 .25, 2.0 L5 120 25 30 min. 0.5, 1 .25, 2.0 M2 600 7 5 secs. 0.5, 1 .25, 2.0 Selection of test number depends on current limiting F fire enclosure/spacing of end product

  • 26 AWG line cord removes L1/M1 test requirement
  • L5 conducted only if product does not pass section 6.1.2
  • L2,M2,L3,M3,L4,M4 conducted if not in a fire enclosure Fuse must open before the wiring simulator fuse (MDL 2.0). UL60950 (EN 60950) (formerly UL 1950) Impulse T est and Steady-State Electric Strength T est Test Voltage (V) Current (A) Waveform Repetitions Fuse Choices Impulse Steady-State For handheld units 1500 60Hz 0.5, 1 .25, 2.0 Non handheld 1000 60Hz 0.5, 1 .25, 2.0 LF 1.25A T 3.12 (.123") 3.12 (.123") 10.10 (.397") 3.25 (.128") 3.43 (.135") 12.6 (.496") 6.10 (.240") Recommended Pad Layout1.70 typ (.067") Dimensions GR 1089 AC power fault 1st level inter-building (fuse not allowed to open)

© 2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 05/18/15 Surface Mount Fuses Surge Resistant > 461 Series TeleLink® Fuse Materials Body: Ceramic T erminations: Silver-plated Caps Product Marking Brand Logo, Ampere Rating, T Operating T emperature -55°C to 125°C Moisture Sensitivity Level Level 1, J-STD-020C Solderability IEC-60127-4 (215°C immersion, 3 seconds) Resistance to Dissolution of Metallization IPC / EIA J-STD-002-Test D 260°C for 120 seconds Thermal Shock MIL -STD-202, Method 107 , Test Condition B, -55°C to +125°C, 30 minutes @ each extreme Mechanical Shock MIL -STD-202, Method 213, Test Condition A - Half Sine, 50 G's, 11 msecs. duration High Frequency Vibration MIL -STD-202, Method 204, Test Condition D Moisture Resistance MIL -STD-202, Method 106, 50 cycles T erminal Strength Board deflection per EIA / IS-722, 1mm deflection for 1 minute T erminal Attachment MIL -STD-202, Method 211, Test Condition A, 5 lbs applied to end caps Product Characteristics Reflow Condition Pb – free assembly Pre Heat - Temperature Min (Ts(min)) 150°C - Temperature Max (Ts(max)) 200°C - Time (Min to Max) (ts) 60 – 120 seconds Average Ramp-up Rate (Liquidus Temp (TL) to peak) 5°C/second max. TS(max) to TL - Ramp-up Rate 5°C/second max. Reflow - Temperature (TL) (Liquidus) 217°C - Temperature (tL) 60 – 90 seconds Peak Temperature (TP) 260+0/–5 °C Time within 5°C of actual peak Temperature (t p) 20 – 40 seconds Ramp-down Rate 6°C/second max. Time 25°C to peak Temperature (TP) 8 minutes max. Do not exceed 260°C Soldering Parameters Packaging Part Numbering System Packaging Option Packaging Specification Quantity Quantity & Packaging Code 24mm Tape and Reel EIA RS-481-2 (IEC 286, part 3) 2500 ER 0461 1.25 E R SERIES AMP Code* QUANTITY Code PACKAGING Code Refer to Electrical Characteristics table E = 2500 pcs R = Tape and Reel *Example: 2 amp product is 0461002.ER (1 .25 amp product shown above) Time Temperature TP TL TS(max) TS(min) tP tL tS time to peak temperature (t 25ºC to peak) Ramp-down Ramp-up Preheat Critical Zone TL to TP