4441FE BELDEN
Document overview
- PDF pages: 2
Technical content
Page 1

Product: 4441FE
Security & Sound, 2 Pairs 20 AWG BC, LSZH, Shielded, Eca
Product Description
Security & Commercial Audio Cable, 2-20 AWG stranded bare copper pairs with polypropylene insulation, Beldfoil® shield, LSZH jacket with ripcord, CPR Eca
Technical Specifications
Product Overview
Suitable Applications:
Commercial applications
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Pairs | |
|---|---|---|---|---|---|
| 20 | 7x28 | BC - Bare Copper | 0.96 mm | 2 | |
| Conductor Count: 4 | |||||
| Total Number of Pairs: 2 | |||||
Insulation
| Type | Material | Nominal Diameter | Diameter +/- Tolerance | Nominal Wall Thickness |
|---|---|---|---|---|
| Insulation | PP - Polypropylene | 1.27 mm | 0.05 mm | 0.2 mm |
Color Chart
Number Color
Pair 1 Black & Red
Pair 2 Black & White
Outer Shield
| Type | Material | Material Trade Name | Coverage [%] | Thickness of Foil | Drainwire Material | Drainwire AWG |
|---|---|---|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | 9 µm | TC - Tinned Copper | AWG24/7 |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness | Ripcord | |
|---|---|---|---|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 5.7 mm | 0.4 mm | Yes | |
| Table Notes: Ripcord provided under sheath | ||||
Construction and Dimensions
Cabling
Description
2 pairs twisted
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Outer Shield DCR |
|---|---|
| 34 Ohm/km | 34 Ohm/km |
Page 2
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
| 85 pF/m | 150 pF/m |
Current
Max. Recommended Current [A]
3 A
Voltage
Voltage Rating [V]
300 V
Temperature Range
Installation Temperature Range:
-20°C To +70°C
Storage Temperature Range:
-30°C to +70°C
Operating Temperature Range:
-20°C To +70°C
Mechanical Characteristics
Max. Pull Tension:
130 N
Min. Bend Radius During Installation:
57 mm
Min Setting Radius:
28 mm
Standards
CPR Euroclass:
Eca
Applicable Environmental and Other Programs
Environmental Space:
Indoor - Euroclass Eca
Flammability, LS0H, Toxicity Testing
IEC Flammability:
IEC 60332-1-2
IEC 60754-1 - Halogen Amount:
Zero
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity:
2.5 µS/mm
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH:
4.3
IEC 61034-2 - Smoke Density Min. Transmittance:
60%
History
Revision Number: 0.27 Revision Date: 08-25-2023
Update and Revision:
© 2023 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.