4441FE BELDEN

Document overview

  • PDF pages: 2

Technical content

Page 1

PDF page 1 diagram

Product: 4441FE

Security & Sound, 2 Pairs 20 AWG BC, LSZH, Shielded, Eca

Product Description

Security & Commercial Audio Cable, 2-20 AWG stranded bare copper pairs with polypropylene insulation, Beldfoil® shield, LSZH jacket with ripcord, CPR Eca

Technical Specifications

Product Overview

Suitable Applications:

Commercial applications

Physical Characteristics (Overall)

Conductor

AWG Stranding Material Nominal Diameter No. of Pairs
20 7x28 BC - Bare Copper 0.96 mm 2
Conductor Count: 4
Total Number of Pairs: 2

Insulation

Type Material Nominal Diameter Diameter +/- Tolerance Nominal Wall Thickness
Insulation PP - Polypropylene 1.27 mm 0.05 mm 0.2 mm

Color Chart

Number Color

Pair 1 Black & Red

Pair 2 Black & White

Outer Shield

Type Material Material Trade Name Coverage [%] Thickness of Foil Drainwire Material Drainwire AWG
Tape Bi-Laminate (Alum+Poly) Beldfoil® 100% 9 µm TC - Tinned Copper AWG24/7

Outer Jacket

Material Nominal Diameter Nominal Wall Thickness Ripcord
LSZH - Low Smoke Zero Halogen (Flame Retardant) 5.7 mm 0.4 mm Yes
Table Notes: Ripcord provided under sheath

Construction and Dimensions

Cabling

Description

2 pairs twisted

Electrical Characteristics

Conductor DCR

Nominal Conductor DCR Nominal Outer Shield DCR
34 Ohm/km 34 Ohm/km

Page 2

Capacitance

Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Other Conductor to Shield
85 pF/m 150 pF/m

Current

Max. Recommended Current [A]

3 A

Voltage

Voltage Rating [V]

300 V

Temperature Range

Installation Temperature Range:

-20°C To +70°C

Storage Temperature Range:

-30°C to +70°C

Operating Temperature Range:

-20°C To +70°C

Mechanical Characteristics

Max. Pull Tension:

130 N

Min. Bend Radius During Installation:

57 mm

Min Setting Radius:

28 mm

Standards

CPR Euroclass:

Eca

Applicable Environmental and Other Programs

Environmental Space:

Indoor - Euroclass Eca

Flammability, LS0H, Toxicity Testing

IEC Flammability:

IEC 60332-1-2

IEC 60754-1 - Halogen Amount:

Zero

IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity:

2.5 µS/mm

IEC 60754-2 - Halogen Acid Gas Amount - Min. pH:

4.3

IEC 61034-2 - Smoke Density Min. Transmittance:

60%

History

Revision Number: 0.27 Revision Date: 08-25-2023

Update and Revision:

© 2023 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,

negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product

Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.