44049 ETC1
Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 1
Technical content
- to be noted : 2 x 24 V non safety transformer approved, conform to EN 61558-2-6 (Isolating transformer). PRIMARY VOLTAGE Protection Reference Secondary voltage V Secondary Current m A No-load voltage V Ambient Temperature Rating VA 44049 6 167 8,6 T 70 B 1 44050 9 111 12,9 T 70 B 1 44051 12 83 17,2 T 70 B 1 44052 15 67 21,6 T 70 B 1 44053 18 56 25,9 T 70 B 1 44054 24 42 37,9 T 70 B 1 44055 2 x 6 2 x 83 2 x 8,6 T 70 B 1 44056 2 x 9 2 x 56 2 x 12,9 T 70 B 1 44057 2 x 12 2 x 42 2 x 19 T 70 B 1 44058 2 x 15 2 x 33 2 x 23,6 T 70 B 1 44059 2 x 18 2 x 28 2 x 24,9 T 70 B 1 44060* 2 x 24 2 x 21 2 x 37,9 T 70 B 1 /g108Vacuum filling /g108Two compartments bobbins /g108Self-extinguishing plastics UL 94 VO /g108Degree of protection IP 00 /g10870 grams weight /g108Resin class B CEI 85 (20 000 h testing to CEI 126) /g108Inherently short-circuits proof transformer /g10830 V and 36 V models are VDE EN 61558-2-6 certified (production on request) /g108Insulation voltage 4 KV (6 KV MYRRA test) /g108100% tested production /g108Certification : CCA procedure on request n