Document Number: 93150 For technical ques tions, contact: ind-modules@vishay.com www.vishay.com Revision: 16-May-08 1 Fast Recovery Diodes (Stud Version), 40/70/85 A 40HFL, 70HFL, 85HFL Series Vishay High Power Products
FEATURES
- Short reverse recovery time Low stored charge Wide current range Excellent surge capabilities Stud cathode and stud anode versions Types up to 100 V RRM RoHS compliant TYPICAL APPLICATIONS DC power supplies I n v e r t e r s Converters Choppers Ultrasonic systems Freewheeling diodes PRODUCT SUMMARY IF(AV) 40/70/85 A DO-203AB (DO-5) RoHS COMPLIANT MAJOR RATINGS AND CHARACTERISTICS SYMBOL CHARACTERISTICS 40HFL 70HFL 85HFL UNITS IF(AV) 40 70 85 A Maximum TC 85 85 85 °C IFSM
50 Hz 400 700 1100
A
60 Hz 420 730 1151
50 Hz 800 2450 6050
60 Hz 730 2240 5523
I2√t 11 300 34 650 85 560 I 2√s VRRM Range 100 to 1000 V trr See Recovery Characteristics table ns TJ Range - 40 to 125 °C
www.vishay.com For technical questi ons, contact: ind-modules@vishay.com Document Number: 93150
2 Revision: 16-May-08
40HFL, 70HFL, 85HFL Series Vishay High Power Products Fast Recovery Diodes (Stud Version), 40/70/85 A ELECTRICAL SPECIFICATIONS Note (1) Types listed are cathode case, for anode case add “R” to code, i.e. 40HFLR20S02, 85HFLR100S05 etc. VOLTAGE RATINGS TYPE NUMBER (1) VRRM, MAXIMUM PEAK REPETITIVE REVERSE VOLTAGE TJ = - 40 TO 125 °C V VRSM, MAXIMUM PEAK NON-REPETITIVE REVERSE VOLTAGE TJ = 25 TO 125 °C V IFM, MAXIMUM PEAK REVERSE CURRENT AT RATED VRRM mA TJ = 25 °C T J = 125 °C 40HFL10S02, 40HFL10S05, 40HFL10S10 100 150 0.1 10 40HFL20S02, 40HFL20S05, 40HFL20S10 200 300 40HFL40S02, 40HFL40S05, 40HFL40S10 400 500 40HFL60S02, 40HFL60S05, 40HFL60S10 600 700 40HFL80S05, 40HFL80S10 800 900 40HFL100S05, 40HFL100S10 1000 1100 70HFL10S02, 70HFL10S05, 70HFL10S10 100 150 0.1 15 70HFL20S02, 70HFL20S05, 70HFL20S10 200 300 70HFL40S02, 70HFL40S05, 70HFL40S10 400 500 70HFL60S02, 70HFL60S05, 70HFL60S10 600 700 70HFL80S05, 70HFL80S10 800 900 70HFL100S05, 70HFL100S10 1000 1100 85HFL10S02, 85HFL10S05, 85HFL10S10 100 150 0.1 20 85HFL20S02, 85HFL20S05, 85HFL20S10 200 300 85HFL40S02, 85HFL40S05, 85HFL40S10 400 500 85HFL60S02, 85HFL60S05, 85HFL60S10 600 700 85HFL80S05, 85HFL80S10 800 900 85HFL100S05, 85HFL100S10 1000 1100
Document Number: 93150 For technical ques tions, contact: ind-modules@vishay.com www.vishay.com Revision: 16-May-08 3 40HFL, 70HFL, 85HFL Series Fast Recovery Diodes (Stud Version), 40/70/85 A Vishay High Power Products Note (1) I2t for time tx = I2√t √tx FORWARD CONDUCTION PARAMETER SYMBOL TEST CONDITIONS 40HFL 70HFL 85HFL UNITS Maximum average forward current at maximum case temperature IF(AV) 180° conduction, half sine wave 40 70 85 A 75 °C Maximum RMS forward current I F(RMS) 63 110 134 A Maximum peak repetitive forward current I FRM Sinusoidal half wave, 30° conduction 220 380 470 A Maximum peak, one-cycle non-repetitive forward current IFSM t = 10 ms Sinusoidal half wave, 100 % VRRM reapplied, initial TJ = TJ maximum 400 700 1100 A t = 8.3 ms 420 730 1151 t = 10 ms Sinusoidal half wave, no voltage reapplied, initial T J = TJ maximum 475 830 1308 t = 8.3 ms 500 870 1369 Maximum I2t for fusing I 2t t = 10 ms 100 % VRRM reapplied, initial TJ = TJ maximum 800 2450 6050 A2s t = 8.3 ms 730 2240 5523 t = 10 ms No voltage reapplied, initial TJ = TJ maximum 1130 3460 8556 t = 8.3 ms 1030 3160 7810 Maximum I2√t for fusing (1) I2√t t = 0.1 to 10 ms, no voltage reapplied 11 300 34 650 85 560 A 2√s Maximum value of threshold voltage V F(TO) TJ = 125 °C 1.081 1.085 1.128 V Maximum value of forward slope resistance r F 6.33 3.40 2.11 m Ω Maximum forward voltage drop V FM TJ = 25 °C, IFM = π x IF(AV) 1.95 1.85 1.75 V RECOVERY CHARACTERISTICS PARAMETER SYMBOL TEST CONDITIONS UNITS S02 S05 S10 S02 S05 S10 S02 S05 S10 Typical reverse recovery time trr TJ = 25 °C, IF = 1 A to VR = 30 V, - dIF/dt = 100 A/µs 70 180 350 60 150 290 50 120 270 nsTJ = 25 °C, - dIF/dt = 25 A/µs, IFM = π x rated IF(AV) 200 500 1000 200 500 1000 200 500 1000 Typical reverse recovered charge Qrr TJ = 25 °C, IF = 1 A to VR = 30 V, - dIF/dt = 100 A/µs 160 750 3100 90 500 1600 70 340 1350 nCTJ = 25 °C, - dIF/dt = 25 A/µs, IFM = π x rated IF(AV) 240 1300 6000 240 1300 6000 240 1300 6000
www.vishay.com For technical questi ons, contact: ind-modules@vishay.com Document Number: 93150
4 Revision: 16-May-08
40HFL, 70HFL, 85HFL Series Vishay High Power Products Fast Recovery Diodes (Stud Version), 40/70/85 A Fig. 1 - Reverse Recovery Time Test Waveform Fig. 2 - Current Rating Nomogram (Sinusoidal Waveforms), 40HFL Series THERMAL AND MECHANICAL SPECIFICATIONS PARAMETER SYMBOL TEST CONDITIONS 40HFL 70HFL 85HFL UNITS Junction operating temperature range T J - 40 to 125 Storage temperature range T Stg - 40 to 150 Maximum thermal resistance, junction to case RthJC DC operation 0.60 0.36 0.30 K/W Maximum thermal resistance, case to heatsink RthCS Mounting surface, smooth, flat and greased 0.25 Allowable mounting torque Not lubricated threads 3.4 + 0 - 10 % (30) N · m (lbf · in) Lubricated threads 2.3 + 0 - 10 % (20) Approximate weight 25 g 0.88 oz. Case style JEDEC DO-203AB (DO-5)
Document Number: 93150 For technical ques tions, contact: ind-modules@vishay.com www.vishay.com Revision: 16-May-08 5 40HFL, 70HFL, 85HFL Series Fast Recovery Diodes (Stud Version), 40/70/85 A Vishay High Power Products Fig. 3 - Current Rating Nomogram (Rectangular Waveforms), 40HFL Series Fig. 4 - Current Rating Nomogram (Sinusoidal Waveforms), 70HFL Series Fig. 5 - Current Rating Nomogram (Rectangular Waveforms), 70HFL Series 70HFL
www.vishay.com For technical questi ons, contact: ind-modules@vishay.com Document Number: 93150
6 Revision: 16-May-08
40HFL, 70HFL, 85HFL Series Vishay High Power Products Fast Recovery Diodes (Stud Version), 40/70/85 A Fig. 6 - Current Rating Nomogram (Sinusoidal Waveforms), 85HFL Series Fig. 7 - Current Rating Nomogram (Rectangular Waveforms), 85HFL Series Fig. 8 - Maximum High Level Forward Power Loss vs. Average Forward Current, 40HFL Series Fig. 9 - Maximum High Level Forward Power Loss vs. Average Forward Current, 70HFL Series 85HFL 85HFL
Document Number: 93150 For technical ques tions, contact: ind-modules@vishay.com www.vishay.com Revision: 16-May-08 7 40HFL, 70HFL, 85HFL Series Fast Recovery Diodes (Stud Version), 40/70/85 A Vishay High Power Products Fig. 10 - Maximum High Level Forward Power Loss vs. Average Forward Current, 85HFL Series Fig. 11 - Maximum Forward Voltage vs. Forward Current, 40HFL Series Fig. 12 - Maximum Forward Voltage vs. Forward Current, 70HFL Series Fig. 13 - Maximum Forward Voltage vs. Forward Current, 85HFL Series Fig. 14 - Average Forward Current vs. Maximum Allowable Case Temperature, 40HFL Series Fig. 15 - Average Forward Current vs. Maximum Allowable Case Temperature, 70HFL Series
www.vishay.com For technical questi ons, contact: ind-modules@vishay.com Document Number: 93150
8 Revision: 16-May-08
40HFL, 70HFL, 85HFL Series Vishay High Power Products Fast Recovery Diodes (Stud Version), 40/70/85 A Fig. 16 - Average Forward Current vs. Maximum Allowable Case Temperature, 85HFL Series Fig. 17 - Maximum Non-Repetitive Surge Current vs. Number of Current Pulses, All Series Fig. 18 - Maximum Transient Thermal Impedance, Junction to Case vs. Pulse Duration, All Series Fig. 19 - Typical Reverse Recovery Time vs. Rate of Fall of Forward Current, 40HFL...S02 Series Fig. 20 - Typical Recovered Charge vs. Rate of Fall of Forward Current, 40HFL...S02 Series
Document Number: 93150 For technical ques tions, contact: ind-modules@vishay.com www.vishay.com Revision: 16-May-08 9 40HFL, 70HFL, 85HFL Series Fast Recovery Diodes (Stud Version), 40/70/85 A Vishay High Power Products Fig. 21 - Typical Reverse Recovery Time vs. Rate of Fall of Forward Current, 40HFL...S05 Series Fig. 22 - Typical Recovered Charge vs. Rate of Fall of Forward Current, 40HFL...S05 Series Fig. 23 - Typical Reverse Recovery Time vs. Rate of Fall of Forward Current, 40HFL...S10 Series Fig. 24 - Typical Recovered Charge vs. Rate of Fall of Forward Current, 40HFL...S10 Series Fig. 25 - Typical Reverse Recovery Time vs. Rate of Fall of Forward Current, 70HFL...S02 Series Fig. 26 - Typical Recovered Charge vs. Rate of Fall of Forward Current, 70HFL...S02 Series
www.vishay.com For technical questi ons, contact: ind-modules@vishay.com Document Number: 93150 40HFL, 70HFL, 85HFL Series Vishay High Power Products Fast Recovery Diodes (Stud Version), 40/70/85 A Fig. 27 - Typical Reverse Recovery Time vs. Rate of Fall of Forward Current, 70HFL...S05 Series Fig. 28 - Typical Recovered Charge vs. Rate of Fall of Forward Current, 70HFL...S05 Series Fig. 29 - Typical Reverse Recovery Time vs. Rate of Fall of Forward Current, 70HFL...S10 Series Fig. 30 - Typical Recovered Charge vs. Rate of Fall of Forward Current, 70HFL...S10 Series Fig. 31 - Typical Reverse Recovery Time vs. Rate of Fall of Forward Current, 85HFL...S02 Series Fig. 32 - Typical Recovered Charge vs. Rate of Fall of Forward Current, 85HFL...S02 Series
Document Number: 93150 For technical ques tions, contact: ind-modules@vishay.com www.vishay.com Revision: 16-May-08 11 40HFL, 70HFL, 85HFL Series Fast Recovery Diodes (Stud Version), 40/70/85 A Vishay High Power Products Fig. 33 - Typical Reverse Recovery Time vs. Rate of Fall of Forward Current, 85HFL...S05 Series Fig. 34 - Typical Recovered Charge vs. Rate of Fall of Forward Current, 85HFL...S05 Series Fig. 35 - Typical Reverse Recovery Time vs. Rate of Fall of Forward Current, 85HFL...S10 Series Fig. 36 - Typical Recovered Charge vs. Rate of Fall of Forward Current, 85HFL...S10 Series LINKS TO RELATED DOCUMENTS Dimensions http://www.vishay.com/doc?95312
Document Number: 91000 www.vishay.com Revision: 18-Jul-08 1 Disclaimer Legal Disclaimer Notice Vishay All product specifications and data are subject to change without notice. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. Vishay disclaims any and all li ability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permit ted by law. The product specifications do not expand or otherwise modify Vishay’s terms and conditions of purcha se, including but not limited to the warranty expressed therein, which apply to these products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. The products shown herein are not designed for use in medi cal, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners.