40HFR VISHAY

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(free datasheet download site)
  • PDF pages: 7

Technical content

Document Number: 93513 For technical ques tions, contact: ind-modules@vishay.com www.vishay.com Revision: 23-Jun-08 1 Standard Recovery Diodes, (Stud Version), 40 A 40HF(R) Series Vishay High Power Products

FEATURES

  • High surge current capability  Stud cathode and stud anode version  Leaded version available  Types up to 1600 V V RRM  RoHS compliant  Designed and qualified for multiple level TYPICAL APPLICATIONS  Battery charges  Converters  Power supplies  Machine tool controls  Welding ELECTRICAL SPECIFICATIONS PRODUCT SUMMARY IF(AV) 40 A DO-203AB (DO-5) RoHS COMPLIANT MAJOR RATINGS AND CHARACTERISTICS PARAMETER TEST CONDITIONS 40HF(R) UNITS

10 TO 120 140/160

IF(AV) 40 40 A TC 140 110 °C IF(RMS) 62 A IFSM

50 Hz 570

A

60 Hz 595

50 Hz 1600

60 Hz 1450

VRRM Range 100 to 1200 1400/1600 V TJ - 65 to 190 - 65 to 160 °C VOLTAGE RATINGS TYPE NUMBER VOLTAGE CODE VRRM, MAXIMUM REPETITIVE PEAK REVERSE VOLTAGE V VRSM, MAXIMUM NON-REPETITIVE PEAK REVERSE VOLTAGE V IRRM MAXIMUM AT TJ = TJ MAXIMUM mA 40HF(R) 10 100 200 20 200 300 40 400 500 60 600 700 80 800 900 100 1000 1100 120 1200 1300 140 1400 1500 4.5 160 1600 1700

www.vishay.com For technical questi ons, contact: ind-modules@vishay.com Document Number: 93513

2 Revision: 23-Jun-08

40HF(R) Series Vishay High Power Products Standard Recovery Diodes, (Stud Version), 40 A FORWARD CONDUCTION PARAMETER SYMBOL TEST CONDITIONS 40HF(R) UNITS Maximum average forward current at case temperature IF(AV) 180° conduction, half sine wave 40 40 A 140 110 °C Maximum RMS forward current I F(RMS) 62 A Maximum peak, one-cycle forward, non-repetitive surge current IFSM t = 10 ms No voltage reapplied Sinusoidal half wave, initial TJ = TJ maximum 570 A t = 8.3 ms 595 t = 10 ms 100 % VRRM reapplied 480 t = 8.3 ms 500 Maximum I2t for fusing I 2t t = 10 ms No voltage reapplied 1600 A2s t = 8.3 ms 1450 t = 10 ms 100 % VRRM reapplied 1150 t = 8.3 ms 1050 Maximum I2√t for fusing I 2√t t = 0.1 to 10 ms, no voltage reapplied 16 000 A 2√s Value of threshold voltage (up to 1200 V) VF(TO) TJ = TJ maximum 0.65 VValue of threshold voltage (for 1400 V/1600 V) VF(TO) 0.76 Value of forward slope resistance (up to 1200 V) rf TJ = TJ maximum 4.29 mΩ Value of forward slope resistance (for 1400 V/1600 V) rf 3.8 Maximum forward voltage drop V FM Ipk = 125 A, TJ = 25 °C, tp = 400 µs rectangular wave 1.30 1.50 V THERMAL AND MECHANICAL SPECIFICATIONS PARAMETER SYMBOL TEST CONDITIONS 40HF(R) UNITS Maximum junction operating and storage temperature range TJ, TStg - 65 to 190 - 65 to 160 °C Maximum thermal resistance, junction to case RthJC DC operation 0.95 K/W Maximum thermal resistance, case to heatsink RthCS Mounting surface, smooth, flat and greased 0.25 Allowable mounting torque Not lubricated threads 3.4 + 0 - 10 % (30) N · m (lbf · in) Lubricated threads 2.3 + 0 - 10 % (20) Approximate weight 17 g 0.6 oz. Case style See dimensions - link at the end of datasheet DO-203AB (DO-5)

Document Number: 93513 For technical ques tions, contact: ind-modules@vishay.com www.vishay.com Revision: 23-Jun-08 3 40HF(R) Series Standard Recovery Diodes, (Stud Version), 40 A Vishay High Power Products Note  The table above shows the increment of thermal resistance R thJC when devices operate at different conduction angles than DC Fig. 1 - Current Ratings Characteristics Fig. 2 - Current Ratings Characteristics Fig. 3 - Current Ratings Characteristics Fig. 4 - Current Ratings Characteristics ΔRthJC CONDUCTION CONDUCTION ANGLE SINUSOIDAL CONDUCTION RECT ANGULAR CONDUCTION TEST CONDITIONS UNITS 180° 0.14 0.10 TJ = TJ maximum K/W 120° 0.16 0.17 90° 0.21 0.22 60° 0.30 0.31 30° 0.50 0.50 Average Forward Current (A) Maximum Allowable Case Temperature (°C) 130 140 150 160 170 180 190 0 5 10 15 20 25 30 35 40 45 30° 60° 90° 120° 180° Conduction Angle 40HF(R) Series (100V to 1200V) Average Forward Current (A) Maximum Allowable Case Temperature (°C) 120 130 140 150 160 170 180 190 0 1 02 03 04 05 06 07 0 DC 30° 60° 90° 120° 180° Conduction Period 40HF(R) Series (100V to 1200V) Average Forward Current (A) Maximum Allowable Case Temperature (°C) 100 110 120 130 140 150 160 0 5 10 15 20 25 30 35 40 45 30° 60° 90° 120° 180° Conduction Angle 40HF(R) Series (1400V, 1600V) Average Forward Current (A) Maximum Allowable Case Temperature (°C) 100 110 120 130 140 150 160 0 1 02 03 04 05 06 07 0 DC 30° 60° 90° 120° 180° Conduction Period 40HF(R) Series (1400V, 1600V)

www.vishay.com For technical questi ons, contact: ind-modules@vishay.com Document Number: 93513

4 Revision: 23-Jun-08

40HF(R) Series Vishay High Power Products Standard Recovery Diodes, (Stud Version), 40 A Fig. 5 - Forward Power Loss Characteristics Fig. 6 - Forward Power Loss Characteristics Fig. 7 - Forward Power Loss Characteristics Average Forward Current (A) Maximum Average Forward Power Loss (W) Maximum Allowable Ambient Temperature (°C) 0 40 80 120 160 200

10 K/W

RthSA = 1 K/W - Delta R

1.5 K/W

2 K/W

3 K/W

5 K/W

7 K/W

180° 120° 90° 60° 30° 40HF(R) Series (100V to 1200V) Tj = 190°C Average Forward Current (A) Maximum Average Forward Power Loss (W) Maximum Allowable Ambient Temperature (°C) 0 40 80 120 160 200 RthSA = 1 K/W - Delta R 180° 120° 90° 60° 30° RMS Limit Conduction Period 40HF(R) Series (100V to 1200V) Tj = 190°C Average Forward Current (A) Maximum Average Forward Power Loss (W) Maximum Allowable Ambient Temperature (°C) 0 25 50 75 100 125 150 175 200 1.5 K/ W RthSA = 1 K/W - Delta R 0 1 02 03 04 0 RMS Limit Conduction Angle 180° 120° 90° 60° 30° 40HF(R) Series (1400V, 1600V) Tj = 160°C

Document Number: 93513 For technical ques tions, contact: ind-modules@vishay.com www.vishay.com Revision: 23-Jun-08 5 40HF(R) Series Standard Recovery Diodes, (Stud Version), 40 A Vishay High Power Products Fig. 8 - Forward Power Loss Characteristics Fig. 9 - Maximum Non-Repetitive Surge Current Fig. 10 - Maximum Non-Repetitive Surge Current Fig. 11 - Forward Voltage Drop Characteristics (Up To 1200 V) Fig. 12 - Forward Voltage Drop Characteristics (For 1400 V/1600 V) Average Forward Current (A) Maximum Average Forward Power Loss (W) Maximum Allowable Ambient Temperature (°C) 04 0 8 0 1 2 0 1 6 0 RthSA = 1 K/W - Delta R 180° 120° 90° 60° 30° RMS Limit Conduction Period 40HF(R) Series (1400V, 1600V) Tj = 160°C Number Of Equal Amplitude Half Cycle Current Pulses (N) Peak Half Sine Wave Forward Current (A) 100 150 200 250 300 350 400 450 500 550 11 0 1 0 0 40HF(R) Series Initial Tj = Tj Max. @ 60 Hz 0.0083 s @ 50 Hz 0.0100 s At Any Rated Load Condition And With Rated Vrrm Applied Following Surge. Pulse Train Duration (s) Peak Half Sine Wave Forward Current (A) 100 150 200 250 300 350 400 450 500 550 600 0.01 0.1 1 Maximum Non Repetitive Surge Current 40HF(R) Series Initial Tj = Tj Max. No Voltage Reapplied Rated Vrrm Reapplied Versus Pulse Train Duration. Instantaneous Forward Voltage (V) Instantaneous Forward Current (A) 100 1000 40HF(R) Series up to 1200V Tj = 25°C Tj = Tj Max. Instantaneous Forward Voltage (V) Instantaneous Forward Current (A) 100 1000 00 . 511 . 522 . 533 . 54 Tj = 25°C Tj = Tj Max 40HF (R) Series

www.vishay.com For technical questi ons, contact: ind-modules@vishay.com Document Number: 93513

6 Revision: 23-Jun-08

40HF(R) Series Vishay High Power Products Standard Recovery Diodes, (Stud Version), 40 A Fig. 13 - Thermal Impedance ZthJC Characteristics ORDERING INFORMATION TABLE Square Wave Pulse Duration (s) Transient Impedance Z thJC (K/W) 0.01 0.1 0.0001 0.001 0.01 0.1 1 10 Steady State Value (DC Operation) 40HF(R) .. Series - 40 = Standard device 41 = Not isolated lead 42 = Isolated lead with silicone sleeve (red = Reverse polarity) (blue = Normal polarity) - HF = Standard diode - None = Stud normal polarity (cathode to stud) R = Stud reverse polarity (anode to stud) - Voltage code x 10 = V RRM (see Voltage Ratings table) - None = Stud base DO-203AB (DO-5) 1/4" 28UNF-2 A M = Stud base DO-203AB (DO-5) M6 x 1 Device code 513 24

40 HF R 160 M

LINKS TO RELATED DOCUMENTS Dimensions http://www.vishay.com/doc?95344

Document Number: 91000 www.vishay.com Revision: 18-Jul-08 1 Disclaimer Legal Disclaimer Notice Vishay All product specifications and data are subject to change without notice. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. Vishay disclaims any and all li ability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permit ted by law. The product specifications do not expand or otherwise modify Vishay’s terms and conditions of purcha se, including but not limited to the warranty expressed therein, which apply to these products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. The products shown herein are not designed for use in medi cal, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners.