3R-8-SSS YAGEO
Document overview
- PDF pages: 6
Technical content
Page 1


Page 2

Gas Discharge Tube (GDT) Data Sheet
Features
■ Provide ultra-fast response to surge voltage from slow-rising surge of 100V/s to rapid-rising surge of 1KV/μs ■ Stable breakdown voltage ■ High insulation resistance ■ Low capacitance (≤2pF) ■ High holdover voltage ■ Large absorbing transient current capability ■ Micro-Gap Design ■ Size: 8.0mm\*10.0mm ■ Storage and operating temperature: -40℃ ~ +85℃ ■ Meets MSL level 1, per J-STD-020 ■ Safety certification: UL
Applications
■ Repeaters, Modems ■ Telephone Interface, Line cards ■ Data communication equipment ■ Line test equipment
Part Number Code

Electrode Numbers 3R: 3 Electrodes
Dimensions


SSS
Internal Control Code
Dimensions 8: 8.0mm×10.0mm
| M Type | Symbol | Dimension (mm) | |
| Spec. | Tolerance | ||
| D | 8.0 | +0.2, -0.8 | |
| D1 | 7.9 | ±0.2 | |
| T | 10.0 | ±0.5 | |
| B | 0.5 | ±0.1 | |
| B1 | 1.5 | ±0.2 | |
Electrical Characteristics
Page 3

| Part Number | Type ① | DC Spark-over Voltage | Maximum Impulse Spark-over Voltage | Nominal Impulse Discharge Current | Alternating Discharge Current | Impulse Life | Minimum Insulation Resistance | Maximum Capacitan ce | Device Marking Code | |
|---|---|---|---|---|---|---|---|---|---|---|
| 100V/s | 1000V/μs | 8/20μs 10times | 50Hz,1sec | 10/1000μs 100A | Test Voltage | (GΩ) | 1MHz | |||
| (V) | (V) | (KA) | (A) | (times) | DC(V) | (pF) | ||||
| 3RM075M-8 | SSS | 75±20% | 700 | 10 | 10 | 300 | 25 | 1.0 | 2.0 | None |
| 3RM090M-8 | SSS | 90±20% | 700 | 10 | 10 | 300 | 50 | 1.0 | 2.0 | None |
| 3RM150M-8 | SSS | 150±20% | 700 | 10 | 10 | 300 | 100 | 1.0 | 2.0 | None |
| 3RM200M-8 | SSS | 200±20% | 700 | 10 | 10 | 300 | 100 | 1.0 | 2.0 | None |
| 3RM230M-8 | SSS | 230±20% | 800 | 10 | 10 | 300 | 100 | 1.0 | 2.0 | None |
| 3RM350M-8 | SSS | 350±20% | 900 | 10 | 10 | 300 | 100 | 1.0 | 2.0 | None |
| 3RM400M-8 | SSS | 400±20% | 1000 | 10 | 10 | 300 | 100 | 1.0 | 2.0 | None |
| 3RM470M-8 | SSS | 470±20% | 1100 | 10 | 10 | 300 | 250 | 1.0 | 2.0 | None |
| 3RM600M-8 | SSS | 600±20% | 1300 | 10 | 10 | 300 | 250 | 1.0 | 2.0 | None |
| 3RP075M-8 | SSS | 75±20% | 700 | 20 | 20 | 300 | 25 | 1.0 | 2.0 | None |
| 3RP090M-8 | SSS | 90±20% | 700 | 20 | 20 | 300 | 50 | 1.0 | 2.0 | None |
| 3RP150M-8 | SSS | 150±20% | 700 | 20 | 20 | 300 | 100 | 1.0 | 2.0 | None |
| 3RP200M-8 | SSS | 200±20% | 700 | 20 | 20 | 300 | 100 | 1.0 | 2.0 | None |
| 3RP230M-8 | SSS | 230±20% | 800 | 20 | 20 | 300 | 100 | 1.0 | 2.0 | None |
| 3RP350M-8 | SSS | 350±20% | 900 | 20 | 20 | 300 | 100 | 1.0 | 2.0 | None |
| 3RP400M-8 | SSS | 400±20% | 1000 | 20 | 20 | 300 | 100 | 1.0 | 2.0 | None |
| 3RP470M-8 | SSS | 470±20% | 1100 | 20 | 20 | 300 | 250 | 1.0 | 2.0 | None |
| 3RP600M-8 | SSS | 600±20% | 1300 | 20 | 20 | 300 | 250 | 1.0 | 2.0 | None |
Notes:① Specific code by request.
Electrical Ratings
| Items | Test Condition/Description | Requirement |
|---|---|---|
| DC Spark-over Voltage | The voltage is measured with voltage ramp dv/dt=100V/s. Test is between each side electrode and center electrode. | To meet the specified value |
| Maximum Impulse Spark-over Voltage | The maximum impulse spark-over voltage is measured with voltage ramp dv/dt=1000V/μs. Test is between each side electrode and center electrode. |
Page 4

| Impulse Discharge Current | Maximum surge current that can be applied through center electrode with 8/20μs waveform, for 10 times with 3min interval time, which will be equally divided between each side electrode to center electrode. | |
|---|---|---|
| Alternating Discharge Current | Rated RMS value of AC current at 50Hz, 1 sec. for 10 times with interval time 3 min. Test is between each side electrode and center electrode. | |
| Insulation Resistance | The resistance of gas tube shall be measured between each side electrodes and center electrode. | |
| Capacitance | The capacitance of gas tube shall be measured between each side electrodes and center electrode.Test frequency: 1MHz |
Recommended Soldering Conditions

Page 5

Recommended Conditions


| Profile Feature | Pb-Free Assembly |
| Average ramp-up rate (T to T P) L | 3℃/second max. |
| Preheat -Temperature Min (T ) S min -Temperature Max (T ) S max -Time (min to max) (ts) | 150℃ 200℃ 60-180 seconds |
| T to T S max L -Ramp-up Rate | 3℃/second max. |
| Time maintained above: -Temperature (T ) L -Time (t ) L | 217℃ 60-150 seconds |
| Peak Temperature (T ) P | 260℃ |
| Time within 5℃of actual Peak Temperature (t ) P | 20-40 seconds |
| Ramp-down Rate | 6℃/second max. |
| Time 25℃to Peak Temperature | 8 minutes max. |
Packaging SMD Packing (Tape & Reel)
| Tape | Symbol | Dimension (mm) | |
| Spec. | Tolerance | ||
| W | 16.00 | ±0.20 | |
| P0 | 4.00 | ±0.10 | |
| P | 16.00 | ±0.10 | |
| P2 | 2.00 | ±0.10 | |
| D0 | 1.55 | ±0.10 | |
| E | 1.75 | ±0.10 | |
| F | 7.50 | ±0.10 | |
| A0 | 10.30 | ±0.10 | |
| K0 | 8.40 | ±0.10 | |
| B0 | 8.40 | ±0.10 | |
| T | 0.50 | ±0.05 | |
| Reel | D | 330.00 | ±2.00 |
| d | 13.00 | ±0.50 | |
| L | 20.00 | ±2.00 | |
| t | 2.00 | ±0.20 | |
| Quantity: 300pcs | |||
Page 6
Product specification
Circuit Protection Components
LEGAL DISCLAIMER
YAGEO, its distributors and agents (collectively, “YAGEO”), hereby disclaims any and all liabilities for any errors, inaccuracies or incompleteness contained in any product related information, including but not limited to product specifications, datasheets, pictures and/or graphics. YAGEO may make changes, modifications and/or improvements to product related information at any time and without notice.
YAGEO makes no representation, warranty, and/or guarantee about the fitness of its products for any particular purpose or the continuing production of any of its products. To the maximum exten t permitted by law, YAGEO disclaims (i) any and all liability arising out of the application or use of any YAGEO product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for a particular purpose, non -infringement and merchantability.
YAGEO products are designed for general purpose applications under normal operation and usage conditions. Please contact YAGEO for the applications listed below which require especially high reliability for the prevention of defects which might directly cause damage to the third party's life, body or property: Aerospace equipment (artificial satellite, rocket, etc.), Atomic energy-related equipment, Aviation equipment, Disaster prevention equipment, crime prevention equipment, Electric heating apparatus, burning equipment, Highly public information network equipment, data-processing equipment , Medical devices, Military equipment, Power generation control equipment, Safety equipment, Traffic signal equipment, Transportation equipment and
Undersea equipment, or for any other application or use in which the failure of YAGEO products could result in personal injury or death, or serious property damage. Particularly YAGEO Corporation and its affiliates do not recommend the use of commercial or automotive grade products for high reliability applications or manned space flight.
Information provided here is intended to indicate product specifications only. YAGEO reserves all the rights for revising this content without further notification, as long as products are unchanged. Any product change will be announced by PCN.
www.yageo.com