3R-6 YAGEO

Document overview

  • PDF pages: 7

Technical content

Page 1

PDF page 1 diagram
PDF page 1 diagram

Page 2

PDF page 2 diagram

Gas Discharge Tube (GDT) Data Sheet

Features

PDF page 2 diagram

■ Provide ultra-fast response to surge voltage from slow-rising surge of 100V/s to rapid-rising surge of 1KV/μs ■ Stable breakdown voltage

PDF page 2 diagram

■ High insulation resistance ■ Low capacitance (≤2pF) ■ High holdover voltage ■ Large absorbing transient current capability ■ Micro-Gap Design ■ Size: 6.0mm\*8.5mm ■ Storage and operating temperature: -40℃ ~ +85℃ ■ Meets MSL level 1, per J-STD-020 ■ Safety certification: UL

Applications

■ Repeaters, Modems ■ Telephone Interface, Line cards ■ Data communication equipment ■ Line test equipment

Part Number Code

PDF page 2 diagram
PDF page 2 diagram

/

Ordering Code Lead type Failsafe option Package
3RLXXXL-6/B 3RMXXXL-6/B Lead Box(Tray)
3RLXXXL-6-F/B 3RMXXXL-6-F/B Lead With failsafe mechanism Box(Tray)
3RLXXXM-6 3RMXXXM-6 SMD Tape & Reel

Page 3

PDF page 3 diagram

Marking

PDF page 3 diagram

Dimensions

L Type Symbol Dimension (mm)
Spec. Tolerance
D 6.0 +0.2, -0.5
T 8.5 ±0.5
T1 15.0 Max.
L 16.0 Max.
L-F Type S 3.8 ±0.3
d 0.8 ±0.1
R1 7.8 ±0.4
R2 6.3 ±0.3
M Type D 6.0 ±0.2
T 8.5 ±0.5
B 1.0 ±0.1
B1 1.5 ±0.2

Electrical Characteristics (3RL-6)

Part Number DC Spark-over Voltage Maximum Impulse Spark-over Voltage Nominal Impulse Discharge Current Alternating Discharge Current Impulse Life Minimum Insulation Resistance Maximum Capacitance Device Marking Code
100V/s 1000V/μs 8/20μs 10times 50Hz,1sec 10/1000μs 100A Test Voltage (GΩ) 1MHz
(V) (V) (KA) (A) (times) DC(V) (pF)
3RL075L-6 3 RL075M-6 75±20% 750 5.0 5.0 200 25 1.0 2.0 3RL075-6
3RL090L-6 3 RL090M-6 90±20% 750 5.0 5.0 200 50 1.0 2.0 3RL090-6
3RL150L-6 3 RL150M-6 150±20% 800 5.0 5.0 200 100 1.0 2.0 3RL150-6
3RL230L-6 3 RL230M-6 230±20% 800 5.0 5.0 200 100 1.0 2.0 3RL230-6
3RL250L-6 3 RL250M-6 250±20% 800 5.0 5.0 200 100 1.0 2.0 3RL250-6
3RL300L-6 3 RL300M-6 300±20% 900 5.0 5.0 200 100 1.0 2.0 3RL300-6
3RL350L-6 3 RL350M-6 350±20% 900 5.0 5.0 200 100 1.0 2.0 3RL350-6
3RL470L-6 3 RL470M-6 470±20% 950 5.0 5.0 200 250 1.0 2.0 3RL470-6
3RL600L-6 3 RL600M-6 600±20% 1300 5.0 5.0 200 250 1.0 2.0 3RL600-6

Page 4

PDF page 4 diagram

Electrical Characteristics (3RM-6)

Part Number DC Spark-over Voltage Maximum Impulse Spark-over Voltage Nominal Impulse Discharge Current Alternating Discharge Current Impulse Life Minimum Insulation Resistance Maximum Capacitance Device Marking Code
100V/s 1000V/μs 8/20μs 10times 50Hz,1sec 10/1000μs 100A Test Voltage (GΩ) 1MHz
(V) (V) (KA) (A) (times) DC(V) (pF)
3RM075L-6 3RM075M-6 75±20% 750 10 10 300 25 1.0 2.0 3RM075-6
3RM090L-6 3RM090M-6 90±20% 750 10 10 300 50 1.0 2.0 3RM090-6
3RM150L-6 3RM150M-6 150±20% 800 10 10 300 100 1.0 2.0 3RM150-6
3RM230L-6 3RM230M-6 230±20% 800 10 10 300 100 1.0 2.0 3RM230-6
3RM250L-6 3RM250M-6 250±20% 800 10 10 300 100 1.0 2.0 3RM250-6
3RM300L-6 3RM300M-6 300±20% 900 10 10 300 100 1.0 2.0 3RM300-6
3RM350L-6 3RM350M-6 350±20% 900 10 10 300 100 1.0 2.0 3RM350-6
3RM470L-6 3RM470M-6 470±20% 950 10 10 300 250 1.0 2.0 3RM470-6
3RM600L-6 3RM600M-6 600±20% 1300 10 10 300 250 1.0 2.0 3RM600-6

Electrical Ratings

Items Test Condition/Description Requirement
DC Spark-over Voltage The voltage is measured with voltage ramp dv/dt=100V/s. Test is between each side electrode and center electrode. To meet the specified value
Maximum Impulse Spark-over Voltage The maximum impulse spark-over voltage is measured with voltage ramp dv/dt=1000V/μs. Test is between each side electrode and center electrode.
Impulse Discharge Current Maximum surge current that can be applied through center electrode with 8/20μs waveform, for 10 times with 3min interval time, which will be equally divided between each side electrode to center electrode.
Alternating Discharge Current Rated RMS value of AC current at 50Hz, 1 sec. for 10 times with interval time 3 min. Test is between each side electrode and center electrode.
Insulation Resistance The resistance of gas tube shall be measured between each side electrodes and center electrode.
Capacitance The capacitance of gas tube shall be measured between each side electrodes and center electrode. Test frequency: 1MHz

Page 5

PDF page 5 diagram

Recommended Soldering Conditions

Wave Soldering

PDF page 5 diagram
PDF page 5 diagram
Item Conditions
Peak Temperature 265℃
Dipping Time 10 seconds
Soldering 1 time

Reflow Soldering

PDF page 5 diagram
PDF page 5 diagram
Profile Feature Pb-Free Assembly
Average ramp-up rate (T to T ) L P 3℃/second max.
Preheat -Temperature Min (T ) S min -Temperature Max (T ) S max -Time (min to max) (ts) 150℃ 200℃ 60-180 seconds
T to T S max L -Ramp-up Rate 3℃/second max.
Time maintained above: -Temperature (T ) L -Time (t ) L 217℃ 60-150 seconds
Peak Temperature (T ) P 260℃
Time within 5℃of actual Peak Temperature (t ) P 20-40 seconds
Ramp-down Rate 6℃/second max.
Time 25℃ to Peak Temperature 8 minutes max.

Page 6

PDF page 6 diagram

Packaging

Axial Packing (Box)

Skin packing Symbol Dimension (mm)
Spec. Tolerance
A 217.0 ±2.0
B 207.0 ±2.0
H 10.3 ±0.5
Quantity: 100pcs
Inner box A0 225.0 ±2.0
B0 210.0 ±2.0
H0 60.0 ±2.0
Quantity: 500pcs

SMD Packing (Tape & Reel)

Tape Symbol Dimension (mm)
Spec. Tolerance
W 16.00 ±0.20
P0 4.00 ±0.10
P1 16.00 ±0.10
P2 2.00 ±0.10
D0 1.55 ±0.05
E 1.75 ±0.10
F 7.50 ±0.10
A0 8.80 ±0.10
K0 6.20 ±0.10
B0 6.35 ±0.10
t0 0.50 ±0.05
Reel D 330.00 ±2.00
d 13.00 ±0.50
L 20.00 ±2.00
t 2.00 ±0.20
Quantity: 600pcs

Page 7

Product specification

Circuit Protection Components

LEGAL DISCLAIMER

YAGEO, its distributors and agents (collectively, “YAGEO”), hereby disclaims any and all liabilities for any errors, inaccuracies or incompleteness contained in any product related information, including but not limited to product specifications, datasheets, pictures and/or graphics. YAGEO may make changes, modifications and/or improvements to product related information at any time and without notice.

YAGEO makes no representation, warranty, and/or guarantee about the fitness of its products for any particular purpose or the continuing production of any of its products. To the maximum exten t permitted by law, YAGEO disclaims (i) any and all liability arising out of the application or use of any YAGEO product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for a particular purpose, non -infringement and merchantability.

YAGEO products are designed for general purpose applications under normal operation and usage conditions. Please contact YAGEO for the applications listed below which require especially high reliability for the prevention of defects which might directly cause damage to the third party's life, body or property: Aerospace equipment (artificial satellite, rocket, etc.), Atomic energy-related equipment, Aviation equipment, Disaster prevention equipment, crime prevention equipment, Electric heating apparatus, burning equipment, Highly public information network equipment, data-processing equipment , Medical devices, Military equipment, Power generation control equipment, Safety equipment, Traffic signal equipment, Transportation equipment and

Undersea equipment, or for any other application or use in which the failure of YAGEO products could result in personal injury or death, or serious property damage. Particularly YAGEO Corporation and its affiliates do not recommend the use of commercial or automotive grade products for high reliability applications or manned space flight.

Information provided here is intended to indicate product specifications only. YAGEO reserves all the rights for revising this content without further notification, as long as products are unchanged. Any product change will be announced by PCN.

www.yageo.com