CMXH-ST2-C5-7-DIOP FESTO
Document overview
- PDF pages: 2
Technical content
Page 1
Controller CMXH-ST2-C5-7-DIOP
Part number: 3605478

Data sheet
| Feature | Value |
| Type code | CMXH |
| Ambient temperature | 0 °C ... 50 °C |
| Type of mounting | On H-rail with accessories With screws in slots |
| Product weight | 700 g |
| CE marking (see declaration of conformity) | As per EU EMC directive as per EU machinery directive |
| Certification | RCM compliance mark |
| Degree of protection | IP20 |
| Storage temperature | -25 °C ... 75 °C |
| Note on materials | RoHS-compliant |
| Relative air humidity | 0 - 90 % Non-condensing |
| Fieldbus coupling | 1x CANopen slave |
| Electrical connection technology I/O | Socket, Sub-D, 15-pin |
| Number of digital logic inputs | 8 |
| Number of digital logic outputs 24 V DC | 5 |
| Information on digital logic inputs/outputs | Digital logic inputs/outputs are only available in I/O mode. |
| Bus connection | Plug 9-pin Sub-D |
| Controller operating mode | Direct operation Block selection |
| Process interfacing | For 31 blocks |
| Nominal voltage, logic supply DC | 24 V |
| Permissible range of logic voltage | ± 15 % |
| Nominal voltage, load supply DC | 48 V |
| Note on nominal operating voltage of DC load voltage supply | Alternatively, 24 V also possible. |
| Load supply permissible range | ± 10 % |
| Max. current consumption for logic supply without clamping brake | 0.2 A |
| Max. current consumption for logic supply with clamping brake and I/O | 0.9 A |
| Braking resistor | 15 Ohm |
| Note on braking resistor | Integrated braking resistor |
| Line filter | Integrated |
| Nominal current load supply | 10 A |
| Permissible load current | 12 A |
| Current rating per output | 100 mA |
2/10/21 - Subject to change - Festo AG & Co. KG
1/2
Page 2
| Feature | Value |
| Power failure buffering | 10 ms |
| Information on power failure buffering | The 10 ms value is not achieved when a brake is integrated. |
| Status indications | 7-segment display LED |
| Ethernet, number | 1 |
| Ethernet, supported protocols | TCP/IP, Modbus® TCP |
| Resistance to vibration | EN 60068-2-6 |
| Resistance to shock | EN 60068-2-27 |
| Protection class | III |
| Total number of axes | 2 |
| Activation methods | I/O standalone CAN bus TCP/IP |
| Communication profile | FHPP |
| Max. fieldbus transmission rate | 100 Mbit/s |
| Information on max. fieldbus transmission rate | 1 Mbit/s for CANopen |
| Supported kinematics systems | Planar surface gantry EXCM |
| Programming software | FCT (Festo Configuration Tool) |
| Dimensions W x L x H | 50 mm x 149 mm x 130 mm |
| Device-specific diagnostics | Diagnostic memory Short circuit in motor winding Undervoltage/overvoltage System and motor-oriented diagnostics |
| Configuration support | FCT (Festo Configuration Tool) |
| Parameterization | System parameter |
| Protocol | CANopen FHPP Modbus® TCP |
| Ethernet interface | RJ 45 (socket, 8-pin) |
| LED display (bus-specific) | Device: operating status Com: communication status |
| LED display (product-specific) | POWER: load voltage applied |
| Safety function | Safe torque off (STO) |
| Performance Level (PL) | Safe torque off (STO)/category 3, performance level e |
| Safety integrity level (SIL) | Safe torque off (STO)/SIL 3 |
| Certificate issuing authority | 01/205/5519.00/16 German Technical Control Board (TÜV) Rheinland |
| Proof test interval | 20 y |
| Diagnostic coverage | 90 % |
| SFF safe failure fraction | 99 % |
| Certified for safety functions to ISO 13849 (PL) | Product can be used in safety-related parts of control systems up to category 3, PL e |
| Certified for safety function to ISO 13849 and IEC 61508 (SIL) | Product can be used in safety-related parts of control systems up to SIL 3, high demand |
| Probability of Dangerous Failure per Hour (PFHd) | 2.0E-9 |
| MTTFd | STO/5700 years |
| Duration of use Tm | 20 y |
| Hardware fault tolerance | 1 |
| Characteristics of digital logic outputs | Not galvanically isolated |
2/10/21 - Subject to change - Festo AG & Co. KG
2/2