Technical content

Part number: 3472765 Data sheet Feature Value Dimensions W x L x H 50 mm x 107 mm x 55 mm Type code CPX Device-specific diagnostics Channel-oriented and module-oriented diagnostics Undervoltage/short circuit of modules Diagnostic memory CPU data 256 MB RAM

32 MB flash

800 MHz processor

Configuration support CODESYS V3 Parameterization CODESYS V3 Total number of axes 31 Additional functions Diagnostic functions SoftMotion functions for electric actuators Control elements DIL switch for CAN termination Rotary switch for RUN/Stop Programming, operating language DE, EN Programming, file handling support yes Processing time Approx. 200 µs/1 k instruction Intrinsic current consumption at nominal operating voltage Typ. 85 mA IP address setting DHCP Via CODESYS Via MMI Function blocks Read CPX module diagnostics CPX diagnostic status Copy CPX diagnostic trace and others Flag 28 kB remanent data CODESYS variable concept Nominal operating voltage DC load voltage Without pneumatics: 18 ... 30V 24 V With pneumatics type MPA: 18 ... 30 V Nominal operating voltage DC 24 V Power failure buffering 10 ms Programming software CODESYS provided by Festo 2/10/21 - Subject to change - Festo AG & Co. KG 1/2

Programming language as per IEC 61131-3 KOP AWL ST FUP AS Additionally CFC Program memory 16 MB user program Corrosion resistance class (CRC) 2 - Moderate corrosion stress Storage temperature -20 °C ... 70 °C Relative air humidity 95 % Non-condensing Degree of protection IP65 IP67 Ambient temperature -5 °C ... 50 °C Product weight 135 g Ethernet, number 1 Ethernet, data transmission speed 10/100 Mbit/s Ethernet, supported protocols TCP/IP , EasyIP , Modbus® TCP Ethernet, connector plug RJ45 Socket 8-pin Fieldbus interface, galvanic isolation yes Fieldbus interface, transmission rate 125, 250, 500, 800, 1000 kbit/s Adjustable via software Fieldbus interface, connection technology Plug Sub-D 9-pin Fieldbus interface, type CAN bus Protocol CODESYS level 2 EasyIP Modbus® TCP TCP/IP Control interface CAN bus Ethernet interface RJ 45 (socket, 8-pin) LED display (bus-specific) TP: link/traffic LED display (product-specific) ERR: PLC runtime error M: modify/forcing active PL: load supply PS: electronics supply, sensor supply RUN: PLC status SF: system fault STOP: PLC status Note on materials RoHS-compliant Housing material PA-reinforced PC 2/10/21 - Subject to change - Festo AG & Co. KG 2/2