MGA_V02 SCHURTER
Document overview
- Manufacturer or author: Provided By digicamel.com
- PDF pages: 4
Technical content
Fuses MGAhttps://www.schurter.com /PG01_2 Circuit Protection Solid State, Thin Film, SMD 1206, Super-Quick-Acting FF , 125 VAC, 125 VDC, 150 °C See below: Approvals and CompliancesUL 248-14 · 125 VAC · 125 VDC · Super-Quick-Acting FF
Description
- Max. ambient temperature 150 °C - Impermeable to potting compound used to achieve hermetic seal for use in intrinsically safe applications according to ATEx and IECEx re- quirements. Unique Selling Proposition - Hermetically sealed and robust construction - High breaking capacity up to 300 A - Smallest size
Applications
- Applications where high reliability and availability is needed - Medical Equipment - Offshore - Defense References Alternative: Space version Weblinks pdf data sheet, html datasheet, General Product Information, Distributor- Stock-Check, Detailed request for product Technical Data Rated Voltage 32 - 125 VAC, 125 VDC Rated current 0.2 - 5 A Breaking Capacity 50 A Characteristic Super-Quick-Acting FF Mounting PCB,SMT Admissible Ambient Air Temp. -55 °C to 150 °C Climatic Category 55/150/21 acc. to IEC 60068-1 Material: Housing Ceramics Material: Terminals Tin-Plated Nickel Unit Weight 0.03 g Storage Conditions 0 °C to 60 °C, max. 70% r.h. Product Marking none Soldering Methods Reflow, Wave Soldering Profile Solderability 245 °C / 3 sec acc. to IEC 60068-2-58, Test Td Resistance to Soldering Heat 260 +0/-5 °C / 30 sec acc. to IPC/JE- DEC J-STD-020D, Level 1 Moisture Sensitivity Level MSL 1, J-STD-020 Flammability min. UL 94V-1 (acc. to EIA/IS-722, Test 4.12) Moisture Resistance Test MIL-STD-202, Method 106 (50 cycles in a temp./mister chamber) Thermal Shock MIL-STD-202, Method 107D (200 air-to-air cycles from -55 to +125°C) Operational Life MIL-STD-202, Method 108 1000h @ 0.60 x In @ 70°C Load Humidity Test MIL-STD-202, Method 103 Resistance to Solvents MIL-STD-202, Method 215 Terminal Strength MIL-STD-202, Method 211A (Deflection of board 1 mm for 1 minute) Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agree- ments by SCHURTER. Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: MGA Approval Logo Certificates Certification Body Description UL Approvals UL UL File Number: E41599
FusesMGA https://www.schurter.com /PG01_2 Circuit Protection Product standards Product standards that are referenced Organization Design Standard Description Designed according to UL 248-14 Low voltage fuses - Part 14: Additional fuses Designed according to CSA22.2 No. 248.14 Low-Voltage Fuses - Part 14: Supplemental Fuses Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. UKCA declaration of conformity SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Dimension [mm] 3.2 mm 3.2 0.51 .55 1.55 Reflow soldering pads 1.5 1.1 Derating Curves 140 130 120 110 100 -60 -40 -20 0 20 40 60 80 100 120 140 160
Fuses MGAhttps://www.schurter.com /PG01_2 Circuit Protection Pre-Arcing Time Rated Current In 1.0 x In min. 2.5 x In max.
0.2 A - 5 A 4 h 5 s
Time-Current-CurvesTime in Seconds 0.001 0.01 0.1 100 1000 10000 100000 1 10 Multiple of Rated Current In All Variants Rated Cur- rent [A] Rated Vol- tage [VAC] Rated Vol- tage [VDC] Breaking Capacity Voltage Drop 1.0 In typ. [mV] Cold Resi- stance typ. [mΩ] Melting I²t 4.0 In typ. [A²s] Order Number 0.2 125 125 1) 258 1020 0.0008 l 3410.0021.01 █ 0.2 125 125 1) 258 1020 0.0008 l 3410.0021.02 0.2 125 125 1) 258 1020 0.0008 l 3410.0021.03 0.2 125 125 1) 258 1020 0.0008 l 3410.0021.04 0.25 125 125 1) 250 800 0.0009 l 3410.0022.01 0.25 125 125 1) 250 800 0.0009 l 3410.0022.02 █ 0.25 125 125 1) 250 800 0.0009 l 3410.0022.03 0.25 125 125 1) 250 800 0.0009 l 3410.0022.04 0.375 125 125 1) 165 361 0.0037 l 3410.0025.01 0.375 125 125 1) 165 361 0.0037 l 3410.0025.02 0.375 125 125 1) 165 361 0.0037 l 3410.0025.03 0.375 125 125 1) 165 361 0.0037 l 3410.0025.04 0.5 125 125 1) 150 247 0.0042 l 3410.0027.01 █ 0.5 125 125 1) 150 247 0.0042 l 3410.0027.02 0.5 125 125 1) 150 247 0.0042 l 3410.0027.03 0.5 125 125 1) 150 247 0.0042 l 3410.0027.04 0.75 125 125 1) 100 115 0.01 l 3410.0029.01 █ 0.75 125 125 1) 100 115 0.01 l 3410.0029.02 0.75 125 125 1) 100 115 0.01 l 3410.0029.03 0.75 125 125 1) 100 115 0.01 l 3410.0029.04 1 125 125 1) 124 98.7 0.035 l 3410.0031.01 █ 1 125 125 1) 124 98.7 0.035 l 3410.0031.02 1 125 125 1) 124 98.7 0.035 l 3410.0031.03
FusesMGA https://www.schurter.com /PG01_2 Circuit Protection Rated Cur- rent [A] Rated Vol- tage [VAC] Rated Vol- tage [VDC] Breaking Capacity Voltage Drop 1.0 In typ. [mV] Cold Resi- stance typ. [mΩ] Melting I²t 4.0 In typ. [A²s] Order Number 1 125 125 1) 124 98.7 0.035 l 3410.0031.04 1.5 125 125 1) 105 56 0.064 l 3410.0033.01 █ 1.5 125 125 1) 105 56 0.064 l 3410.0033.02 1.5 125 125 1) 105 56 0.064 l 3410.0033.03 1.5 125 125 1) 105 56 0.064 l 3410.0033.04 2 125 125 1) 98 39 0.089 l 3410.0035.01 2 125 125 1) 98 39 0.089 l 3410.0035.02 2 125 125 1) 98 39 0.089 l 3410.0035.03 2 125 125 1) 98 39 0.089 l 3410.0035.04 3 125 125 1) 88 24.1 0.18 l 3410.0037.01 █ 3 125 125 1) 88 24.1 0.18 l 3410.0037.02 3 125 125 1) 88 24.1 0.18 l 3410.0037.03 3 125 125 1) 88 24.1 0.18 l 3410.0037.04 4 63 125 2) 83.5 17 0.23 l 3410.0240.01 █ 4 63 125 2) 83.5 17 0.23 l 3410.0240.02 4 63 125 2) 83.5 17 0.23 l 3410.0240.03 4 63 125 2) 83.5 17 0.23 l 3410.0240.04 5 32 125 3) 90 13.5 0.45 l 3410.0141.01 █ 5 32 125 3) 90 13.5 0.45 l 3410.0141.02 5 32 125 3) 90 13.5 0.45 l 3410.0141.03 5 32 125 3) 90 13.5 0.45 l 3410.0141.04 █ Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER 1) 50 A @ 125 VAC / 300 A @ 125 VDC 2) 50 A @ 63 VAC / 50 A @ 125 VDC / 300 A @ 32 VDC 3) 50 A @ 32 VAC / 50 A @ 125 VDC / 300 A @ 32 VDC Packaging Unit acc. IEC 60286-3 Type 2a .xx = .01 100 pcs. in tape in ESD-plastic bag .xx = .02 750 pcs. in tape [W: 8mm and P1: 4mm] on reel [A: 18cm] .xx = .03 3000 pcs. in tape [W:8mm and P1: 4mm]on reel [A: 33cm] .xx = .04 10000 pcs. in tape [W: 8mm and P1: 4mm] on reel [A: 33cm] The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 04.01.2022