TOSHIBA Schottky Barrier Rectifier Stack Trench Schottky Barrier Type 30QWK2CZ47 Switching Type Power Supply Application Converter & Chopper Application
- Repetitive peak reverse voltage: V RRM = 120 V
- Peak Forward Voltage: VFM = 0.85 V (max)
- Average output recified current: IO = 30 A
- Low switching losses and output noise Absolute Maximum Ratings (Ta = 25°C) Characteristics Symbol Rating Unit Repetitive peak reverse voltage VRRM 120 V Average output recified current IO 30 A Peak one cycle surge forward current (non-repetitive, sine wave) IFSM 250 (50 Hz) A Junction temperature Tj −40~150 °C Storage temperature range Tstg −40~150 °C Screw Torque ⎯ 0.6 N ・m Note: Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the significant change in temperature, etc.) may cause this product to decrease in the reliability significantly even if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum ratings. Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook (“Handling Precautions”/Derating Concept and Methods) and individual reliability data (i.e. reliability test report and estimated failure rate, etc). Electrical Characteristics (Ta = 25°C) Characteristics Symbol Test Condition Min Typ. Max Unit Peak forward voltage VFM I FM = 15 A ⎯ ⎯ 0.85 V Repetitive peak reverse current IRRM V RRM = Rated (120 V) ⎯ ⎯ 50 μA Junction capacitance Cj V R = 10 V, f = 1.0 MHz ⎯ 227 ⎯ pF Thermal resistance Rth (j-c) Total DC, Junction to case ⎯ ⎯ 2.5 °C/W Note: V FM, IRRM, Cj: A value applied to one cell. Polarity Unit: mm JEDEC ― JEITA ― TOSHIBA 12-10C1A Weight: 2.0 g (typ.)
Abbreviation Code Part No. 30QWK2CZ 30QWK2CZ47 Handling Precaution Schottky barrier diodes have reverse current characteristics compared to other diodes. There is a possibility SBD may cause thermal runaway when it is used under high temperature or high voltage. Please take forward and reverse loss into consideration during design. The absolute maximum ratings denote the absolute maximu m ratings, which are rated values and must not be exceeded during operation, even for an instant. The following are the general derating methods that we recommend when you design a circuit with a device. VRRM: Use this rating with reference to the above. V RRM has a temperature coefficient of 0.1%/°C. Take this temperature coefficient into account designing a device at low temperature. IO: We recommend that the worst case current be no greater than 80% of the absolute maximum rating of IO and Tj be below 120°C. When using this device, take the margin into consideration by using an allowable Tamax-IO curve. IFSM: This rating specifies the non-repetitive peak curren t. This is only applied for an abnormal operation, which seldom occurs during the lifespan of the device. Tj: Derate this rating when using a device in order to ensure high reliability. We recommend that the device be used at a Tj of below 120°C. Please refer to the Rectifiers databook for further information. Lot No. A line indicates lead (Pb)-free package or lead (Pb)-free finish. 30QWK2CZ Characteristics indicator Part No. (or abbreviation code)
Transient thermal impedance rth (j-c) (°C/W) Surge forward current I FSM (A) Instantaneous forward voltage v F ( V ) iF – vF Instantaneous forward current i F (A) Average output rectified current I o (A) PF (AV) – Io Average forward power dissipation PF (AV) (W) Average output rectified current Io (A) Tc max – Io Average forward power dissipation Tc max (°C) Number of cycles Surge forward current (non-repetitive) Time t (s) rth (j-c) – t Reverse voltage V R (V) C j – VR (typical) Junction capacitance C j (pF) 160 180° 120° α = 30° 60° 90° 140 120 100 32 28 24 20 16 4 8 12 α 360° 0° Conduction angle α Rectangular waveform (one cell) 0.1 0.0 100 Tj = 150°C 25°C 75°C 100°C One cell 0 36 180° 120° α = 30° 60° 90° 4 8 12 16 20 24 28 32 α 360° 0° Conduction angle α Rectangular waveform (one cell) 320 1 100 Ta = 25°C Single phase full Sine wave f = 50 Hz One cell 280 240 200 160 120 10 3 5 30 50 1000 1 100 100 f = 1 MHz Ta = 25°C One cell 5 3 30 50 300 500 0.1 0.001 100 0.01 0.1 1 10 One cell 0.3 0.5
Junction temperature T j (°C) I R – Tj (typical) Reverse current I R ( m A ) Reverse voltage V R ( V ) P R (AV) – VR (typical) Average reverse power dissipation PR (AV) (W) 3.2 2.8 2.4 2.0 1.6 1.2 0.8 0.4 40 80 120 60 20 100 60° 120° 180° 240° 300° DC VR Conduction angle α Tj = 150°C Rectangular waveform 360°0° 0.001 100 0.01 20 40 60 80 100 120 160 0.1 140 100 VR = 10 V 120 Pulse measurement (one cell)
RESTRICTIONS ON PRODUCT USE 20070701-EN
- The information contained herein is subject to change without notice.
- TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity an d vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA produc ts, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIB A products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconduct or Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc.
- The TOSHIBA products listed in this document are in tended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.).These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfuncti on or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage incl ude atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, et c.. Unintended Usage of TOSHIBA products listed in his document shall be made at the customer’s own risk.
- The products described in this document shall not be used or embedded to any downstream products of which manufacture, use and/or sale are prohibited under any applicable laws and regulations.
- The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringement s of patents or other rights of the third parties which may result from its use. No license is granted by implic ation or otherwise under any patents or other rights of TOSHIBA or the third parties.
- Please contact your sales representative for product- by-product details in this document regarding RoHS compatibility. Please use these products in this document in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances. Toshiba assumes no liability for damage or losses occurring as a result of noncompliance with applicable laws and regulations.