Features
– Large capacity message filtering with 64 VLANs and 256 multicast groups provide increased network perfor- mance for expanding applications –- 1 0 60°C and -4075°C options, 5 or 8 ports and up to 2 multimode fiber ports allow selection of a cost-effective switch – 802.1x, radius authentication , user accounts and more provide flexible security options – Unique "cleanup" function hides unused configuration pages, reducing complexity, maintenance and startup times – Complete redundancy options, including the ability to mix RSTP and the new extended ring (three rings of up to 134 devices per ring), increases network uptime (<15 ms) for IT-compatible and control applications Make sure you always use the latest documentation. It can be downloaded from the product at www.phoenixcontact.net/catalog. This data sheet is valid for all products listed on the following page: 3037_en_B 2012-06-20
FL SWITCH 300... 3037_en_B PHOENIX CONTACT 2 Description Type Order No. Pcs. / Pkt. Managed Ethernet switch with four RJ45 ports at 10/100 Mbps, one SC for- mat fiber optic port and operating temperature of -40°C +75°C FL SWITCH 3004T-FX 2891033 1 Managed Ethernet switch with five RJ45 ports at 10/100 Mbps and operat- ing temperature of -10°C +60°C FL SWITCH 3005 2891030 1 Managed Ethernet switch with five RJ45 ports at 10/100 Mbps and operat- ing temperature of -40°C +75°C FL SWITCH 3005T 2891032 1 Managed Ethernet switch with eight RJ45 ports at 10/100 Mbps and oper- ating temperature of -10°C +60°C FL SWITCH 3008 2891031 1 Managed Ethernet switch with eight RJ45 ports at 10/100 Mbps and oper- ating temperature of -40°C +75°C FL SWITCH 3008T 2891035 1 Managed Ethernet switch with four RJ45 ports at 10/100 Mbps, one ST for- mat fiber optic port and operating temperature of -40°C +75°C FL SWITCH 3004T-FX ST 2891034 1 Managed Ethernet switch with six RJ45 ports at 10/100 Mbps, two SC for- mat fiber optic ports and an operating temperature of -40°C +75°C FL SWITCH 3006T-2FX 2891036 1 Managed Ethernet switch with six RJ45 ports at 10/100 Mbps, two ST for- mat fiber optic ports and an operating temperature of -40°C +75°C FL SWITCH 3006T-2FX ST 2891037 1 2O r d e r i n g d a t a Accessories Type Order No. Pcs. / Pkt. Lockable security element FL PATCH GUARD 2891424 20 Key for lockable security element FL PATCH GUARD KEY 2891521 1 Patch cable, CAT5, assembled, 0.3 m ( Cable/conductor ) FL CAT5 PATCH 0,3 2832250 10 Patch cable, CAT5, assembled, 0.5 m ( Cable/conductor ) FL CAT5 PATCH 0,5 2832263 10 Patch cable, CAT5, assembled, 1.0 m ( Cable/conductor ) FL CAT5 PATCH 1,0 2832276 10 Patch cable, CAT5, assembled, 2.0 m ( Cable/conductor ) FL CAT5 PATCH 2,0 2832289 10 Patch cable, CAT5, assembled, 3.0 m ( Cable/conductor ) FL CAT5 PATCH 3,0 2832292 10 Patch cable, CAT5, assembled, 5.0 m ( Cable/conductor ) FL CAT5 PATCH 5,0 2832580 10 Patch cable, CAT5, assembled, 7.5 m ( Cable/conductor ) FL CAT5 PATCH 7,5 2832616 10 Patch cable, CAT5, assembled, 10.0 m ( Cable/conductor ) FL CAT5 PATCH 10,0 2832629 10 Dimensions (in mm)
3 Technical data
54,4 125 146,4
FL SWITCH 300... 3037_en_B PHOENIX CONTACT 3 General data Width 54.4 mm Height 146.4 mm Depth 125 mm Mounting type NS 35 (IEC 60715) DIN rail Ambient temperature (storage/transport) -40°C ... 85°C Permissible humidity (operation) 5% ... 95% (no condensation) Permissible humidity (storage/transport) 5% ... 95% (no condensation) Air pressure (operation) 72 kPa ... 108 kPa (up to 3000 m above mean sea level) Air pressure (storage/transport) 66 kPa ... 108 kPa (up to 3500 m above mean sea level) Degree of protection IP20 Protection class III, VDE 0106, IEC 60536 Temperature range FL SWITCH 3004T-FX -40°C ... 75°C FL SWITCH 3005 -10°C ... 60°C FL SWITCH 3005T -40°C ... 75°C FL SWITCH 3008 -10°C ... 60°C FL SWITCH 3008T -40°C ... 75°C FL SWITCH 3004T-FX ST -40°C ... 75°C FL SWITCH 3006T-2FX -40°C ... 75°C FL SWITCH 3006T-2FX ST -40°C ... 75°C Weight FL SWITCH 3004T-FX 920 g FL SWITCH 3005 920 g FL SWITCH 3005T 920 g FL SWITCH 3008 940 g FL SWITCH 3008T 940 g FL SWITCH 3004T-FX ST 930 g FL SWITCH 3006T-2FX 960 g FL SWITCH 3006T-2FX ST 955 g Power Connection method Pluggable COMBICON screw connections, Conductor cross section [AWG] 24 ... 12 Supply voltage 24 V DC Supply voltage range 12 V DC ... 48 V DC Residual ripple 3.6 V PP (within the permitted voltage range)
FL SWITCH 300... 3037_en_B PHOENIX CONTACT 4 Current Current draw Inrush current FL SWITCH 3004T-FX 230 mA (24 V DC) 9.2 A (2 ms) FL SWITCH 3005 200 mA (24 V DC) 8.6 A (2 ms) FL SWITCH 3005T 200 mA (24 V DC) 8.6 A (2 ms) FL SWITCH 3008 210 mA (24 V DC) 8.6 A (2 ms) FL SWITCH 3008T 210 mA (24 V DC) 8.6 A (2 ms) FL SWITCH 3004T-FX ST 230 mA (24 V DC) 9.2 A (2 ms) FL SWITCH 3006T-2FX 330 mA (24 V DC) 8.2 A (2 ms) FL SWITCH 3006T-2FX ST 330 mA (24 V DC) 8.2 A (2 ms) Port configurations No. of RJ45 ports No. of fiber optic ports FL SWITCH 3004T-FX 4 1 ( SC ) FL SWITCH 3005 5 FL SWITCH 3005T 5 FL SWITCH 3008 8 FL SWITCH 3008T 8 FL SWITCH 3004T-FX ST 4 1 ( ST ) FL SWITCH 3006T-2FX 6 2 ( SC ) FL SWITCH 3006T-2FX ST 6 2 ( ST ) Ethernet (RJ45) Connection method RJ45 Transmission speed 10/100 MBit/s Transmission length 100 m Fiber optic interface Connection method SC Transmission speed 100 MBit/s (SC-D, full duplex) Wavelength 1300/1310 nm Transmission length 12.1 km (fiberglass with F-G 62.5/125 0.7 dB/km F1000) 3.3 km (fiberglass with F-G 62.5/125 2.6 dB/km F600) 7.1 km (fiberglass with F-G 50/125 0.7 dB/km F1200) 3.1 km (fiberglass with F-G 50/125 1.6 dB/km F800) Electrical isolation/isolation of the voltage areas Supply voltage/functional earth ground 500 V, 1 min Mechanical tests Shock test in acc. with IEC 60068-2-27 25g, 11 ms half-sine shock pulse Vibration resistance in acc. with IEC 60068-2-6 5g, 150 Hz, Criterion 3 Free fall in acc. with IEC 60068-2-32 1 m
FL SWITCH 300... 3037_en_B PHOENIX CONTACT 5
4 Managed switch functions
FL SWITCH 300 switches include context-sensitive help for hardware and firmware functions. Web viewing modes can be configured for different user types, such as maintenance, control engineers or network administrators, providing quick access to data. – Monitor mode provides one-click access to read-only di- agnostics – no logins and no searching for web pages – Administrative mode allows access to the complete range of switch functions and customizing of the user- mode web pages – User mode can be customized to include only those func- tions that are actually used, whether for start up or on-go- ing maintenance purposes. With one click, unwanted web pages are hidden from the user. Mix IT and high-performance redundancy The extended ring redundancy protocol allows network re- covery time in as little as 15 ms (18 ms between rings) and configurations up to 134 devices. Coupling of up to three rings of 134 switches each allows redundancy systems of over 300 switches. Coupling rings and ring ports may only be con- nected to other switches (no other devices allowed). Both ex- tended ring and IEEE redundancy may be operated simulta- neously in the switch. Complete IEEE STP/RSTP/MST options, with the additional option of extended ring redun- dancy, serves a broad range of IT compatability and industrial performance-based applications. Powerful network performance options The FL SWITCH 300 provides a complete range of mes- sage filtering and network performance-increasing functions. Performance may be scaled from basic to increasingly so- phisticated functions. Tailor security functions to your facility The FL SWITCH 300 provides a wide array of security func- tions that can be tailored to guard against unauthorized net- work access. Scaleable security measures can be used to protect against unauthorized access by people, devices or network communications. Telnet Yes SNMP V1, V2 Yes Serial interface Password protected for basic maintenance addressing and major function access Transfer of firmware and configuration files via TFTP Web view simplification Monitor, user and adminis- trative views. User mode is customizable by account type or individual. Network addressing BOOTP or DHCP IGMP snooping/query Yes; 256 multicast groups and GMRP support QoS: priority queus 4 QoS: ToS: COS diff serv Yes Link aggregation trunking Yes; up to four ports com- bined with LACP trunk con- trol Flow control User enable/disable by port Bandwidth rate control by message type by port Yes - percent bandwidth by message type to separate in- gress/egress transfer rates by port Time synchronization SNTP VLAN Static 16 port -based VLANs, 64 maximum; tagging-based VLAN supported with >4000 address range VLAN Dynamic (tagging based) GVRP Secure people access: Gen- eral Enable/disable Web inter- face and Telnet, 802.1x Ra- dius Authentication Secure people access: Man- age access to switch config- uration parameters User login accounts, custom- ization of read and read/write access, and control of func- tion access for each type of account or on an individual basis Secure device access MAC address filtering (up to 24) by port; enable/disable ports; and global MAC dis- card Secure network access SNMP V3 with encryption; enable/disable SNMP; https secure web access
FL SWITCH 300... 3037_en_B PHOENIX CONTACT 6
5 Structure
Figure 1 Structure (FL SWITCH 3006T-2FX shown)
1 Power supply/remote alarm connector
2 DB-9 serial port (RS-232)
3 Reset button
4 Power LEDs (US1/US2)
5 RJ45 ports
6 RJ45 port LEDs (LNK/ACT and 10/100 Mbps)
7 Fiber optic ports
8 Fiber optic port LEDs (LNK/ACT and 100 Mbps)
FL SWITCH 300... 3037_en_B 7PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany www.phoenixcontact.com
6 Installation
Position the device on the upper edge of the DIN rail and snap it into place with a downward motion. Removal Pull the release lever open using a screwdriver. Rotate the de- vice upward and remove from DIN rail. Power supply Figure 2 Redundant power supply connection Figure 3 Single power supply connection Snapping the switch onto a grounded rail connects it to the ground potential. In an environment particularly prone to EMI, noise immunity can be increased through the additional ground connections on the power connector. Alarm contacts FL SWITCH 300 switch provides contacts (R1 and R2) to provide an external alarm in the event of a failure. If either power supply fails (≤12 V) or a port fails (LNK), the internal dry contacts close. This device is designed for SELV and PELV operation according to IEC 61140/EN 61140. US1 GND US2 GND R1 R2 12345678 Individual ports that are monitored for alarm no- tification are configured using the software in- terface. Refer to the User Manual for details on configuration. US1 GND US2 GND R1 R2 12345678