Features
- Large collector current : IC=500mA
- Low collector saturation voltage enabling low-voltage operation
- Complementary pair with 2SA1979
Ordering Information
Type NO. Marking Package Code 2SC5342 C5342 TO-92 O u t l i n e D i m e n s i o n s u n i t : mm 4.4~4.6 4.4~4.6 0.38~0.42 1.27 Typ. 2.54 Typ. 1 2 3 3.35~3.55 2.15~2.35 1.96~2.16 1.1~1.3 0.38 14.0±0.40 SSeemmiiccoonndduuccttoorr PIN Connections 1. Emitter 2. Collector 3. Base
A b s o l u t e m a x i m u m r a t i n g s (Ta=25°C) Characteristic Symbol Ratings Unit Collector-Base voltage V CBO 40 V Collector-Emitter voltage V CEO 32 V Emitter-Base voltage V EBO 5 V Collector current I C 500 mA Collector dissipation P C 625 mW Junction temperature T j 150 °C Storage temperature T stg -55~150 °C E l e c t r i c a l C h a r a c t e r i s t i c s (Ta=25°C) Characteristic Symbol Test Condition Min. Typ. Max. Unit Collector-Base breakdown voltage BV CBO IC=100µA, IE=0 40 - - V Collector-Emitter breakdown voltage BV CEO I C=1mA, IB=0 32 - - V Emitter-Base breakdown voltage BV EBO IE=10µA, IC=0 5 - - V Collector cut-off current I CBO V CB=40V, IE=0 - - 0.1 µA Emitter cut-off current I EBO V EB=5V, IC=0 - - 0.1 µA DC current gain hFE * VCE=1V, IC=100mA 70 - 240 - Collector-Emitter saturation voltage V CE(sat) I C=100mA, IB=10mA - 0.25 V Transition frequency f T V CE=6V, IE=-20mA - 300 - MHz Collector output capacitance C ob V CB=6V, IE=0, f=1MHz - 7.0 - pF * : hFE Rank / O : 70~140, Y : 120~240
Electrical Characteristic Curves Fig. 4 V CE(SAT) - IC Fig. 3 I C - VCE Fig. 2 I C - VBE Fig. 1 Pc - Ta Fig. 5 h FE - IC
These AUK products are intended for usage in general electronic equipments(Office and communication equipment, measuring equipment, domestic electrification, etc.). Please make sure that you consult with us before you use these AUK products in equipm- ents which require high quality and/or reliabi lity, and in equipments which could have major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic signal, combustion central, all types of safety device, etc.). AUK cannot accept liability to any damage which may occur in case these AUK products were used in the mentioned equipments without prior consultation with AUK.