2R-4 YAGEO

Document overview

  • PDF pages: 7

Technical content

Page 1

PDF page 1 diagram
PDF page 1 diagram

Page 2

PDF page 2 diagram

Gas Discharge Tube (GDT) Data Sheet

Features

PDF page 2 diagram

■ Provide ultra-fast response to surge voltage from slow-rising surge of 100V/s to rapid-rising surge of 1KV/μs ■ Stable breakdown voltage ■ High insulation resistance ■ Low capacitance (≤1pF) ■ High holdover voltage ■ Large absorbing transient current capability ■ Micro-Gap Design ■ Size: 4.2mm\*4.0mm ■ Storage and operating temperature: -40℃ ~ +85℃ ■ Meets MSL level 1, per J-STD-020 ■ Safety certification: UL

Applications

■ Repeaters, Modems ■ Telephone Interface, Line cards ■ Data communication equipment ■ Line test equipment

Part Number Code

PDF page 2 diagram
PDF page 2 diagram

Marking

Page 3

PDF page 3 diagram

Dimensions

Size: 4.2x4.0mm series Symbol Dimension (mm)
Spec. Tolerance
D 4.2 ±0.3
T 4.0 ±0.3
B 0.4 ±0.2
d 3.9 ±0.2
Size: 4.0x5.6mm series Symbol Dimension (mm)
Spec. Tolerance
D 4.0 ±0.3
T 5.6 ±0.3
B 0.5 ±0.2

Electrical Characteristics

Part Number DC Spark-over Voltage 100V/s (V) Maximum Impulse Spark-over Voltage Nominal Impulse Discharge Current Alternating Discharge Current Impulse Life Minimum Insulation Resistance Maximum Capacitance Device Marking Code
1000V/μs 8/20μs 10times 50Hz,1sec 10/1000μs 100A Test Voltage (GΩ) 1MHz
(V) (KA) (A) (times) DC(V) (pF)
2RK075M-4 75±20% 800 3 3 300 25 1 1.0 075
2RK090M-4 90±20% 800 3 3 300 50 1 1.0 090
2RK145M-4 145±20% 800 3 3 300 100 1 1.0 145
2RK230M-4 230±20% 700 3 3 300 100 1 1.0 230
2RK250M-4 250±20% 700 3 3 300 100 1 1.0 250
2RK300M-4 300±20% 800 3 3 300 100 1 1.0 300
2RK350M-4 350±20% 850 3 3 300 100 1 1.0 350
2RK400M-4 400±20% 900 3 3 300 100 1 1.0 400
2RK470M-4 470±20% 1000 3 3 300 250 1 1.0 470
2RK600M-4 600±20% 1200 3 3 300 250 1 1.0 600
2RK800M-4 800±20% 1400 3 3 300 250 1 1.0 800
2RK1000M-4 1000±20% 1600 3 3 300 500 1 1.0 1000
2RK1200M-4 1200±20% 1900 3 3 300 500 1 1.0 1200

Note: Size 4.2x4.0mm series

Page 4

PDF page 4 diagram
Part Number DC Spark-over Voltage Maximum Impulse Spark-over Voltage Nominal Impulse Discharge Current Impulse Life Minimum Insulation Resistance Maximum Capacitance AC Withstanding Voltage Device Marking Code
100V/s 1000V/μs 8/20μs 10times 8/20μs 100A Test Voltage (GΩ) 1MHz
(V) (V) (KA) (times) DC(V) (pF)
2RK1400M-4 1400±20% 2800 3 300 500 1 1.0 - None
2RK1600M-4 1600±20% 3000 3 300 500 1 1.0 - None
2RK2000M-4 2000±20% 3800 3 300 1000 1 1.0 - None
2RK2500M-4 2500±20% 4200 3 300 1000 1 1.0 1250VAC, 3s None
2RK3000M-4 3000±20% 4500 3 300 1000 1 1.0 1500VAC, 3s None
2RK3600M-4 3600±20% 4800 3 300 1000 1 1.0 1850VAC, 3s None

Note: Size 4.0x5.6mm series

Electrical Ratings

Items Test Condition/Description Requirement
DC Spark-over Voltage The voltage is measured with voltage ramp dv/dt=100V/s. To meet the specified value
Maximum Impulse Spark-over Voltage The maximum impulse spark-over voltage is measured with voltage ramp dv/dt=1000V/μs.
Impulse Discharge Current Maximum 8/20μs surge current that can be applied between two electrodes, 5 positive and 5 negative surges, with 3 minutes interval time. Crest value 100 90 (%) Current 50 20µs 10 8µs 0 Time Impulse Width
Alternating Discharge Current Rated RMS value of AC current at 50Hz, 1 sec. for 10 times with interval time 3 min.
Insulation Resistance The resistance of gas tube shall be measured between two electrodes.
Capacitance The capacitance of gas tube shall be measured between two electrodes. Test frequency: 1MHz

Page 5

PDF page 5 diagram

Recommended Soldering Conditions

Reflow Soldering

Profile Feature Pb-Free Assembly
Average ramp-up rate (T to T ) L P 3℃/second max.
Preheat -Temperature Min (T ) S min -Temperature Max (T ) S max -Time (min to max) (ts) 150℃ 200℃ 60-180 seconds
T to T S max L -Ramp-up Rate 3℃/second max.
Time maintained above: -Temperature (T ) L -Time (t ) L 217℃ 60-150 seconds
Peak Temperature (T ) P 260℃
Time within 5℃ of actual Peak Temperature (t ) P 20-40 seconds
Ramp-down Rate 6℃/second max.
Time 25℃ to Peak Temperature 8 minutes max.

Packaging

Tape Symbol Dimension (mm)
Spec. Tolerance
W 16.00 ±0.20
P0 4.00 ±0.10
P1 12.00 ±0.20
P2 2.00 ±0.10
D0 1.55 ±0.05
E 1.75 ±0.10
F 7.50 ±0.10
A0 4.27 ±0.10
K0 5.20 ±0.10
B0 4.45 ±0.10
t 0.50 ±0.10

Page 6

PDF page 6 diagram
Reel D 330.00 ±2.00
d 13.00 ±0.50
L 20.00 ±2.00
t 2.00 ±0.20
Quantity: 900pcs

Note: Packaging for size 4.2x4.0mm series

Tape Symbol Dimension (mm)
Spec. Tolerance
W 16.00 ±0.20
P 8.00 ±0.20
P0 4.00 ±0.20
P1 2.00 ±0.20
D 1.50 ±0.10
E 1.75 ±0.10
F 7.50 ±0.10
A0 4.30 ±0.10
B0 5.80 ±0.10
K0 4.30 ±0.10
t 0.40 ±0.10
Reel D 330.00 ±2.00
d 13.00 ±0.50
L 20.00 ±2.00
t 2.00 ±0.20
Quantity: 1500pcs

Note: Packaging for size 4.0x5.6mm series

Page 7

Product specification

Circuit Protection Components

LEGAL DISCLAIMER

YAGEO, its distributors and agents (collectively, “YAGEO”), hereby disclaims any and all liabilities for any errors, inaccuracies or incompleteness contained in any product related information, including but not limited to product specifications, datasheets, pictures and/or graphics. YAGEO may make changes, modifications and/or improvements to product related information at any time and without notice.

YAGEO makes no representation, warranty, and/or guarantee about the fitness of its products for any particular purpose or the continuing production of any of its products. To the maximum exten t permitted by law, YAGEO disclaims (i) any and all liability arising out of the application or use of any YAGEO product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for a particular purpose, non -infringement and merchantability.

YAGEO products are designed for general purpose applications under normal operation and usage conditions. Please contact YAGEO for the applications listed below which require especially high reliability for the prevention of defects which might directly cause damage to the third party's life, body or property: Aerospace equipment (artificial satellite, rocket, etc.), Atomic energy-related equipment, Aviation equipment, Disaster prevention equipment, crime prevention equipment, Electric heating apparatus, burning equipment, Highly public information network equipment, data-processing equipment , Medical devices, Military equipment, Power generation control equipment, Safety equipment, Traffic signal equipment, Transportation equipment and

Undersea equipment, or for any other application or use in which the failure of YAGEO products could result in personal injury or death, or serious property damage. Particularly YAGEO Corporation and its affiliates do not recommend the use of commercial or automotive grade products for high reliability applications or manned space flight.

Information provided here is intended to indicate product specifications only. YAGEO reserves all the rights for revising this content without further notification, as long as products are unchanged. Any product change will be announced by PCN.