Technical content
Product: 29513 VFD 300% Gnd, 3C+IG #10 Str TC, XLPO Ins+PVC Gnd, OS+TC Brd, 1 Pr #16 Str TC XLPO IS, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable Product Description Belden 300% Ground Flexible VFD, 3 Conductor 10AWG (105x30) Tinned Copper, XLPO Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil®+Tinned Copper Braid(85%) Shield, 1 Pair 16AWG (26x30) Tinned Copper XLPO Beldfoil, Black PVC Outer Jacket, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable 1000V CSA AWM I/II A/B 600V CIC TC SUN RES DIR BUR Oil Resistant Technical Specifications Product Overview Suitable Applications: AC Motor drives, VFD, Variable Frequency drives Physical Characteristics (Overall) Conductor Element AWG Stranding Material No. of Conductors No. of Pairs XLPE 10 105x30 TC - Tinned Copper 3 Pair 16 26x30 TC - Tinned Copper 1 Ground Wire 10 105x30 TC - Tinned Copper 1 Conductor Count: 6 Insulation Material Nominal Wall Thickness XLPE - Cross Linked Polyethylene 0.046 in XLPE - Cross Linked Polyethylene 0.032 in PVC - Polyvinyl Chloride 0.046 in Color Chart Number Color
1 Black and White
2 Black #1
3 Black #2
4 Black #3
5 Green/Yellow
Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG Drainwire Construction n x D Tape Aluminum Foil-Polyester Tape Beldfoil® 100 % TC - Tinned Copper 18 19x30 Outer Shield Material Type Layer Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG Drainwire Construction n x D Tape 1 Aluminum/Polyester/Aluminum Duofoil® 100 % TC - Tinned Copper 10 105x30 mm Braid 2 TC - Tinned Copper 85 % Outer Jacket Material Material Nominal Diameter Nominal Wall Thickness Ripcord PVC - Polyvinyl Chloride 0.985 in 0.105 in Yes
Electrical Characteristics
Nominal Conductor DCR Nominal Inner Shield DCR
0.988 Ohm/1000ft
4 Ohm/1000ft 4.99 Ohm/1000ft Capacitance Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Shield 29 pF/ft 53 pF/ft 34 pF/ft Inductance Nominal Inductance 0.184 µH/ft Voltage UL Voltage Rating
1000 V RMS
600 V RMS (Type TC)
UL Temp Rating: 90°C Dry, 90°C Wet Operating Temp Range: -40°C To +90°C Mechanical Characteristics Max Recommended Pulling Tension: 718 lbs Min Bend Radius/Minor Axis: 9.9 in Standards NEC Articles: 336 - ER NEC/(UL) Specification: RHW-2, TC-ER CEC/C(UL) Specification: CIC, TC CSA AWM Specification: AWM I/II A/B PMSHA Specification: P-07-KA070003 Other Specification: 1000V UL Flexible Motor Supply Cable Applicable Environmental and Other Programs EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/96/EC (BFR): Yes EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU: Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes EU RoHS Compliance Date (yyyy-mm-dd): 2006-09-21 CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Suitability Suitability - Burial: Yes Suitability - Indoor: Yes Suitability - Outdoor: Yes Suitability - Sunlight Resistance: Yes Flammability, LS0H, Toxicity Testing UL Flammability: UL1685 UL Loading CSA Flammability: FT4 IEEE Flammability: 1202, 383
UL voltage rating: 1000 V RMS (Flexible Motor Supply Cable) Plenum/Non-Plenum Plenum (Y/N): No Part Number Variants Item # Color UPC Length Footnote 29513 010100 Black 612825137580 100 ft C 29513 0101000 Black 612825137597 1,000 ft C 29513 0103000 Black 612825137603 3,000 ft C Footnote: C - CRATE REEL PUT-UP. History Update and Revision: Revision Number: 0.312 Revision Date: 09-10-2019 © 2019 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.