2870 ETC2
Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 1
Technical content
For your nearest distributor, call 800-462-9832 or www.bkprecision.com 33 2870 2860A ■ Heavy Duty 1500 VDC rating ■ Ruggedized construction ■ Includes rubber boot ■ Withstands 5-foot drop ■ Extra large, high contrast LCD display ■ Gasket sealed against dirt and contaminants ■ Water resistant ■ High energy fused on all current ranges ■ Auto power off saves batteries ■ Built in probe holders ■ Non-slip grip ■ Extensive overload protection Model 2870 ■ 0.25% DCV accuracy ■ True RMS ■ Autoranging ■ Analog bargraph ■ 3 3/4 digit, 3200 count ■ Data hold, delay hold Model 2860A ■ 0.5% DCV accuracy ■ Manual ranging ■ 3 1/2 digit, 2000 count ■ Large 0.8" LCD display Five Year Warranty DC Volts Auto/Manual ranging Manual ranging Ranges 320mV , 3.2V , 32V , 320V , 1500V 200mV , 2V , 20V , 200V , 1500V Resolution 100µV , 1mV , 10mV , 100mV , 1V 100µV , 1mV , 10mV , 100mV , 1V Accuracy ±(0.25% rdg + 2 dgt) ±(0.5% rdg + 1 dgt) Overload protection 1500V peak 1500V peak Input Impedance 10M Ω 10MΩ AC Volts Auto/Manual ranging Manual ranging True RMS avg. responding, rms reading Ranges 3.2V , 32V , 320V , 750V 200mV , 2V , 20V , 200V , 1000V Resolution 1mV , 10mV , 100mV , 1V 100µV , 1mV , 10mV , 100mV , 1V Accuracy ±(1.3% rdg + 3 dgt) ±(1.25% rdg + 4 dgt) Frequency Response 40Hz - 1kHz 40Hz - 500Hz Overload Protection 1100V peak 1500V peak Input Impedance 10M Ω 10MΩ Current Auto/Manual ranging Manual ranging AC True RMS AC avg. responding, rms reading Ranges 320µA, 3.2mA, 32mA, 300mA, 20A* 200µA, 2mA, 20mA, 200mA, 20A* Resolution 0.1µA, 1µA, 10µA, 100µA, 10mA 0.1µA, 1µA, 10µA, 100µA, 10mA Accuracy (DC) ±(1.0% rdg + 2 dgt), ±(1.0% rdg + 1 dgt), ±(2.0% rdg + 3 dgt) for 20A ±(2.0% rdg + 3 dgt) for 20A Accuracy (AC) ±(2.5% rdg + 3 dgt) ±(1.5% rdg + 3 dgt), ±(2.5% rdg + 5dgt) for 20A ±(2.5% rdg + 4 dgt) for 20A Frequency Response 40Hz - 1kHz 40Hz-500Hz Overload Protection High energy 600V , 1A full for µA/mA, High energy 600V , 15A for 20A Resistance Auto/Manual ranging Manual ranging Ranges 320 Ω , 3.2kΩ , 32kΩ , 320kΩ , 200 Ω , 2kΩ , 20kΩ , 200kΩ , 3.2MΩ , 32MΩ 2MΩ , 20MΩ Resolution 0.1 Ω , 1Ω , 10Ω , 100Ω , 1kΩ , 10kΩ 0.1Ω , 1Ω , 10Ω , 100Ω , 1kΩ , 10kΩ Accuracy ±(0.5% rdg + 2 dgt) ±(0.75% rdg + 1 dgt) ±(2.0% rdg + 5 dgt) for 32MΩ ±(1.5% rdg + 5 dgt) for 20MΩ Overload Protection 600V peak 600V peak Diode Check T ested at 1.5mA, 3.3V max typical tested at 1mA 3.2V max typical Continuity Beeper sounds below 200 Ω approx. Beeper sounds below 100 Ω approx. Display 0.53" LCD, 3200 count with 0.8" LCD, 1999 count 65-segment analog bargraph Sampling rate 2/sec., 12/sec. for bargraph 2.5 /sec. Operating T emperature 32° to 122°F (0°C to 50°C), <80% RH Power Single 9V battery Battery life 200 hrs typ (alkaline) 250 hrs typ (alkaline) Auto power off Approx. 10 min. Approx. 30 min. Weight 18.3 oz. (519g) 12 oz. (353g) Specifications models 2870 2860A SUPPLIED: Battery, test leads, rubber holster, manual OPTIONAL: TL-1 Replacement T est Leads , TL-2A Deluxe T est Leads, TL-3 Accessory TIp Kit (for TL-2A), TL-130A General Purpose DMM Kit, PR-28A High Voltage Probe, CP-3 AC/DC Current Clamp Adapter Carrying Case (not included): LC-29B The “Survivor” name says it all! *10 A continuous, 20A for 30 seconds max. Accessories