X-2017, www.findernet.com K 1 or 2 Pole electromechanical step relay with electrically separate coil and contact circuits
- Choice of 6 switching sequences
- Screw terminal connections
- AC coil
- Panel mount
- Cadmium free contact material Screw terminal 26.01 26.02, 04, 06, 08 26.03
- Single phase switch 1 NO (SPST-NO)
- Double phase switch 2 NO (DPST-NO)
- 1 NO + 1 NC (SPST-NO + SPST-NC) For outline drawing see page 4 Contact specification Number of contacts 1 NO (SPST-NO) 2 NO (DPST-NO) 1NO+1NC (SPST-NO+SPST-NC) Rated current/Maximum peak current A 10/20 10/20 10/20 R ated voltage/ Maximum switching voltage V A C 250/400 250/400 250/400 Rated load AC1 V A 2500 2500 2500 Rated load AC15 (230 V AC) V A 500 500 500 Nominal lamp rating:
230 V incandescent/halogen W 800 800 800
tronic ballast W 400 400 400 fluorescent tubes with elec tromechanical ballast W 360 360 360 CFL W 200 200 200
230 V LED W 200 200 200
tronic ballast W 200 200 200 LV halogen or LED with elec tromechanical ballast W 400 400 400 Minimum switching load mW ( V/mA) 1000 (10/10) 1000 (10/10) 1000 (10/10) Standard contact material AgNi AgNi AgNi Coil specification Nominal voltage (UN) V AC (50 Hz) 12 - 24 - 48 - 110 - 230 12 - 24 - 48 - 110 - 230 12 - 24 - 48 - 110 - 230 V DC — — — Rated power AC/DC V DC — — — Technical data Mechanical life AC/DC c ycles 300 · 103 300 · 103 300 · 103 Minimum/Maximum impulse duration 0.1 s/1 h (according to EN 60669) 0.1 s/1 h (according to EN 60669) 0.1 s/1 h (according to EN 60669) Insulation between coil and contacts (1.2/50 µs) kV 4 4 4 A mbient temperature range P rotection category IP 20 IP 20 IP 20 Approvals (according to type) SERIES
26 SERIES
K
Ordering information
Example: 26 series screw terminal, panel mount relay, double phase switch 2 NO (DPST-NO) 10 A contacts, coil rated 12 V AC. Series Type 0 = Screw terminal No. of poles 1 = Single phase switch 1 NO (SPST-NO) 2 = Double phase switch 2 NO (DPST-NO) 3 = Double phase switch 1 NO + 1 NC (SPST-NO + SPST-NC) 4 = 4 sequences double phase switch 2 NO (DPST-NO) 6 = 3 sequences double phase switch 2 NO (DPST-NO) 8 = 4 sequences double phase switch 2 NO (DPST-NO) Coil voltage See coil specifications Coil version 8 = AC (50 Hz) Technical data Insulation Dielectric strength between supply and contacts V AC 3500 between open contacts V AC 2000 between adjacent contacts V AC 2000 Power lost to the environment with rated current and coil de-energised W 0.9 1.8 Screw torque Nm 0.8 0.8 Max. wire size solid cable stranded cable solid cable stranded cable AWG 1 x 12 / 2 x 14 1 x 14 / 2 x 14 1 x 12 / 2 x 14 1 x 14 / 2 x 14 Coil specifications AC version data Nominal voltage UN Coil code Operating range Resistance Consumption I at UN (50 Hz)Umin Umax R V V V Ω mA 12 8.012 9.6 13.2 17 370 24 8.024 19.2 26.4 70 180 48 8.048 38.4 52.8 290 90 110 8.110 88 121 1500 40 230 8.230 184 253 6250 20 Type Number of steps Sequence 1 2 3 4 26.01 2 26.02 2 26.03 2 26.04 4 26.06 3 26.08 4 X-2017, www.findernet.com
X-2017, www.findernet.com K Wiring diagrams N L Accessories for 12 and 24 V DC control applications Type: 026.9.012 Nominal voltage: 12 V DC Max temperature: +40 °C Operating range: (0.9…1.1)U N Type: 026.9.024 Nominal voltage: 24 V DC Max temperature: +40 °C Operating range: (0.9…1.1)U N Example of wiring for 24 V DC control application. Module for use with illuminated push buttons (230 V AC applications) Type 026.00 Sealed construction, 7.5 cm insulated flexible wire termination. Example of wiring diagram of type 026.00 This module is necessary when using between 1 and a maximum of 15 illuminated push buttons in the coil circuit (Each 1 mA max, 230 V AC). It must be connected in parallel to the coil of the relay (see diagram). SERIES
X-2017, www.findernet.com K Outline drawings 26.01 Screw terminal 26.03 Screw terminal 26.02 / 04 / 06 / 08 Screw terminal Please see general technical information4