2425510000 WEIDMULLER

Document overview

  • Manufacturer or author: Provided By digicamel.com
  • PDF pages: 5

Technical content

Creation date November 4, 2021 1:40:08 AM CET Catalogue status 22.10.2021 / We reserve the right to make technical changes. 1 ENERGY ANALYSER D550 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Increasingly non-linear loads and system components are entering production facilities. They influence the mains frequency, phase shift and the amplitudes of the phases. This has an influence on the quality of the electrical energy and therefore on system availability. Energy analysers, such as the Energy Analyser, measure all quality parameters of the electrical supply network: from the symmetry parameters through to the transients - and many more parameters besides. With the Energy Analyser you comprehensively test the quality of the electrical energy in your production facility and introduce optimisation steps to maximise the effectiveness and availability of your system. General ordering data Order No. 2425510000 Type ENERGY ANALYSER D550 GTIN (EAN) 4050118433487 Qty. 1 pc(s).

ENERGY ANALYSER D550 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Creation date November 4, 2021 1:40:08 AM CET Catalogue status 22.10.2021 / We reserve the right to make technical changes. 2 Dimensions and weights Depth 46 mm Depth (inches) 1.811 inch Height 90 mm Height (inches) 3.543 inch Width 107.5 mm Width (inches) 4.232 inch Net weight 350 g Temperatures Humidity at operating temperature 5…95 % RH Measuring current input Current-measuring channels 4 Distortion factor THD-I in % Yes Harmonics, per order / current 1.-40. Measuring accuracy for current 0.25 % Rated current 1 / 5 A Residual current measuring No Measuring voltage input Distortion factor THD-U in % Yes Four-wire system Yes Harmonics, per order / voltage 1.-40. Measurement range, voltage L-L, AC 480 V Measurement range, voltage L-N, AC 277 V Measuring accuracy for voltage 0.2 % Quadrants 4 Three-wire system Yes Communication Interface RS232: 9.6 – 115.2 kbps, RS485: 9.6 – 921.6 kbps, Ethernet, Web server/e- mail Protocol Modbus RTU, Modbus- Gateway, Modbus TCP/ IP, Modbus RTU over Ethernet, SNMP, BACnet (optional) Inputs/outputs Number of digital inputs 2 Number of digital outputs 2 Number of pulse outputs 2 Temperature input Yes Measurement data recording Memory; minimum and maximum values Yes Memory size 128 MB Number of memory values 5,000 k Update interval register 200 ms Min. memory recording interval 60 s Software ecoExplorer go® Integrated logic Yes

ENERGY ANALYSER D550 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Creation date November 4, 2021 1:40:08 AM CET Catalogue status 22.10.2021 / We reserve the right to make technical changes. 3 Technical data Input frequency < 20 Hz Rated current 1 / 5 A Standards DIN EN 61000-4-2, DIN EN 61000-4-3, DIN EN 61000-4-4, DIN EN 61000-4-5, DIN EN 61000-4-6, DIN EN 61000-4-8, DIN EN 61326-1, EN 61000-4-11, EN 55011, IEC 61010-1, IEC 61010-2-030 Measurement range, voltage L-N, AC 277 V Measurement range, voltage L-L, AC 480 V Surge voltage category 300 V CAT III Voltage supply 95 - 240 V AC, 135 - 340 V DC Three-wire system Yes Four-wire system Yes Quadrants 4 Sampling frequency 50/60 Hz 20 kHz Continuous measurements Yes Measurement result per second Effective value from the period (50/60 Hz) 10 / 12 Residual current measuring No Current-measuring channels 4 Measuring accuracy for voltage 0.2 % Measuring accuracy for current 0.25 % Measurement accuracy for active energy (kWh, …/5 A) Class 0.5S Operating-hours counter Yes Weekly time switch Yes Clock Yes Bimetal function Yes Peak load optimisation Yes Voltage quality measurement Harmonics, per order / voltage 1.-40. Harmonics, per order / current 1.-40. Distortion factor THD-U in % Yes Distortion factor THD-I in % Yes Unbalanced Yes Positive, negative and zero system Yes Brief interruptions Yes Sequence-of-events recorder function Yes Insulation coordination Surge voltage category 300 V CAT III Classifications ETIM 6.0 EC002301 ETIM 7.0 EC002301 ETIM 8.0 EC002301 ECLASS 9.0 27-14-23-30 ECLASS 9.1 27-21-03-01 ECLASS 10.0 27-14-23-30 ECLASS 11.0 27-14-23-30 Approvals Approvals ROHS Conform UL File Number Search E469563

ENERGY ANALYSER D550 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Creation date November 4, 2021 1:40:08 AM CET Catalogue status 22.10.2021 / We reserve the right to make technical changes. 4 Downloads Engineering Data STEP Software MODBUS Adressenliste Win64 - ecoExplorer go User Documentation Manual Energy Analyser D550 German/Englisch Quick Guide German/English Manual ECOEXPLORER GO English Catalogues Catalogues in PDF-format

ENERGY ANALYSER D550 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Drawings Creation date November 4, 2021 1:40:08 AM CET Catalogue status 22.10.2021 / We reserve the right to make technical changes. 5